• 제목/요약/키워드: line loads

검색결과 473건 처리시간 0.04초

3상 4선식 저압 배전선로에서 선형 및 비선형 부하의 사용시 전압 불평형률 비교 분석 (Comparative Analysis of Voltage Unbalance Factor on the use of Linear and Non-linear loads in Three-phase Four-wire Low Voltage Distribution Line)

  • 김종겸;김지명
    • 전기학회논문지
    • /
    • 제66권3호
    • /
    • pp.587-592
    • /
    • 2017
  • In the three-phase four-wire low-voltage power distribution equipment, single-phase and three-phase load have been used mainly mixed. Also linear and nonlinear loads have been used together in the same conditions. In a three-phase four-wire distribution line, the current distribution of three-phase linear load is almost constant in each phase during driving or stopping, but the single-phase load is different from each other for each phase in accordance with the operation and stop. So that the voltage unbalance is caused by the current difference of each phase. In the three-phase four-wire distribution system, non-linear load is used with linear load. The presence of single-phase nonlinear loads can produce an increase in harmonic currents in three-phase and neutral line. It can also cause voltage unbalance. In the present study, we analyzed for the voltage unbalance fluctuations by the operation pattern of the single and three-phase linear and non-linear load in three-phase four-wire low voltage distribution system.

모터부하를 고려한 ON-LINE 안정도 해석 (Power System Stability Analysis Considering Motor Loads)

  • 박지호;백영식;이희춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.316-318
    • /
    • 2000
  • In this paper. we have simulated the transient stability of power system with motor loads. In study of power system stability, modelling of motors is required for the system with large concentrations of motors. Therefore the dynamics attributable to motors are usually the most significant aspects of dynamics characteristics of system loads. A synchronous motor is modelled as a dynamic load. We investigate the effect of synchronous motors of Kwang Yang network with three phase fault.

  • PDF

철도하중에 대한 콘크리트 슬래브궤도의 피로거동에 관한 실험적 연구 (Experimental Investigation on Fatigue Behavior of Concrete Slab Tracks under Railway Loads)

  • 강보순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.639-642
    • /
    • 2003
  • In this paper, fatigue behavior of concrete slab tracks under railway loads by experimental method is discussed. The addition of steel fibers to concrete mix has been receiving more attention as a way of improving the crack behavior of concrete beams an slabs tacks. This study two objectives: 1) to observe the fatigue behavior of fiber reinforced concrete slab in labor, and 2) to present crack propagation and deflection of fiber reinforced concrete slab track under railway loads in the Waghauser test line. Nine beams, two slabs and one test track were experimentally tested.

  • PDF

다양한 평가 지표와 최적화 기법을 통한 오염부하 산정 회귀 모형 평가 (Evaluation of Regression Models with various Criteria and Optimization Methods for Pollutant Load Estimations)

  • 김종건;임경재;박윤식
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2018년도 학술발표회
    • /
    • pp.448-448
    • /
    • 2018
  • In this study, the regression models (Load ESTimator and eight-parameter model) were evaluated to estimate instantaneous pollutant loads under various criteria and optimization methods. As shown in the results, LOADEST commonly used in interpolating pollutant loads could not necessarily provide the best results with the automatic selected regression model. It is inferred that the various regression models in LOADEST need to be considered to find the best solution based on the characteristics of watersheds applied. The recently developed eight-parameter model integrated with Genetic Algorithm (GA) and Gradient Descent Method (GDM) were also compared with LOADEST indicating that the eight-parameter model performed better than LOADEST, but it showed different behaviors in calibration and validation. The eight-parameter model with GDM could reproduce the nitrogen loads properly outside of calibration period (validation). Furthermore, the accuracy and precision of model estimations were evaluated using various criteria (e.g., $R^2$ and gradient and constant of linear regression line). The results showed higher precisions with the $R^2$ values closed to 1.0 in LOADEST and better accuracy with the constants (in linear regression line) closed to 0.0 in the eight-parameter model with GDM. In hence, based on these finding we recommend that users need to evaluate the regression models under various criteria and calibration methods to provide the more accurate and precise results for pollutant load estimations.

  • PDF

Influence of second order wave excitation loads on coupled response of an offshore floating wind turbine

  • Chuang, Zhenju;Liu, Shewen;Lu, Yu
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.367-375
    • /
    • 2020
  • This paper presents an integrated analysis about dynamic performance of a Floating Offshore Wind Turbine (FOWT) OC4 DeepCwind with semi-submersible platform under real sea environment. The emphasis of this paper is to investigate how the wave mean drift force and slow-drift wave excitation load (Quadratic transfer function, namely QTF) influence the platform motions, mooring line tension and tower base bending moments. Second order potential theory is being used for computing linear and nonlinear wave effects, including first order wave force, mean drift force and slow-drift excitation loads. Morison model is utilized to account the viscous effect from fluid. This approach considers floating wind turbine as an integrated coupled system. Two time-domain solvers, SIMA (SIMO/RIFLEX/AERODYN) and FAST are being chosen to analyze the global response of the integrated coupled system under small, moderate and severe sea condition. Results show that second order mean drift force and slow-drift force will drift the floater away along wave propagation direction. At the same time, slow-drift force has larger effect than mean drift force. Also tension of the mooring line at fairlead and tower base loads are increased accordingly in all sea conditions under investigation.

비정상 상태의 선접촉 탄성유체윤활 유막두께 및 유막압력 특성연구 (Study on the Film Thickness and Pressure of the Transient Line Contact Elastohydrodynamic Lubrication)

  • 조재철;장시열
    • Tribology and Lubricants
    • /
    • 제25권5호
    • /
    • pp.335-341
    • /
    • 2009
  • Elastohydrodynamic lubrication (EHL) analysis shows that film thickness is very flat in the contact area and pressure distribution is somehow similar to that of Hertzian contact pressure except the outlet region with pressure spike. These typical patterns of EHL film thickness and pressure are the cases under the steady contact conditions of applied loads and speeds. However, many engineering contacts are rather under the conditions of varying loads and contact speeds, and therefore the predictions for endurance life and performance of machine elements with steady EHL analysis are not suitable in many occasions. This study shows the differences in film thickness formation and pressure distribution between steady and transient contact conditions in several contact cases.

다점지지 계류시스템의 정적해석에 대한 연구 (A Study on the Analysis of Multi-let Spread Mooring Systems)

  • 신현경;김덕수
    • 한국해양공학회지
    • /
    • 제9권2호
    • /
    • pp.53-60
    • /
    • 1995
  • A multi-leg spread mooring system for floating offshore structures is important, but the multi-leg static analysis is complicated due to the nonlinear behavior of each line and the effect of current which affects each line differently. The pretensioned position of the multi-leg mooring system obtained from the static equilibrium condition changes into a different position due to external loads and current. In this paper, the new position and the static tension at each line are caculated. The relation between the initial static equilibrium position and the new position due to the external loads is expressed in terms of the Taylor's series expansion. The Runge-Kutta $4^{th}$ method is employed in analyzing the 3-dimensional static cable nonlinear equations.

  • PDF

친환경 Ultra-capacitor에 의한 순시전압강하의 직렬전압보상 시스템 (Series Voltage Compensation Systems for Voltage Sag by Using an Environmentally Friendly Ultra-capacitor)

  • 손진근;전희종
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.763-769
    • /
    • 2009
  • A series voltage compensation(SVC) system is a power-electronics controller that can protect sensitive loads from disturbance in the supply system. Especially, voltage sags are considered the dominant disturbances affecting the power quality. This paper dealt with a system of off-line type voltage sag compensation by using a bi-directional DC/DC converter of environmentally friendly ultra-capacitor. This capacitor is attached to the DC link of SVC through the high-efficiency DC/DC converter in order to compensate the DC link voltage drop during short-term power interruption as voltage sags. Therefore, in this paper, a DC/DC converter to control high-efficiency energy of ultra-capacitor and voltage sag detection algorithm of off-line type SVC systems are newly introduced. According to the results of experimental of prototype system, it is verified that the proposed system has effectiveness of voltage sag compensation using an ultra-capacitor.

태양광 발전시스템의 네가티브 컨덕턴스를 이용한 계통연계형 인버터 (Grid-Connected Inverter Using the Negative Conductance of Photovoltaic Power System)

  • 이창희;박기락;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.45-48
    • /
    • 2002
  • This paper proposes a grid-connected inverter using the negative conductance of PV power system, which has four IGBTs and simple controller. Most of modern electric loads generate the current harmonics and the line voltage distortion. The new solar-to-ac converter(STAC) provides by emulating a negative conductance load to the line voltage, so the current harmonics from STAC is canceled the effect of the harmonics from other loads. As a result, the line voltage distortion is decreased. The proposed system have low cost, small size, and light weight compared to conventional photovoltaic converter

  • PDF

Air Line 임피던스 표준을 이용한 동축형 부하의 임피던스 정밀 측정 (Precise Impedance Measurement of Coaxial Loads using Air Line Impedance Standards)

  • 강진섭;김정환
    • 한국전자파학회논문지
    • /
    • 제11권5호
    • /
    • pp.788-795
    • /
    • 2000
  • 본 논문에서는 offset open과 offset short를 반사 표준으로 사용하고 길이가 다른 여러개의 reference air line을 임피던스 표준으로 사용한 동축형 부하의 임피던스 정밀 측정법을 제안했다. 5~1,000MHz 주파수영역에서 SWR bridge(5~400MHz)와 벡터 회로망분석기(100~1,000MHz)를 사용하여 얻은 power sensor와 thermistor mount의 입력 임피던스를 제시했다.

  • PDF