• Title/Summary/Keyword: line center

Search Result 4,313, Processing Time 0.061 seconds

Stability Evaluation of In-Line Measurement System with Repeated Measurements (반복 측정이 가능한 인라인 측정시스템의 안정성 평가)

  • Joung, Sooho;Byun, Jai-Hyun
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.30 no.1
    • /
    • pp.36-43
    • /
    • 2004
  • In-line measurement systems are preferred to those in analytical laboratories, since in-line systems provide rapid response to process upsets. If an in-line measurement system exhibits an unstable variation and if this instability in measurement variation goes undetected, it will make the process monitoring procedure invalid. This paper presents a stability evaluation procedure for the in-line measurement system using two independent readings from the in-line measurement system and one reading from the analytical laboratory, which requires less measurement cost and time.

analysis and computer-Aided Design of Microwave E-plane Filter and Unilateral fin-Line Filter by Variational Method (변분법에 의한 마이크로파 E-평면 여파기와 Unilateral Fin-Line 여파기의 해석 및 CAD 설계)

  • 임재붕;이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.6
    • /
    • pp.63-70
    • /
    • 1985
  • In this paper, the Unilateral Fin-line structure and the I-Plane structure are analysed by Rayleigh-Ritz variational method including the effect of conductor thickness. And a com-putcr-aided design program, CADUNI, is developed for microwave I-plane and Unilateral Fin-Line bandpass filters. Unilateral Fin-Line Filters are desigied at the center frequency of 10.5 GHz with guided bandwidth between 5% and 24.6%. Measured insertion loss is between 0.17 and 0.25 dB, and center frequency deviation is less than 0.2%. Experimental results are in good agree-ment with theory.

  • PDF

Study on Electrical Environmental Obstacle Using a 765kV Double Circuit Test Line (765kV 시험선로를 이용한 전기환경장해 특성연구)

  • Kim, Jeong-Boo;Jo, Seong-Sae;Shin, Goo-Yong;Lee, Dong-Il;Yang, Kwang-Ho;Ahn, Hee-Sung;Bae, Jeong-Hyo;Koo, Ja-Yoon;Min, Seok-Weon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1517-1519
    • /
    • 1994
  • This paper describes electrical environmental study of a 765kV double circuit test line. Corona performance on several candidate conductor bundles has been investigated in the corona cage (single phase simulation facility) since 1984. We have known that six RAIL conductor bundle is the most suitable for the 765kV transmission Line, [3] To investigate electrical environmental impact of the future commerciale line, we build a full sacle 765kV test line in 1993. The test results of Audible Noise, Radio Interference, TV Interference from August, 1993 to Jan. 1994 were measured as $48.7[dBA](L_{50})$. $57.4[dB{\mu}V/m]$(Fair weather, $L_{50})$. $14.5[dB${\mu}$V/m]$(Fair weather, $L_{50}$). We have found that the Audible Noise data were very close to the predicted(48.5 [dBA]) by BPA Corona and Field Effects Computer program, however, the RI and TVI data were much higher than predicted(42 [dBmV/m], $7.9[dB{\mu}V/m)$ by the BPA program. We have investigating the reason of the difference. In the constructing of full scale test line, we developed the tubular tower, 765kV test transformer and hardwares of 765kV transmission line insulator strings. Also we will investigate the effects of plants under the 765kV test Line.

  • PDF

A Miniaturized CMOS MMIC Bandpass Filter with Stable Center Frequency for 2GHz Application

  • Kang, In Ho;Guan, Xin
    • Journal of Navigation and Port Research
    • /
    • v.36 no.9
    • /
    • pp.737-740
    • /
    • 2012
  • A miniaturized CMOS bandpass filter for a single RF transceiver system is presented, using diagonally end-shorted coupled lines and lumped capacitors. In contrast to conventional miniaturized coupled line filters, it is proven that the effective permittivity variation of the coupled transmission line has no effect on shifting the center frequency when the bandpass filter is highly miniaturized. A bandpass filter at a center frequency of 2 GHz was fabricated by $0.18{\mu}m$ CMOS technology. The insertion loss with the die area of $1500{\mu}m{\times}1000{\mu}m$ is -5.14 dB. Simulated results are well agreed with the easurements. It also verify the center frequency stability in the compact size bandpass filter.

Negative Group Delay Circuit with Improved Signal Attenuation and Multiple Pole Characteristics

  • Chaudhary, Girdhari;Jeong, Junhyung;Kim, Phirun;Jeong, Yongchae
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.2
    • /
    • pp.76-81
    • /
    • 2015
  • This paper presents a design of a transmission line negative group delay (NGD) circuit with multiple pole characteristics. By inserting an additional transmission line into a conventional NGD circuit, the proposed circuit provides further design parameters to obtain wideband group delay (GD) and to help reduce signal attenuation. As a result, the number of gain compensating amplifiers can be reduced, which can contribute to stable operation when integrated into RF systems. The multiple pole characteristics can provide wider NGD bandwidth and can be obtained by connecting resonators with slightly different center frequencies separated by quarter-wavelength transmission lines. For experimental validation, an NGD circuit with two poles GD characteristic is designed, simulated, and measured.

Study on Extraction of the Center Point of Steam Generator Tubes (증기발생기 세관의 중심좌표추출에 대한 연구)

  • 조재완;김창회;서용칠;최영수;김승호
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.263-266
    • /
    • 2002
  • This paper describes extraction procedure for the center coordinates of steam generator tubes of Youngkwang NPP #6, which are arrayed in triangular patterns. Steam generator tube images taken with wide field-of-view lens and low-light lamp mounted on a ccd camera tend to have low contrast, because steam generator is sealed and poorly illuminated. The extraction procedures consists of two steps. The first step is to process the region with superior contrast in entire image of steam generator tubes and to extract the center points. Using the extracted coordinates in the first step and the geometrical array characteristics of tubes lined up in regular triangle forms, the central points of the rest region with low contrast are estimated. The straight lines from center point of a tube to neighbour points in horizontal and 60, 120$^{\circ}$ degree directions are derived. The intersections of straight line In horizontal direction and slant line in regular triangle direction are selected as the center coordinates of steam generator tubes. The Chi-square interpolation method is used to determine the line's coefficients in horizontal and regular triangle direction.

  • PDF

Design of Adaptive Inverse Control for Center Position Control of Steel-Strip in Continuous Annealing Line (연속소둔로에서 판중심 위치 제어를 위한 적응 역비례 제어기의 설계)

  • Kim, Young-Su;Jo, Sung-Eun;Lee, Young-Kow;Kim, Sang-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.608-610
    • /
    • 2004
  • In continuous annealing line (CAL), POSCO, the center position control (CPC) is an essential technique that renders the steel-strip to pass at the center of a roll in order to prevent the strip from skewing or breaking. The CPC algorithm currently installed on the steering roll in the heating section of CAL is to control the strip position by using the reverse phase of error from the center position, without considering the dynamics of strip horizontal movement. Such algorithm may, unfortunately, require a manual operation occasionally when the range of strip input becomes wide, causing the dynamics 0 be dominant. Other PID-type control is rarely used in automatic operation because the excess of response may occur when the discontinuous points such as welding joints pass through rolls. In this paper, we identify the CPC system by using off-line data and design a compensator for the excessive dynamics by using the adaptive inverse control. Simulation result depicts the improved reliability of the proposed CPC system.

  • PDF

Fabrication of Fluorine Doped Diamond-Like Carbon Stamp for UV-Nanoimprint Lithography (UV 나노임프린트 리소그래피를 위한 불화 함유 다이아몬드 상 탄소 스탬프의 제작)

  • Ozhan Altun Ali;Jeong Jun-Ho;Rha Jong-Joo;Choi Dae-Geun;Kim Ki-Don;Lee Eung-Sug
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.145-146
    • /
    • 2006
  • A fluorine-doped diamond-like carbon (F-DLC) stamp which has high contact angle, high UV-transmittance and sufficient hardness, was fabricated using the following direct etching method: F-DLC is deposited on a quartz substrate using DC and RF magnetron sputtering, PMMA is spin coated and patterned using e-beam lithography and finally, O2 plasma etching is performed to transfer the line patterns having 100 nm line width, 100 nm line space and 70 nm line depth on F-DLC. The optimum fluorine concentration was determined after performing several pre-experiments. The stamp was applied successfully to UV-NIL without being coated with an anti-adhesion layer.

  • PDF

Fabrication of metal line on plastic substrate by hot embossing and CMP process (핫 엠보싱 공정과 CMP 공정을 이용한 플라스틱 기판에 메탈 라인 형성)

  • Cha, Nam-Goo;Kang, Young-Jae;Park, Chang-Hwa;Rim, Hyung-Woo;Park, Jin-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.655-656
    • /
    • 2005
  • In the future, plastic based system will play a crucial role in modem life, for examples, transparent display or disposable electronics and so on. In this paper, we introduced a new method to fabricate the metal line on the plastic substrate. Metal lines were fabricated by hot embossing and CMP process on PMMA (polymethylmethacrylate) substrates. A Si mold was made by wet etching process and a PMMA wafer was cut off from I mm thick PMMA sheet. A 100 nm thick Al was deposited on PMMA wafers. The Al deposited PMMA wafer and the Si mold carefully sandwiched which was directly imprinted by hot embossing. After imprinting process, a residual Al layer was removed by CMP process. Finally, we found the entire process may be very useful to fabricate the metal line on plastic substrates.

  • PDF

A new line to line fault location algorithm in distribution power networks using 3 phase direct analysis (3상회로의 직접해석에 의한 배전계통 선간단락 사고 고장거리 계산 알고리즘)

  • Jin, B.G.;Choi, M.S.;Lee, S.J.;Yoon, N.S.;Jung, B.T.;Lee, D.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.108-110
    • /
    • 2002
  • In this paper, a fault location algorithm is suggested for line to line faults in distribution networks. Conventional fault location algorithms use the symmetrical component transformation, a very useful tool for transmission network analysis. However, its application is restricted to balanced network only. Distribution networks are, in general, operated in unbalanced manners, therefore, conventional methods cannot be applied directly, which is the reason why there are few research results on fault location in distribution networks. Especially, the line to line fault is considered as a more difficult subject. The proposed algorithm uses direct 3-phase circuit analysis, which means it can be applied not only to balanced networks but also to unbalanced networks like distribution a network. The comparisons of simulation results between one of conventional methods and the suggested method are presented to show its effectiveness and accuracy.

  • PDF