• Title/Summary/Keyword: linear phase

Search Result 1,976, Processing Time 0.039 seconds

Splenic Irradiation in Chronic Myeologenous Leukemia (만성골수성백혈병 15예의 비장조사)

  • Oh Yoon Kyeong;Kwon Hyung Chul;Yoon Sei Chul;Bahk Yong Whee;Kim Choon Choo;Kim Dong Jip
    • Radiation Oncology Journal
    • /
    • v.3 no.2
    • /
    • pp.137-144
    • /
    • 1985
  • Radiation therapy was the treatment of choice for CML in the past, in the form of SI or radioactive phosphorus. Its use has been replaced to a large extent by various chemotherapeutic agents. Recently SI in CML has been used, both to relieve painful splenomegaly and to take advantage of an indirect effect of SI on unirradiated bone marrow. We have treated 15 CML cases who had a huge spleen during chemotherapy or even after chemotherapy by 6 MV linear accelerator during the past two years at the Division of Radiation Therapy, Kang Nam St. Mary's Hospital, Catholic College. Response to SI has been rated according to the scoring system of Roger W. Byhardt, et al. which evaluated the splenic and hematologic response as well as the response of disease-related systems. According to this scoring system, most patients demonstrated a significant relief of splenomegaly along with improvement of hemogram. And we observed the change of Karnofsky Performance Status after SI, and survival after a confirmative diagnosis and SI.

  • PDF

Photostimulated Luminescence and Photoluminescence of SrCl2:Eu2+ Phosphors (SrCl2:Eu2+ 형광체의 광발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.319-326
    • /
    • 2002
  • $SrCl_2:Eu^{2+}$ phosphors were prepared by the solid phase reaction method, and their photostimulated luminescence(PSL) and photoluminescence(PL) characteristics were investigated. The PSL and PL peak of the $SrCl_2:Eu^{2+}$ phosphors are due to the $5d{\rightarrow}4f$ transition of $Eu^{2+}$ ions in phosphors. The PSL and PL spectrum obtained by the 355nm excitation was observed in $380{\sim}440\;nm$ region with the peak at 407 nm. The dose response of the PSL phosphors were linear within $2.5\;mGy{\sim}200\;mGy$ of 100 kV X-ray. The fading of the phosphors at room temperature was approximately 60% after 20 min.

Development of Analytical Method for Colistin in Fish and Shrimp using Liquid Chromatography Mass Spectrometry (LC-MS/MS를 이용한 수산물 중 콜리스틴 분석법 개발)

  • Shin, Dasom;Kang, Hui-Seung;Lee, Soo-Bin;Cho, Yoon-Jae;Cheon, So-Young;Jeong, Jiyoon;Rhee, Gyu-Seek
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.5
    • /
    • pp.319-326
    • /
    • 2016
  • Colistin is a last resort antimicrobial agent against multi-drug resistant Gram-negative bacteria. This study was conducted to develop an analytical method to determine colistin in fish and shrimp. The analytes were confirmed and quantified via liquid chromatography-tandem mass spectrometry (LC-MS/MS) in the positive ion mode using multiple reaction monitoring (MRM). The sample was extracted with acidified 5% methanol (containing 0.5% formic acid). Then, solid phase extraction (SPE) was used for cleanup. Matrix-matched calibration curves were linear over the calibration ranges (0.05-1.2 mg/kg) for all the analytes into blank sample with $r^2$ > 0.99. All the values fulfilled the criteria requested by the Codex guidelines. Average recoveries ranged from 85.9% to 107.9%. The repeatability of measurements, expressed as the coefficient of variation (CV, %), was less than 15%. The limit of detection (LOD) was 0.02 mg/kg, and the limit of quantitation (LOQ) was 0.05 mg/kg. This improved method showed higher accuracy and acceptable sensitivity to meet the CAC guideline requirements and is applicable for the analysis of residual colistin (A+B) in fish and shrimp.

An analysis of the relationship between the Cold pattern and Anthropometry, Bio Impedance Analysis (BIA) and Quality of Life in Jeju Haenyeo (제주 해녀의 한증과 인체측량, 생체전기임피던스 지표 및 삶의 질과의 연관성 분석)

  • Lee, Eunyoung;Kim, Sujung;Lee, Siwoo;Cha, Seongwon;Lee, Youngseop;Mun, Sujeong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.20 no.3
    • /
    • pp.67-74
    • /
    • 2016
  • Objectives : The purpose of this study was to analyze the relationship between the Cold-pattern and the quantitative index through the results of an anthropometric method and Bio Impedance Analysis (BIA) of the Haenyeo living in Jeju island. Furthermore, we will examine the effect of Cold-pattern on the quality of life. Methods : BIA indices were acquired directly from Inbody770 and questionnaires were collected by Gallup Korea professional surveyor through face to face interviews. Binary regression analysis and linear regression analysis were used to examine the association between collected data. Results : Total of 175 of people were participated in this study. First, we examined the difference of the indicators in the Cold-pattern group and the non-Cold pattern group by the average comparison of the anthropometry and BIA indices. Most of the non-Cold pattern group showed high quality of life, BIA and anthropometry. In the relationship between Cold-pattern and anthropometry and BIA indices, BMI and PA indices were found to affect the Cold-pattern on a group basis. As the BMI increased by $1kg/m^2$, probability of not being non-Cold pattern was 1.13 times. and as the PA increased by $1^{\circ}$, probability of not being non-Cold pattern was 2.4 times. In the case of EQ5D value, the quality of life of ${\beta}$ was increased by 0.08 in non-Cold pattern (p <.05), EQ5D VAS of ${\beta}$ was also increased by 10.05 (p <.05). Conclusions : This study showed that BMI and PA could be used as a clinical index to evaluate the Cold-pattern as a clinical indicator, and there is a difference in quality of life according to Cold-pattern.

Transport behavior of a surfactant tracer(CPC) with Langmuir type adsorption isotherm on NAPL-water interface in a homogeneous porous medium (NAPL-물 계면에서 Langmuir형 흡착특성을 보이는 계면추적자(CPC)의 다공성 균질매질내 유동특성)

  • 김헌기;문희수;이상훈
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.3-13
    • /
    • 2001
  • It has been known that nonlinear characteristics of sorption affect the transport behavior of water soluble pollutants in soils. However detailed experimental studies have not been performed to verify the effect of non-linearity of adsorption isotherm on transport of chemicals in porous media. In this research, the distortion of breakthrough curves of a cationic surfactant (cetylpyridinium chloride, CPC) in a engineered stainless steel column packed with glass beads were investigated. Glass beads with about 110 $\mu\textrm{m}$diameter coated with a thin n-decane film were used as the media providing the sorption surface for CPC. The CPC adsorption isotherm on the surface of n-decane from aqueous solution was a typical Langmuir type. The breakthrough curve of CPC using step Input showed a late breakthrough on the front side and early breakthrough on the back side accordance to the shape of the isotherm. The retardation factor of CPC was found to be a strong function of the input concentration, which also a manifestation of the non-linearity of the isotherm. The retardation factors for the CPC with step input agreed with those of pulse input that the maximum concentrations are controlled to be the same as the step input concentrations. This results support the validity of the unproven field practices of using hydrogeotracers with non-linear adsorption isotherms to determine the hydrogeological parameters, e.g., NAPL saturation, air-water or NAPL-water interfacial areas.

  • PDF

Structural Properties of MO-SiO$_2$(M=Zn, Sn, In, Ag, Ni) by Sol-Gel Method (졸겔법으로 제조된 MO-$SiO_2$(M=Zn,Sn,In,Ag,Ni)의 구조특성)

  • Sin, Yong-Uk;Kim, Sang-U
    • Korean Journal of Materials Research
    • /
    • v.11 no.7
    • /
    • pp.603-608
    • /
    • 2001
  • $MO-SiO_2$ (M = Zn, Sn, In, Ag, Ni) binary silica gels were synthesized by sol-gel method and their structural change with the kind of metal ions was characterized by XRD, FT- IR and $^{29}$Si-NMR. Although X-ray analysis showed partial recrystallization of $AgNO_3$ in $Ag-SiO_2$gel, crystalline phase formed by the bonding between metal ion and the silica matrix didn't appear in all $MO-SiO_2$ gels. The FT-IR analysis showed that Zn, Sn and in partially formed Si-O-M bonding in silica matrix and made an shift of absorption peak to by Si-O-Si symmetrical vibration. In addition, $^{29}Si-NMR$ studies showed that Zn, Sn and In didn't affect sol-gel process of silica and were linked with non-bridging oxygen of the linear silica structure, which formed imperfect network because of low temperature sol-gel process. Ag and Ni make a role of catalysis on sol-gel process, resulting in densifying the silica network structure.

  • PDF

Generation of Korean Ionospheric Total Electron Content Map Considering Differential Code Bias (Differential Code Bias를 고려한 한반도 전리층 총전자수 지도 생성)

  • Lee, Chang-Moon;Kim, Ji-Hye;Park, Kwan-Dong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.293-301
    • /
    • 2011
  • The ionospheric delay is the largest error source in GPS positioning after the SA effect has been turned off in May, 2000. In this study, we used 44 permanent GPS stations being operated by National Geographic Information Institute (NGII) to estimate Total Electron Content (TEC) based on pseudorange measurements phase-leveled by a linear combination with carrier phases. The Differential Code Bias (DCB) of GPS satellites and receivers was estimated and applied for an accurate estimation of the TEC. To validate our estimates of DCB, changes of TEC values after DCB application were investigated. As a result, the RMS error went down by about an order of magnitude; from 35~45 to 3~4 TECU. After the DCB correction, ionospheric TEC maps were produced at a spatial resolution of $1^{\circ}{\times}1^{\circ}$. To analyze the effect of the number of sites used for map generation on the accuracy of TEC values, we tried 10, 20, 30, and 44 stations and the RMS error was computed with the Global Ionosphere Map as the truth. While the RMS error was 5.3 TECU when 10 sites are used, the error reduced to 3.9 TECU for the case of 44 stations.

Rapid and Simple Method for the Determination of Pregabalin in Human Plasma using Liquid Chromatography-tandem Mass Spectrometry (LC-MS/MS): Application to a Bioequivalence Study of Daewoong Pregabalin Capsule To Lyrica® Capsule (Pregabalin 150 mg)

  • Jang, Ki-Ho;Seo, Ji-Hyung;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.4
    • /
    • pp.255-262
    • /
    • 2011
  • Method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed and validated for the determination of pregabalin in plasma samples. Acquisition was performed by monitoring the transitions: m/z 160.1${\rightarrow}$142.2 for pregabalin and m/z 423.2${\rightarrow}$207.1 for losartan (as an internal standard). After cold acetonitrileinduced protein precipitation of the plasma samples, separation was performed with C18 column by isocratic mobile phase consisted of 10 mM ammonium acetate and acetonitrile (15:85, v/v). Results were linear over the concentration ranged from 0.1 to $10{\mu}g$/mL and the correlation coefficients (r) were $\geq0.99$. Intra- and inter-day precisions were $\leq6.02$ and $\leq11.04%$, respectively, and intra- and inter-day accuracies were 96.60-101.09 and 98.10-102.60%, respectively. This validated method was successfully applied to a bioequivalence study of two formulations of pregabalin, Daewoong pregabalin capsule (Daewoong Pharm. Co., Ltd.) and Lyrica$^{(R)}$ capsule (Pfizer Korea Ltd.) in twenty eight healthy Korean volunteers. The subjects received a single oral dose of each formulation (150 mg as pregabalin) in a randomized $2{\times}2$ crossover study and plasma samples were obtained from each subject at predetermined time intervals. Then, the pharmacokinetic parameters ($AUC_{0-t}$, $C_{max}$ and $T_{max}$) were calculated and statistically analyzed to assess the differences between two formulations. The 90% confidence intervals for the log-transformed data were acceptable range of log 0.8-log 1.25 (e.g., log 1.0048-log 1.0692 for AUC0-t, log 0.9142-log 1.0421 for $C_{max}$). Thus, $AUC_{0-t}$ and $C_{max}$ met the criteria of the Korea Food and Drug Administration (KFDA) for bioequivalence test indicating that Daewoong pregabalin capsule was bioequivalent to Lyrica$^{(R)}$ capsule.

Evaluation of Antioxidant Activity of Sugar Alcohols Using TOSC (Total Oxy-radical Scavenging Capacity) Assay (TOSC 법을 이용한 당알코올의 항산화 활성 평가)

  • Kang, Keon-Wook;Kwak, Sang-Hoon;Yun, Sei-Young;Kim, Sang-Kyum
    • Toxicological Research
    • /
    • v.23 no.2
    • /
    • pp.143-150
    • /
    • 2007
  • Although animal and epidemiological studies have suggested oxidative stress as an etiological factor in pathogenesis including cancer, inflammation, sepsis, fibrosis, cardiovascularlneurodegenerative diseases and aging-related disorders, conflicting results have been obtained in clinical trial with antioxidants. The reason for this discrepancy remains unknown but may be due, in part, to the lack of a validated assay system for evaluating antioxidant capacity. The antioxidant activity of a series of sugar alcohols against peroxyl radicals, hydroxyl radicals and peroxynitrites was determined by the total oxy-radical scavenging capacity (TOSC) assay and cell-based assay using H4IIE cells. Specific TOSC values calculated from the slope of the linear regression for erythritol, xylitol, sorbitol or mannitol against peroxyl radicals was $2.1{\pm}0.2,\;3.7{\pm}0.3,\;9.1{\pm}0.3$ or $8.7{\pm}1.1$ TOSC/mM, respectively. Specific TOSC values for erythritol, xylitol, sorbitol or mannitol against peroxynitrite was $1.9{\pm}0.3,\;3.9{\pm}0.4,\;7.8{\pm}0.7$ or $7.7{\pm}0.5$ TOSC/mM, respectively. These results suggest that oxy-radical scavenging capacity is dependent on the number of aliphatic hydroxyl group in sugar alcohols of monosaccharide. Tert-butylhydroperoxide (t-BHP)-induced cell toxicity determined by MTT assay was marginally attenuated by 10 mM erythritol, but completely inhibited by 10 mM xylitol, 2 mM sorbitol or 0.75 mM maltitol, a disaccharide alcohol. Oxidative stress markers, such as glutathione (GSH) and malondial-dehyde (MDA) levels, were measured in t-BHP-treated cells using HPLC equipped with a fluorescence detector and a reverse phase column. Erythritol did not change the levels of GSH and MDA in H411E cells treated with t-BHP. The t-BHP-induced changes in cellular GSH and MDA levels were ameliorated by 10 mM xylitol and completely blocked by 10 mM sorbitol and maltitol. These results indicate that sugar alcohols protect cells against oxidative stress via scavenging oxy-radical and suggest that TOSC assay in conjunction with cell-based assay is a valid method for evaluating antioxidant capacity of natural and synthetic chemicals.

Bioequivalence Study of Toriem® Tablet to Motilium-M® Tablet (Domperidone Maleate 12.72 mg) Evaluated by Liquid Chromatography/Tandem Mass Spectrometry

  • Ryu, Ju-Hee;Choi, Sang-Jun;Lee, Myung-Jae;Lee, Jin-Sung;Kang, Jong-Min;Tak, Sung-Kwon;Seo, Ji-Hyung;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • The aim of the present study was to evaluate the bioequivalence of two domperidone maleate tablets, Motilium-$M^{(R)}$ Tablet (Janssen Korea Ltd., reference product) and $Toriem^{(R)}$ Tablet (Daewon Pharm. Co., Ltd., test product). Domperidone was extracted by liquid-liquid extraction using tert-butyl methyl ether and separated in less than 3 min on $C_{18}$ reverse-phase column using an isocratic elution. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z $426.1{\rightarrow}119.1$ and the m/z $837.4{\rightarrow}158.2$ transitions for domperidone and the internal standard (roxithromycin), respectively. Calibration curves, from $0.05{\sim}50$ ng/mL of domperidone, showed correlation coefficients (r) higher than 0.9941. Intra day and inter day precision (C.V. %) for quality control were ranged from 10.04 to 16.09% and from 10.87 to 18.69%, respectively. The lower limit of quantification (LLOQ) of domperidone was 0.05 ng/mL. The method described is precise and sensitive and has been successfully applied to the study of bioequivalence of domperidone in 24 healthy Korean volunteers. Twenty-four healthy male Korean volunteers received a single dose of each medicine ($2{\times}12.72\;mg$ domperidone maleate) in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of domperidone were monitored for over a period of 24 hr after the administration. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were within acceptable range of log 0.8 to log 1.25 (e.g., $log\;0.92{\sim}log\;1.05$ for $AUC_{0-t}$, $log\;0.81{\sim}log\;1.05$ for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that $Toriem^{(R)}$ tablet is bioequivalent to Motilium-$M^{(R)}$ tablet.