• Title/Summary/Keyword: limit temperature

Search Result 1,365, Processing Time 0.026 seconds

Measurement and Prediction of the Combustible Properties of n-Butyl methacrylate(n-BMA) (n-Butyl methacrylate(n-BMA)의 연소특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.4
    • /
    • pp.42-47
    • /
    • 2016
  • The combustible properties(flash point, explosion limit and autoignition temperature) are the important safety items which are considered in the typical MSDS(material safety data sheet). In this study, for the safe handling of n-butyl methacrylate(n-BMA) being used in various ways in the chemical industry, the flash point and the autoignition temperature(AIT) of n-butyl methacrylate was experimented. And, the lower explosion limit of n-butyl methacrylate was calculated by using the lower flash point obtained in the experiment. The flash points of n-butyl methacrylate by using the Setaflash and Pensky-Martens closed-cup testers measured $44^{\circ}C$ and $51^{\circ}C$, respectively. The flash points of n-butyl methacrylate by using the Tag and Cleveland open cup testers are measured $53^{\circ}C$. The AIT of n-butyl methacrylate by ASTM 659E tester was measured as $295^{\circ}C$. The lower explosion limit by the measured flash point $44^{\circ}C$ was calculated as 0.85 vol.%. It was possible to predict lower explosion limit by using the experimental flash point or flash point in the literature.

Evaluation of the Formability of Warm Forming Simulation of Magnesium Alloy Sheet Using FLD (마그네슘 합금 판재의 온간 성형 해석에서 FLD를 이용한 성형성 평가)

  • Lee, M.H.;Kim, K.K.;Kim, H.Y.;Oh, S.I.
    • Transactions of Materials Processing
    • /
    • v.17 no.7
    • /
    • pp.501-506
    • /
    • 2008
  • In this study, a forming magnesium alloy circular cup was simulated accounting for heat transfer at elevated temperatures. In order to predict the failure of magnesium alloy sheet during simulation, the forming limit diagram, which is used in sheet metal forming analysis to determine the criterion for failure, was investigated. For the failure prediction in the simulation accounting for heat transfer, the forming limit diagram for a temperature the same as the temperature of the blank element was used. The result of the simulation showed that the drawn depth increases with the increase of the die-holder temperature, and is in accord with the experimental results above the die-holder temperature of $150^{\circ}C$. The forming limit diagram provided a good guide for the failure prediction of warm forming simulation accounting for heat transfer. In addition, the effect of the tool shoulder radius on the drawn depth at various tool temperatures is verified using the simulation conditions which agreed with the experimental results.

Generation of Pressure/Temperature Limit Curve for Reactor Operation (원자로 운전을 위한 압력/온도 한계곡선의 설정)

  • 정명조;박윤원
    • Computational Structural Engineering
    • /
    • v.10 no.4
    • /
    • pp.155-164
    • /
    • 1997
  • A reactor pressure vessel, which contains fuel assemblies and reactor vessel internals, has the thermal stress resulting from the cool-down and heat-up of the vessel wall in combination with the pressure stress from system pressure resulting in large stresses. The combination of the pressure stress and thermal stress along with a decrease in fracture toughness may cause through-wall propagation of a relatively small crack. Therefore, it is necessary to define the relations between operating pressure and temperature during cool-down and heat-up. In this study, theory of fracture mechanics for a pressure/temperature limit curve is investigated and a numerical procedure for generating it is developed. Plant-specific limit curves for the Kori unit 1 plant, the oldest nuclear power plant in Korea, have been obtained for several cooling and heating rates and their results are discussed.

  • PDF

Steady-state and Transient Performance Simulation and Limit Control for Compressor Surge and Turbine Over-temperature of Turboprop Engine (PT6A-62) (터보프롭 엔진(PT6A-62)의 동.정적 성능모사와 압축기 서지 및 터빈 자온 제어연구)

  • 공창덕;기자영;강명철
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.6 no.2
    • /
    • pp.53-63
    • /
    • 2002
  • The steady-state and transient performance simulation program for a turboprop engine(PT6A-62) was developed. Specially this program included some algorithms, such as flat-rated behaviors in performance and limit control algorithms to prevent the compressor surge and the compressor-turbine inlet limit temperature overshoot. In order to minimize analysis errors, on interpolation method in component characteristics using matching errors and specific heat and specific heat ratio, which are functions of temperatures were used. The developed steady state performance analysis program can handle various conditions such as altitude, bleed extraction, inlet temperature and pressure and part throttle, and the transient performance analysis program incorporated a general mode for transient simulation and a control mode for prevention of the compressor surge and the turbine inlet limit temperature overshoot.

Time dependent heat transfer of proliferation resistant plutonium

  • Lloyd, Cody;Hadimani, Ravi;Goddard, Braden
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.510-517
    • /
    • 2019
  • Increasing proliferation resistance of plutonium by way of increased $^{238}Pu$ content is of interest to the nuclear nonproliferation and international safeguards community. Considering the high alpha decay heat of $^{238}Pu$, increasing the isotopic fraction leads to a noticeably higher amount of heat generation within the plutonium. High heat generation is especially unattractive in the scenario of weaponization. Upon weaponization of the plutonium, the plutonium may generate enough heat to elevate the temperature in the high explosives to above its self-explosion temperature, rendering the weapon useless. In addition, elevated temperatures will cause thermal expansion in the components of a nuclear explosive device that may produce thermal stresses high enough to produce failure in the materials, reducing the effectiveness of the weapon. Understanding the technical limit of $^{238}Pu$ required to reduce the possibility of weaponization is key to reducing the current limit on safeguarded plutonium (greater than 80 at. % $^{238}Pu$). The plutonium vector evaluated in this study was found by simulating public information on Lightbridge's fuel design for pressurized water reactors. This study explores the temperature profile and maximum stress within a simple (first generation design) hypothetical nuclear explosive device of four unique scenarios over time. Analyzing the transient development of both the temperature profile and maximum stress not only establishes a technical limit on the $^{238}Pu$ content, but also establishes a time limit for which each scenario would be useable.

High Temperature Tensile Strength and Fatigue Life Characteristics for Reduced Activation Ferritic Steel (JLF-1) by TIG Welding (TIG 용접한 저방사화 페라이트강 (JLF-1)의 고온강도 및 피로수명특성)

  • Yoon, Han-Ki;Lee, Sang-Pill;Kim, Sa-Woong;Kohyama, Akira
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1444-1450
    • /
    • 2003
  • The fatigue life and tensile strength of JLF-1 steel (Fe-9Cr-2W-V-Ta) and its TIG weldment were investigated at the room temperature and $400^{\circ}C$. Four kinds of test specimens, which associated with the rolling direction and the TIG welding direction were machined. The base metal of JLF-1 steel represented almost anisotropy in the tensile properties for the rolling direction. And the base metal of JLF-1 steel showed lower strength than that of TIG weldment. Also, the strength of all materials entirely decreased in accordance with elevating test temperature. Moreover, the fatigue limit of weld metal was largely increase than that of base metal at both temperatures. The fatigue limit of JLF-1 steel decreased in accordance with elevating test temperature. The fatigue limit of JLF-1 steel decreased in accordance with elevating test temperature. The SEM fractography of tensile test specimen showed conspicuous cleavage fracture of a radial shape. In case of fatigue life test specimen, there were so many striations at crack initiation region, and dimple was observed at final fracture region as a ductile fracture mode.

The Impact of Temperature Rising on the Distribution of Plant - in Case of Bamboos and Garlics - (우리나라에서 기온 상승이 식생분포에 미치는 영향 - 대나무와 마늘을 중심으로 -)

  • Heo, Inhye;Kwon, Won-Tae;Chun, Youngmoon;Lee, Seungho
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.1
    • /
    • pp.67-78
    • /
    • 2006
  • Global warming brings about changes of diverse environmental, especially changes of plant distribution. The purpose of this paper is to examine the relationship between temperature rise and changes of northern limit of vegetation growth in Korea. Bamboos (Phyllostachys) and boundary between the northern type and southern type of garlic (Allium sativum L.) were selected. The data of the distributions of bamboos and garlic are collected by field survey and interviews. Temperature is analyzed from 1904 to 2000. The northern limit of Phyllostachys moves 60-100 km northward, for about 100 years, the period of 1907-2003 and mean temperature of Korea increases about $2^{\circ}C$ during the same period. It means that the northern limit moves 30-50 km northward, for each $1^{\circ}C$ rising of January mean temperature. The boundary between the northern type and southern types of garlic moves northward 40-140 km from 1980s to 2000. The moving width is broad in the west coastal region while the width is narrow in the inland and mountain regions. The mean moving width is about 100 km.

Mass constraint and temperature estimation of eruptive plasma in X-ray

  • Lee, Jin-Yi;Raymond, John C.;Reeves, Katharine K.;Moon, Yong-Jae;Kim, Kap-Sung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.60.2-60.2
    • /
    • 2013
  • We investigate several eruptive hot plasma observations by Hinode/XRT. Their corresponding EUV and/or white light CME features are visible in some events. Using those observations, we determine the mass constraints of eruptive plasma by assuming simplified geometrical structures of the plasma. In some events, their associated prominence eruptions and eruptive plasma were observed in EUV observations as absorption or emission features. The absorption feature provides the lower limit to the cold mass while the emission feature provides the upper limit to the mass of observed eruptive plasma in X-ray and EUV passbands. We compare the mass constraints for each temperature responses and find that the mass in EUV and XRT are smaller in their upper or lower limit than total mass in coronagraph. About half eruptive events in XRT have no corresponding CME, which may be due to failed eruptions or low plasma density. In addition, some events were observed by a few passbands in X-ray, which allows the determination of the eruptive plasma temperature using a filter ratio method. We present the isothermal plasma temperatures by the filter ratio method. These are possibly an average temperature for higher temperature plasma because the XRT is more sensitive in higher temperature.

  • PDF

Prediction of Temperature Dependence of Explosion Limits and Interrelationship of Explosion Characteristics for Akylketones (알킬케톤류의 폭발 특성치 간의 상관관계 및 폭발한계의 온도의존성 예측)

  • Ha Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.2 s.31
    • /
    • pp.7-13
    • /
    • 2006
  • In order to evaluate the fire and explosion involved and to ensure the safe and optimized operation of chemical processes, it is necessary to know combustion characteristics. The explosion limit, the heat of combustion, flame temperature and temperature dependence of the lower explosive limit are the major combustion characteristics used to determine the fire and explosion hazards of the flammable substances. The aim of this study is to investigate interrelationship of explosion characteristics and the temperature dependence of the lower explosion limit at elevated temperature for akylketones. By using the reference data, the empirical equations which describe the interrelationships of explosion properties of akylketones have been derived. Also, the new equations using the mathematical and statistical methods for predicting the temperature dependence of lower explosion limits of akylketones on the basis of the literature data are proposed. The values calculated by the proposed equations agreed with literature data within a few percent. From the given results, using the proposed methodology, it is possible to predict the explosion limits of the other flammable substances.

  • PDF

Fire Retardant Treatment to the Plywood with Di-ammonium Phosphate [(NH4)2HPO4] (II) - Effect of Platen Temperature on Bending Strength of Treated Plywoods - (제2인산(第二燐酸) 암모늄에 의(依)한 합판(合板)의 내화처리(耐火處理)(II) - 열판온도(熱板溫度)가 처리합판(處理合板)의 곡강도(曲强度)에 미치는 영향(影響) -)

  • Chung, Woo-Yang;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.3-9
    • /
    • 1984
  • This study was carried out to examine the practicality of DAP[$(NH_4)_2HPO_4$] as fire retardant for plywood by static bending test the redried plywoods which had been soaked in 20% $(NH_4)_2HPO_4$ solution. Being hot/cold soaked in the solution for 3/3, 6/3, 9/3 and 12/3 hours and redried by cyclic press-drying method at the platen temp. of 130, 145, 100 and $175^{\circ}C$, the treated plywoods were tested to offer the mechanical data, that is, $S_{pl}$(stress at proportional limit), MOE(modulus of elasticity), MOR(modulus of rupture) and $W_{pl}$(work per unit volume to proportional limit ) in flexure. The results obtained were summarized as follows. 1. $S_{pl}$ of fire retardant treated plywoods ("FRP" would be used hereinafter) decreased as the platen temperature increased, but it was superior to that of non-treated plywoods(Control) at $160^{\circ}C$ or higher. 2. MOE of FRP decreased roughly with the increase of temperature, hut this tendency was not constant. And the value of FRP was higher than that of Control even at $175^{\circ}C$. 3. MOR of FRP showed same temperature-dependent tendency as MOE, but it was influenced more sensitively at the higher temperature. 4. $W_{pl}$ of FRP also decreased gradually with the increase of platen temperature and the value in DAP 9/3 treatment was Jess than 70% of control plywoods. 5. In view of redrying time and mechanical properties, the most reasonable platen temperature for DAP treated FRP was $160^{\circ}C$ in this study.

  • PDF