• Title/Summary/Keyword: line reliability

Search Result 1,093, Processing Time 0.027 seconds

Running safety evaluation of tilting vehicle when speed-up in curved track of conventional line (기존선 곡선선로에서 한국형 틸팅열차의 속도향상시 주행안전성 평가)

  • Ham, Young-Sam;Lee, Dong-Hyong;Kwon, Seok-Jin;Seo, Jung-Won;Jun, Hyun-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.25-29
    • /
    • 2010
  • Safety of railroad is result of reliability which is received from test & evaluation of system. Railroad system is consisted of various sub system such as vehicle, supply of electric power, signal, communication, rail track construction, operation. To secure safety of railroad, evaluation about parts, assembly, sub system, whole system etc.. that compose railroad is essential. In this paper, I wish to describe for results that analyze korean tilting vehicle's derailment coefficient developed by national research achievement. Confirmed that is possible even if speed up, curved line department running speed that estimate korean tilting vehicle's running safety in curved line track of Jungang Line about 20 km/h than present operating speed.

  • PDF

A Study on Constructing the Prediction System Using Data Mining Techniques to Find Medium-Voltage Customers Causing Distribution Line Faults (특별고압 수전설비 관리에 데이터 마이닝 기법을 적용한 파급고장 발생가능고객 예측시스템 구현 연구)

  • Bae, Sung-Hwan;Kim, Ja-Hee;Lim, Han-Seung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2453-2461
    • /
    • 2009
  • Faults caused by medium-voltage customers have been increased and enlarged their portion in total distribution faults even though we have done many efforts. In the previous paper, we suggested the fault prediction model and fault prevention method for these distribution line faults. However we can't directly apply this prediction model in the field. Because we don't have an useful program to predict those customers causing distribution line faults. This paper presents the construction method of data warehouse in ERP system and the program to find customers who cause distribution line faults in medium-voltage customer's electric facility management applying data mining techniques. We expect that this data warehouse and prediction program can effectively reduce faults resulted from medium-voltage customer facility.

Waterhammer for In-line Booster Pump (직결식 펌프의 수격현상)

  • Kim, Sang-Gyun;Lee, Gye-Bok;Kim, Kyung-Yup
    • The KSFM Journal of Fluid Machinery
    • /
    • v.8 no.6 s.33
    • /
    • pp.7-14
    • /
    • 2005
  • The waterhammer occur when the pumps are started or stopped for the operation or tripped due to the power failure, and the hydraulic transients take place as a result of the sudden change in velocity. Several times, the field tests of the waterhammer were carried out for Pangyo booster pumping station. Pangyo pumping station was installed with the booster pumps of 6 sets and the in-line pumps of 2 sets. The in-line pumps are additionally needed to the surge suppression device so that the pumping station acquire the safety and reliability for the pressure surge.

The Shape Optimization of TCP to Reduce the Line Defects of LCD Module (액정 디스플레이(LCD)의 선 결함 발생 저감을 위한 TCP 형상 최적화)

  • Park, Sang-Hu;Lee, Bu-Yun;Kim, Won-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.140-145
    • /
    • 2001
  • The tape carrier package(TCD) is one of the most important components in a liquid crystal display(LCD) module. It has a role to transmit electrical signals from a printed circular board(PCB) to a display panel. If TCP is damaged under mechanical shock, the signals can not be transmitted to the panel and as a result, some dead lines are generated on the panel. This kind of phenomenon is commonly called as 'line defects'. In this paper, new structural design concepts of TCP are proposed to guarantee its reliability by using Taguchi's approach and dynamic FE-analysis. The line defects problem of TCP module is solved by replacing the original TCP with the newly designed one.

  • PDF

A Modeling and Simulation Implementation on the Power Line Disturbances by Loss of Contact for the High-Speed Railway Vehicle (고속전철 주행시 이선에 따른 전원외란 현상 모델링 및 시뮬레이션 구현)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young;Gimm, Yoon-Myoung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1137-1142
    • /
    • 2008
  • In this paper, an effect on power conversion unit in high-speed railway vehicle by loss of contact between a catenary system and pantograph suppling electrical power to high-speed railway vehicle are investigated. One of the most important needs accompanied by increasing the speed of high-speed railway vehicle is reduced that arc phenomenon by loss of contact brings out EMI. in case of high-speed railway vehicle using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occur. To analysis the effect on loss of contact, it is necessary electrical modeling system between the contact line and the pantograph according to the loss of contact. Therefore analytical model of a contact line and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on kinds of loss of contact.

  • PDF

Analysis of Characteristics of the HEMP Coupling Signal for a Line Over Ground (접지면 위 도선에 대한 고고도 전자기 펄스 신호의 결합 특성 분석)

  • Lee, Jin-Ho;Kwon, Joon-Hyuck;Shin, Guy-Beom;Kang, Rae-Choong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1172-1179
    • /
    • 2010
  • Since HEMP has the very short rising time and propagates widespreadly with several tens of kV/m, it threatens most of systems in its cover range. Therefore, it is important to research coupling mechanism into systems and establish countermeasures for the HEMP to protect systems effectively. This paper analyzed characteristics and trends of currents to be induced at the load of a line which is located over ground with different conditions such as polarization, incidence angle, line length and height etc. We applied double exponential waveform as the HEMP shape and used BLT method to analyze the coupling route into the line. Also, we compared the simulation data of chain matrix modeling to verify reliability of BLT modeling. In the result, two data is almost agreed.

Development of a Live-line Insulator Inspection Tool System for 154 kV Power Transmission Lines

  • Lee, Jae-Kyung;Park, Joon-Young;Cho, Byung-Hak;Oh, Ki-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 2012
  • The current paper deals with a new live-line insulator inspection tool system that will be used by the Korea Electric Power Corporation for its 154 kV power transmission lines in 2011. Unlike the existing contact type tools, the developed inspection tool automates parts of the insulator inspection process using a sensor and an actuator. The tool sustains its weight independently, not by a lineman. In addition, the inspection tool measures the insulation resistance of an insulator together with its distribution voltage, thus providing more information for analysis and diagnosis. Such characteristics improve the system's operation efficiency, measurement reliability, and usability. We confirmed its effectiveness through live-line field tests with actual power transmission lines.

An Improvement of Digital Distance Relay Reliability using Neural Networks (신경회로망을 이용한 디지털 거리계전기의 신뢰도 향상)

  • Lee, Myoung-Soo;Lee, Jae-Gyu;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.949-951
    • /
    • 1998
  • Because of the zero sequence mutual coupling of parallel lines, the distance calculation performed by a distance relay is incorrect. To achieve correct operation, the relay has to use not only the measured quantities of faulty line, but also the zero sequence current of healthy line. But the zero sequence current of the healthy line cannot be always measured. Therefore, we propose the neural network method to estimate the zero sequence current and the criterion to determine whether faulty line or not.

  • PDF

A Study of Line-Interactive UPS with Voltage Compensator (Line-Interactive 전압보상기에 관한 연구)

  • Woo Sung-Min;Kang Dae-Wook;Lee Woo-Cheol;Choi Chang-Ho;Hyun Dong-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.487-490
    • /
    • 2001
  • Power Quality and Reliability are becoming important issues for critical and sensitive loads. This paper describes the Line Interactive UPS with the function of Voltage Compensator that is 'Line interactive Dynamic Voltage Restorer(LIDVR). The main purpose of a LIDVR is to compensate for voltage sag(dip), outage and overvoltage. The overall system consists of three controller 1) current controller with prediction 2) voltage controller and 3) proposed variable DC LINK controller. The variable DC LINK control technique using the LIDVR protects DC LINK from overflowing the input current. The simulation results are depicted in this paper to show the effect of this proposed system.

  • PDF

Development of Bridge Inspection Reliability and Improvement Strategy (교량 점검신뢰도 분석법 개발과 향상방안)

  • Jeong, Yo-Seok;Kim, Woo-Seok;Lee, Il-Keun;Lee, Jae-Ha
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.50-57
    • /
    • 2016
  • The present study proposed three inspection reliability indices which compared inspection results evaluated at in-depth(routine) inspection and in-depth safety inspection; Nominal inspection reliability index, Real inspection reliability index, and DS nominal inspection reliability index. The methods to improve the inspection reliability were also proposed. Since bridge inspection process is critical to ensuring the safety of bridges and identifying repair and maintenance needs, the quality of the inspection data produced from the inspection process is very important. Consequently, the inspection reliability indices were suggested to evaluate quality of current inspection practices. Specifically, approximately 85% of inspection errors evaluated by the DS nominal inspection reliability index are within 1 rating grade(equal to or less than damage score ${\pm}0.1$). In order to improve the inspection reliability, transportation agency should implement QC(Quality Control) practices and develop professional expertises of inspectors by higher requirements for inspectors, on-off line inspection training and etc.