• 제목/요약/키워드: linear generator

검색결과 412건 처리시간 0.025초

3상 집중권 권선을 갖는 코어리스/코어드 타입 리니어 발전기의 공간고조파 해석법을 이용한 전기자 반작용 자계특성 해석 (Comparison and Analysis of Armature Reaction Magnetic Field of Linear Generator with Coreless/Cored Type Three Phases Concentrated Winding by using Space Harmonic Analytical Method)

  • 서성원;구민모;강한빛;최장영
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.64-71
    • /
    • 2015
  • This paper deals with analysis of armature reaction magnetic field of linear generator with three phases coreless/cored type concentrated winding. On the basis of a magnetic vector potential and Maxwell's equations, governing equations to predict armature reaction field are derived, and current density modeling is also performed analytically by using the Fourier series expansion. The analytical method used in this paper is confirmed by comparing with finite element analysis results.

부이 내장형 선형발전기 및 그 응용 연구 (Study on Electrical Linear Generator Containing Heaving Buoy and Its Applications)

  • 차경호;김정택
    • 신재생에너지
    • /
    • 제9권4호
    • /
    • pp.25-31
    • /
    • 2013
  • This paper describes an electrical linear generator (IntELG) based on permanent magnets, containing heaving buoy, and its applications for the floating wave energy converters riding in parallel waves. The permanent magnets are integrated with the heaving buoy as a component and the integrated component is configured within the cylindrical IntELG to be filled with fluid. Thus, the IntELG can effectively be applied for the power-take-off of the floating wave energy converter riding in parallel waves. Typical applications are exampled with the Pelamis and Anaconda and they are investigated for the diversely redundant power source of nuclear power plant and the cooperation with submerged tunnel(s).

해석적 방법을 이용한 양측식 선형 영구자석 발전기의 특성해석 (Characteristic Analysis of Double sided Permanent Magnet Linear Generator by using Analytical Method)

  • 강한빛;최장영;김경환;홍기용
    • 전기학회논문지
    • /
    • 제63권5호
    • /
    • pp.652-659
    • /
    • 2014
  • This paper deals with characteristic analysis of double sided permanent magnet linear generator using analytical method. We derived magnetic field solutions produced by permanent magnet and armature reaction based on the 2D polar coordinate and magnetic vector potential. based on the derived magnetic field solutions, Induced voltage is obtained when arbitrary sinusoidal input condition. In addition, electrical parameters such as back-EMF constant, resistance, and inductance are obtained. Finally, generating performance characteristic at the rated load and various load is examined by using equivalent circuit.

Behaviour Analysis of Self Excited Induction Generator Feeding Linear and No Linear Loads

  • Moulahoum, Samir;Kabache, Nadir
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1371-1379
    • /
    • 2013
  • Application of induction machines in wind turbine driven generators is a good alternative due to their good characteristics such as efficiency, reliability and low cost. Nevertheless, when isolated operation is required, the application of external capacitive bank, connected to the stator windings, to provide self-excitation results in a rather complex analysis. This paper presents an analysis of self-excited induction generator connected to a load either directly or by an intermediate of a power converter. At first a dynamic model of the induction generator accounting for magnetic saturation is developed. Then a number of balanced and unbalanced capacitors, passive and active loads are verified. Experimental results obtained from laboratory tests are compared to those simulated; the two are shown to be in good agreement.

Stochastic precipitation modeling based on Korean historical data

  • Kim, Yongku;Kim, Hyeonjeong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제23권6호
    • /
    • pp.1309-1317
    • /
    • 2012
  • Stochastic weather generators are commonly used to simulate time series of daily weather, especially precipitation amount. Recently, a generalized linear model (GLM) has been proposed as a convenient approach to fitting these weather generators. In this paper, a stochastic weather generator is considered to model the time series of daily precipitation at Seoul in South Korea. As a covariate, global temperature is introduced to relate long-term temporal scale predictor to short-term temporal predictands. One of the limitations of stochastic weather generators is a marked tendency to underestimate the observed interannual variance of monthly, seasonal, or annual total precipitation. To reduce this phenomenon, we incorporate time series of seasonal total precipitation in the GLM weather generator as covariates. It is veri ed that the addition of these covariates does not distort the performance of the weather generator in other respects.

Controller Design for Static Reactive Power Generator in Transmission System

  • Han, B.M.;Soh, Y.C.;Kim, H.W.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.398-403
    • /
    • 1998
  • This paper describes a controller design for the stator reactive power generator in the transmission system. The controller of static reactive power generator was designed using a mathematical model and non-linear state feedback. The performance of controller was verified using computer simulation with EMTP code and experimental work with scaled-model. The dynamic interaction with a simple power system was also analyzed using both the simulation model and hardware scaled-model. Both simulation and experimental results prove that the controller using PI block and non-linear state feedback offers better performance than the controller using PI block only.

  • PDF

민감도를 이용하여 풍력단지가 연계된 송전계통의 최적혼잡처리 (Optimal Congestion Management Based on Sensitivity in Power System with Wind Farms)

  • 최수현;김규호
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.1965-1970
    • /
    • 2016
  • This paper studies generator rescheduling technique for congestion management in power system with wind farms. The proposed technique is formulated to minimize the rescheduling cost of conventional and wind generators to alleviate congestion subject to operational line overloading. The generator rescheduling method has been used with incorporation of wind farms in the power system. The locations of wind farms are selected based upon power transfer distribution factor (PTDF). Because all generators in the system do not need to participate in congestion management, the rescheduling has been done by generator selection based on the proposed generator sensitivity factor (GSF). The selected generators have been rescheduled using linear programming(LP) optimization techniques to alleviate transmission congestion. The effectiveness of the proposed methodology has been analyzed on IEEE 14-bus systems.

Performance Improvement of the Linear BLDC Generator in a NASA Deep Space Explorer

  • Lee, Hyung-Woo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.108-113
    • /
    • 2004
  • This paper presents methods to improve performance of the power supply system in a NASA deep space explorer. In the Stirling engine driven reciprocating Brushless DC (BLDC) generator, the accurate position information of the prime mover is important to diagnose the performance of the engine and prevent distortion of the output power. Since sensors to detect the position are fragile and unreliable, and conventional sensorless techniques have drawbacks in the low speed region, a novel sensorless position detection technique for the prime mover has been proposed and verified. Another major issue of the generator for the spacecraft is power density maximization. The mass of the power system is important to the mass of the satellite. Therefore, the components of the spacecraft should be lightweight. Conventional rectification methods cannot achieve the maximum power possible due to non-optimal current waveforms. The optimal current waveform for maximizing power density and minimizing machine size and weight in a nonsinusoidal power supply system has been derived, incorporated in a control system, and verified by simulation work.

차량 적용을 위한 열전 소자 최대 전력 추종 제어 비교 (Comparisons on Maximum Power Point Tracking Control of a Thermoelectric Generator on Vehicles)

  • 장요한;정승훈;배성우
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.159-166
    • /
    • 2021
  • This study compares the maximum power point tracking (MPPT) control methods of a thermoelectric generator on vehicles. The researchers conduct comparisons on five different MPPT methods, including a fractional open circuit voltage method, a perturbation and observation (P&O) method, an incremental conductance method, a linear extrapolation-based MPPT (LEMPPT) method, and a LEMPPT/P&O hybrid method. These five MPPT methods are theoretically analyzed in detail, and the comparisons are conducted through MATLAB/Simulink simulation results. The comparison outcomes reveal that linear MPPT methods, including LEMPPT and LEMPPT/P&O hybrid methods, are more suitable for a thermoelectric generator on vehicles than the other MPPT methods examined in this work.

90/150 선형 CA를 이용한 90/102(170)/150 선형 CA 합성 (Synthesis of 90/102(170)/150 linear CA using 90/150 linear CA)

  • 최언숙;조성진;김한두;권민정;김석태
    • 한국전자통신학회논문지
    • /
    • 제11권9호
    • /
    • pp.885-892
    • /
    • 2016
  • 수축수열 생성기라고 하는 비선형 수열 생성기는 최대 주기를 갖는 두 개의 LFSR로 이루어진 비선형 키스트림 생성기이다. 이러한 수축수열 생성기에 의해 생성된 수축수열은 삽입수열로 한 부류에 포함되고, 셀룰라 오토마타(이하 CA)를 이용하여 생성할 수 있다. 본 논문에서는 수축수열의 특성다항식과 동일한 특성다항식을 갖는 90/150 CA 기반의 수열생성기를 합성하는 방법을 제안한다.