• Title/Summary/Keyword: line position measurement

Search Result 182, Processing Time 0.026 seconds

A CEPHALOMETRIC STUDY OF KOREAN CHILDREN BY RICKETTS' ANALYSIS (리켓츠 분석을 이용한 한국인 아동의 두부방사선 계측학적 연구)

  • Yang, Kyu-Ho;Kim, Seon-Mi
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.430-440
    • /
    • 1998
  • This study was performed to establish the cephalometric standards and to compare measurement of Korean children in the Field I, II, III, IV, V, VI to Japanese and Caucasians by the Ricketts' analysis. Lateral cephalograms of 24 males and 27 females with normal occlusion and acceptable profile 9 years of age were obtained and statistically analyzed. 1. Norms of Korean males, females and both sexes at 9 years old were established. 2. Significant differences between male and female exist in incisor overjet, maxillary incisor protrusion, mandibular incisor inclination, cranial deflection, corpus length. Maxillary incisor of male was more protrude and overjet was larger than female 3. Korean was similar to Japanese but different from Caucasian. Compare with facial axis and facial depth, chin was retruded dolichofacial pattern and due to large mandibular plane angle and small corpus length, mandibular plane was inclined and mandible body was short. Compare with porion location, ramus position and posterior facial height, ramus was long and located posterior. Compare with maxillary depth and maxillary height, maxilla was located posterior and inferior. The distance between the upper molar and PTV was short, the amount of distalization is limited. Maxillary and mandibular incisor were more protruded and also lower lip was more protruded to esthetic line 4. In comparison between 9 and 11 years old, growth changes of facial depth, mandibular plane angle, corpus length and upper molar position were larger than that of Japanese and Caucasians.

  • PDF

A Study on the Correlationship between Wearable ECG and Clinical ECG Measurements (웨어러블 심전도 측정과 임상 심전도 측정과의 상관관계에 대한 연구)

  • Lee, Kang-Hwi;Lee, Seong-Su;Kim, Sang-Min;Lee, Hyeok-Jae;Min, Kyoung-Jin;Kang, Hyun-Kyu;Lee, Joo-Hyeon;Kwak, Hwy-Kuen;Ko, Yun-Soo;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1690-1698
    • /
    • 2018
  • Recent advances in ICT technology have transformed many of our daily lives and attracted a lot of attention to personal health. Heart beat measurement that reflects cardiac activities has been used in various fields such as exercise evaluation and psychological state evaluation for a long time, but its utilization method is limited due to its differentiation from clinical electrocardiogram. Therefore, in this study, we could observe the change of the measured signal according to the change of the distance and the position of the measuring electrodes which are non-standard electrode configuration. Based on the electric dipole model of the heart, correlation with clinical electrocardiogram could be confirmed by synthesizing multiple surface potentials measured with a shorter electrode distance than standard one. From the electromagnetic point of view, the distance between the measuring electrodes corresponds to the distance that the electric potential by the cardiac electric dipole moves, and the electric potential measured at the body surface is proportional to the moving distance of the electric potential. Therefore, it is preferable to make the distance between electrodes as long as possible, and to position the measuring electrode close to the ventricle rather than the atrium. In addition, it was found that standard electrocardiographic waveforms could be synthesized by using arithmetic sum of multiple measuring electrodes due to the relationship of electrical dipole vectors, which is obtained by dividing and positioning a plurality of measuring electrodes on a reference electrode line, such as Lead-I, Lead-II direction. Also, we obtained a significant Pearson correlation coefficient ($r=0.9113{\pm}0.0169$) as a result of synthetic experiments on four subjects.

AE source on-line localization on material with unknown acoustic wave propagation velocity (전파속도를 알수 없는 재료에서의 AE 발생위치 온라인 측정)

  • Jhang, Kyung-Young;Lee, Weon-Heum;Kim, Dal-jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.688-694
    • /
    • 1998
  • The ability to locate the defects in materials is one of the major attrations of the acoustic emission(AE) technique. The most conventional method for planar AE source localization is to place three or more AE sensors on the plate and to determine the source position by measuring the differences in the arrival times of the AE wave at the sensors, which is called as triangulation method. But this method can not be applied in the material of which elastic wave propagtion velocity is not known. In this paper, we propose two methods, vector method and error minimization method, for AE source location on the material with unknown AE wave velocity. In this method, it is not needed to know the propagation velocity previously, that is, we can apply this method to arbitrary material of which properties are not known exactly. Also, in this paper, the robustness to the error in the measurement of time differences are discussed for both methods. Finally, in order to evaluate the actual performances, experiments using a pencil lead break as the AE source were carried out on the aluminum plate.

LOS Determination Using INS for an Aircraft Mounted Satellite Tracking Antenna (관성측정기를 이용한 항공기용 위성추적 안테나의 지향각 결정)

  • Jung, Ha-Hyoung;Kim, Chung-Il;Lyou, Joon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.3
    • /
    • pp.12-18
    • /
    • 2012
  • This paper presents a computation method of LOS(Line Of Sight) angle using IMU(Inertial Measurement Unit) for an antenna on aerial vehicle to point to a stationary satellite. In the overall system, the antenna is located at the front of the vehicle, and an IMU is introduced to account for body flexure dynamic. And using the differences between the position and velocity of the IMU based navigation and those of GPS/INS at the vehicle center. Kalman filter is designed to suppress Strapdown INS drift errors.

A Study on Indoor Air Quality Monitoring System for Subway Stations (지하역사의 공기질 감시 시스템 구성에 관한 연구)

  • Lee, Byung-Seok;Hwang, Sun-Ju;Lee, Joon-Hwa;Kim, Gyu-Sik;Kim, Jo-Chun
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.48-50
    • /
    • 2009
  • This paper presents an IAQ(Indoor Air Quality) Monitoring System using equipments for measurement of fine Particle($PM1{\sim}PM10$), $CO_2$, VOCs(Volatile Organic Compounds), temperature and humidity for IAQ monitoring of subway station which millions of people use a day. The necessity of IAQ monitoring system is getting increased for more effective subway station monitoring in line with the recent government's regulation for IAQ is reinforcing. Subway Station is an unusual case. The structure of subway station is closed and complicated. Therefore when data of equipments are transferred, transmission error can happen occasionally. To prevent transmission error, an IAQ Monitoring System is needed the appropriate position and selection of equipments or sensor module. In addition IT(Information Technology) can be utilized like "WiBro(Wireless Broadband)" and "GateWay" for facilitate movement of data and construction of IAQ monitoring system of subway station.

  • PDF

A Newly Designed Contact Profiler for Microstructure (새로운 구조의 접촉식 미세구조 프로필러)

  • Choi, Dong-Jun;Choi, Jai-Seong;Choi, In-Mook;Kim, Soo-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.3
    • /
    • pp.39-45
    • /
    • 2002
  • A simple and low cost stylus profiler made of ferrite cores is developed. The devised profiler consists of a contact probe, a measuring transducer, a signal processing unit, and a motorized stage. The contact probe attached to 4-bar spring maintains sufficient stiffness to protect disturbances. An overlap-area type inductive position sensing system is selected as a measuring transducer, which has high sensitivity, repeatability and linearity. The transducer is composed of coil bundles and ferrite cores which have good electromagnetic characteristics in spite of low cost. The repeatability of the profiler with the proposed inductive sensing system is better than 50nm. Experimental results are shown that the proposed profiler can measure the line or 3D profile of an object with sub-micron features.

Temperature Dependence of Excitonic Transitions in GaN Grown by MOCVD

  • Guangde Chen;Jingyu Lin;Hongxing Jiang;Kim, Jung-Hwan;Park, Sung-Eul
    • Journal of Photoscience
    • /
    • v.7 no.1
    • /
    • pp.27-30
    • /
    • 2000
  • The Photoluminescence (PL) measurement results of a very good quality GaN sample grown by metalorganic chemical vapor deposition (MOCVD) are reported. The temperature dependences of peak position, emission intensity, and the full width at half maximum (FWHM) of free-exciton (FX) A and B are presented. Our results show the fast thermal quenching of FX transition intensities and predominantly acoustic phonon scattering of emission line broadening. The transition-energy-shift following the Varshni's empirical equation, and by using it to fit the data, E$\_$A1/(T) = 3.4861 eV -6.046 $\times$ 10$\^$-4/T$^2$ (620.3+ T) eV, E$\_$B1/(T) = 3.4928 eV -4.777 $\times$ 10$\^$-4/T$^2$ / (408.2+ T) eV and E$\_$A2/ = 3.4991 eV -4.426 $\times$ 10$\^$-4/ T$^2$ / (430.6+ T) eV for A(n=1), B(n=1), and A(n=2) are obtained respectively.

  • PDF

Development of Vision Sensor Module for the Measurement of Welding Profile (용접 형상 측정용 시각 센서 모듈 개발)

  • Kim C.H.;Choi T.Y.;Lee J.J.;Suh J.;Park K.T.;Kang H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.285-286
    • /
    • 2006
  • The essential tasks to operate the welding robot are the acquisition of the position and/or shape of the parent metal. For the seam tracking or the robot automation, many kinds of contact and non-contact sensors are used. Recently, the vision sensor is most popular. In this paper, the development of the system which measures the profile of the welding part is described. The total system will be assembled into a compact module which can be attached to the head of welding robot system. This system uses the line-type structured laser diode and the vision sensor It implemented Direct Linear Transformation (DLT) for the camera calibration as well as radial distortion correction. The three dimensional shape of the parent metal is obtained after simple linear transformation and therefore, the system operates in real time. Some experiments are carried out to evaluate the performance of the developed system.

  • PDF

Cooperative Standoff Tracking of a Moving Target using Decentralized Extended Information Filter (이동 목표물 협력추적을 위한 다수 무인항공기의 분산형 확장정보필터 설계)

  • Yoon, Seung-Ho;Bae, Jong-Hee;Kim, You-Dan
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.11
    • /
    • pp.1013-1020
    • /
    • 2011
  • This paper deals with the tracking problem of a moving target using multiple unmanned aerial vehicles. A decentralized extended information filter is designed to cooperatively estimate the position and the velocity of the moving target. The extended information filter is adopted to consider the range and the line-of-sight angle as measurement data. The decentralized scheme is applied to enhance the estimation performance using the information provided by other vehicles. Numerical simulation is performed to verify the tracking performance of the proposed decentralized filters.

Quantum Secret Sharing Scheme with Credible Authentication based on Quantum Walk

  • Li, Xue-Yang;Chang, Yan;Zhang, Shi-Bin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.7
    • /
    • pp.3116-3133
    • /
    • 2020
  • Based on the teleportation by quantum walk, a quantum secret sharing scheme with credible authentication is proposed. Using the Hash function and quantum local operation, combined with the two-step quantum walks circuit on the line, the identity authentication and the teleportation of the secret information in distribution phase are realized. Participants collaborate honestly to recover secret information based on particle measurement results, preventing untrusted agents and external attacks from obtaining useful information. Due to the application of quantum walk, the sender does not need to prepare the necessary entangled state in advance, simply encodes the information to be sent in the coin state, and applies the conditional shift operator between the coin space and the position space to produce the entangled state necessary for quantum teleportation. Security analysis shows that the protocol can effectively resist intercept/resend attacks, entanglement attacks, participant attacks, and impersonation attacks. In addition, the quantum walk circuit used has been implemented in many different physical systems and experiments, so this quantum secret sharing scheme may be achievable in the future.