• 제목/요약/키워드: linear induction motor

검색결과 341건 처리시간 0.027초

영상분 3고조파 전압을 이용한 속도센서없는 유도전동기 벡터제어 시스템의 파라미터 변동 보상 (A Compensation Method of Parameter Variations for the Speed-Sensorless Vector Control System of Induction Motors using Zero Sequence Third Harmonic Voltages)

  • 최정수;김진수;김영석
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권2호
    • /
    • pp.75-82
    • /
    • 1999
  • A compensation method of the motor parameters using zero sequence third harmonic voltage is presented for the speed sensorless vector control of the induction motor considering saturation of the flux. Generally, the air-gap flux of the saturated induction motor contains the space harmonic components rotating with the synchronous frequency of the motor. Because the EMF of the saturated induction motor contains the zero sequence harmonic voltages at the neutral point of the motor, those harmonic voltages can be used as a saturation index. In this work, the rotor flux observer is firstly designed for the speed sensorless vector control of induction motor. And a novel measurement method of the space harmonic voltage and a compensation method of th LPF(Low Pass Filter) are proposed. For compensating the non-linear variations of the magnetizing inductance depending on the saturation level of the motor, the dominant third harmonic voltage of the motor is used as a saturation function of the air-gap flux. And the variation of the stator resistance owing to the motor temperature can also be measured with the phase angle between the impressed voltage vector and the zero sequence voltage. The validity of the proposed parameter compensation scheme in the speed sensorless vector control using rotor flux observer is verified by the result of the simulations and the experiments.

  • PDF

A new flux observer based vector control in induction motors

  • Tsuji, Mineo;Li, Hanqiang;Izumi, Katsuhiro;Kobuchi, Taiki;Yamada, Eiji
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1994년도 Proceedings of the Korea Automatic Control Conference, 9th (KACC) ; Taejeon, Korea; 17-20 Oct. 1994
    • /
    • pp.708-713
    • /
    • 1994
  • A new flux observer based vector control system of an induction motor is constructed by using an observer in which the commanded stator currents are used to estimate the rotor flux. In this system, the flux observer is formulated by using a model of induction motor in a stationary coordinate system. By considering an observer of induction motor in a fixed co-ordinate system located on its secondary flux, a slip frequency controlled type of vector control system is also proposed. From these control schemes, the relation between the conventional slip frequency controlled type system and the observer based one is clarified. The steady-state error of the developed torque which is caused by the parameter change of induction motor is analyzed and discussed for the selection of observer gains. The poles of the observer error dynamics and those of the observer based vector control system are calculated analytically by neglecting the machine parameter change. In order to analyze the robust stability, a linear model of the observer based vector control system is proposed taking into account the machine parameter change. By using this model, the trajectories of the poles and zeros of the torque transfer function are computed and discussed. To test validity of the theoretical analysis, experiments are conducted by using a digital signal processor (TMS320C30) and a current controlled voltage source PWM inverter.

  • PDF

경전철용 LIM 설계 및 해석 연구 (A Study of Design and Analysis of LIM for Light rail vehicle)

  • 최병원;허익구;이인우;박창순;권태근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1414-1416
    • /
    • 2000
  • In the future light rail vehicle is more attractive than subway, because of construction time and cost. For light rail vehicle are two types of traction motors. one is traditional rotating type and the other is linear motor. Linear motor is not better in consideration of efficiency and power factor than rotating type. But the motor needs no translation equipment for linear motion and with them can be constructed low floor vehicle. In this paper will be designed a linear induction motor with consideration of operational condition and analysed operating characteristics using FEM program and equivalent circuit.

  • PDF

비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads)

  • 김종겸;박영진;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

반송용 편측식 선형유도전동기의 센서리스 속도제어 (Sensorless Speed Control of the Conveyance SLIM)

  • 신동률;김영빈;노인배;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.1971-1973
    • /
    • 1997
  • Space Vector control of linear induction motor without speed sensor is one of the most up-to-date researching subjects to the engineers in the fields of power electronics and control theory. A conveyance SLIM (Single-sided Linear Induction Motor) has required a stable speed and a soft start/stop when the goods convey. So, the close loop control method to use a speed sensor have been adopted and as the speed sensor, a linear encorder has been used. But when the speed sensor used, the application boundary is limited and the confidence of system is diminished because it is sensitive to external environment variations and its cost is very expensive. So, to solve these problems, this paper deals with speed control of the conveyance SLIM using space vector without speed sensorless.

  • PDF

DTC를 이용한 농형 선형유도전동기의 위치 제어 (Position Control of Linear Induction Motor with Cage-type Secondary Using Direct Thrust Control)

  • 김경민;박승찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.9-11
    • /
    • 2004
  • This paper presents a position control system for a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC). The position controller, that combines the merits of integral-proportional(IP) speed control, is designed for the LIM. The actual position of the LIM is defected by the linear scale the resolution of 100. Thrust correction coefficient due to the end effect of the LIM is utilized in estimating actual thrust. As a result, responses of the position, speed, thrust, and flux are shown.

  • PDF

자기부상열차 가속 순간 부상공극 변화 (Air Gap Change of a Maglev Vehicle at the Moment a Linear Induction Motor Runs)

  • 신현재;한형석;김동성;김봉섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1218-1223
    • /
    • 2009
  • LIM(Linear induction motor)s are the main type of motors used for urban Maglev vehicles because they are less expensive to operate at a lower speed than linear synchronous motors. An LIM generates an attraction force while running, which perturbs the air gap of the electromagnet. This undesirable air gap variation could result in the mechanical contact of an electromagnet with the reaction plate. For this reason, the magnitude of the air gap variation must be limited within a certain range. The air gap changes when running the 1/2 vehicle under development for testing are analyzed through a test on the test track at KIMM. The results from this study could be used to minimize the air gap variations due to attraction force from LIM.

  • PDF

공극 공차가 선형유도전동기에 미치는 영향 (Influence of the airgap tolerance on performance of a Linear Induction Motor)

  • 이형우;이성구;박찬배;권삼영;이병송;이주;박현준
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1468-1472
    • /
    • 2009
  • This paper presents the influence of the airgap tolerance on performance of a linear induction motor. Construction tolerance of the plate affects directly to the cost and performance of the Linear metro. LIM has around 10[mm] large airgap with many restrictions such as construction tolerance, thermal expansion and bend of the reaction plate, abrasion of the wheel, and so on. In order to have steady performance, the airgap should be uniform. But it is impossible to maintain the secondary reaction plate be flat along with the long track. Therefore the influence of the flatness on performance of a LIM should be investigated.

  • PDF

직접 추력 제어에 의한 농형 선형 유도 전동기의 속도 제어 (Speed Control of Linear Induction Motor with Cage-type Secondary Using Direct Thrust Control)

  • 김경민;박승찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.920-922
    • /
    • 2004
  • This paper presents a speed control system for a linear induction motor(LIM) with cage-type secondary using direct thrust control(DTC). The actual speed of the LIM is detected by the linear scale with the resolution of $100{\mu}m$. Thrust correction coefficient due to the end effect of the LIM is utilized in estimating actual thrust. As a result, responses of the thrust, current, speed, and flux are shown.

  • PDF

3상 4선식에서 비선형 부하의 운전시 유도전동기의 특성 해석 (Characteristics Analysis of Induction Motor by Operation of Non- linear Loads under the 3-phase 4-wire grid system)

  • 김종겸;박영진;이은웅
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.43-48
    • /
    • 2006
  • This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system. Under the combination operation of single & three phase load, voltage unbalance will be generated and current unbalance will be more severe by the dropped voltage quality. All power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. Moors may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration.

  • PDF