• Title/Summary/Keyword: line position measurement

Search Result 182, Processing Time 0.025 seconds

Novel Impedance Method for Analyzing Truncal Obesity (중심성 비만 분석을 위한 새로운 임피던스 해석법)

  • Lim, Taek-Gyun;Seo, Kwang-Seok;Jeong, In-Cheol;Jun, Suk-Hwan;Noh, Yeon-Sik;Kim, Eung-Seok;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.849-856
    • /
    • 2009
  • Truncal obesity associated with insulin resistance and metabolic syndrome increase the likelihood of hypertension, various cardiovascular diseases, hyperlipidemia and coronary heart diseases. International Diabetes Federation (IDF) experts recognized that it is necessary to develop the simple diagnostic tool which is applicable to diagnose truncal obesity worldwide, and proposed the method using a waist circumference but there is a limit to estimate subcutaneous fat distribution. However, waist line is also influenced by total fat capacity less than the intra abdominal fat. The more having severe obesity, the more correlation coefficient between waist line and intra abdominal fat is low. Therefore, this thesis defines a new abdominal impedance measurement position and impedance-index to analysis central obesity. This proposes the new model to estimate abdominal obesity using the abdominal impedance-index and CT images acquired fro 160 Korean subjects. The proposed model shows that the abdominal fat distribution has a higher correlation than waist line. (Adj R2=0.809, 0.667 and 0.687 with abdominal fat area, visceral fat area and subcutaneous fat area respectively).

Measurement of Target Objects Based on Recognition of Curvature and Plane Surfaces using a Single Slit Beam Projection (슬릿광 투영법을 이용한 곡면과 평면의 식별에 의한 대상물체의 계측)

  • Choi, Yong-Woon;Kim, Young-Bok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.5 no.5
    • /
    • pp.568-576
    • /
    • 1999
  • Using a laser sheet beam projector combined with a CCD-Camera, an efficient technique to recognize complex surface of curvature and lane has been demonstrated for the purpose of mobile robot navigation. In general, obstacles of indoor environments in the field of SLIT-RAY plane are captured as segments of an elliptical arc and a line in the camera image. The robot has been capable of moving along around the obstacle in front of it, by recognizing the original shape of each segment with the differential coefficient by means of least squares method. In this technique, the imaged pixels of each segment, particularly elliptical arc, have been converted into a corresponding circular arc in the real-world coordinates so as to make more feasible the image processing for the position and radius measurement than conventional way based on direct elliptical are analyses. Advantages over direct elliptical cases include 1) higher measurement accuracy and shorter processing time because the circular arc process can reduce the shape-specifying parameters, 2) no complicated factor such as the tilt of elliptical arc axis in the image plane, which produces the capability to find column position and radiua regardless of the camera location . These are essentially required for a mobile robot application. This technique yields an accuracy less than 2cm for a 28.5cm radius column located in the range of 70-250cm distance from the robot. The accuracy obtained in this study is sufficient enough to navigate a cleaning robot which operates in indoor environments.

  • PDF

A Study on the Risk Assessment Method of Indoor-Impulsive Noise (실내 충격소음 위험 평가 방법에 관한 연구)

  • Chung, Sung Hak;Song, Ki Hyeok
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.90-97
    • /
    • 2016
  • The objective of this study is to evaluate the operator's safety for the risk assessment method of impulsive noise division. Literature reviews on the basis of the impulsive noise study, the measuring methods and procedures, based on the results of the analysis process presents a risk assessment methods. In this study, analysis of the MIL-STD-1474D, B-duration graph for the peak noise level to cross the line from the measurement results is limited by the risk retracted. It is possible to determine whether there is quick can be determined whether the risk. Measurement positions measured by the microphone is installed on the risk of applying results are so located within the tolerance impulsive noise in the measurement position can interpret subjective safety is ensured. In addition, Proportional Dose technology was the proposed by the Patterson with the risk assessment method was applied to the indoor-impulsive noise. As results of this study, results for the same value of applying the technique of Proportional Dose technology results calculated by MIL-STD-1474D methods allows 1 count once increased in comparison to the result obtained.

Experimental Study of Spacecraft Pose Estimation Algorithm Using Vision-based Sensor

  • Hyun, Jeonghoon;Eun, Youngho;Park, Sang-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.263-277
    • /
    • 2018
  • This paper presents a vision-based relative pose estimation algorithm and its validation through both numerical and hardware experiments. The algorithm and the hardware system were simultaneously designed considering actual experimental conditions. Two estimation techniques were utilized to estimate relative pose; one was a nonlinear least square method for initial estimation, and the other was an extended Kalman Filter for subsequent on-line estimation. A measurement model of the vision sensor and equations of motion including nonlinear perturbations were utilized in the estimation process. Numerical simulations were performed and analyzed for both the autonomous docking and formation flying scenarios. A configuration of LED-based beacons was designed to avoid measurement singularity, and its structural information was implemented in the estimation algorithm. The proposed algorithm was verified again in the experimental environment by using the Autonomous Spacecraft Test Environment for Rendezvous In proXimity (ASTERIX) facility. Additionally, a laser distance meter was added to the estimation algorithm to improve the relative position estimation accuracy. Throughout this study, the performance required for autonomous docking could be presented by confirming the change in estimation accuracy with respect to the level of measurement error. In addition, hardware experiments confirmed the effectiveness of the suggested algorithm and its applicability to actual tasks in the real world.

A Study on the Basic Bodice Pattern for the Fatty Body -The subject of middle-aged women- (비만체형을 위한 기본 Bodice 원형연구 -중년기 부인을 중심으로-)

  • 한애미
    • Journal of the Korean Home Economics Association
    • /
    • v.25 no.3
    • /
    • pp.15-26
    • /
    • 1987
  • The purpose of this study was to develop the pattern drafting method which would be suitable to their physical characteristics for the fatty body of 40∼55 aged Korean women who are more than 1.5 Rohrer's Index and 90㎝ bust girth. The study was composed as follows; 1. Body measurement and statistical analysis: One hundred and thirty women were measured on 29 items. Thirty-four items including 29 measured items and 5 calcutated items were analyzed statistically. 1) Mean, standard deviation, variance, maximum, minimum, range were computed. 2) Correlation coefficients between each items were computed. 2. Development of new bodice pattern drafting method: Measurement items necessary to draft new bodice pattern were bust girth, center back waist length, shoulder width, back width, chest and neck base girth. The new pattern was examined through three wearing tests for completion. 3. Evaluation of the new pattern drafting method: The new pattern was objectively evaluated by the sensory test. The sensory evaluation was applied to evaluate the new pattern for the fatty body women by comparint it with the conventional patterns. The results of sensory tests of the new pattern are as follows: 1) The composite reliability coefficient is 0.7698, and the reliability of sensory test shows high. 2) According to a statistical analysis of the result of the 23 items on the questionaire, all the items showed significant differences(α 0.01) between the two, with the new pattern having higher scores. The new pattern is better conventional pattern as the average mark of the former is 3.901 but that of latter is 2.926. The new pattern drafting method proved to be superior to the conventional one especially in the fitness at the center front neck point, shoulder point, side line, armscye depth, position of bust point, chest width line, under arm dart and the shoulder line.

  • PDF

Maneuvering Target Tracking With 3D Variable Turn Model and Kinematic Constraint (3D 가변 선회 모델 및 기구학적 구속조건을 사용한 기동표적 추적)

  • Kim, Lamsu;Lee, Dongwoo;Bang, Hyochoong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.881-888
    • /
    • 2020
  • In this paper, research on estimation of states of a target of interest using Line Of Sight(LOS) angle measurement is performed. Target's position, velocity, and acceleration are chosen to be the states of interests. The LOS measurement is known to be highly non-linear, making target dynamic modeling hard to be implemented into a filter. To solve this issue, the Pseudomeasurement equation was applied to the LOS measurement equation. With the help of this equation, 3D variable turn target dynamic model is applied to the filter model. For better performance, Kinematic Constraint is also implemented into the filter model. As for the filter, Bias Compensation Pseudomeasurement Filter (BCPMF) is used which is known for its robustness to initial conditions. Moreover, Two-Stage Kalman Filter (TSKF) form was also implemented to benefit from the parallel computation. As a result, TBCPMF 3DVT-KC is proposed and simulated to assess performance.

Inspection of the Nuclear Fuel Rod Deformation using an Image Processing (영상처리를 이용한 핵연료봉의 변형 검사)

  • Cho, Jai-Wan;Choi, Young-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.1
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a deformation measurement technology of the nuclear fuel rod is proposed. The deformation measurement system include high definition CCD or CMOS image sensor, lens, semiconductor laser line beam marker, and optical & mechanical accessories. The basic idea of the deformation measurement is to illuminate the outer surface of the fuel rod with collimated laser line beam at an angle of 45 degrees or higher. The relative motion of the fuel rod in the horizontal direction causes the illuminated laser line beam to move vertically along the surface of the fuel rod. The resulting change of laser line beam position in the surface of the fuel rod is imaged as the parabolic beam in the high definition CCD or CMOS image sensor. From the parabolic beam pattern, the ellipse model is extracted. And the slope of the long and the short axis of the ellipse model is found. The crossing point between the saddle point of the parabolic beam and the long & short axis of the ellipse model is taken as the feature of the deformed fuel rod. The vertical offset between feature points before and after fuel rod deformation is calculated. From the experimental results, $50\;{\mu}m$ inspection resolution is acquired using the proposed method, which is three times enhanced than the conventional criterion ($150\;{\mu}m$) of the guide for the inspection of the nuclear fuel rod.

Implementation of 3D Road Surface Monitoring System for Vehicle based on Line Laser (선레이저 기반 이동체용 3차원 노면 모니터링 시스템 구현)

  • Choi, Seungho;Kim, Seoyeon;Kim, Taesik;Min, Hong;Jung, Young-Hoon;Jung, Jinman
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.101-107
    • /
    • 2020
  • Road surface measurement is an essential process for quantifying the degree and displacement of roughness in road surface management. For safer road surface management and quick maintenance, it is important to accurately measure the road surface while mounted on a vehicle. In this paper, we propose a sophisticated road surface measurement system that can be measured on a moving vehicle. The proposed road surface measurement system supports more accurate measurement of the road surface by using a high-performance line laser sensor. It is also possible to measure the transverse and longitudinal profile by matching the position information acquired from the RTK, and the velocity adaptive update algorithm allows a manager to monitor in a real-time manner. In order to evaluate the proposed system, the Gocator laser sensor, MRP module, and NVIDIA Xavier processor were mounted on a test mobile and tested on the road surface. Our evaluation results demonstrate that our system measures accurate profile base on the MSE. Our proposed system can be used not only for evaluating the condition of roads but also for evaluating the impact of adjacent excavation.

Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thickness Measurement Techniques

  • Lim, One-Bin;Hong, Ji-A;Yi, Chung-Hwi;Cynn, Heon-Seock;Jung, Doh-Heon;Park, Il-Woo
    • Physical Therapy Korea
    • /
    • v.18 no.4
    • /
    • pp.60-67
    • /
    • 2011
  • Ultrasonography (US) is a recent technique that has proven to be useful for assessing muscle thickness and guiding the rehabilitation decision-making of clinicians and researchers. The purpose of this study was to determine the inter-rater reliability of the US measurement of transversus abdominis (TrA), internal oblique (IO), and external oblique (EO) thicknesses for different probe locations and measurement techniques. Twenty healthy volunteers were recruited in this study. Muscle thicknesses of the transversus TrA, IO, and EO were measured three times in the hook-lying position. The three different probe locations were as follows: 1) Probe location 1 (PL1) was below the rib cage in direct vertical alignment with the anterior superior iliac spine (ASIS). 2) Probe location 2 (PL2) was halfway between the ASIS and the ribcage along the mid-axillary line. 3) Probe location 3 (PL3) was halfway between the iliac crest and the inferior angle of the rib cage, with adjustment to ensure the medial edge of the TrA. The two different techniques of thickness measurement from the captured images were as follows: 1) Muscle thickness was measured in the middle of the muscle belly, which was centered within the captured image (technique A; TA). 2) Muscle thickness was measured along a horizontal reference line located 2 cm apart from the medial edge of the TrA in the captured image (technique B; TB). The intraclass correlation coefficient (ICC [3,k]) was used to calculate the inter-rater reliability of the thickness measurement of TrA, IO and EO using the values from both the first and second examiner. In all three muscles, moderate to excellent reliability was found for all conditions (probe locations and measurement techniques) (ICC=.70~.97). In the PL1-TA condition, inter-rater reliability in the three muscle thicknesses was good to excellent (ICC=.85~.96). The reliability of all measurement conditions was excellent in IO (ICC=.95~.97). Therefore, the findings of this study suggest that TA can be applied to PL1 by clinicians and researchers in order to measure the thickness of abdominal muscles.

Shock-Wave Oscillation in a Supersonic Diffuser -Displacement Measurement of Mormal Shock-Wave- (초음속 디퓨져에서 충격파의 진동 (1) -수직충격파의 순간변위 측정-)

  • 김희동;엄용균;권순범
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.933-945
    • /
    • 1994
  • A shock-wave in a supersonic flow can be theoretically determined by a given pressure ratio at upstream and downstream flowfields, and then the obtained shock-wave is stable in its position. Under the practical situation in which the shock-wave interacts with the boundary layer along a solid wall, it cannot, however, be stable even for the given pressure ratio being independent of time and oscillates around a time-mean position. In the present study, oscillations of a weak normal shock-wave in a supersonic diffuser were measured by a Line Image Sensor(LIS), and they were compared with the data of the wall pressure fluctuations at the foot of the shock-wave interacting with the wall boundary layer. LIS was incorporated into a conventional schlieren optical system and its signal, instantaneous displacement of the interacting shock-wave, was analyzed by a statistical method. The results show that the displacement of an oscillating shock-wave increase with the upstream Mach number and the dominant frequency components of the oscillating shock-wave are below 200 Hz. Measurements indicated that shock-wave oscillations may not entirely be caused by the boundary layer separation. The statistical properties of oscillations appeared, however, to be significantly affected by shock-induced separation of turbulent boundary layer.