• 제목/요약/키워드: lighting pole

검색결과 15건 처리시간 0.018초

도로조명 방식이 운전자 시지각에 미치는 영향 (Effectiveness of Road Lighting on Driver' Vision)

  • 정준화;이석기;김원식;이미애
    • 한국도로학회논문집
    • /
    • 제14권4호
    • /
    • pp.125-131
    • /
    • 2012
  • PURPOSES : Road lighting facilities increase the visibility of road at night in order to improve traffic driver safety and comfort. Generally speaking, current pole lighting has a tendency to create problems of glare and flicker. The phenomenon of glare gives discomfort due to increase of scattered light, when high luminance is in driver's field of view. The phenomenon of flicker occurs due to the driver passing through discontinuous pockets of pole lighting areas. These phenomenon increase eye strain and decrease driver safety. METHODS : Low height line lighting that distributes light lower than driver's eye level has been developed and evaluated to reduce the problems linked to current pole lighting. A test was undertaken with 4 conditions(turn on the general pole lighting, turn off alternate pole lighting, turn on the line lighting and line lighting with 50% dimming). A driver written survey was conducted in order to gain driver feedback. RESULTS : Pupil size and brow frequency compared with degree in pole lighting are reduced. CONCLUSIONS : Low height line lighting environment makes drivers more comfortable than pole lighting environment and is positive lighting method in the energy saving and landscape aspect.

리브보강 Al-Mg-Si계 가로등 등주의 구조적 거동 (Structural Behavior of Rib Reinforced Mg-Si Aluminum Alloy lighting Pole)

  • 남정훈;주형중;김영호;윤순종
    • Composites Research
    • /
    • 제21권6호
    • /
    • pp.8-14
    • /
    • 2008
  • 가로등은 운전자의 안전을 위한 필수적인 도로 부속구조물이며, 대부분 강재 등주를 사용하고 있다. 강재등주는 부식이 발생하여 내구성을 감소시키고, 도시미관을 저해하므로 스테인레스 제품이나 주철재 등을 사용하기도 한다. 그러나 주철재 및 스테인레스 등주를 사용하더라도 부식에 대한 위험성을 완전히 배제할 수 없고, 높은 강도와 강성은 충돌시 운전자의 안전을 위협하는 요인이 되고 있다. 따라서 새로운 형태의 등주 시스템의 개발이 요구되고 있다. 기존 등주의 문제점을 보완하기 위해 최근 알루미늄 합금을 사용한 등주가 개발되어 사용되고 있다. 알루미늄은 재료적 특성상 단위중량당 강도가 높고 부식에 대한 저항성이 매우 커서 그 활용성을 크게 증대될 것으로 예측되나 강계에 비해 강성과 강도가 낮기 때문에 구조적 안전성에서 문제점이 제기되고 있어 구조거동에 대한 연구가 필요하다. 이 연구는 현재 가로등 등주로 사용되고 있는 강재 및 알루미늄 등주에 대한 휨, 압축실험 등을 수행하여 알루미늄 등주의 구조거동을 조사하였고, 기존 강재등주와 비교하여 효율성 및 안전성을 평가하였다.

A Study on Development Direction of Smart Pole for Smart City Construction

  • Kim, Tae Yeun;Bae, Sang Hyun
    • 통합자연과학논문집
    • /
    • 제12권1호
    • /
    • pp.1-8
    • /
    • 2019
  • Smart pole is one of mega trend in smart city development. It has multi-function to get as much as data from the street to better city management. And smart street lighting of smart pole as core part of smart city development is being implemented by many cities in globally. Refer to the latest edition of Navigant Research's Smart City Tracker includes smart city projects in 221 cities, a quarter of which are deploying smart street lighting ranging from initial pilots to citywide and regional deployments that span tens and even hundreds of thousands of lights. The most important feature of smart street lighting solution is "Connectivity" through the IoT technology. In order to implement the smart city, we should have so-called intelligent watchdog and mesh networked post for keeping the various smart city technology development progress and operation properly. Smart street lighting solution could be main infrastructure as an enabler for a range of smart city applications. We can talk about the expected role of smart street lighting for the smart city development on this paper.

악천후 시 낮은 도로조명을 이용한 도로 시인성 향상에 대한 연구 (A Research on the Improvement of Visibility Using Low Deck Lighting in Bad Weather)

  • 남기호;김충혁;최운식
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.186-193
    • /
    • 2020
  • We investigate a fog-detection CCT control system using low deck lighting as a solution to the forward visibility of pole-type street lamps employed on existing roads. The lighting standards were met with a light source that has less compared with those of pole-type street lamps. The results show that the transmission rate was increased by changing the color temperature by automatically recognizing fog in bad weather and minimizing the phenomenon of lighting. In addition, it was allowed to create a safer and more comfortable driving environment for drivers owing to flicker or light pollution of existing pole-type street lamps. As a result, if lighting is used at a lower level than pole-type street lamps, the accident rate caused by securing the driver's forward visibility can be reduced sharply and existing problems can be resolved.

가로등의 전기설비 현장실태조사 (On-site Survey of the Street Lighting Facilities)

  • 김한상;배석명;김종민
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.426-431
    • /
    • 2006
  • The case where a drain cannot flow backwards, a sewer institution can be unmanageable in this, and a mad is under water momentarily by local heavy nin by the climate phenomenon in spite of not being a lowlands belt has occurred well more than recently. By the flooded mea since it is in the state which has some human bodies at hand, when a short circuit occurs in street lighting pole which is the electric institution thing of a road, the danger of an electric shock accident becomes higher. In this paper, it was going to show improvement plan for grasping the brittle factor of street lighting pole electricity facilities through the on-site survey of street lighting pole electricity facilities, and improving this.

  • PDF

혼합 배전선로에 직격낙뢰시 전주와 케이블직선접속재가 케이블 동심중성선 전위상승에 미치는 영향 (A Study of Concentric-Neutral Line Voltage Increase Related by Pole and Cable Joint When Lightening Overvoltage Injected in Combined Distribution Line)

  • 전용주;전명수
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.702-707
    • /
    • 2018
  • In case of Lighting occurs in Domestic combined distribution line, normally the voltage for the neutral line increase dramatically. General connection for underground cable is bundled common earth type so the lightning over voltage increase at the concentric-neutral line is not big enough to give impact on cable sheath. But in case of Non bundled common earth type it is necessary to analyze the phenomena on cable sheath caused by lightening overvoltage. Especially pole and cable joint are the core factor to consider. In this paper concrete pole and cable joint were evaluated in case of Non bundled common earth type combined distribution Line. EMTP simulation model has been designed and several case study were made. Also several experimental test were made to verify the simulation result.

Cnopy가 없는 경기장의 스포츠 조명 4, 8Pole 배치에 따른 조도분포 비교 (A Comparative of Illumination Distribution according to the Arrangement of Sports Lighting 4 and 8 Pole in the Noncanopy Stadium)

  • 박식;고석철;임성훈;윤기웅;이종화;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1224-1226
    • /
    • 2003
  • 본 연구에서는 canopy가 없는 stadium에서의 야간조명 실태를 조사하고 국내에 설치된 각 stadium의 조도를 측정하여 그 결과를 KS, FIFA기준 및 방송국 기준을 비교하고 stadium의 전체적인 조도분포를 분석하였다. 4pole 배치의 stadium에 있어서 조도는 KS 기준에는 대체로 만족하나 FIFA 및 방송국 기준에는 미흡함을 알 수 있었다. 특히 4pole 배치 방식에 있어서 수평면 및 수직면 조도의 균일도는 국제기준에 많이 미흡하여 원활한 경기진행 및 TV 중계에 많은 어려움이 있었다. 이러한 결과로부터 stadium의 조명시설을 고려한 설계과정의 필요함을 알 수 있었고, 또한 KS기준이 국제기준과 비교하여 많은 차이가 있어 stadium의 특성을 고려한 제도적인 보완을 통하여 철저한 설계가 이루어져야 하겠다.

  • PDF

가로등 POLE 설치간격에 적용되는 인도용 조명기구 반사판의 설계 (Design of the pedestrian lighting reflector it is installed to the spacing of existing street lighting)

  • 정승균;조숙현;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.175-177
    • /
    • 2008
  • 본 논문에서는 개정된 KS 기준을 만족하면서 새로이 인도 조명기구용 pole을 설치할 필요 없이 기존의 가로등 pole에 바로 적용할 수 있는 높이가 낮은 인도용 조명기구용 반사판의 설계를 실행하고 광학 성능 예측 프로그램을 사용하여 그 성능을 확인하였다. 또한 설계는 신광원에 관심이 집중되고 있는 현재 추세에 맞추어 콤팩트 메탈할라이드 램프를 적용하여 실행하고 조명기구 반사판의 소형화 및 고성능화를 이끌어 낼 수 있도록 하였다.

  • PDF

주거지역에서 가로조명에 의한 침입광발생 분석 (A Field Investigation on Light Trespass of Residential Buildings by Street Lighting)

  • 하나;김정태
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.71-78
    • /
    • 2010
  • Spill light by street lighting is a kind of light pollution creating cozy night atmosphere, interfere visual private and cause insomnia at night. This study was to survey light trespass of the windows in residential buildings. According to outdoor lighting control guidance in Seoul, three different areas were selected to investigate the trespass light to windows. The results were as follows: 37% of the buildings of 386 buildings were influenced by street lighting, and 47% of windows were occurred light trespass. Therefore, the street lighting affected light trespass at night in survey area. The main reasons of light trespass were luminaire type, luminaire pole height, and street width. For protecting the light trespass to windows, it is necessary to non-cutoff fixture to full cutoff fixture by the street width.

등주식 조명과 낮은 조명의 성능 비교에 관한 연구 (A Comparative Study on Visibility Performance Between Pole Type Lightings and Low-Level Lightings)

  • 박원일;이석기;진민수;김용석
    • 한국ITS학회 논문지
    • /
    • 제17권6호
    • /
    • pp.185-201
    • /
    • 2018
  • 야간 도로를 주행하는 운전자의 안전을 위한 대표적인 대책으로 등주식 도로조명의 설치가 선호되고 있다. 그러나 기존 등주식 형태 도로조명의 경우 노면으로부터 일정 높이에 설치되는 특성으로 인해 광원이 운전자에게 직접적으로 강한 눈부심을 주어 운전자의 시인성을 저해하고, 도로 외의 지역에도 빛이 누설되어 에너지 효율이 떨어질 뿐 아니라 주거지역이나 동식물에 장해를 주는 빛공해가 발생하게 된다. 이러한 문제점을 해소한 낮은 위치에 설치되어 조명이 도로만을 비추는 형태의 낮은 조명이 해결책으로 제안되고 있으나, 도입 초기인 낮은 조명이 도로조명등급을 만족하여 도로조명으로서의 역할을 할 수 있는지에 대한 연구는 부족한 실정이다. 따라서 본 연구는 도로조명으로서 요구되는 최소한의 시인성능 기준을 만족함과 동시에 빛공해를 근본적으로 차단할 수 있는 구조의 낮은 조명을 개발하고 기존 등주식 조명과 시인성능 비교를 수행한 결과를 제시하였다. 비교결과, 기존 등주식 조명에 비해 평균노면휘도, 균제도, 임계치 증분 평가에서 우수한 결과를 나타냈다.