• 제목/요약/키워드: limit in distribution

Search Result 1,129, Processing Time 0.038 seconds

A Study on the Voltage Stabilization Method of Distribution System Using Battery Energy Storage System and Step Voltage Regulator

  • Kim, Byung-ki;Park, Jae-Beom;Choi, Sung-Sik;Jang, Moon-Seok;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.11-18
    • /
    • 2017
  • In order to maintain customer voltages within the allowable limit($220{\pm}13V$) as much as possible, tap operation strategy of SVR(Step Voltage Regulator) which is located in primary feeder, is widely used for voltage control in the utilities. However, SVR in nature has operation characteristic of the delay time ranging from 30 to 150 sec, and then the compensation of BESS (Battery Energy Storage System) during the delay time is being required because the customer voltages in distribution system may violate the allowable limit during the delay time of SVR. Furthermore, interconnection of PV(Photovoltaic) system could make a difficultly to keep customer voltage within the allowable limit. Therefore, this paper presents an optimal coordination operation algorithm between BESS and SVR based on a conventional LDC (Line Drop Compensation) method which is decided by stochastic approach. Through the modeling of SVR and BESS using the PSCAD/EMTDC, it is confirmed that customer voltages in distribution system can be maintained within the allowable limit.

Weavability Limit of Yarns with Thickness Variation in Shuttleless Weaving

  • Seyam, Abdelfattah M.
    • Fibers and Polymers
    • /
    • 제4권4호
    • /
    • pp.176-181
    • /
    • 2003
  • Theoretical weavability limit relationships of fabrics from regular warp yarns and fancy filling yams with thickness variation in shuttleless weaving are reviewed. The relationships correlate maximum warp and filling cover factors, warp and filling yarn characteristics, the distribution of thick and thin places of filling yarn over the fabric surface, and the warp and filling weave factor. The research considers single filling feeder and multiple feeders cases. Additionally, comparisons between the weavability limit of regular yarns and fancy yams in shuttle and shuttleless weaving are given.

비정규 공정의 극소 불량률 관리를 위한 Zp 관리도 적용 방안 연구 (On the Application of Zp Control Charts for Very Small Fraction of Nonconforming under Non-normal Process)

  • 김종걸;최성원;김혜미;엄상준
    • 품질경영학회지
    • /
    • 제44권1호
    • /
    • pp.167-180
    • /
    • 2016
  • Purpose: The problem for the traditional control chart is that it is unable to monitor the very small fraction of nonconforming and the underlying distribution is the normal distribution. $Z_p$ control chart is useful where it controls the vert small fraction on nonconforming. In this study, we will design the $Z_p$ control chart in order to use under non-normal process. Methods: $Z_p$ is calculated not by failure rate based on attribute data but using variable data. Control limit for non-normal $Z_p$ control chart is designed based on ${\alpha}$-risk calculated by cumulative distribution function of Burr distribution. ${\beta}$-risk, which is for performance evaluation, obtains in the Burr distribution's cumulative distribution function and control limit. Results: The control limit for non-normal $Z_p$ control chart is designed based on Burr distribution. The sensitivity can be checked through ARL table and OC curve. Conclusion: Non-normal $Z_p$ control chart is able to control not only the very small fraction of nonconforming, but it is also useful when $Z_p$ distribution is non-normal distribution.

ON THE WEAK LIMIT THEOREMS FOR GEOMETRIC SUMMATIONS OF INDEPENDENT RANDOM VARIABLES TOGETHER WITH CONVERGENCE RATES TO ASYMMETRIC LAPLACE DISTRIBUTIONS

  • Hung, Tran Loc
    • 대한수학회보
    • /
    • 제58권6호
    • /
    • pp.1419-1443
    • /
    • 2021
  • The asymmetric Laplace distribution arises as a limiting distribution of geometric summations of independent and identically distributed random variables with finite second moments. The main purpose of this paper is to study the weak limit theorems for geometric summations of independent (not necessarily identically distributed) random variables together with convergence rates to asymmetric Laplace distributions. Using Trotter-operator method, the orders of approximations of the distributions of geometric summations by the asymmetric Laplace distributions are established in term of the "large-𝒪" and "small-o" approximation estimates. The obtained results are extensions of some known ones.

배전계통에서의 분산전원 도입운용 관리방법 : LDC 운전을 하지 않을 경우 (A Control Method of Distributed Generation System Which is Connected to Power Distribution System : Without LDC Operation)

  • 정원재;김태응;김재언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.231-233
    • /
    • 2001
  • Nowadays, small scale DGS(Distributed Generation System), as a wind power generation or photovoltaic generation, becomes to be introduced into the power distribution system. But in that case, it is difficult to properly maintain the terminal voltage of low voltage customers. So, it is necessary to determine the permissible operation limit of the introduced DGS for proper voltage in distribution system. In this paper computes permissible operation limit of DGS when the DGS is connected to power distribution system using fixed tap(without LDC operation). For this simulation, KEPCO distribution system is used.

  • PDF

Factor of safety in limit analysis of slopes

  • Florkiewicz, Antoni;Kubzdela, Albert
    • Geomechanics and Engineering
    • /
    • 제5권5호
    • /
    • pp.485-497
    • /
    • 2013
  • The factor of safety is the most common measure of the safety margin for slopes. When the traditionally defined factor is used in kinematic approach of limit analysis, calculations can become elaborate, and iterative methods have to be used. To avoid this inconvenience, the safety factor was defined in terms of the work rates that are part of the work balance equation used in limit analysis. It was demonstrated for two simple slopes that the safety factors calculated according to the new definition fall close to those calculated using the traditional definition. Statistical analysis was carried out to find out whether, given normal distribution of the strength parameters, the distribution of the safety factor can be approximated with a well-defined probability density function. Knowing this function would make it convenient to calculate the probability of failure. The results indicated that the normal distribution could be used for low internal friction angle (up to about $16^{\circ}$) and the Johnson distribution could be used for larger angles ${\phi}$. The data limited to two simple slopes, however, does not allow assuming these distributions a priori for other slopes.

수질오염총량관리를 위한 환경기초시설 배출수질의 통계적 평가방법 개선 : 선형보간법의 백분위수방법 (Implementation of the Calculation Method for 95% Upper Limit of Effluent Water Quality of Sewage Treatment Plant for Total Maximum Daily Loads : Percentile Ranking Method)

  • 박재홍;김동우;오승영;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제24권6호
    • /
    • pp.676-681
    • /
    • 2008
  • The evaluation of the effluent water quality of sewage treatment plant is one of the most important factor in calculating total maximum daily loads (TMDLs). Current method to calculate 95% upper limit of effluent water quality of sewage treatment plant assuming normal distribution of data needs to be implemented in case of non-normal distribution. We have investigated the applicability of percentile ranking method as a non-parametric statistical analysis in case of non-normal distribution of data.

The Limit Distribution and Power of a Test for Bivariate Normality

  • Kim, Namhyun
    • Communications for Statistical Applications and Methods
    • /
    • 제9권1호
    • /
    • pp.187-196
    • /
    • 2002
  • Testing for normality has always been a center of practical and theoretical interest in statistical research. In this paper a test statistic for bivariate normality is proposed. The underlying idea is to investigate all the possible linear combinations that reduce to the standard normal distribution under the null hypothesis and compare the order statistics of them with the theoretical normal quantiles. The suggested statistic is invariant with respect to nonsingular matrix multiplication and vector addition. We show that the limit distribution of an approximation to the suggested statistic is represented as the supremum over an index set of the integral of a suitable Gaussian Process. We also simulate the null distribution of the statistic and give some critical values of the distribution and power results.

A Simple Chi-squared Test of Multivariate Normality Based on the Spherical Data

  • Park, Cheolyong
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.117-126
    • /
    • 2001
  • We provide a simple chi-squared test of multivariate normality based on rectangular cells on the spherical data. This test is simple since it is a direct extension of the univariate chi-squared test to multivariate case and the expected cell counts are easily computed. We derive the limiting distribution of the chi-squared statistic via the conditional limit theorems. We study the accuracy in finite samples of the limiting distribution and then compare the poser of our test with those of other popular tests in an application to a real data.

  • PDF

IT기반 분산전원 연계 배전계통의 최적전압조정에 관한 연구 (A study for IT Based Optimal Voltage Control Method of Distribution Systems with Distributed Generation)

  • 김정년;백영식;서규석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권4호
    • /
    • pp.139-143
    • /
    • 2006
  • Recently, standard of living improved and Information-Communication industry developed rapidly. Thereby, interest about electric power quality is rising worldwide. So, research and Development to enhance electric power quality in various viewpoint until most suitable supply system from each kind device to improve electric power quality. And specially, interest about voltage quality is rising by diffusion increase of information communication appliance and minuteness control appliance etc. Also Power consumption is increasing, but expansion of large size generator by environmental and site security problem is difficult. So, introduction of distribution generation is investigated actively by electric-power industry reorganization. Voltage management of power system had been controlled by ULTC (Under Load Tap Changer) in substation and pole transformer on the high voltage distribution line. But, voltage control device on substation and distribution line is applied each other separatively. Therefore, efficiency of line voltage control equipment is dropping. Also, research about introduction upper limit of distribution generation is consisting continuously. This paper presents cooperation use way between voltage control device and introduction upper limit of distribution generation for most suitable voltage control in distribution power system.