• 제목/요약/키워드: line-width

검색결과 1,548건 처리시간 0.025초

종골 길이와 너비의 상관관계를 이용한 종골 너비 추정에 관한 연구 (A Study on the Estimation of Calcaneal Width Using a Correlation of Calcaneal Length and Width)

  • 천동일;황수강;조재호;최성우;김용범;원성훈
    • 대한족부족관절학회지
    • /
    • 제21권2호
    • /
    • pp.61-65
    • /
    • 2017
  • Purpose: The purpose of this study was to determine the correlation and ratio between the calcaneal length and width for predicting the width of calcaneus. Materials and Methods: A total of 190 feet (190 patients) were included based on computed tomography scans. The length of calcaneus (CL) was measured on the line connecting the center of a circle tangent to the cortical margin in the anterior and posterior parts of the calcaneus in a sagittal plane (W1, W2). The width of the calcaneus was defined as the horizontal line of each part (W1, W2, W3) on the same axial plane. The relationship between the measurement was determined through a correlation analysis. The reliability was assessed based on intraclass correlation coefficients. Results: The CL and widths of calcaneus (W1, W2, W3) had a good positive correlation (r=0.848 [W1/CL], r=0.738 [W2/CL], r=0.769 [W3/CL]; p<0.001). The mean CL and widths ratios were 0.33 (W1/CL), 0.37 (W2/CL), and 0.37 (W3/CL). Using these ratios to estimate the widths by multiplying each ratio by the measured calcaneal length, we found a difference between the estimated calcaneal widths and the actual measured calcaneal widths values was 0.25 mm, 0.43 mm, and 0.16 mm. All measurements showed good-to-excellent inter- and intraobserver reliability. Conclusion: This study analyzed the correlation and ratio between the length and width of the calcaneus. The results will help orthopedic surgeons fixate screws in a stable manner to prevent iatrogenic injuries to the medial neurovascular structures of the calcaneus.

X선 CT화상을 이용한 사상체질의 형태학적 특징 파라메타의 제안 (Suggestion of the morphological characteristic parameters according to the Lee's physical constitution theory using X-ray computed tomography)

  • 조봉관;배종일;고병희;제등정남
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 추계학술대회
    • /
    • pp.13-16
    • /
    • 1993
  • In this paper the morphological characteristic parameters according to the Lee's physical constitution theory are suggested using the X-ray computed tomography. The Lee's physical constitution theory is classify into 4 physical constitutional types by the relative degree of visceral function: those are macro-negative(strong liver- weak lung), micro-negative(strong kidney- weak spleen), micro-positive(strong spleen- weak kidney) and macro-positive(string lung- weak liver). The morphological characteristic parameters are the following. The AA-line is the distance between Rt. & Lt. acupuncture point keug-cheun. The BB-line is the length of lung. The CC-line is the longest width of thorax. The DD-line is the vertical distance between the CC-line and the EE-line. The EE-line is the distance between the Rt. and Lt. anterior superior iliac spines. As the results macro-negative(strong liver-weak lung) has the longest CC-line and the short BB-line. Micro-negative(strong kidney-weak spleen) has the longest EE-line and the short CC-line. Micro-positive(strong spleen-weak kidney) has the longest DD-line and the short BB-line. And macro-positive(strong lung-weak kidney) has the longest BB-line and the short EE-line.

  • PDF

두 개의 링-공진기를 갖는 Balun-BPF의 소형화 (Miniaturization of Dual Ring Balun-BPF)

  • 강성준;황희용
    • 한국전자파학회논문지
    • /
    • 제20권2호
    • /
    • pp.129-134
    • /
    • 2009
  • 본 논문에서는 semi-lumped line을 이용하여 기존의 두 개의 링-공진기로 구성된 Balun-BPF를 소형화 시켰다. 기존의 Ring Balun-BPF는 두 개의 링 공진기의 사용, 손실을 줄이기 위한 임피던스가 낮은 선로의 사용과 $\lambda/4$ 전송선로 인버터의 사용으로 회로의 면적이 크다는 문제점을 가지고 있다. Semi-lumped line 구조를 이용하여 링 공진기를 소형화 하였고, 용량성 성분의 보충을 위하여 링 공진기 안쪽에 삼각형 패치를 추가해 줌으로써 구조적 효율성을 높여주었다. 제작된 balun-BPF는 평형 출력단간 대칭적인 출력 특성을 보였으며, 1/4로 소형화 되었다.

위상특성을 이용한 공진기의 외적 양호도(Qe) 추출 방법 (Extracting Method of External Quality Factor(Qe) Using Phase Response)

  • 박영배;김기래
    • 한국정보통신학회논문지
    • /
    • 제15권10호
    • /
    • pp.2065-2071
    • /
    • 2011
  • 본 논문에서는 마이크로스트립 선로 공진기와 입출력 단자의 결합 위치에 따른 공진기의 외적 양호도를 위상 특성을 이용하여 구하는 방법을 제시한다. 마이크로파 필터 설계에서 단자 접속 구조로 많이 이용되는 접합 선로 구조와 결합 선로 구조에 대해 단자의 위치와 선로의 폭과 간격에 따른 결과를 제시한다. 이 방법으로 정확한 $Q_e$ 값을 얻을 수 있었고, 이 결과는 결합공진기 필터 설계에 응용될 수 있다.

Fault Diagnosis Method of Voltage Sensor in 3-phase AC/DC PWM Converters

  • Kim, Hyung-Seop;Im, Won-Sang;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권3호
    • /
    • pp.384-390
    • /
    • 2012
  • This paper proposes a fault diagnosis method of the line-to-line voltage sensors in 3-phase AC/DC pulse width modulation (PWM) converters. The line-to-line voltage sensors are an essential device to obtain the information of the grid voltages for controlling the 3-phase AC/DC PWM converters. If the line-to-line voltage sensors are mismeasured by various faults, the voltage sensors can obtain wrong information of the grid voltage. It has an adverse effect on the control of the converter. Therefore, the converter causes the unbalance input AC current and the DC-link voltage ripple in the 3-phase AC/DC PWM converter. Hence, fast fault detection and fault tolerant control are needed. In this paper, the fault diagnosis method is proposed and verified through simulations and experiments.

FIB를 이용한 다이아몬드 기판 위의 나노급 미세 패턴의 형상 가공 (Nano-scale Patterning on Diamond substrates using an FIB)

  • 송오성;김종률
    • 한국산학기술학회논문지
    • /
    • 제7권6호
    • /
    • pp.1047-1055
    • /
    • 2006
  • 필드이온빔(FIB) 가공기를 써서 초고강도의 벌크다이아몬드를 가공하기 위해 이온 소오스의 종류와 가공 조건에 따른 나노급 미세 선폭의 최적조건을 알아보고 이에 근거한 2차원적인 텍스트의 가공과 3차원적인 박막요소의 가공을 시도하였다. 다이아몬드 기판과 실리콘 기판을 Ga과 $H_2O$ 소오스를 이용하는 FIB를 써서 30 kV 빔 전류를 10 pA $\sim$ 5 nA로 변화시키면서 패터닝하고 이때 각각 20 ${\mu}m$ 길이로 생성되는 선형 패턴의 선폭, 깊이, 에치속도, 에치형상, 깊이선폭비 (aspect ratio)를 확인하였다. 다이아몬드도 실리콘 기판과 마찬가지로 나노급 패턴의 형성이 가능하였다. $H_2O$ 소오스를 채용한 경우가 에치 깊이가 2배 정도 증가하였으며 동일한 가공 조건에서는 실리콘에 비해 다이아몬드의 에치 선폭이 감소는 경향이 있었다. 특히 다이아몬드는 절연성 때문에 차지가 축적되어 가공 중 이온빔이 불안정해지는 문제가 있었으나 차지 중화 모드를 이용하여 성공적으로 sub-100 nm급 선폭의 미세 가공이 가능하였다. 확인된 선폭가공 조건에 근거하여 2차원적으로 0.3carat의 보석용 다이아몬드의 거들부에 300여개의 글자를 FIB를 활용하여 선폭 240 nm정도로 명확히 기록하는 것이 가능하였다. $Ga^+$이온과 30 eV-30 pA로 조건에서 비교적 넓은 선폭과 Z축 depth 고정범위에서 많은 개인정보의 기록이 영구적으로 가능하였으며 전자현미경으로 재생이 가능하였다. 3차원적으로 두께 $1{\mu}m$의 박막요소를 FIB가공과 백금 용접으로 떼어낸 후 FIB가공으로 두께가 100 nm가 되도록 한 후 투과전자현미경을 이용하여 성분 분석을 하는 것이 성공적으로 수행될 수 있었다.

  • PDF

2급 와동의 복합레진 충전에 관한 유한요소법적 응력분석 (FINITE ELEMENT STRESS ANALYSIS OF A CLASS II COMPOSITE RESIN RESTORATION)

  • 송보경;엄정문
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.627-643
    • /
    • 1995
  • The resistance to fracture of the restored tooth may be influenced by many factors, among these are the cavity dimension and the physical properties of the restorative material. The placement of direct composite resin restorations has generally been found to have a strengthening effect on the prepared teeth. It is the purpose of this investigation to study the relationship between the cavity isthmus and the fracture resistance of a tooth in composite resin restorations. In this study, MO cavity was prepared on the maxillary left first molar and then filled with composite resin. Three dimentional model with 3049 nodes and 2450 8-node blick elements was made by the serial photographic method and isthmus (1/4, 1/3, 1/2 and 2/3 of intercusplal distance between mesiobuccal cusp tip and mesiolingual cusp tip) was varied. Two types of model(B and R model) were developed. B model was assumed perfect bonding between the restoration and cavity wall and R model was left unfilled. A load of 1500N was applied vertically on the node from the lingual slope of the mesiobuccal cusp. The results were as follows : 1. There was a significant decrease of stress resulting in increase of fracture resistance in B model when compared with R model. 2. When it comes to stress distribution, the stress was concentrated in the facio-gingival line angle and the buccal side of the distal margin of the cavity in both Band R model. 3. With the increase of the isthmus width, the stress decreased in the area of the facio-gingival line angle, and increased in the area of facio-gingival line angle as well as the buccal side of the distal margin of the cavity in B model. In R model, the stress increased both in the area of facio-gingival line angle and the buccal side of the distal margin of the cavity, therefore the possibility of crack increased. 4. As the width of cavity increased, in B model, the direction of crack moved from horizontal to vertical on the facio-gingival line angle and the facio-pulpal line angle. In R model, the direction of the crack was horizontal on the facio-gingival line angle and moved from horizontal to the $45^{\circ}$ direction on the facio-pulpal line angle.

  • PDF