• Title/Summary/Keyword: line detection

Search Result 1,781, Processing Time 0.026 seconds

A Multi-Epoch, Simultaneous Water and Methanol Maser Survey Toward Intermediate-Mass Young Stellar Objects

  • Bae, Jae-Han;Kim, Kee-Tae;Youn, So-Young;Kim, Won-Ju;Byun, Do-Young;Kang, Hyun-Woo;Oh, Chung-Sik
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.83.1-83.1
    • /
    • 2011
  • We report multi-epoch, simultaneous 22 GHz water and 44 GHz Class I methanol maser line survey towards 180 intermediate-mass young stellar objects, including 14 Class 0, 19 Class I objects, and 147 Herbig Ae/Be stars. We detected $H_2O$ and $CH_3OH$ maser emission towards 16 (9%) and 10 (6%) sources with one new $H_2O$ and six new $CH_3OH$ maser sources. The detection rates of both masers rapidly decrease as the central (proto)stars evolve, which is contrary to the trends in high-mass star-forming regions. This suggests that the excitations of the two masers are closely related to the evolutionary stage of the central (proto)stars and the circumstellar environments. $H_2O$ maser velocities deviate on average 9 km s-1 from the ambient gas velocities whereas $CH_3OH$ maser velocities well match with. For both maser emissions, large velocity difference (${\mid}v_{H2O}-v_{sys}{\mid}\;>\; 10kms^{-1}\; and\;{\mid}v_{CH3OH}-v_{sys}{\mid}\;>\;1kms^{-1}$) is mostly confined to Class 0 objects. The formation and disappearance of $H_2O$ maser lines are frequent and the integrated intensities of them change up to two orders of magnitude. In contrast, $CH_3OH$ maser lines usually show no significant change in the intensity, shape, and velocity. This consistent with the previous suggestion that $H_2O$ maser emission originates from the base of an outflow while 44 GHz Class I $CH_3OH$ maser emission arises from the interaction region of the outflow with the ambient gas. The isotropic maser luminosities are well correlated with the bolometric luminosities of the central the objects. The fitted relations are $L_{H2O}=1.71{\ast}10^{-9}(L_{bol})^{0.97}$ and $L_{CH3OH}=1.71{\ast}10^{-10}(L_{bol})^{1.22}$.

  • PDF

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection (홍삼 내공검출을 위한 X-선 영상처리기술)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.457-463
    • /
    • 2002
  • 이 연구는 x-선 투과영상을 이용하여 홍삼의 내공을 검출하기 위하여 수행되었다. 이를 위하여 x-선관에 조사되는 x-ray 양의 차이에 따른 위치별 밝기 값 차이를 보정하고 내공 검출에 적합한 영상처리 알고리즘을 개발하였다. 주요연구 결과를 요약하면 다음과 같다. 1) x-선관에 조사되는 x-ray양은 중심에서 가장자리로 갈수록 감소하며, 이것은 위치에 따른 gray 값의 분포가 달라지게 되는 원인이 되었다. 2) 홍삼을 2치화 하기 위해서는 동일한 x-선 조사강도에서 입력된 원 영상에서 빈 영상을 뺀 감산 영상을 만들어 줌으로써 가능하였다. 3) 조사강도 별 감산영상처리 결과 36kV/4.15mA와 39kV/4.15mA에서는 조사량이 많아서 홈삼 지근 부분의 영상이 손실되는 경우가 발생하였다. 4) 내공 검출을 위해서는 정상부분과 내공부분의 자기 값 차이를 크게 하는 전처리 영상을 만들 필요가 있었고, multiple 감산영상에서 뚜렷한 골짜기가 나타났으나 주근의 내공부분의 밝기값 보다 지근의 정상부분의 자기 값이 더 낮게 나타나 이를 보정하기 위하여 홍삼 위치에 따라 부분 보정된 알고리즘을 개발하였다. 5) x-선관의 놓인 위치에 따라서 내공판정시험 결과 중심에 있을 때에 비해 가장자리에 있을 때는 영상이 일부 손실되었으며, 중심 위치에서 서로 다른 굵기의 홍삼에 대해서는 모두 양호한 결과가 나타났다. 6) 완전한 홈삼으로 내공판정시험 결과 내공주위의 정상부분가지도 일부 내공으로 잘못 검출되었으나 이것을 재차 line profile에 의해 한 라인씩 문턱 값을 설정하여 내공만을 정확하게 판정하는 알고리즘을 개발하였다.양체의 접종작업은 모든 배양실이 인력에 의존하였으며, 배양체를 배지와 분리하여 불필요한 부분을 제거하고 배양작물에 따라 생육정도를 2~3등급으로 구분하여 배양용기의 배지 위에 치상하는 과정으로 수행되었으며, 작업능률은 호접란의 경우 배양병에 25본을 접종하는데 시간당 6병, 심비디움은 원형 플라스크에 25본을 접종하는데 시간당 10병 정도였다. 바. 식물체의 대량증식에 사용되는 플라스크, 배양병, PE용기 등 배양용기의 세척작업은 농원의 1개배양실에서 간이식 세척기, 이 외의 9개배양실은 모두 물에 담겨 두었다가 세제와 브러쉬 등을 사용하여 인력으로 세척하고 있어 생력화 기술개발이 요구되었다.도가 빠를수록 건조속도가 빨라졌으며, 건조에너지도 1,334kcal/kg.water로 비슷하게 소요되었다. 마. 시험구와 대비구의 건감률은 시험구에서 1.08~1.36w.b./h로 나타나 대비구보다 약 9.9~18.3%가 높게 나타났고, 건조에너지는 10.2~14.6%가 절감되었다. 발아율은 열풍온도가 낮을수록 높게 나타났고 시험구가 대비구보다 발아율이 낮게 나타났으며, 동할률 증가량도 원적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성

  • PDF

Cystopexy to Treat Urinary Incontinence Due to Urethral Sphincter Mechanism Incompetence in a Male Dog (수컷 개에서 발생한 요도 조임근 기능 부전에 의한 배뇨실금의 방광 고정술을 이용한 외과적 치료 증례)

  • Yoon, Hun-Young;Shin, Dong-Wook;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.515-518
    • /
    • 2014
  • A castrated male Yorkshire Terrier dog was presented for urinary incontinence and constipation. On physical examination, the dog showed difficult urination. There were no neurological abnormalities and no bacterial detection on urinalysis. Rectal examination revealed a regular, normal-sized prostate. Urethral catheterization was performed easily. Excretory urography and retrograde positive contrast urethrocystography showed displacement of the urinary bladder to the intrapelvic region. There was no evidence of an ectopic ureter. A tentative diagnosis of urethral sphincter mechanism incompetence accompanied with a pelvic bladder was made. Cystopexy was decided to place the urinary bladder to its normal position. The neck of the urinary bladder was anchored to the body wall and prepubic tendon using mattress sutures. Additional sutures were placed to appose the lateral part of the urinary bladder and abdominal wall. A simple interrupted suture was placed to tack the apex of the urinary bladder on the abdominal incision line. A urinary catheter was placed in the urinary bladder to provide post-operative evacuation. The catheter was removed when the dog was able to urinate with minimal straining at 3 days post-operatively. The owner reported that the dogs showed normal urination without straining at 3 days after the catheter was removed. Excretory urography revealed that the urinary bladder was located on its normal position at 2 months post-operatively. Subsequent communication with the owner by telephone revealed that the dog was in good urination at 3 years 11 months post-operatively.

Study on Signal Processing in Eddy Current Testing for Defects in Spline Gear (스플라인 기어부 결함의 와전류검사 신호처리에 관한 연구)

  • Lee, Jae Ho;Park, Tae Sung;Park, Ik Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.3
    • /
    • pp.195-201
    • /
    • 2016
  • Eddy current testing (ECT) is commonly applied for the inspection of automated production lines of metallic products, because it has a high inspection speed and a reasonable price. When ECT is applied for the inspection of a metallic object having an uneven target surface, such as the spline gear of a spline shaft, it is difficult to distinguish between the original signal obtained from the sensor and the signal generated by a defect because of the relatively large surface signals having similar frequency distributions. To facilitate the detection of defect signals from the spline gear, implementation of high-order filters is essential, so that the fault signals can be distinguished from the surrounding noise signals, and simultaneously, the pass-band of the filter can be adjusted according to the status of each production line and the object to be inspected. We will examine the infinite impulse filters (IIR filters) available for implementing an advanced filter for ECT, and attempt to detect the flaw signals through optimization of system design parameters for detecting the signals at the system level.

Characteristics of the SAR Images and Interferometric Phase over Oyster Sea Farming Site (굴 양식장에서의 SAR 영상 및 간섭위상 특성)

  • 김상완;이창욱;원중선
    • Korean Journal of Remote Sensing
    • /
    • v.18 no.4
    • /
    • pp.209-220
    • /
    • 2002
  • We carried out studies on SAR image intensity and interferometric phase over oyster sea farms. Strong backscattering was observed in amplitude images, and that was considered as a radar signal double bouncing from horizontal bars. These sea farming structures are not visible in satellite optical images except IKONOS image, so that it demonstrates the value of radar remote sensing as an effective tool in support of sea farm detection. The intensity of the image is sensitive to system parameters including wavelength, polarization, and look direction, but does not correlate to tide height. We found that the strongest backscattering can be obtained by L-band HH-polarization with a look direction perpendicular to the horizontal bar. We also succeeded in generating 21 coherent JERS-1 SAR interferometric pairs over the oyster farms. The general trend of the fringe rate of the interferometric phases appeared to be governed by altitude of ambiguity. The general trend was modeled by an inverse function and removed to have a residual phase. The residual phase showed a linear relation with the tide height. The results demonstrate for the first time that SAR can possibly be used to estimate sea level. However, the r.m.s. error of a regression line is 11.7 cm, and that is so far too large to make reliable assessments of sea level in practical applications. Further studies is required to improve the accuracy specifically using multi-polarization SAR data.

Intertidal DEM Generation Using Waterline Extracted from Remotely Sensed Data (원격탐사 자료로부터 해안선 추출에 의한 조간대 DEM 생성)

  • 류주형;조원진;원중선;이인태;전승수
    • Korean Journal of Remote Sensing
    • /
    • v.16 no.3
    • /
    • pp.221-233
    • /
    • 2000
  • An intertidal topography is continuously changed due to morphodynamics processes. Detection and measurement of topographic change for a tidal flat is important to make an integrated coastal area management plan as well as to carry out sedimentologic study. The objective of this study is to generate intertidal DEM using leveling data and waterlines extracted from optical and microwave remotely sensed data in a relatively short period. Waterline is defined as the border line between exposed tidal flat and water body. The contour of the terrain height in tidal flat is equivalent to the waterline. One can utilize satellite images to generate intertidal DEM over large areas. Extraction of the waterline in a SAR image is a difficult task to perform partly because of the presence of speckle and partly because of similarity between the signal returned from the sea surface and that from the exposed tidal flat surface or land. Waterlines in SAR intensity and coherence map can effectively be extracted with MSP-RoA edge detector. From multiple images obtained over a range of tide elevation, it is possible to build up a set of heighted waterline within intertidal zone, and then a gridded DEM can be interpolated. We have tested the proposed method over the Gomso Bay, and succeeded in generating intertidal DEM with relatively high accuracy.

A REVIEW ON THE ODSCC OF STEAM GENERATOR TUBES IN KOREAN NPPS

  • Chung, Hansub;Kim, Hong-Deok;Oh, Seungjin;Boo, Myung Hwan;Na, Kyung-Hwan;Yun, Eunsup;Kang, Yong-Seok;Kim, Wang-Bae;Lee, Jae Gon;Kim, Dong-Jin;Kim, Hong Pyo
    • Nuclear Engineering and Technology
    • /
    • v.45 no.4
    • /
    • pp.513-522
    • /
    • 2013
  • The ODSCC detected in the TSP position of Ulchin 3&4 SGs are typical ODSCC of Alloy 600MA tubes. The causative chemical environment is formed by concentration of impurities inside the occluded region formed by the tube surface, egg crate strips, and sludge deposit there. Most cracks are detected at or near the line contacts between the tube surface and the egg crate strips. The region of dense crack population, as defined as between $4^{th}$ and $9^{th}$ TSPs, and near the center of hot leg hemisphere plane, coincided well with the region of preferential sludge deposition as defined by thermal hydraulics calculation using SGAP computer code. The cracks developed homogeneously in a wide range of SGs, so that the number of cracks detected each outage increased very rapidly since the first detection in the $8^{th}$ refueling outage. The root cause assessment focused on investigation of the difference in microstructure and manufacturing residual stress in order to reveal the cause of different susceptibilities to ODSCC among identical six units. The manufacturing residual stress as measured by XRD on OD surface and by split tube method indicated that the high residual stress of Alloy 600MA tube played a critical role in developing ODSCC. The level of residual stress showed substantial variations among the six units depending on details of straightening and OD grinding processes. Youngwang 3&4 tubes are less susceptible to ODSCC than U3 and U4 tubes because semi-continuous coarse chromium carbides are formed along the grain boundary of Y3&4 tubes, while there are finer less continuous chromium carbides in U3 and U4. The different carbide morphology is caused by the difference in cooling rate after mill anneal. There is a possibility that high chromium content in the Y3&4 tubes, still within the allowable range of Alloy 600, has made some contribution to the improved resistance to ODSCC. It is anticipated that ODSCC in Y5&6 SGs will be retarded more considerably than U3 SGs since the manufacturing residual stress in Y5&6 tubes is substantially lower than in U3 tubes, while the microstructure is similar with each other.

Analysis of Binding Media in Dancheong Sample from Unhangak Hall of Hwaryeongjeon Shrine, Suwon (수원 화령전 운한각 단청시편의 교착제 분석)

  • Park, Jongseo;Lee, Sun Myung;Mun, Seong Woo;Kang, Yeong Seok
    • Journal of Conservation Science
    • /
    • v.37 no.3
    • /
    • pp.245-254
    • /
    • 2021
  • In this study, organic materials in Dancheong specimens were analyzed to establish a Dancheong preparation method in Unhangak Hall of Hwaryeongjeon Shrine, Suwon. IR and pyrolysis/GC/MS were applied to a Zuhong specimen and a gilded one. The IR spectra showed absorption peaks corresponding to C-O, C=O, OH, although they were different from those of animal glue, Asian lacquer, and drying oil. The Pyrolysis/GC/MS after the on-line methylation revealed Asian lacquer-derived components, such as methyl 7-(2,3-dimethoxyphenyl)heptanoate, and drying oil-derived components, such as nonanedioic acid, dimethyl ester. Based on these results, we estimated that Asian lacquer and drying oil were used in the Dancheong preparation. Small amounts of 3-methyl-1H-pyrrole were also detected, which could possibly originate from animal glue. The radiocarbon age of the specimens appeared to be between the late 17th to the early 20th century. This study potentially reports the first case of Asian lacquer detection in a Dancheong specimen in Korea.

The Recovery of the Deleted Certificate and the Detection of the Private-Key Encryption Password (삭제된 공인인증서의 복구 및 개인키 암호화 패스워드의 검출)

  • Choi, Youn-Sung;Lee, Young-Gyo;Lee, Yun-Ho;Park, Sang-Joon;Yang, Hyung-Kyu;Kim, Seung-Joo;Won, Dong-Ho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.17 no.1
    • /
    • pp.41-55
    • /
    • 2007
  • The certificate is used to confirm and prove the user's identity in online finance and stocks business. A user's public key is stored in the certificate(for e.g., SignCert.der) and the private key, corresponding to public key, is stored in the private key file(for e.g., SignPri.key) after encryption using the password that he/she created for security. In this paper, we show that the certificate, deleted by the commercial certificate software, can be recovered without limitation using the commercial forensic tools. In addition, we explain the problem that the private key encryption password can be detected using the SignCert.der and the SignPri.key in off-line and propose the countermeasure about the problem.

Performance Evaluation of Lead (II) Oxide Dosimeter for Digital Quality Assurance in Brachytherapy (방사선 근접치료의 디지털 정도관리를 위한 Lead (II) Oxide 선량계 성능 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.429-435
    • /
    • 2021
  • In intracavitary radiotherapy, incorrect location of the source can cause excessive dose to normal tissue, so it is essential to evaluate the location accuracy of the source. In this study, basic research was performed on digital line dosimeter based on lead (II) oxide (PbO) to improve analog verification method. Therefore, a polycrystalline PbO unit cell dosimeter was manufactured and the measurement performance for Ir-192 sources was evaluated. As a result, the reproducibility satisfies the evaluation criteria of 1.5% with a relative standard deviation of 0.85%. Linearity showed excellent results with a linear coefficient of R2 of 0.9998. In the case of distance dependence evaluation, the power function R2 showed 0.9855 for PbO and 0.9974 for diode, and the overall average difference was 1.66% for PbO and 2.18% for diode. This study presents the basic detection performance of the polycrystalline PbO dosimeter for the Ir-192 source and can provide basic data in the field of radiation measurement.