• Title/Summary/Keyword: line monitoring

Search Result 1,487, Processing Time 0.025 seconds

Investigation of On-line Monitoring Method on 1500 V Direct Current Cable of Subway

  • Shen, Xiaojun;Jiang, Xiuchen;Yi, Zeng
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.247-251
    • /
    • 2006
  • The traction DC feeder cable is one of the key devices for the safety operation of subway system, but for low voltage DC feeder cable (<3000 V) for subway, little attention has been paid by investigators on its online monitoring technology. With an introduction of cable laying and operation environment for the cable, this paper investigated the on-line monitoring technology of 1500 V DC feeder cable of subway. Firstly, in the text, the fault model of 1500 V DC cable was proposed based on the analysis of the fault type of the DC feeder cable, and then put forward synthetically on-line monitoring discharge signal and DC leakage current signal to assess DC feeder cable insulating state. The results of laboratory experiment prove that the proposed methods are feasible and can be implemented on-line monitor on DC feeder cable of subway.

Monitoring of Temperature and Strain Variation with FBG Sensors (FBG 센서를 활용한 온도와 스트레인 변화 모니터링)

  • Ko, Ki-Han;Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Cho, Yong-Suk;Choi, Won-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.3
    • /
    • pp.218-221
    • /
    • 2009
  • This paper reports on measurement method for the fiber optic strain monitoring of overhead contact line systems of trains, We used FBG (Fiber Bragg Grating) sensors to measure the strain variation of overhead contact line. FBG sensors can sensitively measure the variation of strain and! or temperature by the shift wavelength of reflected wave according to the lattice variation during the measurement. FBG sensor were attached on the contact line and connected to the monitoring system with optical fibers. The monitering system with FBG sensors showed very good sensitivity to measuring strain variation and this system could be applied to the overhead contact line of KTX (Korea Train eXpress).

Realization of a virtual Instrumentation system for On-Line LIM Performance Monitoring (유도형 리니어모터 성능의 온$\cdot$라인 모니터링을 위한 가상계측시스템 구현)

  • Jang, Seok-Myeong;Lee, Sung-Ho;Chang, Kun-Woo;Jeong, Sang-Sub
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.205-213
    • /
    • 2001
  • This paper presents a virtual instrumentation(VI) system for LIMs performance on-line monitoring. The VI is designed using the graphical programming language LabVIEW and is capable of performing on-line measurement functions, including data acquisition, display, and analyses in the time and frequency domains, as well as data archiving. To monitor in real time the steady-state and transient electromagnetic thrust of LIMs, the search coil is used for the determination of the flux linkage components, which is then multiplied by the appropriate current components to yield a signal proportional to the electromagnetic thrust. This paper reports the LIM's dynamics measured by the proposed on-line monitoring system.

  • PDF

In-situ Blockage Monitoring of Sensing Line

  • Mangi, Aijaz Ahmed;Shahid, Syed Salman;Mirza, Sikander Hayat
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.98-113
    • /
    • 2016
  • A reactor vessel level monitoring system measures the water level in a reactor during normal operation and abnormal conditions. A drop in the water level can expose nuclear fuel, which may lead to fuel meltdown and radiation spread in accident conditions. A level monitoring system mainly consists of a sensing line and pressure transmitter. Over a period of time boron sediments or other impurities can clog the line which may degrade the accuracy of the monitoring system. The aim of this study is to determine blockage in a sensing line using the energy of the composite signal. An equivalent Pi circuit model is used to simulate blockages in the sensing line and the system's response is examined under different blockage levels. Composite signals obtained from the model and plant's unblocked and blocked channels are decomposed into six levels of details and approximations using a wavelet filter bank. The percentage of energy is calculated at each level for approximations. It is observed that the percentage of energy reduces as the blockage level in the sensing line increases. The results of the model and operational data are well correlated. Thus, in our opinion variation in the energy levels of approximations can be used as an index to determine the presence and degree of blockage in a sensing line.

Development of a Remote Central Monitoring System of Street Lights (가로등 원격감시 중앙관제시스템 개발)

  • Ha, Kwan-Yong;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.43-45
    • /
    • 2004
  • A remote monitoring system was developed to improve inconveniences of manual work such as monitoring street lights by using current sensors, microprocessor and RF communication system. In order to control the street lights on the roads effectively and monitor them in real time, we can attach current sensor to the street lights which monitors Lamp, the broken part and state of the Balast, and the amount of an electric leak precisely we developed a system which makes it possible to transmit the data on monitoring results in breakdown of street lights and Balasts to the central monitoring computer without setting up extra data transmission line. The system we devised can transmit data through Power Line Modem and RF communication using relay method to the central controlling computer without any loss of data.

  • PDF

Development of Central Monitoring System for Insulation Diagnosis of High-Voltage Generator/Motor Stator Windings (고압 회전기 고정자 권선의 절연진단을 위한 중앙 집중 감시 시스템 개발)

  • Shin, Byoung-Chol;Yoon, Dae-Hee;Hwang, Don-Ha;Kim, Yong-Joo;Ju, Young-Ho;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1906-1908
    • /
    • 2000
  • The central monitoring system with on-line diagnosis of high-voltage generator/motor stator insulation is developed. The system is capable of remote diagnosis and monitoring partial discharges of high-voltage generator/motor stator insulation. GOMS(Generator On-line Monitoring System) with maximum of 9 input channels can measure and analyze the status of high-voltage motor stator insulation by on-line. The measured and analysis data are brought to the central monitoring system via modem to build database. The central monitoring system can diagnose and monitor the insulation status of several high-voltage generator/motor at any time. The insulation status of those machines can be enhanced by the database on partial discharges.

  • PDF

On-line Monitoring of Tribology Parameters and Fault Diagnosis for Disc Brake System

  • Yang Zhao-Jian;Kim Seock-Sam
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.224-228
    • /
    • 2003
  • The basic Principles and methods of the on-line monitoring of tribology parameters (friction coefficient and wear allowance) and fault diagnosis for the hoist disc brake system were introduced, the method were based on the spring force and oil pressure of the brake system and the hoist kinematics parameters. The experiment on the monitoring and diagnosis of hoist brake system were carried out. The research results showed: the monitoring and diagnosis methods are feasible.

  • PDF

The Development Plan of Voltage Security On-Line Monitoring System (전압안전성 온라인 감시시스템의 개발방안)

  • Jeon, D.H.;Kweon, S.G.;An, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1173-1175
    • /
    • 1998
  • This paper presented the development plan of voltage security on-line monitoring system (VSECOMs). VSECOMs consists of voltage security monitoring system and data management system. VSECOMs has the function of bus voltage watch. voltage stability analysis, and voltage security assessment. EMS data on-line acquisition, PSS/E file conversion, and overall data management. VSECOMs is designed with client/server structure. We will seek stable operation of KEPCO's power system by installation of VSECOMs in EMS of KEPCO.

  • PDF

Development of On-line Condition Monitoring Program of a Turboprop Engine (터보프롭 엔진의 온라인 상태감시 프로그램 개발에 관한 연구)

  • Kong, Chang-Duk;Kim, Keon-Woo;Lim, Se-Myung;Kim, Ji-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.05a
    • /
    • pp.295-299
    • /
    • 2010
  • Recently, development and application of the condition monitoring and diagnostic system for improvement of durability and reliability and reduction of operating cost is generalized in the aircraft propulsion system. Especially, for reliable operation of the UAV which is flying in high altitude more than 40,000 ft for a long time an condition monitoring system to identify faults and degradations of its propulsion system should be needed. Therefore, this work proposes an on-line condition monitoring program using MATLAB/SIMULINK. In the development phase of the program, a engine signal generation module is used to simulate real engine measuring parameters instead of the real engine. The proposed on-line condition monitoring program was applied to a real turboprop engine to validate its application capability.

  • PDF

Feasibility of RF Sensor Application for On-line Monitoring of Tomato Paste Processing (토마토 패이스트 가공공정의 온라인 모니터링용 RF 센서의 활용 가능성)

  • Kim, Seong-Min;Garvey, Casey;Leary, Thomas;McCarthy, Michael
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.410-415
    • /
    • 2008
  • On-line monitoring of fresh tomato paste processing was done using two radio frequency (RF) sensors resonant at 85 and 110 MHz. Fresh tomato juice with soluble solid content of about $5^{\circ}Brix$ was evaporated up to $23^{\circ}Brix$ and diluted down to about $5^{\circ}Brix$ again with a pilot scale evaporator. The RF sensors were installed in a processing pipe and monitored. The pastes at a specific $^{\circ}Brix$ level were sampled and analyzed for physical properties such as soluble solid content and viscosity. The relationships between sensor outputs and measured physical properties were analyzed. Analysis results showed RF sensor is feasible to apply on-line monitoring of tomato paste processing.