• Title/Summary/Keyword: line impedance measurement

Search Result 138, Processing Time 0.026 seconds

Branch line directional coupler with coupled lines (결합 선로를 이용한 브랜치 선로 방향성 결합기)

  • Han, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.2
    • /
    • pp.286-291
    • /
    • 2011
  • Directional couplers are widely used in RF and microwave applications to distribute or monitor signals. This paper presented a new structure of microstrip branch line directional coupler with coupled lines. The loose couplings of microstrip branch line directional couplers are impractical for the high characteristic impedance values required for the shunt branches. To overcome this limitation, the parallel coupled lines with the shorts were used for the high characteristic impedance. The results of the simulations and measurements were presented for the proposed branch line directional coupler. Measurement of the 10 dB branch line directional coupler shows that the return loss is higher than 30 dB over 10 % bandwidth and the isolation is 35 dB or better over 8 % bandwidth.

Relative Measurement of Differential Electrode Impedance for Home Healthcare Device (Home Healthcare 장치를 위한 차동 전극 임피던스의 상대적인 측정)

  • Woo, Y.J.;Yoo, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.469-470
    • /
    • 2007
  • In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the body potential driving circuit, and no electrical safety problem, can be achieved using this method. Furthermore, this method can be applied to multi-channel isolated bio-potential measurement systems and home health care devices under a steady measuring environment.

  • PDF

Approximate Method of Transmission Lines Crossing a Rectangular Aperture in a Backplane (백 플레인의 사각형 개구를 관통하는 전송 선로의 근사 해석법)

  • Jung, Sung-Woo;Choi, Beom-Jin;Choi, Bong-Yeol;Kim, Ki-Chai
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.1056-1064
    • /
    • 2010
  • This paper presents the approximate analysis method for the symmetric transmission line crossing the aperture in an backplane. The method of moments is used to determine the aperture impedance for the construction of the equivalent transmission line that the aperture impedance apply to the transmission line as the shunt impedance. As the results, the insertion loss increases at the specific frequency range for the impedance matching. In the case of the mismatching, we are confirmed to the insertion gain at the specific frequency. Also the horizontal length of the aperture affects to the transmission line better than vertical length. The measurement of the insertion loss is performed to verify the theoretical analysis.

Stepped Impedance LPF Using MCS Line with Ground (접지가 있는 MCS 선로를 이용한 스텝 임피던스 저역 필터)

  • Rhee, Seung-Yeop;Lee, Yong-Kook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1248-1253
    • /
    • 2008
  • The MCS(Micro-Coplanar Strip) line with ground has been analyzed. The conformal mapping method is used to calculate the quasi-static effective dielectric constant and characteristic impedance of this MCS line. The computed results of the present work are found to be in good agreement when compared with the results obtained using commercial S/W, IE3D. And in this paper, the stepped-impedance low pass filter is designed and fabricated with MCS lines for improving the frequency responses. The LPF proposed structure has been also designed and implemented to have the sharp attenuation characteristics in stop band. The agreement between simulation and measurement results verify the implemented LPF.

Calculation of the Characteristic Impedance of Transmission Lines with Periodic Structures (주기구조가 결합된 전송선로의 특성 임피던스 계산)

  • Lim, Jong-Sik;Lee, Jae-Hoon;Lee, Jun;Han, Sang-Min;Ahn, Dal
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.7
    • /
    • pp.2541-2548
    • /
    • 2010
  • This paper describes the calculation for characteristic impedance of transmission line with periodic structures such as defected ground structure (DGS) and photonic bandgap (PBG). The previous method which uses the ${\lambda}$/4 transmission line model is reviewed and its disadvantage that the calculated characteristic impedance is strongly dependent on the frequency is discussed. The characteristic impedance of transmission lines with periodic structures are calculated using the ${\lambda}$/4 transmission line model and analytic method. The calculated characteristic impedance by the latter method is an almost constant value while that from the first method depends on the frequency strongly. In addition, the characteristic impedance of the transmission line with PBG is calculated and proposed, while it has been rarely studied ever. S-parameters are obtained from the measurement using the fabricated sample as well as simulation, and used for calculating the characteristic impedances and comparison. The characteristic impedances calculated from the measured S-parameters agree well with the simulated results. It is well described that the analytic method to calculate the characteristic impedance of transmission lines on uniform dielectric structures can be applied successfully to the transmission lines with periodic structures such as DGS and PBG.

Study on Bandwidth and Characteristic Impedance of CWP3DCS (Coplanar Waveguide Employing Periodic 3D Coupling Structures) for the Development of a Radio Communication FISoC (Fully-integrated System on Chip) Semiconductor Device (완전집적형 무선통신 SoC 반도체 소자 개발을 위한 주기적인 3차원 결합구조를 가지는 코프레너 선로에 대한 대역폭 및 임피던스 특성연구)

  • Yun, Young
    • Journal of Navigation and Port Research
    • /
    • v.46 no.3
    • /
    • pp.179-190
    • /
    • 2022
  • In this study, we investigated the characteristic impedance and bandwidth of CPW3DCS (coplanar waveguide employing periodic 3D coupling structures), and examined its potential for the development of a marine radio communication FISoC (fully-integrated system on chip) semiconductor device. To extract bandwidth and characteristic impedance of the CPW3DC, we induced a measurement-based equation reflecting measured insertion loss, and compared the measured results of the propagation constant β and characteristic impedance with the measured ones. According to the results of the comparison, the calculated results show a good agreement with the measured ones. Concretely, the propagation constant β and characteristic impedance exhibited an maximum error of 3.9% and 6.4%, respectively. According to the results of this study, in a range of LT = 30 ~ 150 ㎛ for the length of periodic structures, the CPW3DC exhibited a passband characteristic of 121 GHz, and a very small dependency of characteristic impedance on frequency. We could realize a low impedance transmission line with a characteristic impedance lower than 20 Ω by using CPW3DCS with a line width of 20 ㎛, which was highly reduced, compared with a 3mm line width of conventional transmission line with the same impedance. The characteristic impedance was easily adjusted by changing LT. The above results indicate that the CPW3DC can be usefully used for the development of a wireless communication FISoC (fully-integrated system on chip) semiconductor device. This is the first report of a study on the bandwidth of the CPW3DC.

Small Loop Antenna for EMI Controlled and Monitoring

  • Khemchan, A.;Khamphakdi, P.;Urabe, Junichiro;Khan-ngern, W.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.470-473
    • /
    • 2004
  • This paper presents conducted emission noise measurement from electronic equipment in frequency range of 1 MHz up to 30 MHz by small loop antenna. Small loop antenna measurement method can measure common-mode (CM) and differential-mode (DM) component of the noise on a pair of power line at the same time. The CM and DM can be measured separately. The theory of this measurement method is introduced and analyzed. The measured results were compared with the conventional measurement by Line Impedance Stabilization Network (LISN) and result a good trend between those methods.

  • PDF

The line impedance calculation and measurement of the underground transmission cable (지중 송전 케이블 선로임피던스 계산 및 실측)

  • Kim, Nam-Yul;Kim, Joung-Yun;Heo, Hoi-Deok;Lee, Su-Kil
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.405-407
    • /
    • 2006
  • The power system analysis based on the accurate impedance of the individual underground cable, which is the inter connected to a large power system, is required. A study on calculation method of impedance allowable current for underground cables. furthermore, various methods of bonding and earthing the sheath have been used for the purpose of eliminating or reducing the sheath losses. the effectes of bonding and earthing must be includied in impedances. therefore, the subject of predicting thermal performance of soil and cable systems has been received increasing attension. for these problems, this paper describes a general formulation of impedance that is based on the effect of crossbonding and earthing of the sheath on the 66kV, 132kV and 220kV underground cable systems. also the work is presented, for calculating the temperature rise of power cable and soil.

  • PDF

Research of an On-Line Measurement Method for High-power IGBT Collector Current

  • Hu, Liangdeng;Sun, Chi;Zhao, Zhihua
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.362-373
    • /
    • 2016
  • The on-line measurement of high-power IGBT collector current is important for the hierarchical control and short-circuit and overcurrent protection of its driver and the sensorless control of the converter. The conventional on-line measurement methods for IGBT collector current are not suitable for engineering measurement due to their large-size, high-cost, low-efficiency sensors, current transformers or dividers, etc. Based on the gate driver, this paper has proposed a current measuring circuit for IGBT collector current. The circuit is used to conduct non-intervention on-line measurement of IGBT collector current by detecting the voltage drop of the IGBT power emitter and the auxiliary emitter terminals. A theoretical analysis verifies the feasibility of this circuit. The circuit adopts an operational amplifier for impedance isolation to prevent the measuring circuit from affecting the dynamic performance of the IGBT. Due to using the scheme for integration first and amplification afterwards, the difficult problem of achieving high accuracy in the transient-state and on-state measurement of the voltage between the terminals of IGBT power emitter and the auxiliary emitter (uEe) has been solved. This is impossible for a conventional detector. On this basis, the adoption of a two-stage operational amplifier can better meet the requirements of high bandwidth measurement under the conditions of a small signal with a large gain. Finally, various experiments have been carried out under the conditions of several typical loads (resistance-inductance load, resistance load and inductance load), different IGBT junction temperatures, soft short-circuits and hard short-circuits for the on-line measurement of IGBT collector current. This is aided by the capacitor voltage which is the integration result of the voltage uEe. The results show that the proposed method of measuring IGBT collector current is feasible and effective.

A Robust Fault Location Algorithm for Single Line-to-ground Fault in Double-circuit Transmission Systems

  • Zhang, Wen-Hao;Rosadi, Umar;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Il-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • This paper proposes an enhanced noise robust algorithm for fault location on double-circuit transmission line for the case of single line-to-ground (SLG) fault, which uses distributed parameter line model that also considers the mutual coupling effect. The proposed algorithm requires the voltages and currents from single-terminal data only and does not require adjacent circuit current data. The fault distance can be simply determined by solving a second-order polynomial equation, which is achieved directly through the analysis of the circuit. The algorithm, which employs the faulted phase network and zero-sequence network with source impedance involved, effectively eliminates the effect of load flow and fault resistance on the accuracy of fault location. The proposed algorithm is tested using MATLAB/Simulink under different fault locations and shows high accuracy. The uncertainty of source impedance and the measurement errors are also included in the simulation and shows that the algorithm has high robustness.