• Title/Summary/Keyword: limited measurements

Search Result 542, Processing Time 0.032 seconds

A Technical Trend on Natural Rubber Electrical Conduction Mechanism (천연고무의 전기전도기구에 관한 기술 동향)

  • Baek, Jae-Wook;Son, Sang-Cheol;Kim, Young-Keun;Oh, Jae-Han;Kim, Hyung-Gon;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1970-1971
    • /
    • 2007
  • The efficiency of such work highly depend on the worker's safety, who is protected by tools such as gloves, sleeves, blankets and flexible coverings among other manufactured natural-rubber goods. Use, storage and maintenance of these tools guarantee the quality and durability of the material. However, it might be observed that good tools made of such material are disapproved of when received from manufacturers or when they are removed from the warehouse for replacement. This work shows the experimental results obtained from ageing at a temperature of $100^{\circ}C$ for 48, 70 and 312 h, although the application of AC electrical tension in samples and the measuring of current leakage are presented. The measurements in samples were carried out with samples prepared from the deformulated commercial materials and respectively reformulated into thin films. The obtained results showed the mechanisms of conduction of samples in low and high electric fields. It was also identified an electric tension transition showing that in low fields it prevails the Ohm's law conduction, and in high electric fields it prevails the conduction of space charge limited current (SCLC). These results can support the natural rubber formulation process having as their main objective the reducing of the mechanisms that occur under high conduction current in high electric fields, which leads the material to a dielectric breakdown. It is necessary to research this raw material from different internationally standard clones to characterize dielectric and electric properties for industrial applications. Moreover, this natural material has a low commercial price when compared to the synthetic ones.

  • PDF

Study on the Hybrid Passivation layer of OLEDs using the Organic/Inorganic Thin Film (유/무기 복합 박막을 이용한 유기발광 소자의 보호층에 관한 연구)

  • Bae, Sung-Jin;Lee, Joo-Won;Lee, Young-Hoon;Kang, Nam-Soo;Kim, Dong-Young;Hwang, Sung-Woo;Kim, Jai-Kyung;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.04a
    • /
    • pp.78-80
    • /
    • 2006
  • The hybrid thin-film (HTF) passivation layer composed of the Ultra Violet (UV) curable acrylate layer and MS-31 (MgO:$SiO_2$=3:1wt%) layer was adopted in organic light emitting device (OLEO) to protect organic light emitting materials from penetrations of oxygen and water vapors. The results showed that the HTF layer possessed a very low WVTR value of lower than $0.007gm/m^{2+}day$ at $37.8^{\circ}C$ and 100% RH. This value was within the limited range of the sensitivity of WVTR measurements. And the lifetime of the HTF passivated device became almost three times longer than that of the bare device. The HTF on the OLEO was found to be very effective in protect what from the penetrations of oxygen and moisture.

  • PDF

The design of a scintillation system based on SiPMs integrated with gain correction functionality

  • Lin, Zhenhua;Hautefeuille, Benoit;Jung, Sung-Hee;Moon, Jinho;Park, Jang-Guen
    • Nuclear Engineering and Technology
    • /
    • v.52 no.1
    • /
    • pp.164-169
    • /
    • 2020
  • Use of SiPM has been considered as an alternative to PMT, because of its compact size, low-operating voltage, non-sensitive to electromagnetic, low costs and so on. The main limitation for the use of SiPM is due to its small sensitive area compared to PMT that limits the light collection, and therefore the sensor energy resolution. In this article we studied the effect of increasing the number of SiPM by connecting them in parallel to increase the active detection area. This allowed us to compare the different energy resolution measurements. 137Cs has been selected as reference to study the energy resolution for 662 keV gamma-rays. Another investigation was to compare the minimum detectable gamma energy under various SiPM configurations. It has been found that the use of 4 SiPM arrays can greatly improve the energy resolution up to 4% than only one SiPM array, meanwhile use of more than 2 SiPM arrays does not increase the energy resolution significantly. Thus we can conclude that for a large area of cylindrical scintillator (3 × 3 inches), the use of SiPMs are limited to a certain number or certai active area depending on the commercial SiPMs, and its cost should be less than traditional PMT for the cost-effective and compact size considerations. It is well known that the gain of SiPM varies with temperature. In this article, we also calibrated gain to guarantee the same position of photoelectric peak in response of different temperatures.

Clinical application of cryolipolysis in Asian patients for subcutaneous fat reduction and body contouring

  • Oh, Chang Hyun;Shim, Jeong Su;Bae, Kwang Il;Chang, Jae Hoon
    • Archives of Plastic Surgery
    • /
    • v.47 no.1
    • /
    • pp.62-69
    • /
    • 2020
  • Background Cryolipolysis, a preferred method for minimally invasive body contouring, involves the noninvasive cooling of adipocytes to induce lipolysis without damaging other tissues. This study aimed to evaluate the safety and efficacy of cryolipolysis for the treatment of excessive fat tissue. Methods Between May 2014 and December 2017, 231 patients with 448 areas of interest were enrolled and their records were retrospectively reviewed. We used five different vacuum applicators, and the best-fitting applicator was used for each area. One cycle of cryolipolysis was applied at a cooling intensity factor of 41.6. The efficacy was evaluated 12 weeks after treatment via review of clinical photographs, the pinch test, and ultrasonographic measurements of fat thickness. The occurrence of any complications was also assessed. Results The volume was reduced in all of the areas to which cryolipolysis was applied. The rate of reduction of the fat layer as measured via the pinch test was 19.2%, and the rate of the decrease in fat layer thickness as measured via ultrasonography was 22.8%. Fat reduction of the upper arm differed significantly from that of the abdomen and flank, but no significant difference was found between sexes. The side effects were limited to erythema, edema, bruising, and numbness at the treatment site and resolved without treatment. Conclusions Cryolipolysis, with new and better-fitting applicators, is safe, fast, and effective for the reduction of excessive fat tissue on the abdomen, back, flank, and extremities. It is a good option for treating excess adipose tissue in Asian patients.

Effect of Pilates Gymball Exercises on the Electroencephalogram and Cognitive Function in Mentally Disabled Persons

  • Son, Yu-Joung;Lim, Jae-Heon
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.5
    • /
    • pp.227-233
    • /
    • 2017
  • Purpose: The aim of this study was to determine if Pilates gymball exercise can change the electroencephalogram and cognitive function of mentally disabled people. Methods: Twenty-one mentally disabled people were enrolled in this study. They were assigned randomly to one of two groups: Pilates gymball exercise group (PGEG, n=11), and control group (CG, n=10). The subjects in the PGEG group performed the exercises for 50 minutes a day, three days per week for 6 weeks. The PGEG program consisted of warm up (10 minutes), main workout (30 minutes), and cool down (10 minutes). The main workout consisted of 10 exercise programs. The electroencephalogram (EEG) of Fp1, Fp2, F3, F4, C3, C4, O1, and O2 were measured using an PolyG-I system. The cognitive function was evaluated using a mini-mental state examination (MMSE). The measurements were performed before exercise, and 6 weeks after exercise. Covariance analysis (ANCOVA) was performed to determine the difference between the two groups Results: A significant difference in Fp1, Fp2, and F3 on the relative alpha power was observed between the PGEG and CG groups (p<0.05). A significant difference in Fp1 on the relative beta power was observed between the PGEG and CG groups (p<0.05). No significant difference in the MMSE score was observed between the PGEG and CG groups. Conclusion: Pilates gymball exercise did positively change the EEG in the frontal lobe. On the other hand, the effect related to cognitive was limited. Pilates gymball exercise appears to be more effective in facilitating brain stimulation related to cognition.

Estimation of Link Travel Speed Using Single Loop Detector Measurements for Signalized Arterials (단일루프검지기를 이용한 간선도로 실시간 통행속도 추정 방법론)

  • 김영찬;최기주;김도경;오기도
    • Journal of Korean Society of Transportation
    • /
    • v.15 no.4
    • /
    • pp.53-71
    • /
    • 1997
  • This paper presents a methodology for estimating average travel speed using volume and occupancy data from single magnetic loop detectors for signalized arterials. Three methods were developed and evaluated using field data: VPLUSKO method, fuzzy control method, and neural network method. While the VPLUSKO method is easy to apply, it results poor performances compared to other methods. The neural network method showed the best performances among the candidate methods. This method revealed the weakness in transferability, however. From limited cases of field test, it was concluded that the method of the fuzzy control application showed reasonable performance of estimation. It was also demonstrated that the fuzzy control method has the capability of transferability.

  • PDF

Vortex pairing in an axisymmetric jet using fundamental and subharmonic forcing (기본교란 및 분수조화교란을 이용한 원형제트에서의 보텍스병합)

  • Jo, Seong-Gwon;Yu, Jeong-Yeol;Choe, Hae-Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1350-1362
    • /
    • 1997
  • An experimental study has been performed on vortex pairing under fundamental and subharmonic forcing with controlled initial phase differences through hot-wire measurements and a multi-smoke wire flow visualization. For the range of St$_{D}$ < 0.6, vortex pairing was controlled by means of fundamental and subharmonic forcing with varying initial phase differences. Much larger mixing rate was achieved by two-frequency forcing with a proper phase difference than one frequency forcing. As St$_{D}$ decreased, vortex pairing was limited to a narrow region of the initial phase difference between two disturbances and higher amplitudes of the fundamental and its subharmonic at the nozzle exit were required for more stable pairing. As the amplitude of the subharmonic at the nozzle exit increased for fixed St$_{D}$ and fundamental amplitude, the distribution of the subharmonic mode against the variation of the initial phase difference changed from a sine function form into a cusp-like form. Thus, vortex pairing can be controlled more precisely for the former case. For St$_{D}$ > 0.6, non-pairing advection of vortices due to the improper phase difference was sometimes observed in several fundamental forcing amplitudes when only the fundamental was applied. However, when its subharmonic was added, vortex pairing readily occurred. As the initial amplitude of this subharmonic increased, the position of vortex pairing moved upstream. This was thought to be due to the fact that the variation of the initial phase difference between the fundamental and its subharmonic has less effects on vortex pairing in the region of fundamental-only vortex pairing.pairing.

Patterns of Nerve Conduction Abnormalities in Patients with Type 2 Diabetes Mellitus According to the Clinical Phenotype Determined by the Current Perception Threshold

  • Park, Joong Hyun;Won, Jong Chul
    • Diabetes and Metabolism Journal
    • /
    • v.42 no.6
    • /
    • pp.519-528
    • /
    • 2018
  • Background: Clinical manifestations of diabetic peripheral neuropathy (DPN) vary along the course of nerve damage. Nerve conduction studies (NCS) have been suggested as a way to confirm diagnoses of DPN, but the results have limited utility for evaluating clinical phenotypes. The current perception threshold (CPT) is a complementary method for diagnosing DPN and assessing DPN symptoms. We compared NCS variables according to clinical phenotypes determined by CPT measurements. Methods: We retrospectively enrolled patients with type 2 diabetes mellitus who underwent both NCS and CPT tests using a neurometer. CPT grades were used to determine the clinical phenotypes of DPN: normoesthesia (0 to 1.66), hyperesthesia (1.67 to 6.62), and hypoesthesia/anesthesia (6.63 to 12.0). The Michigan Neuropathy Screening Instrument (MNSI) was used to determine a subjective symptom score. DPN was diagnosed based on both patient symptoms (MNSI score ${\geq}3$) and abnormal NCS results. Results: A total of 202 patients (117 men and 85 women) were included in the final analysis. The average age was 62.6 years, and 71 patients (35.1%) were diagnosed with DPN. The CPT variables correlated with MNSI scores and NCS variables in patients with diabetes. Linear regression analyses indicated that hypoesthesia was associated with significantly lower summed velocities and sural amplitudes and velocities, and higher summed latencies, than normoesthesia. Sural amplitude was significantly lower in patients with hyperesthesia than in patients with normoesthesia. Conclusion: NCS variables differed among patients with diabetes according to clinical phenotypes based on CPT and decreased sural nerve velocities was associated with hyperesthesia.

Effect of Dentin Desensitizer on the Hypersensitivity of Teeth with Non-carious Cervical Lesions Subsequent to Ultrasonic Scaling (지각과민처치제가 초음파 스케일링 처리한 비우식성 치경부 병소가 있는 치아의 지각과민증에 주는 영향)

  • Cho, Jae-Hyung;Seok, Soohwang;Lee, Sang-Hyeok;Lim, Bum-Soon
    • Korean Journal of Dental Materials
    • /
    • v.43 no.1
    • /
    • pp.17-28
    • /
    • 2016
  • The aim of this study was to evaluate the changes in dentinal permeability after application of dentin desensitizer on exposed dentin immediately after ultrasonic scaling to teeth with non-carious cervical lesions. Thirty caries-free extracted molars were fixed to slide glasses after horizontally being sectioned at 5 mm below the cemento- enamel junction (CEJ). The prepared specimen was connected to a fluid flow measuring device (nano-Flow), and a V-shaped cavity was formed at the CEJ to imitate the non-carious cervical lesion. After no fluid leakage was confirmed in the connected system with specimen, tooth surface was treated ultrasonic cleaning with piezoelectric ultrasonic scalers until dentinal tubules were exposed. And 6 different desensitizers were applied on exposed dentin. Real-time measurements of dentinal fluid flow were performed during ultrasonic scaling and application of dentin desensitizer. To evaluate the occlusion of exposed dentinal tubules, tooth surface was examined by SEM. Following results were observed. After ultrasonic scaling, more dentinal tubules were exposed on the tooth with non-carious cervical lesions compared to tooth without lesions. The rate of fluid flow measured with nano-Flow system had correlation with the degree of dentin occlusion observed with SEM after application of desensitizers on exposed dentin. Desensitizers with glutaraldehyde and HEMA did not decrease the rate of fluid flow and did not show dentin occlusion. Desensitizers with oxalate showed the limited effects on the rate of fluid flow and dentinal tubule occlusion. Desensitizer with resin monomer showed the significant effect on the rate of fluid flow and dentin occlusion.

Measurement of 137Cs in Ice Core Samples from Antarctica

  • Lim, S.I.;Kim, D.H.;Huh, J.Y.;Lee, J.;Hahn, I.S.;Han, Y.C.;Hur, S.D.;Hwang, H.J.;Kang, W.G.;Kim, Y.D.;Lee, E.K.;Lee, M.H.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1263-1268
    • /
    • 2018
  • Three different ice core samples from Antarctica were analyzed to identify activity concentrations of radioactive isotopes. Tracking migration of radioactive isotopes to Antarctica can provide a key clue to understand global environmental changes caused by radiation exposures because the Antarctic ice cores can preserve unique characteristics of various environmental conditions. We are particularly interested in the $^{137}Cs$ nucleus, because it is closely related to radiation exposure from nuclear power plant accidents and nuclear bomb tests. With its half life of $30.17{\pm}0.03$ years, $^{137}Cs$ can also be used to assess the age of sedimentation occurring after around the year 1945. We selected three ice core samples, called Tarn8, Styx27, and H25, from different time periods; the Tarn8 sample is known to be from earlier than ~ 1000 AD, the Styx27 sample is approximately from the year 1945, and the H25 sample is from the year 2012. Radioactive isotope measurements of the ice core samples were performed using a 100% HPGe detector at Cheongpyeong Underground Radiation Laboratory (CURL). We measured the activity of $^{137}Cs$ in the H25 sample to be $0.98{\pm}0.82mBq/kg$. Although the activity has a large uncertainty mainly due to the limited sample quantity, the $^{137}Cs$ isotopes in the Antarctic ice core were measured for the first time in Korea.