• Title/Summary/Keyword: line test

Search Result 4,445, Processing Time 0.031 seconds

Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator (수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가)

  • Hwang, D.H.;Kim, J.B.;Kim, Y.J.;Park, M.S.;Kim, T.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Ultimate Strength of Concrete Barrier by the Yield Line Theory

  • Jeon, Se-Jin;Choi, Myoung-Sung;Kim, Young-Jin
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.1
    • /
    • pp.57-62
    • /
    • 2008
  • When the yield line theory is used to estimate the ultimate strength of a concrete barrier, it is of primary importance that the correct assumption is made for the failure mode of the barrier. In this study, a static test was performed on two full-scale concrete barrier specimens of Korean standard shape that simulate the actual behavior of a longitudinally continuous barrier. This was conducted in order to verify the failure mode presented in the AASHTO LRFD specification. The resulting shape of the yield lines differed from that presented in AASHTO when subjected to an equivalent crash load. Furthermore, the ultimate strengths of the specimens were lower than the theoretical prediction. The main causes of these differences can be attributed to the characteristics of the barrier shape and to a number of limitations associated with the classical yield line theory. Therefore, a revised failure mode with corresponding prediction equations of the strength were proposed based on the yield lines observed in the test. As a result, a strength that was more comparable to that of the test could be obtained. The proposed procedure can be used to establish more realistic test levels for barriers that have a similar shape.

Efficient Code-based Software Product Line Regression Testing (효율적인 소프트웨어 제품라인 회귀시험을 위한 자동화된 코드 기반 시험 방법)

  • Jung, Pilsu;Kang, Sungwon
    • Journal of Software Engineering Society
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2020
  • Software product line development is a development paradigm that efficiently develops a product family by avoiding redundant development based on separation of the common part and the variable part of the product family. In software product line development, the source code that is used to produce a product family is called a product line code base, and when the product line code base is changed and the products of the product family are affected by the change, the activity of testing the affected products is called a product line regression testing. For product line regression testing, instead of conducting regression testing individually on each product of the product family, a more efficient regression testing would be possible if unnecessary testing that are irrelevant to the change can be avoided. This paper introduces SRTS, which is an automated method to efficiently perform software product line regression testing. SRTS divides the product line code base and test cases based on commonality and variability. Then SRTS identifies and selects the test cases affected by the change. Finally, it reduces unnecessary testing by rerunning only the selected test cases.

The Incidences of Catheter Colonization and Central Line-Associated Bloodstream Infection According to Tegaderm vs. Chlorhexidine Gluconate (CHG)-Tegaderm Dressing (중심정맥관 번들이행에 따른 중심정맥관 균집락과 중심정맥관 관련 혈류감염: CHG테가덤과 일반테가덤 드레싱비교연구)

  • Kim, Eunji;Lee, Haejung
    • Journal of Korean Academy of Nursing
    • /
    • v.50 no.4
    • /
    • pp.541-553
    • /
    • 2020
  • Purpose: In spite of the recent application of a general infection control method, central line-associated infections is still relatively high in Korea. Central line bundle with Chlorhexidine gluconate (CHG) tegaderm dressing was reported to be effective in reducing catheter colonization and central line-associated bloodstream infections (CLABSI). Therefore, this study aimed to examine the incidences of catheter colonization occurrence and CLABSI while using Tegaderm vs. CHG Tegaderm dressings. Methods: We used a descriptive design. 400 patients who had central venous catheters were selected from four hospitals in the Korean National Healthcare-associated Infections Surveillance System. Of all subjects, 200 used Tegaderm™ (Tegaderm group), and the remaining 200 used CHG Tegaderm (CHG Tegaderm group) dressing at the catheter insertion site. Data were analyzed using the χ2 test or Fisher's exact test, t-test, and logistic regression analysis using SPSS WIN 21.0. Results: In the Tegaderm and CHG Tegaderm groups, CLABSI incidences were 5.89 and 1.79 per 1,000 catheter-days, catheter colonization incidences were 3.93 and 1.43 per 1,000 catheter-days, and central line bundle compliance rates were 26.0% and 49.0%, respectively. Catheter colonization risk factors were 'reinsertion after failure' and 'Tegaderm dressing' at the central line insertion site. CLABSI risk factors were 'incomplete performance of 7 central line bundle items' and 'Tegaderm dressing' at the central line insertion site. Conclusion: A further prospective study is needed to examine the effects of central line bundle with CHG Tegaderm dressing, avoiding central line reinsertion after failure, and improving the bundle compliance in reducing catheter colonization and CLABSI.

A Study on the Stress Corrosion Cracking Behaviors for Weld Joint of Steel with Various pH Values in Synthetic Sea Water (인공해수의 pH에 따른 강 용접부의 응력 부식균열거동에 관한 연구)

  • 유효선;나의균;정세희
    • Journal of Welding and Joining
    • /
    • v.13 no.1
    • /
    • pp.78-88
    • /
    • 1995
  • This paper was performed to study the utility of the SP(small punch) test and the AE(acoustic emission) test in the evaluation of SCC(stress corrosion cracking) susceptibility for parent metal and bond line of HT80 steel-weld joint by SAW(submerged arc welding) with the various pH values. The loading rate used was 3*10$^{-4}$ mm/min and the corrosive environment used was synthetic sea water during the SP test and the AE test. According to the test results, the SCC susceptibility of the parent metal was increased in the order of pH6.0, pH8.2 and pH10.0. On the other hand, the bond line showed almost the same high SCC susceptibility in all pH concentrations. Synthetically, from the results of the SCC susceptibility, the macro- and micro-SEM observation, the microfracture behaviors by AE test and the relationship between SCC susceptibility and displacement at incipient failure, .delta.$_{i.f-AE}$, it can be concluded that the SP test and the AE test are the good test methods to evaluate the SCC susceptibility for parent metal and bond line of the weld joint with the change of environmental factors.

  • PDF

Evidence gathering for line based recognition by real plane

  • Lee, Jae-Kyu;Ryu, Moon-Wook;Lee, Jang-Won
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.195-199
    • /
    • 2008
  • We present an approach to detect real plane for line base recognition and pose estimation Given 3D line segments, we set up reference plane for each line pair and measure the normal distance from the end point to the reference plane. And then, normal distances are measured between remains of line endpoints and reference plane to decide whether these lines are coplanar with respect to the reference plane. After we conduct this coplanarity test, we initiate visibility test using z-buffer value to prune out ambiguous planes from reference planes. We applied this algorithm to real images, and the results are found useful for evidence fusion and probabilistic verification to assist the line based recognition as well as 3D pose estimation.

  • PDF

Formability Study on Weld Line Location and Movement of Laser-Tailor Welded Blanks

  • Hong, Joo-Pyo;Kim, Heon-Young;Oh, Soo-Ik
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.19-24
    • /
    • 1997
  • The weld line location and the weld line movement in stamping with laser-tailor welded blanks(TWB) were investigated through square cup deep drawing tests. The step blank holder was introduced to form TWB of different thicknesses without wrinkling, and the non-uniform blank holding force(BHF) was enforced to control weld line movement. Test results of the blanks with shifted weld lines showed that the large portion of the thinner area could result in a large weld line movement. Careful selection of the weld line location and the BHF control should be adapted in TWB design to avoid failures and to ensure its formability.

  • PDF

Transferred OverVoltages on LV sides in Multigrounded Neutral during Line to Ground Fault on Distribution Systems (배전계통의 고저압 혼촉고장시 중성선 전위상승에 따른 저압기기 스트레스 전압)

  • Choi, Sun-Kyu;Choi, Jong-Kee;Kim, Kyoung-Hun;Choi, Myeong-Ho;Lee, Byung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.910-915
    • /
    • 2012
  • In this paper we propose multi-grounded neutral design method which was considered of transferred transient overvoltage when line to neutral fault occurs. Specially, In order to confirm the actual transient overvoltage magnitude which occurs on neutral line, we considered some screening(shielding) effects. The screening coefficient was deducted from field test results and calculation in a distribution line which is identical with an actual power line. The purpose of this paper is to attempt to suggest the guidance for grounding skystem design considering limitation of overvoltage for LV side in IEC 61936. The result is based on EMTP simulation and real field faults situation in distribution lines.

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.

Hypothesis Tests For Performances of a New Spline Interpolation Technique (신 스플라인보간법의 퍼포먼스 가설점정)

  • Yu, Ki-Yun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.7 no.1 s.13
    • /
    • pp.29-40
    • /
    • 1999
  • In vector GIS, natural linear entities (called linear entitles) are usually represented by a set of line segments. As an alternative of the line segments, curve segments can be used to represent the linear entities. The curve segments, as one-dimensional spatial objects, we generated by spline interpolation technique such as Bezier technique. In an effort to improve its accuracy in resembling the linear entities, the Bezier technique was modified generating a new technique (called New technique) (Kiyun, 1998). In this paper, validity of the New technique was tested. Test focused on answering two questions: (1) whether or not the curve segments from the New technique replace line segments so as to enhance the accuracy of representations of linear entities, and (2) whether or not the curve segments from the New technique represent the linear entities more accurately than curve segments from the Bezier technique. Answering these two questions entailed two hypothesis tests. For test data, a series of hydrologic lines on 7.5-minute USGS map series were selected. Test were done using t-test method and statistical inferences were made from the results. Test results indicated that curve segments from both the Bezier and New techniques represent the linear entities more accurately than the line segments do. In addition, curve segments from the New technique represent the linear entities more accurately than the line segments from the Bezier technique do at probability level 69% or higher.

  • PDF