• Title/Summary/Keyword: limited measurements

Search Result 541, Processing Time 0.026 seconds

Utility of Multidetector Computed Tomographic Angiography as an Alternative to Transesophageal Echocardiogram for Preoperative Transcatheter Mitral Valve Repair Planning

  • Craig Basman;Caroline Ong;Tikal Kansara;Zain Kassam;Caleb Wutawunashe;Jennifer Conroy;Arber Kodra;Biana Trost;Priti Mehla;Luigi Pirelli;Jacob Scheinerman;Varinder P Singh;Chad A Kliger
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.1
    • /
    • pp.18-23
    • /
    • 2023
  • BACKGROUND: Three-dimensional (3D) transesophageal echocardiogram (TEE) is the gold standard for the diagnosis of degenerative mitral regurgitation (dMR) and preoperative planning for transcatheter mitral valve repair (TMVr). TEE is an invasive modality requiring anesthesia and esophageal intubation. The severe acute respiratory syndrome coronavirus 2 pandemic has limited the number of elective invasive procedures. Multi-detector computed tomographic angiography (MDCT) provides high-resolution images and 3D reconstructions to assess complex mitral anatomy. We hypothesized that MDCT would reveal similar information to TEE relevant to TMVr, thus deferring the need for a preoperative TEE in certain situations like during a pandemic. METHODS: We retrospectively analyzed data on patients who underwent or were evaluated for TMVr for dMR with preoperative MDCT and TEE between 2017 and 2019. Two TEE and 2 MDCT readers, blinded to patient outcome, analyzed: leaflet pathology (flail, degenerative, mixed), leaflet location, mitral valve area (MVA), flail width/gap, anterior-posterior (AP) and commissural diameters, posterior leaflet length, leaflet thickness, presence of mitral valve cleft and degree of mitral annular calcification (MAC). RESULTS: A total of 22 (out of 87) patients had preoperative MDCT. MDCT correctly identified the leaflet pathology in 77% (17/22), flail leaflet in 91% (10/11), MAC degree in 91% (10/11) and the dysfunctional leaflet location in 95% (21/22) of patients. There were no differences in the measurements for MVA, flail width, commissural or AP diameter, posterior leaflet length, and leaflet thickness. MDCT overestimated the measurements of flail gap. CONCLUSIONS: For preoperative TMVr planning, MDCT provided similar measurements to TEE in our study.

Comparative Analysis of Noise Characteristics by Road Pavement Types as Measurement Methods (측정 방법에 따른 도로 포장 종류별 소음 특성 비교 연구)

  • Guk-Gon Song;Seok-Kyeong Bae;Woo-Young Cho;Hyun-Woo Cho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.5
    • /
    • pp.47-53
    • /
    • 2024
  • This study investigates the noise reduction effects of various road pavement methods to mitigate traffic noise caused by the increasing proximity between roads and residential areas in urban environments. The noise characteristics of four types of road pavement-Dense Asphalt Concrete (DAC), Double Layer Porous Asphalt Concrete (DLPAC), Transverse Tining Concrete (TTC), and Exposed Aggregate Concrete (EAC)-were evaluated using CPX close-proximity noise and pass-by noise measurements. The CPX measurements showed that noise levels increased logarithmically with vehicle speed for all pavements. Specifically, DLPAC demonstrated higher noise levels in the low-frequency range below 800 Hz and lower noise levels in the high-frequency range, which is attributed to resonance effects within the internal pores of the pavement and the reduction of compression and expansion noise. In pass-by noise measurements, DLPAC exhibited higher low-frequency noise compared to DAC, likely due to pavement durability deterioration and the influence of external environmental noise. The results indicate that the CPX measurement method is more effective in evaluating road noise performance as it better reflects the impact of vehicle speed. However, since the study was conducted under limited site conditions, further research across various sites and conditions is necessary to enhance reliability.

Validation of GOCI-II Products in an Inner Bay through Synchronous Usage of UAV and Ship-based Measurements (드론과 선박을 동시 활용한 내만에서의 GOCI-II 산출물 검증)

  • Baek, Seungil;Koh, Sooyoon;Lim, Taehong;Jeon, Gi-Seong;Do, Youngju;Jeong, Yujin;Park, Sohyeon;Lee, Yongtak;Kim, Wonkook
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_1
    • /
    • pp.609-625
    • /
    • 2022
  • Validation of satellite data products is critical for subsequent analysis that is based on the data. Particularly, performance of ocean color products in turbid and shallow near-land ocean areas has been questioned for long time for its difficulty that stems from the complex optical environment with varying distribution of water constituents. Furthermore, validation with ship-based or station-based measurements has also exhibited clear limitation in its spatial scale that is not compatible with that of satellite data. This study firstly performed validation of major GOCI-II products such as remote sensing reflectance, chlorophyll-a concentration, suspended particulate matter, and colored dissolved organic matter, using the in-situ measurements collected from ship-based field campaign. Secondly, this study also presents preliminary analysis on the use of drone images for product validation. Multispectral images were acquired from a MicaSense RedEdge camera onboard a UAV to compensate for the significant scale difference between the ship-based measurements and the satellite data. Variation of water radiance in terms of camera altitude was analyzed for future application of drone images for validation. Validation conducted with a limited number of samples showed that GOCI-II remote sensing reflectance at 555 nm is overestimated more than 30%, and chlorophyll-a and colored dissolved organic matter products exhibited little correlation with in-situ measurements. Suspended particulate matter showed moderate correlation with in-situ measurements (R2~0.6), with approximately 20% uncertainty.

Influence of Substrate on Mechanical Characteristics of ZnO Thin Film by NI Technology (NI법에 의한 기계적 특성에 미치는 ZnO박막의 기판재의 영향)

  • Jung Hun-Cbae;KIM Dong-Hyun;Yoon Han-Ki;Lim Hee-Sup;Yu Yun-Sik
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.342-346
    • /
    • 2004
  • Recently there has been a great world-wide interest in developing and characterizing new nano-structured materials. These newly developed materials are often prepared in limited quantities and shapes unsuitable for the extensive mechanical testing. The development of depth sensing indentation methods have introduced the advantage of load and depth measurement during the indentation cycle. In the present work, ZnO thin films are prepared on the Glass, GaAs(100), Si(111), and Si(100) substrates at different temperatures by pulsed laser deposition(PLD) method. Because the potential energy in c-axis is law, the films always shaw c-axis orientation at the optimized conditions in spite of the different substrates. Thin films are investigated by X-ray diffractometer and Nano indentation equipment. From these measurements it is possible to get elastic modulus and hardness of ZnO thin films on all substrates.

  • PDF

EFFECTS OF NICARBAZIN AND HOT TEMPERATURE ON EVAPORATIVE WATER LOSS, ACID-BASE BALANCE, BODY TEMPERATURE AND CARBON DIOXIDE EXHALATION IN ADULT ROOSTERS

  • Lee, B.D.;Lee, S.K.;Hyun, W.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.1
    • /
    • pp.97-101
    • /
    • 1994
  • Two experiments were conducted to study the effect of ambient temperature and nicarbazin on SCWL adult roosters. In Experiment 1, the effects of nicarbazin supplementation (125 ppm) on the water metabolism, blood acid-base balance; and rectal temperature of 16 birds in normal ($21^{\circ}C$) and hot ($35-36^{\circ}C$) temperature were investigated. In Experiment 2, the evaporative water loss and $CO_2$ exhalation from 8 birds were measured individually with an open-circuit gravimetric respiration apparatus in normal ($21^{\circ}C$) and hot ($33.5-34^{\circ}C$) temperature. The amount of water intake and evaporative water loss increased in birds under heat stress (HS). Nicarbazin exacerbated these effect in hot temperature. Also, nicarbazin decreased the blood $pCO_2$ and increased pH of HS birds. The rectal temperature of birds increased in hot temperature, and nicarbazin worsened this effect. The evaporative water loss, measured directly with respiration apparatus (Experiment 2), was increased in hot temperature. HS decreased the amount of $CO_2$ exhalation. Nicarbazin did not exert ant effect on either of these measurements, probably due to the limited duration (2 h) of the trial. The decrease in $CO_2$ exhalation by HS birds could be explained by reduced metabolic rate, which helps homeothermy of birds in hot temperature.

Low energy ultrasonic single beacon localization for testing of scaled model vehicle

  • Dubey, Awanish C.;Subramanian, V. Anantha;Kumar, V. Jagadeesh
    • Ocean Systems Engineering
    • /
    • v.9 no.4
    • /
    • pp.391-407
    • /
    • 2019
  • Tracking the location (position) of a surface or underwater marine vehicle is important as part of guidance and navigation. While the Global Positioning System (GPS) works well in an open sea environment but its use is limited whenever testing scaled-down models of such vehicles in the laboratory environment. This paper presents the design, development and implementation of a low energy ultrasonic augmented single beacon-based localization technique suitable for such requirements. The strategy consists of applying Extended Kalman Filter (EKF) to achieve location tracking from basic dynamic distance measurements of the moving model from a fixed beacon, while on-board motion sensor measures heading angle and velocity. Iterative application of the Extended Kalman Filter yields x and y co-ordinate positions of the moving model. Tests performed on a free-running ship model in a wave basin facility of dimension 30 m by 30 m by 3 m water depth validate the proposed model. The test results show quick convergence with an error of few centimeters in the estimated position of the ship model. The proposed technique has application in the real field scenario by replacing the ultrasonic sensor with industrial grade long range acoustic modem. As compared with the existing systems such as LBL, SBL, USBL and others localization techniques, the proposed technique can save deployment cost and also cut the cost on number of acoustic modems involved.

A Study on the Applicability of Smart-phone Accelerometer for the Measurement of Dynamic Behavior in Bridges (교량의 동적 거동 계측을 위한 스마트폰 가속도센서의 적용성에 관한 연구)

  • Lee, Hyeong-Jin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.5
    • /
    • pp.747-756
    • /
    • 2020
  • In recent years, measurement in a smart-phone environment is attracting attention in various fields due to its easy set-up process, various functions, convenience and expandability. Even in the field of safety evaluation and maintenance of large-scale infra-structures, the appropriate application of these effective and convenient measurement techniques can be of great help. In this paper, an experimental study was conducted to investigate the effectiveness, problems and complementary methods of applying smart-phone accelerometers to the measurement in infra-structure such as bridges. In model bridge subjected to impact and moving loads, the measured accelerations using a smart-phone and a professional accelerometer were directly compared in time domain. And the statistical and frequency characteristics of the measured signal and transfer function were also examined in frequency domain. The results show that the accuracy of measurement using smart-phone sensor is primarily affected by its incomplete sampling performance. In conclusion, smart-phone sensors cannot be considered suitable for precise assessment, where measurements must be accurate over a wide frequency range, but we can say that the technique is still useful and fairly accurate for some purpose over a limited frequency range, such as the low pass frequency range, which is a major concern for civil structures.

Transformation of Shophouses in Phnom Penh, Cambodia: In the Aspect of Spatial Organization (캄보디아 프놈펜의 숍하우스의 변형에 관한 연구: 공간조직적 측면에서)

  • Yam, Sokly;Ju, Seo Ryeung
    • Human Ecology Research
    • /
    • v.54 no.1
    • /
    • pp.13-26
    • /
    • 2016
  • The purpose of this paper is to investigate the rationale behind the transformation process of unique shophouse spatial organization in Phnom Penh. We selected 20 representative shophouses located in the Chinese district of Phnom Penh according to construction period. A qualitative study methodology was applied and field surveys were conducted that included interviews with residents, photographs, sketches, measurements, collecting historic photos, and cataloging maps. Selected cases were analyzed in terms of: basic house data, urban block analysis, and unit analysis. Cases were then classified into two types: private courtyard shophouse (PCS) and shared courtyard shophouse (SCS). PCS refers to shophouse typology that maintains most of the characteristics of early shophouses while being transformed into a modern multi-story apartment within a limited one bay plot. However, SCS refers to shophouses adapted from the indigenous forms of PCS that evolved into a multi-storey and multi-family housing typology that includes features that might have been adapted from Western apartment buildings such as sharing a big courtyard, staircase and corridors. We conclude that shophouses in Phnom Penh have positively adopted a Western building typology, adapted it to local traditions, and finally formulated a new building type that represent indicators of a modernization process gradually accepted by society.

The Effects of Pilates Mat Exercise on Trunk Muscle Thickness and Balance

  • Han, Jung-Soo;Cho, Woon-Su;Lim, Jae-Heon
    • The Journal of Korean Physical Therapy
    • /
    • v.29 no.4
    • /
    • pp.201-206
    • /
    • 2017
  • Purpose: The aim of this study was to identify the effects of Pilates mat exercise may improve trunk muscle thickness and balance in healthy adults. Methods: Eighteen healthy adults participated in this study. They were randomly assigned to one of two groups: Pilates mat exercise group (n=9) and the control group (n=9). Subjects in Pilates mat exercise group performed the exercises three days per week for 6 weeks, which consisted of warm up, main workout, and cool down. Trunk muscle thickness of the rectus abdominis (RA), internal oblique (IO), external oblique (EO), transverse abdominis (TrA), multifidus (MF), and erector spine (ES) were measured using an ultrasonography. Balance ability was evaluated using Romberg test and limits of stability (LOS). Measurements were performed before training, 3 weeks after training, and 6 weeks after training. Results: There was a significant difference of RA, EO, IO, MF, and ES according to the main effect of time (p<0.05). There was a significant difference of EO, MF, ES, Romberg, and LOS according to interaction effect between the time and group (p<0.05). There was a significant difference only for LOS according to the main effect of the group (p<0.05). Conclusion: Pilates mat exercise did increase trunk muscle thickness and balance. However, the effect with respect to trunk thickness was limited. Pilates mat exercise appears to be more effective in improving muscles related to trunk extension and balance.

THE SOLAR-B MISSION

  • ICHIMOTO KIYOSHI;TEAM THE SOLAR-B
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.307-310
    • /
    • 2005
  • The Solar-B is the third Japanese spacecraft dedicated for solar physics to be launched in summer of 2006. The spacecraft carries a coordinated set of optical, EUV and X-ray instruments that will allow a systematic study of the interaction between the Sun's magnetic field and its high temperature, ionized atmosphere. The Solar Optical Telescope (SOT) consists of a 50cm aperture diffraction limited Gregorian telescope and a focal plane package, and provides quantitative measurements of full vector magnetic fields at the photosphere with spatial resolution of 0.2-0.3 arcsec in a condition free from terrestrial atmospheric seeing. The X-ray telescope (XRT) images the high temperature (0.5 to 10 MK) corona with improved spatial resolution of approximately 1 arcsec. The Extreme Ultraviolet Imaging Spectrometer (EIS) aims to determine velocity fields and other plasma parameters in the corona and the transition region. The Solar-B telescopes, as a whole, will enable us to explore the origins of the outer solar atmosphere, the corona, and the coupling between the fine magnetic structure at the photosphere and the dynamic processes occurring in the corona. The mission instruments (SOT/EIS/XRT) are joint effort of Japan (JAXA/NAO), the United States (NASA), and the United Kingdom (PPARC). An overview of the spacecraft and its mission instruments are presented.