• 제목/요약/키워드: limiting device

검색결과 155건 처리시간 0.025초

직렬 연결된 두 코일과 YBCO Coated Conductor로 구성된 초전도 전류제한기의 권선방향과 권선 비에 따른 전류제한 특성 분석 (Analysis on Current Limiting Characteristics of the SFCL with Magnetically Coupled Two Coils and YBCO Coated Conductor Due to the Winding Direction and the Turn Number' Ratio Between Two Coils)

  • 이동혁;두호익;김용진;한병성;한상철;이정필
    • 한국전기전자재료학회논문지
    • /
    • 제24권1호
    • /
    • pp.52-56
    • /
    • 2011
  • The ongoing Superconducting Fault Current Limiter(SFCL) development mainly has focused on the application of commercializaton and power system through combining with normal-conducting device, moving away from current-limiting method, which is solely dependant on the existing superconductor. Compared to the structural development above, on the other hand, the research on applying superconducting current-limiting element to SFCL, the heart of SFCL, still has a lot left to do, apart form traditional resistive type SFCL. In this study, we looked into the current limiting characteristic of SFCL using core and coil. YBCO coated conductor with stainless steel stabilizer layer was verified by the excellent of current-limiting element of the resistive type SFCL that has a high Jc and index as well as being superior in mechanical property. Also, we study temperature characteristics and resistance characteristics, max voltage, response time and current-limiting ability that can be an indicator as current-limiting element while applying to superconducting current-limiting element caused by variation of winding direction, winding ratio of SFCL using core and coil.

정보통신기기용 과도이상전압 고속도차단장치의 설계 및 제작 (Design and Fabrication of a High Speed Blocking Device of Transient Overvoltages for info-communication Facilities)

  • 길경석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제48권1호
    • /
    • pp.51-56
    • /
    • 1999
  • This paper presents a new transient overvoltage blocking device (TOBD) for info-communication facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, thehybrid type TOBD, which consists of a gas tube, avalanche diodes and junction typefield effect transistors (JFETs), was designed and fabricated. The TOBD differs from the conventional protection devices in configuration, and JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche dilde with low energy capacity are protected fromthe high current, and the TOBD has a very small input capacitance. From the performance test using combination surge generator, which can produce $1.2/50\mus\;4.2kV_{max}\; 8/20\mus\; 2.1kA_{max}$, it is confirmed that proposed TOBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF

진단용 X선발생장치의 X선관 가변조리개 성능검사와 조사야일치검사 및 중심선속 일치검사에 대한 평가 (Evaluation to X-ray Tube Variable Beam Limiting Device Ability Test, Collimation and Beam Alignment Test of Diagnostic X-ray Unit)

  • 임인철;이상훈
    • 한국콘텐츠학회논문지
    • /
    • 제9권3호
    • /
    • pp.250-255
    • /
    • 2009
  • 본 연구는 경남 김해지역내의 병원에서 사용되고 있는 진단용방사선발생장치 중 일반촬영용장비 40대를 X선관 가변조리개 성능검사와 광조사야와 실제 X선조사야면의 일치검사 및 초점과 가변조리개의 중심선속 일치검사를 통해 장비의 성능을 평가 조사하여 다음과 같은 결과를 얻을 수 있었다. 1. 가변조리개 성능검사에서 최대X선조사야시험 결과는 부적절한 장비가 4대(10%), 최소X선조사야시 험결과에서는 5대(12.5%)로 나타났다. 2. 광조사야와 X선조사야일치시험 결과에서는 최대허용치인 2%이내가 23대(57.5%), 2%이내를 벗어난 장비가 17대(42.5%)로 나타났다. 3. 중심선속 일치시험 결과에서는 완전일치가 11대(27.5%), $0.5^{\circ}$이내로 벗어난 경우는 11대(27.5%), $0.6^{\circ}-1.5^{\circ}$이내가 10대(25%), $1.6^{\circ}-3^{\circ}$이내가 7대(17.5%), $3^{\circ}$이상인 경우가 1대(2.5%)로 나타났다. 결론적으로 가변조리개 중 일부가 기준치에 떨어진 성능상태에서 사용하고 있었으며, 광조사야와 X선 조사야일치상태 및 중심선속 일치에서도 최대허용치를 벗어난 상태에서 상당수의 장비를 사용하고 있었다. 그러므로 피검자의 방사선 피폭을 최소화하고 영상의 질을 향상시키기 위해서는 주기적이고 지속적인 점검평가를 거쳐 노후화 되었거나 부족한 성능상태의 기기를 수리, 보완해야함을 알 수 있었다.

한류형 반도체 교류 차단기 개발에 관한 연구 (A Study on Development of Current Limiting solid-state AC circuit Breaker)

  • 이우영;김용주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.73-77
    • /
    • 1990
  • In this paper we describe the solid-state ac-circuit breaker which has the characteristic of both a half cycle circuit breaker and a current limiting circuit breaker. This circuit breaker has a current limiting resistor in order to surprises the fault current to a certain level and discharge the energe included in circuit inductor. We explain the effect of circuit parameter on transient phenomena of switch device by using EMTP and finally design the control circuit consisted synchronous closing circuit, over- current detecting circuit and sensing circuit of rate of rise of fault current.

  • PDF

Field Limiting Ring 구조의 해석적 모델 (An Analytic Model of Field Limiting Ring Structure)

  • 라경만;정상구;최연익;김상배
    • 전자공학회논문지A
    • /
    • 제31A권7호
    • /
    • pp.95-101
    • /
    • 1994
  • A novel concept for the analysis of planar devices with a field limiting ring(FLR) is presented which allows analytic expressions in a normalized form for the potential distributions of FLR structure. Based on the method of image charges the main and ring junctions with identical cylindrical edges are kept to be two different equipotential surfaces. The potential relations between main and ring junction of the FLR structure are compared with 2-dimensional device simulation program. MEDICI. A good accordance is found. Comparisions with experimental data reported for the optimum ring spacing and the relative improvement of the breakdowm voltages in the FLR sturcture show the validity of the concept. The normalized expressions allow a universal application regardless to the junction depths and background doping levels.

  • PDF

자기장인가에 따른 YBCO 박막형 한류기의 동시?치 연구 (Studies of Simultaneous Quench of Superconducting YBCO Flims for Fault Current Limiter Under the Influence of Magnetic Fields)

  • 박권배;이방욱;강종성;오일성;최효상;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.84-88
    • /
    • 2002
  • The resistive fault current limiter (SFCL) is a very attractive device for power networks. But it has a serious Problem in using YBCO films for fault current limiter is inhomogeneities caused by imperpect manufacturing. So simultaneous quenches are a difficult problem which elements for current limiting are connected in series for increasing voltage ratings. We investigated extended electric field-current characteristics for current limiting element of YBCO film when O-130mT magnetic field is applied. And quench characteristics were investigated in over all element and between elements of YBCO films. From the experiments, it was shown that applied magnetic fields using solenoid coil induced uniform quench distribution for over all stripes and simultaneous quench in all elements for current limiting of YBCO film was realized. We have achieved resistive fault current limiter of 1.2kV/20A rating using magnetic field.

기계적 접점을 이용한 FCL의 동작 특성 (Operational Characteristics of the FCL Using the Mechanical Contact in the Power System)

  • 정병익;최효상
    • 전기학회논문지
    • /
    • 제65권5호
    • /
    • pp.878-882
    • /
    • 2016
  • These days, SFCLs are being developed in order to limit fault current. However, the superconducting elements that limit the fault current have such problems as capacity increase and require auxiliary devices including cooling device. If devices that comprise the current power network can withstand fault current for at least one cycle, it is possible to limit the fault current with current limiting elements by bypassing it on the fault line. In this study, the fault current limiter was configured with current transformer, vacuum interrupter, and current limiting element. Through the experience, it was confirmed that the fault current was limited within one cycle. The superconducting element, as a current limiting element, limited the fault current by 80 % within one cycle from fault occurrence, and the passive element limited it more than 95 %. Also, through the comparison between resistance curve and power consumption curve, it was confirmed that the current limiting element using a passive element was more stable than the superconducting element that required capacity increase and other auxiliary devices. It was considered that the FCL proposed in this study could limit fault current stably within one cycle from fault occurrence by using the existing power technologies such as fault current detection and solenoid valve operating circuit.

배전급 전류제한 장치 효과 분석 및 도입 방안 (Effects of distribution fault current limiting apparatus and emerging applications)

  • 이방욱;박권배;김호민;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1540-1541
    • /
    • 2006
  • For limitation and interruption of short circuit currents from low voltage to extra high voltage applications, the electrical equipment including fuses and circuit breakers, are widely used today. But in order to anticipate increasing needs for effective and competitive device for limiting the growing fault current in electrical power systems, fault current limitation technologies and fault current limitation devices are widely introduced and investigated in these days. Fault current limiters are emerging electric equipment which is under development using various methods including superconducting fault current limiter, solid state fault current limiter, arc driving fault current limiters. And these various methods have some advantages and disadvantages to take into considerations In order to commercialize fault current limiters in the electrical networks, a lot of discussions should be given on the point that fault current limiting methods, need for fault current limiters, coordination with existing protective system, and field experience before commercialization. In this paper, recent trends of fault current limiting technologies will be reviewed and the key issues of superconducting fault current limiters will be dealt with. And finally, future applications of superconducting fault current limiters would be discussed.

  • PDF

The Characteristics on the Change of Cerebral Cortex using Alternating Current Power Application for Transcranial Magnetic Stimulation

  • Kim, Whi-Young
    • Journal of Magnetics
    • /
    • 제19권2호
    • /
    • pp.197-204
    • /
    • 2014
  • A transcranial magnetic stimulation device is a complicated appliance that employs a switching power device designed for discharging and charging a capacitor to more than 1 kV. For a simple transcranial magnetic stimulation device, this study used commercial power and controlled the firing angle using a Triac power device. AC 220V 60 Hz, the power device was used directly on the tanscranial magnetic stimulation device. The power supply device does not require a current limiting resistance in the rectifying device, energy storage capacitor or discharge circuit. To control the output power of the tanscranial magnetic stimulation device, the pulse repetition rate was regulated at 60 Hz. The change trigger of the Triac gate could be varied from $45^{\circ}$ to $135^{\circ}$. The AVR 182 (Zero Cross Detector) Chip and AVR one chip microprocessor could control the gate signal of the Triac precisely. The stimulation frequency of 50 Hz could be implemented when the initial charging voltage Vi was 1,000 V. The amplitude, pulse duration, frequency stimulation, train duration and power consumption was 0.1-2.2T, $250{\sim}300{\mu}s$, 0.1-60 Hz, 1-100 Sec and < 1 kW, respectively. Based on the results of this study, TMS can be an effective method of treating dysfunction and improving function of brain cells in brain damage caused by ischemia.

고무코어패드와 강재이력감쇠장치를 결합한 복합감쇠장치의 이력특성에 관한 연구 (A Study on Characteristics of Hybrid Damping Device Combining Rubber Core Pad and Hysteretic Steel Slit)

  • 박병태;이준호
    • 한국공간구조학회논문집
    • /
    • 제23권1호
    • /
    • pp.45-52
    • /
    • 2023
  • This study proposes an RCS composite damping device that can achieve seismic reinforcement of existing buildings by dissipating energy by inelastic deformation. A series of experiments assessing the performances of the rubber core pad, hysteretic steel slit damping device, and hybrid RCS damping device were conducted. The results showed that the ratios of the deviations to the mean values satisfied the domestic damping-device conformity condition for the load at maximum device displacement in each direction, at the maximum force and minimum force at zero displacement, as well as the hysteresis curve area. In addition, three analysis models based on load-displacement characteristics were proposed for application to seismic reinforcement design. In addition, the validity of the three proposed models was confirmed, as they simulated the experimental results well. Meanwhile, as the shear deformation of the rubber-core pad increased, the hysteretic behavior of super-elasticity greatly increased the horizontal force of the damping device. Therefore, limiting the allowable displacement during design is deemed to be necessary.