• Title/Summary/Keyword: linear measurement

Search Result 2,021, Processing Time 0.033 seconds

STANDARDS FOR KOREAN ADULT FACIAL RELATIONSHIPS BY VARIOUS ROENTGENO - CEPHALOMETRIC ANALYSIS (두부(頭部)X선(線) 규격(規格) 측모사진계측(側貌寫眞計測)에 의한 한국인(韓國人) 성년남녀(成年男女)의 표준치(標準値)에 관(關)한 연구(硏究))

  • Lee, Chong Taik
    • The korean journal of orthodontics
    • /
    • v.18 no.2
    • /
    • pp.459-474
    • /
    • 1988
  • A study was made of a method of rational assessment on the roentgeno-cephalogram in orthodontic practice. Fifty eight measurements were analyzed on the roentgeno-cephalograms of 50 male and 50 female Korean adults with the acceptable profile and the normal occlusion. The means and standard deviations of measurements were studied in male and female groups by various analytic methods, and the sex difference was examined statistically. The obtained data were compared with those of the Japanese and American standards by useing a Japanese adults standard polygon chart reported by lizuka and Ishikawa. Amongs of 58 measurements, 14 have been selected as statistically significant and clinically useful, and used to make a Korean adult standard polygon chart. The results obtained were as follows: 1. Standards for cphalometric analysis in Korean adults were obtained, and the polygon chart and cephalometric profilogram were also made by using the standards in order to apply to a clinical diagnosis. 2. The sex difference was recognized in linear measurements, but not in angular measurments. 3. In comparison with the American standards from Downs and Graber, the Korean showed significant differences in angle of convexity, mandibular plane angle, Y-axis angle, interincisal angle and lower incisor to mandibular plane angle. Thus, the Korean showed a more retruded chin position, convex facial type, than white people. 4. In comparison with the Japanese standards from Iizuka and Ishikawa, the Korean showed a significant similarity with the Japanese, especially in females. 5. Upper incisor to Huxely line angle, established as a new measurement, proved to be paralell to X-Y axis angle.

  • PDF

Evaluation of Ovary Dose for woman of Childbearing age Woman with Breast cancer in tomotherapy (가임기 여성의 유방암 토모치료 시 난소선량 평가비교)

  • Lee, Soo Hyeung;Park, Soo Yeun;Choi, Ji Min;Park, Ju Young;Kim, Jong Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.337-343
    • /
    • 2014
  • Purpose : The aim of this study is to evaluate unwanted scattered dose to ovary by scattering and leakage generated from treatment fields of Tomotherapy for childbearing woman with breast cancer. Materials and Methods : The radiation treatments plans for left breast cancer were established using Tomotherapy planning system (Tomotherapy, Inc, USA). They were generated by using helical and direct Tomotherapy methods for comparison. The CT images for the planning were scanned with 2.5 mm slice thickness using anthropomorphic phantom (Alderson-Rando phantom, The Phantom Laboratory, USA). The measurement points for the ovary dose were determined at the points laterally 30 cm apart from mid-point of treatment field of the pelvis. The measurements were repeated five times and averaged using glass dosimeters (1.5 mm diameter and 12 mm of length) equipped with low-energy correction filter. The measures dose values were also converted to Organ Equivalent Dose (OED) by the linear exponential dose-response model. Results : Scattered doses of ovary which were measured based on two methods of Tomo helical and Tomo direct showed average of $64.94{\pm}0.84mGy$ and $37.64{\pm}1.20mGy$ in left ovary part and average of $64.38{\pm}1.85mGy$ and $32.96{\pm}1.11mGy$ in right ovary part. This showed when executing Tomotherapy, measured scattered dose of Tomo Helical method which has relatively greater monitor units (MUs) and longer irradiation time are approximately 1.8 times higher than Tomo direct method. Conclusion : Scattered dose of left and right ovary of childbearing women is lower than ICRP recommended does which is not seriously worried level against the infertility and secondary cancer occurrence. However, as breast cancer occurrence ages become younger in the future and radiation therapy using high-precision image guidance equipment like Tomotherapy is developed, clinical follow-up studies about the ovary dose of childbearing women patients would be more required.

L-band SAR-derived Sea Surface Wind Retrieval off the East Coast of Korea and Error Characteristics (L밴드 인공위성 SAR를 이용한 동해 연안 해상풍 산출 및 오차 특성)

  • Kim, Tae-Sung;Park, Kyung-Ae;Choi, Won-Moon;Hong, Sungwook;Choi, Byoung-Cheol;Shin, Inchul;Kim, Kyung-Ryul
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.5
    • /
    • pp.477-487
    • /
    • 2012
  • Sea surface winds in the sea off the east coast of Korea were derived from L-band ALOS (Advanced Land Observing Satellite) PALSAR (Phased Array type L-band Synthetic Aperture Radar) data and their characteristics of errors were analyzed. We could retrieve high-resolution wind vectors off the east coast of Korea including the coastal region, which has been substantially unavailable from satellite scatterometers. Retrieved SAR-wind speeds showed a good agreement with in-situ buoy measurement by showing relatively small an root-mean-square (RMS) error of 0.67 m/s. Comparisons of the wind vectors from SAR and scatterometer presented RMS errors of 2.16 m/s and $19.24^{\circ}$, 3.62 m/s and $28.02^{\circ}$ for L-band GMF (Geophysical Model Function) algorithm 2009 and 2007, respectively, which tended to be somewhat higher than the expected limit of satellite scatterometer winds errors. L-band SAR-derived wind field exhibited the characteristic dependence on wind direction and incidence angle. The previous version (L-band GMF 2007) revealed large errors at small incidence angles of less than $21^{\circ}$. By contrast, the L-band GMF 2009, which improved the effect of incidence angle on the model function by considering a quadratic function instead of a linear relationship, greatly enhanced the quality of wind speed from 6.80 m/s to 1.14 m/s at small incident angles. This study addressed that the causes of wind retrieval errors should be intensively studied for diverse applications of L-band SAR-derived winds, especially in terms of the effects of wind direction and incidence angle, and other potential error sources.

The Optimal Condition of Performing MTT Assay for the Determination of Radiation Sensitivity (방사선 감수성 측정법으로서 MTT 법 시행 시의 최적 조건에 대한 연구)

  • Hong, Se-Mie;Kim, Il-Han
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.163-170
    • /
    • 2001
  • Purpose : The measurement of radiation survival using a clonogenic assay, the established standard, can be difficult and time consuming. In this study, We have used the MTT assay, based on the reduction of a tetrazolium salt to a purple formazan precipitate by living cells, as a substitution for clonogenic assay and have examined the optimal condition for performing this assay in determination of radiation sensitivity. Materials and Methods : Four human cancer cell lines - PCI-1, SNU-1066, NCI-H630 and RKO cells have been used. For each cell line, a clonogenic assay and a MTT assay using Premix WST-1 solution, which is one of the tetrazolium salts and does not require washing or solubilization of the precipitate were carried out after irradiation of 0, 2, 4, 6, 8, 10 Gy. For clonogenic assay, cells in $25\;cm^2$ flasks were irradiated after overnight incubation and the resultant colonies containing more than 50 cells were scored after culturing the cells for $10\~14$ days. For MTT assay, the relationship between absorbance and cell number, optimal seeding cell number, and optimal timing of assay was determined. Then, MTT assay was performed when the irradiated cells had regained exponential growth or when the non-irradiated cells had undergone four or more doubling times. Results : There was minimal variation in the values gained from these two methods with the standard deviation generally less than $5\%$, and there were no statistically significant differences between two methods according to t-test in low radiation dose (below 6 Gy). The regression analyses showed high linear correlation with the $R^2$ value of $0.975\~0.992$ between data from the two different methods. The optimal cell numbers for MTT assay were found to be dependent on plating efficiency of used cell line. Less than 300 cells/well were appropriate for cells with high plating efficiency (more than $30\%$). For cells with low plating efficiency (less than $30\%$), 500 cells/well or more were appropriate for assay. The optimal time for MTT assay was after 6 doubling times for the results compatible with those of clonogenic assay, at least after 4 doubling times was required for valid results. In consideration of practical limits of assay (12 days, in this study) cells with doubling time more than 3 days were inappropriate for application. Conclusion : In conclusion, it is found that MTT assay can successfully replace clonogenic assay of tested cancer cell lines after irradiation only if MTT assay was undertaken with optimal assay conditions that included plating efficiency of each cell line and doubling time at least.

  • PDF

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

Basic Study on the Development of Analytical Instrument for Liquid Pig Manure Component Using Near Infra-Red Spectroscopy (근적외선 분광법을 이용한 돈분뇨 액비 성분분석기 개발을 위한 기초 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, C.H.;Jeong, K.H.;Kim, J.H.;Song, J.I.;Yoo, Y.H.;Chung, M.S.;Yang, C.B.
    • Journal of Animal Environmental Science
    • /
    • v.13 no.2
    • /
    • pp.113-120
    • /
    • 2007
  • This study was conducted to measure Nitrogen(N), Phosphate($P_2O_5$), Potassium ($K_2O$), Organic matter(OM) and Moisture content of liquid pig manure by Near Infrared Spectroscopy(NIRS) and to develop an alternative and analytical instrument which are used for measurement of N, $P_2O_5$, $K_2O$, OM, and Moisture contents for liquid pig manure. The liquid pig manure sample's transmittance spectra were measured with a NIRS in the wavelength range of 400 to 2,500 nm. Multiple linear regression and partial least square regression were used for calibrations. The correlation coefficient(RSQ) and standard error of calibration(SEC) obtained for nitrogen were 0.9190 and 2.1649, respectively. The RSQ for phosphate, potassium, organic matter and moisture contents were 0.9749, 0.5046, 0.9883 and 0.9777, and the SEC were 0.5019, 1.9252, 0.1180 and 0.0789, respectively. These results are indications of the rapid determination of components of liquid pig manure through the NIR analysis. The simple analytical instrument for liquid pig manure consisted of a tungsten halogen lamp for light source, a sample holder, a quartz cell, a SM 301 spectrometer for spectrum analyzer, a power supply, an electronics, a computer and a software. Results showed that the simple analytical instrument that was developed can approximately predict the phosphate, organic matter and moisture content of the liquid pig manure when compared to the analysis taken by NIRS. The low predictability value of potassium however, needs further investigation. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing liquid pig manure.

  • PDF

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.

The Effect of Aquaplast on Surface Dose of Photon Beam (Aquaplast가 광자선의 표면선량에 미치는 영향)

  • Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.95-100
    • /
    • 1995
  • Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy Materials and Methods: To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in $25{\times}25{\times}3cm^3$ acrylic phantom and set on $25{\times}25{\times}5cm^3$ polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 100cm SSD for $5{\times}5cm^2$, $10{\times}10cm^2$ and $15{\times}15cm^2$ field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types of Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and Khan to correct overresponse of the Markus chamber. Results : The surface doses for open fields of $5{\times}5cm^2$, $10{\times}10cm^2$, and $15{\times}15cm^2$ were $79\%$, $13.6\%$, and $18.7\%$, respectively. The original Aquaplast increased the surface doses upto $38.4\%$, $43.6\%$, and $47.4\%$, respectively. For transformed Aquaplast, they were $31.2\%$, $36.1\%$, and $40.5\%$, respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by $0.2\%$, $1.7\%$, $3.0\%$ without Aquaplast, $0.2\%$, $1.9\%$, $3.7\%$ with transformed Aquaplast, respectively. Conclusion: The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax, however, were not affected by Aquaplast. In conclusion, although the use of Aquaplast in practice may cause some increase of skin and buildup region dose, reductioin of skin-sparing effect will not be so significant clinically.

  • PDF

GROWTH AND DEVELOPMENT OF ARCH FORM (치열궁의 성장 변화)

  • Sohn, Byung-Wha;Baik, Hyoung-seon
    • The korean journal of orthodontics
    • /
    • v.28 no.1 s.66
    • /
    • pp.17-27
    • /
    • 1998
  • Study on growth change of dental arch is considered to both an important data in orthodontic diagonsis and treatment planning as well as analysis of treatment results , also, arch form is important in anthropology and dentistry, even more so in prosthodontics and orthodontics. In the field of orthodontics, studies on the functional aspect of upper and lower teeth and maintenance of stability of dentition and occlusion were carried out from the early days. Some of the early studies include explanation of growth change in dental arch from measuring directly fom human stroll, and afterwards, cephalometrics x-rays were introduced; accordingly, studies using cephalometric measurement and linear measurements of study models were often performed. By this method, arch width, arch depth and perimeters were measured, and growth change or dental arch was studied. The subject ror this study were sn children(boys and girls or ages from 3 yens to 12 years from Kang-won district and Seoul, who has no history of orthodontic treatment and who show healthy status and normal growth and development. Cephalometric x-ray, panoramic x-ray, and study model were taken for each subject consecutively for 2 years, and the subjects are still followed up. 400 pairs of study models from the past two years were used in this study; mesio-distal diameater of each tooth, intercanine width, intermolar width, canine depth, molar depth and arch perimeters were measured. Afterwards, mean value and each standard deviation of each age group and each gender were obtained, and representation graph were drawn. The following conclusion were obtained. 1. Intercanine width showed gradual increase until the age of 10-years and after that, showed no increase. 2. Intermolar width in upper arch showed gradual increase : intermolar width in lower arch showed no significant chang, and after the age of 9-years, showed increase. 3. Cainine arch depth showed relatively rapid increase after the age of 6-years, and this pattern was more obvious in lower arch. 4. Molar arch depth increased gradually in both archs and it decrease after the age of 10-years : this phenomenon was more prominent in the lower arch. 5. Arch perimeter showed gradual inerease and convert to plateau at the age of 10-years, after that, it decreased. this pattern was more prominent in lower arch.

  • PDF

STABILITY OF OBWEGESER II METHOD IN MANDIBULAR PROGNATHIC OR ANTERIOR OPEN BITE PATIENTS (하악전돌증 및 개교합 환자에 있어 Obwegeser Ⅱ method의 안정성)

  • Jung, Chang-Wook;Nam, Jeong-Hun;Lee, Sang-Han;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.1
    • /
    • pp.25-33
    • /
    • 2004
  • The purpose of this study was to evaluate the postoperative stability of the severe open bite or mandibular prognathic patients after mandibular set back surgery by Obwegeser II method. There were 19 patients who had been undergone Obwegeser II method. The horizontal and vertical position of the cephalometric points were measured preoperation and immediate postoperation, postoperative 1 month, postoperative 6 months ; were analyzed by linear measurement to evaluate changes in skeletal landmark and the relapse was compared between open bite group and prognathism group. By the operation, horizontal change of B was $6.84{\pm}4.35mm$ and vertical change of B was $6.28{\pm}3.25mm$ in open bite group and horizontal change of B was $14.20{\pm}4.81mm$ and vertical change of B was $1.99{\pm}2.66mm$ in prognathism group, horizontal change of Pog was $3.82{\pm}5.71mm$ and vertical change of Pog was $5.38{\pm}2.11mm$ in open bite group and horizontal change of Pog was $13.24{\pm}5.99mm$ and vertical change of Pog was $1.91{\pm}0.94mm$ in prognathism group. Between immediate postoperation and postoperative 1 month, all skeletal landmarks change was no statistical difference (p>0.05) and there were no statistical difference between open bite group and prognathism group except x-Me landmark (p>0.05). Between postoperative 1 month and 6 months, horizontal change of B was $0.12{\pm}1.35mm$ and vertical change of B was $1.47{\pm}1.48mm$ in open bite group and horizontal change of B was $1.43{\pm}1.35mm$ and vertical change of B was $0.82{\pm}1.99mm$ in prognathism group, horizontal change of Pog was $0.13{\pm}1.40mm$ and vertical change of Pog was $0.88{\pm}1.71mm$ in open bite group and horizontal change of Pog was $1.08{\pm}1.74mm$ and vertical change of Pog was $0.47{\pm}1.57mm$ in prognathism group (p>0.05) and there were no statistical difference between open bite group and prognathism group (p>0.05). Between immediate postoperation and postoperative 6months, horizontal change of B was $0.24{\pm}1.17mm$ and vertical change of B was $1.87{\pm}1.63mm$ in open bite group and horizontal change of B was $1.54{\pm}1.55mm$ and vertical change of B was $1.04{\pm}1.96mm$ in prognathism group, horizontal change of Pog was $0.91{\pm}1.46mm$ and vertical change of Pog was $1.18{\pm}2.05mm$ in open bite group and horizontal change of Pog was $0.96{\pm}1.62mm$ and vertical change of Pog was $1.23{\pm}2.35mm$ in prognathism group (p>0.05) and there were statistical difference between open bite group and prognathism group in x-B, x-Pog, x-Gn, x-Me (p<0.05). Obwegeser II method is considered as one of the best operation when surgical correction of severe open bite or severe mandibular prognathism is needed.