• Title/Summary/Keyword: line bundle

Search Result 81, Processing Time 0.026 seconds

Multi-focal Microscopic System Using a Fiber Bundle (광섬유 다발을 이용한 다초점 현미경)

  • Gu, Young-Mo;Ham, Hyo-Shick;Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.354-360
    • /
    • 2009
  • We have constructed and analyzed the performance of a simple fiber bundle multi-focal microscope. The microscope had a fiber bundle substituted for micro-lens array that is the core part of MMM(multi-focal multi-photon microscope). The MMM is a type of confocal microscope. To analyze the performance and characteristics of the fiber bundle multi-focal microscope, three types of samples were used: a standard grating, USAF 1951(7, 3), and 1951(7, 6). Using two polarizers and a polarizing beam splitter, we eliminated noise and got clear images. We obtained the FWHM of fiber spot images with the standard grating using two different magnifier lenses which were 63X and 20X, and found an image of the sample as a distribution of fiber spot images. For this case we used the low magnification lens, which gives denser distribution, so that we could get clearer images. In order to test the resolution of the fiber bundle multi-focal microscopic system, we used the USAF 1951 sample which has a smaller line interval than that of the standard grating. The FWHM of the line width of the image coincides well with the real line width of the USAF 1951 sample. We confirmed the performance of a fiber bundle multi-focal microscopic system which is relatively simple but has submicron resolution and is able to get 1600 images at the same time.

The Effects of Bundle Price Discount Framing and Message Framing on Consumers' Evaluation of Bundle Component (번들가격할인 프레이밍과 메시지 프레이밍이 소비자의 번들구성제품에 대한 평가에 미치는 영향)

  • Park, Sojin
    • Asia Marketing Journal
    • /
    • v.13 no.3
    • /
    • pp.55-77
    • /
    • 2011
  • This study investigate the interaction effects of bundle price discount framing and message framing on consumer's attitude of bundle component. Although each effect of bundle price discount framing and message framing has been explored individually, few attempts have been made to invest them jointly. This study tests the interaction effects of bundle price discount framing and message framing on consumer's evaluation of bundle component. Moreover, this research focuses on consumer's evaluation of individual bundle component while the existing research on bundling primarily focused on consumer's evaluation of the bundle. Prior research suggests that consumers are sensitive to the framing of prices and discounts in the presentation of the bundle offer. For example, there is considerable evidence that partitioning or consolidating the prices of a bundle can influence the attractiveness of the bundle offer. Similarly, there is evidence that an equivalent price reduction to the overall bundle, one of the individual products in the bundle, or distributed among the individual products in the bundle can alter the perceived attractiveness of the offer (e.g. Chakravarti, Krish, Paul, and Srivastava 2002; Hamilton and Srivastava 2008; Janiszewski and Cunha 2004; Johnson, Herrmann and Bauer 1999; ; Morwitz, Greenleaf, and Johnson 1998; Yadav 1994; 1995). In line with these earlier research, this research suggests that the bundle type can influence the consumer's evaluation of bundle component. There are two types of bundle - mixed-leader bundle and mixed-joint bundle. In mixed-leader bundling, the price of one of the two products is discounted when the other product is purchased at the regular price. In mixed-joint bundling, a single price is set when the two product are purchased jointly. This study supposes that the teeth whitening product is the leader product in a mixed-leader bundle. So bundle price discount framing is manipulated such as "Buy the teeth whitening product (regular price \80,000) and get 50% discount on the functional toothpaste(regular price \40,000), special set price \100,000" or "Buy the functional toothpaste and the teeth whitening product as a set and get discount for the set, special set price \60,000". Message framing is manipulated through the product claims described in an advertising bill. The positive framing presents that "Over 95% of users achieved the expected 2-3 shades of improvement in two weeks" where as the negative framing presents "less than 5% of users did not achieve the expected 2-3 shades of improvement in two weeks". This study uses hypothetical brand name of the teeth whitening product and the functional toothpaste This study is based on a 2x2 factorial design with bundle discount framing (mixed-leader bundle vs. mixed-joint bundle) and massage framing (positive vs. negative). The dependant variables are consumer's perceived quality and attitude of the teeth whitening product The data reveals that two dependant variables are correlated, so the data is analyzed with two-way MANOVA. This research explores the significant interaction effect of bundle discount framing and message framing on consumer's perceived quality and attitude of the teeth whitening product. When the message framing is positive, consumer's perceived quality and attitude of the teeth whitening product is higher in mixed-leader bundle than mixed-joint bundle condition. However, when the message framing is negative, consumer's evaluation is higher in mixed-joint bundle than mixed-leader bundle. The author explains this result by stating that consumers are less likely to use heuristics such as price-quality association and value discounting hypothesis(Raghubir 2004) in the negative message framing condition. Additionally, consumer's perceived risk of the teeth whitening product in the negative message framing condition can be more reduced by the bundle partner(e.g. the toothpaste) in mixed-joint bundle than mixed-leader bundle. Based on the results, marketing managers are advised to use different bundle type based on message framing of their product.

  • PDF

A Study on the Loss Probability and Dimensioning of Multi-Stage Fiber Delay Line Buffer (다단 광 지연 버퍼의 손실률과 크기에 관한 연구)

  • 김홍경;이성창
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.10
    • /
    • pp.95-102
    • /
    • 2003
  • The buffering is a promising solution to resolve the contention problem in optical network. we study the packet loss probability and the dimensioning of optical buffer using a Fiber Delay Line for variable length packet. In this paper, we study the relation between the granularity and the loss of FDL buffer in Single-Stage FDL buffer and propose the Single-Bundle Multi-Stage FDL buffer. The Multi-Stage FDL buffer is too early yet to apply to the current backbone network, considering the current technology in view of costs. but we assume that the above restriction will be resolved in these days. The appropriate number of delay and pass line for a dimensioning is based on a amount of occupied time by packets. Once more another multi-stage FDL buffer is proposed, Split-Bundle multi-stage FDL buffer. The Split-Bundle ms-FDL buffer is more feasible for a FDL buffer structure, considering not only a size of switching matrix but also a bulk of switching element. its feasibility will be demonstrated from a loss probability.

Assessment of the Electrical Environmental Characteristics to Decide Optimal Bundle Type for HVDC ${\pm}500kV$ Overhead Transmission Lines (HVDC ${\pm}500kV$ 가공 송전선로의 최적 도체방식 선정을 위한 전기환경특성 평가)

  • Ju, Mun-No;Kil, Gyung-Suk;Yang, Kwang-Ho;Lee, Sung-Doo;Hwang, Gi-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.520-526
    • /
    • 2006
  • Corona interferences, such as radio noise, audible noise and television noise, need to be taken into account in the design of HVDC transmission line conductor configuration. Therefore the line designer requires data from which to estimate the corona performance of any set of conductors. To get a sufficiently complete set of design data, it is necessary to examine the corona test of a large number of conductor geometries. This paper presents the results of corona cage test among three types of candidate conductors. It is quite clear from test results that the conductor geometries play an important role in establishing the magnitude of corona noise. Corona noise data from corona cage test are expressed as a statistical distribution of results obtained over long periods of time and various weather conditions. Therefore we can determine an environmentally-friendly conductor bundle for HVDC overhead transmission line. Based on this finding results, various simulations about HVDC line configurations, such as pole space and pole height, will be conducted. And then finally an optimal configuration for HVDC transmission line will be decided.

Environmental Impact on the KEPCO 765-kV Double Circuit Transmission Line (한전 765 kV 2회선 송전선로의 전기환경장애 특성)

  • Lee, D.I;Sin, K.Y;Kim, J.B
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • The environmental impact of the KEPCO 765-kV transmission line was studied using a full scale test line in order to develop the design technology. Therefore this paper describes an environmental design summary of the audible noise, hum noise, wind noise, radio interference, TV interference and electric field measurement from the KEPRI 765-kV double circuit transmission test line with a bundle of $6-480mm^2$ conductors per phase. The analysis of the test results shows that 6-Rail and 6-Cardinal conductors bundle satisfy the audible noise criterion & TV interference under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion for KEPCO 765-kV transmission line.

  • PDF

Predicting formula development of audible noise on a 765kV AC transmission line(I) (765kV 교류 송전선로의 가청소음계산 예측식개발(I))

  • 이동일;구자윤
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.4
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

SOLUTION TO ${\bar{\partial}}$-PROBLEM WITH SUPPORT CONDITIONS IN WEAKLY q-CONVEX DOMAINS

  • Saber, Sayed
    • Communications of the Korean Mathematical Society
    • /
    • v.33 no.2
    • /
    • pp.409-421
    • /
    • 2018
  • Let X be a complex manifold of dimension n $n{\geqslant}2$ and let ${\Omega}{\Subset}X$ be a weakly q-convex domain with smooth boundary. Assume that E is a holomorphic line bundle over X and $E^{{\otimes}m}$ is the m-times tensor product of E for positive integer m. If there exists a strongly plurisubharmonic function on a neighborhood of $b{\Omega}$, then we solve the ${\bar{\partial}}$-problem with support condition in ${\Omega}$ for forms of type (r, s), $s{\geqslant}q$ with values in $E^{{\otimes}m}$. Moreover, the solvability of the ${\bar{\partial}}_b$-problem on boundaries of weakly q-convex domains with smooth boundary in $K{\ddot{a}}hler$ manifolds are given. Furthermore, we shall establish an extension theorem for the ${\bar{\partial}}_b$-closed forms.

Electrical and Mechanical Noise Study of the 765kV Transmission Line (765kV 송전선로의 전기적 및 기계적 소음고찰)

  • Lee,
    • Journal of KSNVE
    • /
    • v.6 no.1
    • /
    • pp.89-95
    • /
    • 1996
  • If the transmission line voltage is greater than 500kV, audible noise (AN) and hum noise (HN) due to corona discharges on the conductor would be an important design factor for the conductor selection of transmission line. Also there is an aeolian noise: wind noise(WN) from the tower and the conductor due to wind. This paper presents the results of a statistical analysis of audible noise, hum noise, aeolian noise of 6-480mm$^{2}$ conductor bundle in KEPRI 765kV Test Transmission Line which was constructed to develop 765kV double circuit AC transmission line for the first time in the world. The result of the analysis shows that 6-480mm$^{2}$ conductor bundle and tower satisfy configuration the audible noise design criterion of 50dB(A).