• Title/Summary/Keyword: limit state model

Search Result 342, Processing Time 0.027 seconds

Supercapacitor Applications for System Stabilization and Efficiency Improvement on DC Railway System (직류 도시철도 시스템 에너지 효율 향상 및 안정화를 위한 슈퍼커패시터 에너지 저장장치 활용 방안 연구)

  • Song, Ji-Young;Lee, Kye-Byung;Lee, Han-Sang;Jang, Gil-Soo;Kwon, Sae-Hyuk;Lee, Chang-Mu;Lee, Han-Min;Kim, Gil-Dong
    • Journal of IKEEE
    • /
    • v.13 no.1
    • /
    • pp.49-56
    • /
    • 2009
  • In this paper, a simulation for the stability of the catenary voltage through charging and discharging by introducing an energy storage system in the railway system and the efficient usage of restoration energy has been performed. In order for the simulation, a simple railway model with an appropriate control technique has been introduced. The catenary voltage area is divided into two areas with voltage control and an area with normal operation and current control is performed to satisfy current limit of the supercapacitor. We confirmed the energy absorption and emission through the simulation and observed energy efficiency through charging and discharging according to the operation state of the railway.

  • PDF

Static performance of a new GFRP-metal string truss bridge subjected to unsymmetrical loads

  • Zhang, Dongdong;Yuan, Jiaxin;Zhao, Qilin;Li, Feng;Gao, Yifeng;Zhu, Ruijie;Zhao, Zhiqin
    • Steel and Composite Structures
    • /
    • v.35 no.5
    • /
    • pp.641-657
    • /
    • 2020
  • A unique lightweight string truss deployable bridge assembled by thin-walled fiber reinforced polymer (FRP) and metal profiles was designed for emergency applications. As a new structure, investigations into the static structural performance under the serviceability limit state are desired for examining the structural integrity of the developed bridge when subjected to unsymmetrical loadings characterized by combined torsion and bending. In this study, a full-scale experimental inspection was conducted on a fabricated bridge, and the combined flexural-torsional behavior was examined in terms of displacement and strains. The experimental structure showed favorable strength and rigidity performances to function as deployable bridge under unsymmetrical loading conditions and should be designed in accordance with the stiffness criterion, the same as that under symmetrical loads. In addition, a finite element model (FEM) with a simple modeling process, which considered the multi segments of the FRP members and realistic nodal stiffness of the complex unique hybrid nodal joints, was constructed and compared against experiments, demonstrating good agreement. A FEM-based numerical analysis was thereafter performed to explore the effect of the change in elastic modulus of different FRP elements on the static deformation of the bridge. The results confirmed that the change in elastic modulus of different types of FRP element members caused remarkable differences on the bending and torsional stiffness of the hybrid bridge. The global stiffness of such a unique bridge can be significantly enhanced by redesigning the critical lower string pull bars using designable FRP profiles with high elastic modulus.

A Study on Policy for the Introduction of BIM in Architectural Service Industry (건축서비스산업 BIM 도입 및 활용을 위한 중장기 정책제안)

  • Kim, Yong Jun;Kim, Hong-Su;Back, Min-Suk
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.4
    • /
    • pp.363-377
    • /
    • 2016
  • The introduction of the BIM into the architectural service industry is currently not being conducted smoothly. The purpose of this research is to, considering the current state of the market, establish long-term strategies that will enable the BIM to successfully settle. The survey has been conducted in target of architects in order to understand pending issues. Additionally, the articles regarding BIM have been researched for the purpose of better understanding the current societal demands. Indicated by survey results, the architects agree to a certain extent upon the need of BIM for architectural designs, yet also express concerns that the BIM introduction does not guarantee betterment in efficiency. The problematic aspects of BIM introduction that have already been discussed in some policy-related studies include a multitude of complicated issues that are unable to be resolved within a short period of time: underdeveloped BIM infra, the limit of BIM software itself, political issues regarding licensing and lack of social awareness. Based on the issues mentioned above, three main areas of focus along with their respective practical strategies and tasks have been designated. Finally, this research has analyzed the current situation and its issues along with the political solutions of 12 projects, amongst which include the standard for plan drawings, licensing system improvement, cost standard and BIM introduction support. Finally this research has analyzed the current situations and its' issues along with the political solutions of 12 projects, amongst them are the standard for plan drawings, licensing system improvement, cost standard and BIM introduction support.

An Experimental Study on the Structural Performance of Horizontally Curved Precast PSC Girder (프리캐스트 곡선 PSC 거더의 구조 성능에 관한 실험연구)

  • Lee, Doo Sung;Choi, Woo Suk;Kim, Tae Kyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.747-757
    • /
    • 2015
  • The main purpose of this study is to investigate the static behavior of a horizontally curved prestressed concrete (PSC) girder. A 30m long full-scale curved PSC girder with 80.0m radius is fabricated by a portable curved form system. Deflections and concrete strains at the middle of span were measured. The obtained experimental results have been compared to those from F.E.A. analysis. When a initial crack developed, the applied load was 1.3 times the service design load and the vertical deflection at the middle of span satisfied the requirement for a live load state according to the Korea Bridge Design Specifications (2010). Also, the ductility of the full scale specimen satisfied the limit in the Specifications (2010). To verify the experimental results, a numerical F.E. analysis was carried and confirmed that the data were similar with results from the test above. The horizontally curved PSC girder fabricated on site was found to have enough strength for safety under and after construction.

Monitoring of Chemical Processes Using Modified Scale Space Filtering and Functional-Link-Associative Neural Network (개선된 스케일 스페이스 필터링과 함수연결연상 신경망을 이용한 화학공정 감시)

  • Park, Jung-Hwan;Kim, Yoon-Sik;Chang, Tae-Suk;Yoon, En-Sup
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.12
    • /
    • pp.1113-1119
    • /
    • 2000
  • To operate a process plant safely and economically, process monitoring is very important. Process monitoring is the task to identify the state of the system from sensor data. Process monitoring includes data acquisition, regulatory control, data reconciliation, fault detection, etc. This research focuses on the data recon-ciliation using scale-space filtering and fault detection using functional-link associative neural networks. Scale-space filtering is a multi-resolution signal analysis method. Scale-space filtering can extract highest frequency factors(noise) effectively. But scale-space filtering has too large calculation costs and end effect problems. This research reduces the calculation cost of scale-space filtering by applying the minimum limit to the gaussian kernel. And the end-effect that occurs at the end of the signal of the scale-space filtering is overcome by using extrapolation related with the clustering change detection method. Nonlinear principal component analysis methods using neural network have been reviewed and the separately expanded functional-link associative neural network is proposed for chemical process monitoring. The separately expanded functional-link associative neural network has better learning capabilities, generalization abilities and short learning time than the exiting-neural networks. Separately expanded functional-link associative neural network can express a statistical model similar to real process by expanding the input data separately. Combining the proposed methods-modified scale-space filtering and fault detection method using the separately expanded functional-link associative neural network-a process monitoring system is proposed in this research. the usefulness of the proposed method is proven by its application a boiler water supply unit.

  • PDF

A Gaussian process-based response surface method for structural reliability analysis

  • Su, Guoshao;Jiang, Jianqing;Yu, Bo;Xiao, Yilong
    • Structural Engineering and Mechanics
    • /
    • v.56 no.4
    • /
    • pp.549-567
    • /
    • 2015
  • A first-order moment method (FORM) reliability analysis is commonly used for structural stability analysis. It requires the values and partial derivatives of the performance to function with respect to the random variables for the design. These calculations can be cumbersome when the performance functions are implicit. A Gaussian process (GP)-based response surface is adopted in this study to approximate the limit state function. By using a trained GP model, a large number of values and partial derivatives of the performance functions can be obtained for conventional reliability analysis with a FORM, thereby reducing the number of stability analysis calculations. This dynamic renewed knowledge source can provide great assistance in improving the predictive capacity of GP during the iterative process, particularly from the view of machine learning. An iterative algorithm is therefore proposed to improve the precision of GP approximation around the design point by constantly adding new design points to the initial training set. Examples are provided to illustrate the GP-based response surface for both structural and non-structural reliability analyses. The results show that the proposed approach is applicable to structural reliability analyses that involve implicit performance functions and structural response evaluations that entail time-consuming finite element analyses.

Critical Failure Condition of Reinforced Earth Wall by Photograph (사진촬영을 통한 보강토옹벽의 파괴조건 연구)

  • Ju, Jae-Woo;Kim, Seong-Tae;Kim, Jae-Young;Chang, Yong-Chai;Cho, Sam-Deok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.380-387
    • /
    • 2004
  • Recently the geosynthetics reinforced retaining wall has been widely used instead of the steel reinforced retaining wall. The geosynthetics reinforced retaining wall is a very dangerous structure if the geosynthetics lose their strength about tension or if it lose their pullout resistence, but it was known that the geosynthetics reinforced wall had a great resistence and was a very safe structure against a earthquake or a dynamic load. It can be said that most important factors in the stability of the geosynthetics reinforced wall are the horizontal length of reinforcement and the vertical distance between two reinforcements. That is to say, as the length of reinforcement is longer, the structure is more stable and as the vertical distance between two reinforcements is shorter, it is more stable. In this study, in order to get the critical condition with a safety rate of 1, various kinds of model tests about geosynthetics reinforced wall has been performed. Photos by B-shutter method has been taken during tests and from photos, which show us the failure state, the critical condition about failure has been conformed. Accordingly the equation, which says the limit of stability in geosynthetics reinforced wall., has been proposed.

  • PDF

A Basic Study on Safe Mooring Guide for Dangerous Goods Berths in Ul-San Port (울산항 위험물 부두의 안전계류에 관한 기초연구)

  • Kang, Won-Sik;Park, Young-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.67-73
    • /
    • 2016
  • This study analyzed the state of the vessels which were using the berth for dangerous goods more than its carrying capacity in the major dangerous cargo handling port of Ulsan in Korea, The result of the analysis showed that a ship which has 3 times more than the maximum berthing capacity was moored at berth. Accordingly, a simulation model for 50,000 DWT berth was built and carried out the mooring safety analysis with 50,000 DWT, 70,000 DWT and 100,000 DWT vessels by mooring assessment program. The evaluation was carried out according to the standard environment presented in OCIMF standards. 50,000 DWT vessel was evaluated to meet the acceptable criteria but, 70,000 DWT and 100,000 DWT vessels exceeded the acceptable limit as per external conditions. Consequently, safe mooring guidelines were suggested and also proposed the building of common 'Mooring safety guideline' for port with assessment of different cases.

An Examination of the Maximum Steel Ratio for Reinforced Concrete Flexural Members: Focused on Singly Reinforced Beam with Rectangular Cross-section (철근콘크리트 휨부재의 최대철근비에 대한 고찰: 단철근 직사각형보를 중심으로)

  • Lee, Jun-Seok;Kim, Woo;Choi, Seung-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.2
    • /
    • pp.179-187
    • /
    • 2017
  • The design provisions for the maximum steel ratio in reinforced concrete flexural members is normally provided to ensure sufficient ductility and economy by steel yielding at member failure. In the Concrete Structural Design Code (2012), the maximum steel ratio is expressed in terms of a net strain in tensile steel, and leading to very high steel ratio in the case of using high strength materials. Thereby, this may result in difficulty to satisfy a required workability at concrete placing. On the contrary, in the Korean Highway Bridge Design Code (Limit State Design) the maximum steel ratio is given in terms of the maximum neutral axis depth ratio that is 0.4. From these results, a rational model for the maximum steel ratio is suggested so as to satisfy a ductility as well as a workability.

Seismic risk assessment of concrete-filled double-skin steel tube/moment-resisting frames

  • Hu, Yi;Zhao, Junhai;Zhang, Dongfang;Zhang, Yufen
    • Earthquakes and Structures
    • /
    • v.14 no.3
    • /
    • pp.249-259
    • /
    • 2018
  • This paper aims to assess the seismic risk of a plane moment-resisting frames (MRFs) consisting of concrete-filled double skin steel tube (CFDST) columns and I-section steel beams. Firstly, three typical limit performance levels of CFDST structures are determined in accordance with the cyclic tests of seven CFDST joint specimens with 1/2-scaled and the limits stipulated in FEMA 356. Then, finite element (FE) models of the test specimens are built by considering with material degradation, nonlinear behavior of beam-column connections and panel zones. The mechanical behavior of the concrete material are modeled in compression stressed condition in trip-direction based on unified strength theory, and such numerical model were verified by tests. Besides, numerical models on 3, 6 and 9-story CFDST frames are established. Furthermore, the seismic responses of these models to earthquake excitations are investigated using nonlinear time-history analyses (NTHA), and the limits capacities are determined from incremental dynamic analyses (IDA). In addition, fragility curves are developed for these models associated with 10%/50yr and 2%/50yr events as defined in SAC project for the region on Los Angeles in the Unite State. Lastly, the annual probabilities of each limits and the collapse probabilities in 50 years for these models are calculated and compared. Such results provide risk information for the CFDST-MRFs based on the probabilistic risk assessment method.