• Title/Summary/Keyword: limit of detection

Search Result 2,401, Processing Time 0.031 seconds

Evaluation of Autochemical Analyzer Toshiba 120 FR (자동화학 분석기 Toshiba 120 FR의 평가)

  • Park, Jum Gi
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.98-109
    • /
    • 2004
  • The lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with another equipment was evaluated for the Toshiba-120FR chemistry autoanalyzer which was newly introduced at the Daejeon Veteran Hospital in Dec. 2003. Nineteen kinds of test for AST, ALT, ALP, LDH, GGT, TP, ALB, GLU, T-cho, T-bil, TG, UA, CAL, IP, AMY, HDL-C, LDL-C, Cre and BUN were performed to evaluate the lower limit of detection, precision, setting method of target value, reportable range determination, recovery, linearity, and comparison study with other equipment according to the NCCLS guidelines(EP5-A, EP6-P, EP9-A). The Toshiba-120FR autochemical analyzer showed good precision for all tested items. The data concerning the lower limit of detection, precision(total CV 0.47%~3.65%), setting method of target value, reportable range determination, recovery(93%~111%), linearity($R^2=0.997{\sim}0.999$), and comparison study(r=0.977~0.999) with other equipment was acceptable for all tested items. The results of evaluation for the Toshiba-120FR autochemical analyzer showed that this equipment could be used as an alternative to other equipment.

  • PDF

지하수의 라듐/라돈 동시측정을 위한 백그라운드 감마선 제어

  • Lee Gil-Yong;Yun Yun-Yeol;Jo Su-Yeong;Kim Yong-Je
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.308-311
    • /
    • 2005
  • [ $^{222}Rn\;and\;^{226}Ra$ ] in groundwater were determined simultaneously using a gamma-spectroscopy. A nitrogen flushing equipment has been used for elimination and stabilization of high and unstable background activity due to the radon and its progenies in counting shield and room. The aim of present work was to control the background activity for simultaneous measurement of radium$(^{226}Ra)$ and radon$(^{222}Rn)$ in groundwater using a gamma-spectrometry. Background activity was about 1.0dps and the standard deviation was about 50%, The background activity could be minimized using nitrogen flushing equipment in the range of 0.1 to 0.5 and the RSD was about 5% at the experimental condition. The detection limit of $^{222}Rn\;and\;^{226}Ra$ in groundwater was 0.5dps/L in the background control method. In most groundwater used in the work, radon activity was more than the detection limit. However, radium activity in some groundwater was less than the detection limit. If the low level radium in groundwater must be measured, preconcentration process such as concentration should be performed before measuring the groundwater.

  • PDF

Development of an ELISA for the Organophosphorus Insecticide Isofenphos

  • Park, Han-Jin;Park, Won-Chul;Jung, Tae-Owan;Rha, Choon-Sup;Lee, Yong-Tae
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.4
    • /
    • pp.599-603
    • /
    • 2002
  • A selective enzyme-linked immunosorbent assay (ELISA) for the insecticide isofenphos was developed. Three different analogues (haptens) of isofenphos were synthesized and were coupled to carrier proteins through the pesticide thiophosphate group t o use as immunogens or coating antigens. Rabbits were immunized with one of the haptens coupled to BSA for production of polyclonal antibodies and the sera were screened against each of the other two haptens coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigen-coated ELISA was developed, which showed an I50 of 96 ng/mL with the detection limit of 2 ng/mL. The antibodies showed negligible cross-reactivity with other organophosphorus pesticides and the phenol metabolite of isofenphos, which makes the developed assay suitable for the selective detection of isofenphos. An antibody-coated ELISA was also developed, which showed an I50 of 580 ng/mL with a detection limit of 70 ng/mL.

A study of neutron activation analysis compared to inductively coupled plasma atomic emission spectrometry for geological samples in Iran

  • Mohammadzadeh, Mohammad;Ajami, Mona;shadeghipanah, Arash;Rezvanifard, Mehdi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1349-1354
    • /
    • 2018
  • Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) is widely used for the determination of trace elements in geological samples in Iran. In this paper, we have calculated the detection limits of neutron activation analysis (NAA) for some of the common elements in such samples utilizing the ORIGEN and MCNP codes and verified the simulations using the experimental results of three soil standard reference materials, namely, G02.SRM, G18.SRM, and G28.SRM. The results show that while the detection limit of ICP-AES method is usually in the mg/kg range, it is represented to the ${\mu}g/kg$ range for most of the elements of interest using the NAA method, and the simulations can be verified in a tolerance range of 20%.

Development of SCAR Markers for the Identification of Phytophthora katsurae Causing Chestnut Ink Disease in Korea

  • Lee, Dong Hyeon;Lee, Sun Keun;Lee, Sang Yong;Lee, Jong Kyu
    • Mycobiology
    • /
    • v.41 no.2
    • /
    • pp.86-93
    • /
    • 2013
  • Sequence characterized amplified region (SCAR) markers are one of the most effective and accurate tools for microbial identification. In this study, we applied SCAR markers for the rapid and accurate detection of Phytophthora katsurae, the casual agent of chestnut ink disease in Korea. In this study, we developed seven SCAR markers specific to P. katsurae using random amplified polymorphic DNA (RAPD), and assessed the potential of the SCAR markers to serve as tools for identifying P. katsurae. Seven primer pairs (SOPC 1F/SOPC 1R, SOPC 1-1F/SOPC 1-1R, SOPC 3F/SOPC 3R, SOPC 4F/SOPC 4R, SOPC 4F/SOPC 4-1R, SOPD 9F/SOPD 9R, and SOPD 10F/SOPD 10R) from a sequence derived from RAPD fragments were designed for the analysis of the SCAR markers. To evaluate the specificity and sensitivity of the SCAR markers, the genomic DNA of P. katsurae was serially diluted 10-fold to final concentrations from 1 mg/mL to 1 pg/mL. The limit of detection using the SCAR markers ranged from $100{\mu}g/mL$ to 100 ng/mL. To identify the limit for detecting P. katsurae zoospores, each suspension of zoospores was serially diluted 10-fold to final concentrations from $10{\times}10^5$ to $10{\times}10^1$ zoospores/mL, and then extracted. The limit of detection by SCAR markers was approximately $10{\times}10^1$ zoospores/mL. PCR detection with SCAR markers was specific for P. katsurae, and did not produce any P. katsurae-specific PCR amplicons from 16 other Phytophthora species used as controls. This study shows that SCAR markers are a useful tool for the rapid and effective detection of P. katsurae.

Development of an ELISA for the Organophosphorus Insecticide Chlorpyrifos

  • Cho, Young Ae;Lee, Hye-Sung;Park, Eun-Yeong;Lee, Yong-Tae;Hammock, Bruce D.;Ahn, Ki-Chang;Lee, Jae-Koo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.3
    • /
    • pp.481-487
    • /
    • 2002
  • A selective enzyme-linked immunosorbent assay (ELISA) for the insecticide chlorpyrifos was developed. Four haptens for chlorpyrifos were synthesized and two of them were used as immunogens after coupling to keyhole limpet hemocyanin by two differe nt approaches. Rabbits were immunized with either of them and the sera were screened against 4 haptens coupled to ovalbumin (OVA). Using the sera of highest specificity, an antigencoated ELISA was developed, which shows an I50 of 160 ppb with a detection limit of 10 ppb. An antibody-coated ELISA was also developed, which shows an $I_{50}$ of 20 ppb with a detection limit of 0.1 ppb. The antibodies showed negligible cross-reactivity with other organophosphorus pesticides except for insecticides chlorpyrifos-methyl and bromophos-ethyl, which makes these assays suitable for the selective detection of chlorpyrifos.

Improved Detection of Multi-phosphorylated Peptides by LC-MS/MS without Phosphopeptide Enrichment

  • Kim, Suwha;Choi, Hyunwoo;Park, Zee-Yong
    • Molecules and Cells
    • /
    • v.23 no.3
    • /
    • pp.340-348
    • /
    • 2007
  • Although considerable effort has been devoted in the mass spectrometric analysis of phosphorylated peptides, successful identification of multi-phosphorylated peptides in enzymatically digested protein samples still remains challenging. The ionization behavior of multi-phosphorylated peptides appears to be somewhat different from that of mono- or di-phosphorylated peptides. In this study, we demonstrate increased sensitivity of detection of multi-phosphorylated peptides of beta casein without using phosphopeptide enrichment techniques. Proteinase K digestion alone increased the detection limit of beta casein multi-phosphorylated peptides in the LC-MS analysis almost 500 fold, compared to conventional trypsin digestion (~50 pmol). In order to understand this effect, various factors affecting the ionization of phosphopeptides were investigated. Unlike ionizations of phosphopeptides with minor modifications, those of multi-phosphorylated peptides appeared to be subject to effects such as selectively suppressed ionization by more ionizable peptides and decreased ionization efficiency by multi-phosphorylation. The enhanced detection limit of multi-phosphorylated peptides resulting from proteinase K digestion was validated using a complex protein sample, namely a lysate of HEK 293 cells. Compared to trypsin digestion, the numbers of phosphopeptides identified and modification sites per peptide were noticeably increased by proteinase K digestion. Non-specific proteases such as proteinase K and elastase have been used in the past to increase detection of phosphorylation sites but the effectiveness of proteinase K digestion for multi-phosphorylated peptides has not been reported.

Electrochemical Detection of Trace Level Copper in in vivo Cell (생체 세포내 미량 구리의 전기화학적 검출에 관한 연구)

  • Lee, Chang-Hyun
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1333-1338
    • /
    • 2012
  • In order to measure the minute amount of Cu(II) in our environment, cyclic voltammetry (CV) and square-wave stripping voltammetry (SWSV) were performed for a trace copper assay using bismuth immobilized on a carbon nanotube paste electrode. An analytical working range of 30 to $240{\mu}g/L$ Cu(II) was obtained for CV and SWSV. The SWSV precision obtained was 0.47 % (n = 15) RSD in $30.0{\mu}g/L$ Cu(II). The detection limit obtained was 3.1 ng/L Cu(II) using SWSV, while the CV yielded the nano-range detection limit through the pre-concentration step. By using this research method, Cu(II) value could be determined in the urine of human sample and in the brain of fish sample. This research can be effectively applied to other cases of measuring minute amount of Cu(II) in living organisms.

Microfluidic immunoassay using superparamagnetic nanoparticles in an enhanced magnetic field gradient (강화된 자기장 구배 하에서 나노자성입자를 이용한 미세유체 기반의 면역 측정)

  • Hahn, Young-Ki;Kang, Joo-H.;Kim, Kyu-Sung;Park, Je-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.158-163
    • /
    • 2006
  • This paper reports a novel immunoassay method using superparamagnetic nanoparticles and an enhanced magnetic field gradient for the detection of protein in a microfluidic device. We use superparamagnetic nanoparticles as a label and fluorescent polystyrene beads as a solid support. Based on this platform, magnetic force-based microfluidic immunoassay is successfully applied to analyze the concentration of IgG as model analytes. In addition, we present ferromagnetic microstructure connected with a permanent magnet to increase magnetic flux density gradient (dB/dx, ${\sim}10^{4}$ T/m), which makes limit of detection reduced. The detection limit is reduced to about 1 pg/mL.

Power Quality Early Warning Based on Anomaly Detection

  • Gu, Wei;Bai, Jingjing;Yuan, Xiaodong;Zhang, Shuai;Wang, Yuankai
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1171-1181
    • /
    • 2014
  • Different power quality (PQ) disturbance sources can have major impacts on the power supply grid. This study proposes, for the first time, an early warning approach to identifying PQ problems and providing early warning prompts based on the monitored data of PQ disturbance sources. To establish a steady-state power quality early warning index system, the characteristics of PQ disturbance sources are analyzed and summed up. The higher order statistics anomaly detection (HOSAD) algorithm, based on skewness and kurtosis, and hierarchical power quality early warning flow, were then used to mine limit-exceeding and abnormal data and analyze their severity. Cases studies show that the proposed approach is effective and feasible, and that it is possible to provide timely power quality early warnings for limit-exceeding and abnormal data.