• Title/Summary/Keyword: limit pressure ($P_1$)

Search Result 57, Processing Time 0.023 seconds

Explosion Hazards and Flame Velocity in Aluminum Powders (알루미늄 분체의 폭발위험성과 화염전파속도)

  • Han, Ou-Sup;Lee, Su-Hee
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.7-13
    • /
    • 2012
  • An experimental study has been done to investigate the explosion characteristics of aluminum powders with different sizes and concentrations in a 20 L spherical explosion vessel. Two different sizes of aluminum powder were used : $15.1{\mu}m$ and $34.8{\mu}m$ with a volume mean diameter. The results revealed that $15.1{\mu}m$ Al powder has a Lower explosion limit (LEL) of $40g/m^3$, a maximun explosion pressure ($P_{max}$) of 9.8 bar and a maximum rate of pressure rise ($[dP/dt]_{max}$) of 1852 bar/s, in $34.8{\mu}m$ Al powder, LEL of $70g/m^3$, $P_{max}$ of 7.9 bar and $[dP/dt]_{max}$ of 322 bar/s. The LEL of Al powders tended to increase with the increase of particle size. Also, it was found that the flame velocity calculated from the powder with $15.1{\mu}m$ was about 5 times higher than that of the powder of $34.8{\mu}m$.

High Hydrostatic Pressure Sterilization of Putrefactive Bacteria in Salted and Fermented Shrimp with Different Salt Content (염농도가 다른 새우젓에 존재하는 유해가능 세균의 초고압 살균)

  • Mok, Chul-Kyoon;Song, Ki-Tae
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.598-603
    • /
    • 2000
  • This study was conducted to enhance the storage stability and the wholesomeness of salted and fermented shrimp manufactured with different salt levels by high hydrostatic pressure sterilization. The effects of high hydrostatic pressure treatment on the putrefactive bacteria in the fermented shrimps were investigated and the sterilization kinetics was analyzed. The initial microbial counts of the fermented shrimp with 8%, 18% salt aged for 6 weeks at $20^{circ}C$ were $1.6{\times}10^3,\;1.4{\times}10^4$ CFU/g for bacteria grown on Vibrio selective media, $9.3{\times}10^3,\;1.7{\times}10^5$ CFU/g for bacteria grown on Staphylococcus selective media, respectively, and null for bacteria grown on Salmonella selective media. The degree of the sterilization increased with the magnitude of the pressure and the treatment time. The fermented shrimp pressurized at 6,500 atm for 10 min had no detectable bacteria grown on Vibrio and Staphylococcus selective media at $10^2$ CFU/g detecting limit. High hydrostatic pressure sterilization could be analyzed by first order reaction kinetics. The $D_P$ values of the bacteria grown on Vibrio selective media of the fermented shrimp at 18% salt were higher than those at 8% salt, while those of the bacteria grown on Staphylococcus selective media showed an inverse trend. The $z_p$ values of 8% salt fermented shrimp were higher than those of 18% salt for both bacteria grown on Vibrio selective media and Staphylococcus selective media. High hydrostatic pressure treatment could be applied for the sterilization of the fermented shrimp, and the optimum high pressure sterilization condition was 10 min treatment at 6,500 atm.

  • PDF

Oxygen Partial Pressure Dependency of Al-donor Solubility in ZnO (ZnO내 Al-도우너의 용해도의 산소분압 의존성)

  • 김은동;김남균
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.12
    • /
    • pp.1093-1096
    • /
    • 2001
  • The Solid solution of A $l_2$ $O_3$ into ZnO can be defined by the substitution reaction of Al$\^$3+/ ions into the Zn$\^$2+/ sites of ZnO crystal lattice, the tetrahedral interstices composed of four neighbor oxygen ions in the wurtzite structure. Since the reaction either creates new zinc vacancies or consumes the oxygen vacancies, it should be in equilibrium with ZnO nonstoichiometry and disorder reactions. The relationships make oxygen partial pressure P$\sub$o2/ control the concentrations of the vacancies and consequently limit the Al solubility in ZnO, [Al$\sub$zn/]$\sub$max/. This paper firstly reports with a refined model for defect quilibria in ZnO that the solubility decrease with the increase of P$\sub$o2/, [Al$\sub$zn/]$\sub$max/ P$\sub$o2/$\^$-1/4/.

  • PDF

The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites (산업장 소음의 강도 및 주파수 특성에 관한 조사연구)

  • Kim, Kwang Jong;Cha, Chul Whan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.2
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF

Removal of residual VOCs in a collection chamber using decompression for analysis of large volatile sample

  • Lee, In-Ho;Byun, Chang Kyu;Eum, Chul Hun;Kim, Taewook;Lee, Sam-Keun
    • Analytical Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.23-35
    • /
    • 2021
  • In order to measure the volatile organic compounds (VOCs) of a sample which is too large to use commercially available chamber, a stainless steel vacuum chamber (VC) (with an internal diameter of 205 mm and a height of 50 mm) was manufactured and the temperature of the chamber was controlled using an oven. After concentrating the volatiles of the sample in the chamber by helium gas, it was made possible to remove residual volatile substances present in the chamber under reduced pressure ((2 ± 1) × 10-2 mmHg). The chamber was connected to a purge & trap (P&T) using a 6 port valve to concentrate the VOCs, which were analyzed by gas chromatography-mass spectrometry (GC-MS) after thermal desorption (VC-P&T-GC-MS). Using toluene, the toluene recovery rate of this device was 85 ± 2 %, reproducibility was 5 ± 2 %, and the detection limit was 0.01 ng L-1. The method of removing VOCs remaining in the chamber with helium and the method of removing those with reduced pressure was compared using Korean drinking water regulation (KDWR) VOC Mix A (5 μL of 100 ㎍ mL-1) and butylated hydroxytoluene (BHT, 2 μL of 500 ㎍ mL-1). In case of using helium, which requires a large amount of gas and time, reduced pressure ((2 ± 1) × 10-2 mmHg) only during the GC-MS running time, could remove VOCs and BHT to less than 0.1 % of the original injection concentration. As a result of analyzing volatile substances using VC-P&T-GC-MS of six types of cell phone case, BHT was detected in four types and quantitatively analyzed. Maintaining the chamber at reduced pressure during the GC-MS analysis time eliminated memory effect and did not affect the next sample analysis. The volatile substances in a cell phone case were also analyzed by dynamic headspace (HT3) and GC-MS, and the results of the analysis were compared with those of VC-P&T-GC-MS. Considering the chamber volume and sample weight, the VC-P&T configuration was able to collect volatile substances more efficiently than the HT3. The VC-P&T-GC-MS system is believed to be useful for VOCs measurement of inhomogeneous large sample or devices used inside clean rooms.

A Case Study on the Release Characteristic and Removal Efficiency of Vinyl Chloride in the Poly Vinyl Chloride Extrusion Process (PVC압출공정의 염화비닐 발생특성과 작업환경개선에 관한 사례연구)

  • Park, Dong Uk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.3 no.1
    • /
    • pp.91-98
    • /
    • 1993
  • This study was carried out to investigate characteristic of vinyl chloride emissioned from poly vinyl chloride extrusion process and to evaluate the efficiency of local exhaust ventilation system. Before local ventilation facility was constructed in poly vinyl chloride extrusion process, the average worker exposure to vinyl chloride was 3.15 ppm, which exceeded Threshold Limit Value of American Conference of Gorvernmental Industrial Hygienists (ACGIH-TLV), 1 ppm. lt is possible that vinyl chloride residues in the poly vinyl chloride resin was released or degased due to extrusion heat. The larger the width of vinyl tube become, the higher worker exposure to vinyl chloride was. It is estimated that vinyl chloride from vinyl chloride resin increased as amount of poly vinyl chloride resin extruded in the extrusion process increased. Canopy hood was an appropriate type for poly vinyl chloride resin extrusion process. This local exhaust ventilation has fan static pressure of 7.65 inch wg($190mmH_2O$, total volumetric flowlate of 4,796 CFM ($135.8m^3$/min) and fan power requirement of 12 hp (8.952 Kw). After this local exhaust ventilation was constructed there, the average concentration of worker exposure to vinyl chloride was reduced to be 0.46 ppm, which was below the Threshold Limit Value, 1 ppm. Also, the removal efficiency rate of vinyl chloride attained by local exhaust ventilation was 85.3%. It was a statistically significant (p<0.01).

  • PDF

A Study on Composition of Solvent Thinners and Evaporation in the Air (일부 신나의 구성성분과 공기중 증발에 관한 연구)

  • Zoh, Kyung Ehi;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.245-263
    • /
    • 1997
  • For twelve solvent thinners, evaporation rates of components were investigated and models to estimate the actual concentration have been evaluated. Also, the current ACGIH TLVs (Threshold Limit Values) for the concentration of organic mixtures have been adjusted. The results of this study are summarized as follows : 1. Airborne concentrations of solvent thinner components were related to their respective vapor pressure (r=0.96). On the other hand, there was no significant relation between the concentrations in the air of the thinner compounds and the original amount in liquid form. 2. Airborne concentrations of each chemical were estimated by temperature at $8.5{\pm}1$, $16.7{\pm}1$ and $31.5{\pm}2^{\circ}C$ with an air velocity of 1.5 m/s. The concentrations were increased by increasing temperature (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl acetate, n-butyl alcohol, m-xylene, p-xylene and o-xylene showed a clear relationship to temperature. 3. Airborne concentration of each chemical was estimated by air velocity at 0.05, 1.50 and 2.50 m/s, with a constant temperature at $17{\pm}2^{\circ}C$. The concentrations were increased by increasing air velocity (p<0.05). The percentage of concentrations were proportionate to their respective percentage of vapor pressure. Among the chemicals studied, n-butyl alcohol, m-xylene and p-xylene showed a clear relationship to velocity. 4. In estimating the concentrations of solvent thinners by temperature and air velocity, ACGIH TLVs for mixtures tended to be larger than the values obtained by ACGIH exposure index. It shows that ACGIH TLVs for mixtures are not adequate for evaluating the airborne concentration of thinners and other organic mixtures. 5. The evaporation rate of the thinners were compared to the theoretical equations of Hummel, Braun and Mackay. The Hummel and Braun methods were close to exposure index but Makay's showed an underestimated value. In order to see the accuracy of each three models, the SSE (Error Sum of Squares) calculated for Hummel's was 1.73, being the closest to the actual values. 6. Present ACGIH TLVs for mixtures are not appropriate evaluate industrial environments. In this study, a correction of TLVs using vapor pressure of respective components was suggested. In order to evaluate the corrected TLVs a paired t-test was performed. There was no significant difference between the exposure index and the concentration over suggested TLVs (p>0.05). Thus, this corrected TLVs seem appropriate in order to evaluate actual industrial workplaces organic chemical concentration in the air.

  • PDF

Consolidation Behavior of Agricultural Reservoir under Embankment on Soft Ground (연약지반상(軟弱地盤上)에 축조(築造)된 농업용저수지(農業用貯水池) 제체의 압밀거동(壓密擧動))

  • Oh, Beom-Hwan;Lee, Dal-Won;Eam, Sung-Hoon
    • Korean Journal of Agricultural Science
    • /
    • v.29 no.2
    • /
    • pp.53-66
    • /
    • 2002
  • This study was performed to evaluation the consolidation behavior of agricultural reservoir in the very soft ground. The final settlement prediction methods by Terzaghi, Hyperbolic and Asaoka methods were used to compare with the degree of consolidation estimated by exess pore water pressure. The dissipated excess pore water pressure during embankment construction and peak excess pore water pressure on the completed embankment were suggested for the estimation of the degree of consolidation. It was concluded that the degree of consolidation estimated from dissipated excess pore water pressure was more reliable than that from the peak excess pore water pressure. The stability methods for agricultural reservoir was used to compare and analyze with various condition by limit equilibrium method.

  • PDF

The Influence of Abdominal Drawing-In Maneuver on Lumbar Lordosis and Trunk and Lower Extremity Muscle Activity During Bridging Exercise (교각운동 시 복부 드로잉-인 방법이 요부 전만과 체간 및 하지의 근 활성도에 미치는 영향)

  • Kim, Eun-Ok;Kim, Teck-Hoon;Roh, Jung-Suk;Cynn, Heon-Seock;Choi, Houng-Sik;Oh, Dong-Sik
    • Physical Therapy Korea
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 2009
  • An abdominal drawing-in maneuver (ADIM) with a pressure biofeedback unit can be used to prevent excessive lumbar lordosis during bridging exercise. Therefore, in this research, the effects of an ADIM on lumbar lordosis and lower extremity muscle activity during bridging exercise were investigated in thirty healthy adults. Surface electromyography (EMG) and VICON system were used to collect kinematic data and muscle activity, respectively. A paired t-test was used to determine a statistical significance. The results showed as follows: (1) When performing bridging exercise with an ADIM, the height of the anterior superior iliac spine and greater trochanter decreased significantly (p<.05). (2) When performing bridging exercise with an ADIM, the trunk extension angle and pelvic angle increased significantly (p<.05). (3) When performing bridging exercise with an ADIM, the EMG signal amplitude increased significantly in the rectus abdominis, internal oblique abdominis, external oblique abdominis, medial hamstring, and lateral hamstring (p<.05). (4) When performing bridging exercise with an ADIM, the EMG signal amplitude decreased significantly in the erector spinae (p<.05). From the result of this research, an ADIM trained with pressure biofeedback unit during bridging exercise is effective to prevent excessive contraction of erector spinae, to limit excessive motion of pelvis from sagittal plane and to increase muscle activity of abdominal muscles and hamstring muscle.

  • PDF

A Study on the Field Application of Automatic Grouting System (자동화 그라우팅 기법의 현장적용성에 관한 연구)

  • Do, Jongnam;Park, Junghwan;Choi, Dongchan;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.13 no.1
    • /
    • pp.63-74
    • /
    • 2012
  • In Korea, grouting has been mostly designed and constructed by experiences without expert knowledge and theoretical study. So there are a lot of problems related to the quality and safty of grouting. Therefor, in this paper the quality management skills and method were discussed through out by using the auto-grouting method and field test of grouting for the construction. Through the limit water injection test of the soil, it make the optimum injection pressure and injection speed of grouting, and through the lugeon test of the rock, it make assess the permeability of before and after grouting. In order to prevent the hydraulic fracture of soil and break away from the grouts if it apply four kinds of mode of grouting stop criteria, injection effects can be improved. From the above characteristcs designers evalute the fitness values of injection pressure(p), injection speed(q) and grouting penetration time(t). So far, to record and manage pressure(p) and speed(q) of grouting autographic devices such as intergation flow-meter usually record data in a roll of paper. Intergration flow-meter can record grouting flow quantity exactly, but the recorded pressures differ from the any basis such as intitial, intermediate and final point. Therefore, it has been argued that is a need of reliable method to describe the connection between the pressure recorded by an intergration flow-meter and the special properties of the grouting target ground. auto-grouting method can describe the reliable connection between the grouting pressure and the special properties of the grouting target ground. So, in this paper by using auto-grouting method, it is expected that to secure basis of quality control techniques construction.