• Title/Summary/Keyword: light sensitivity

Search Result 614, Processing Time 0.024 seconds

Verification of Reduced Order Modeling based Uncertainty/Sensitivity Estimator (ROMUSE)

  • Khuwaileh, Bassam;Williams, Brian;Turinsky, Paul;Hartanto, Donny
    • Nuclear Engineering and Technology
    • /
    • v.51 no.4
    • /
    • pp.968-976
    • /
    • 2019
  • This paper presents a number of verification case studies for a recently developed sensitivity/uncertainty code package. The code package, ROMUSE (Reduced Order Modeling based Uncertainty/Sensitivity Estimator) is an effort to provide an analysis tool to be used in conjunction with reactor core simulators, in particular the Virtual Environment for Reactor Applications (VERA) core simulator. ROMUSE has been written in C++ and is currently capable of performing various types of parameter perturbations and associated sensitivity analysis, uncertainty quantification, surrogate model construction and subspace analysis. The current version 2.0 has the capability to interface with the Design Analysis Kit for Optimization and Terascale Applications (DAKOTA) code, which gives ROMUSE access to the various algorithms implemented within DAKOTA, most importantly model calibration. The verification study is performed via two basic problems and two reactor physics models. The first problem is used to verify the ROMUSE single physics gradient-based range finding algorithm capability using an abstract quadratic model. The second problem is the Brusselator problem, which is a coupled problem representative of multi-physics problems. This problem is used to test the capability of constructing surrogates via ROMUSE-DAKOTA. Finally, light water reactor pin cell and sodium-cooled fast reactor fuel assembly problems are simulated via SCALE 6.1 to test ROMUSE capability for uncertainty quantification and sensitivity analysis purposes.

Evaluation of the wear of the periodontal curet's cutting edge (치주 큐렛의 절단 연 마모도 평가)

  • Park, Eung-Joon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.575-584
    • /
    • 1997
  • The quality of periodontal instrument cutting edge is a basic element of effective root planing procedure. Using instruments, the sharp edge is changed into blunt or beveled edge. With the blunt instrument, the periodontal treatment can't be carried into accuracy and effective. The study on the wear of periodontal curet is insufficient, there are few publications about the change of sharpness of cutting egde after using instrument and a certen reports were published on the study of scanning electron microscope(SEM) examination. In this study, to declare the number of strokes for sharpening of instruments, the changes of cutting edge is measured by the clinical methods, tactile sensitivity examination and refraction light-white line test after scaling strokes and root planing strokes. SEM test was added for defined the changes of cutting edges. The 7/8 Gracey curets that have been never used was tested. Maxillary molars which were extracted from the School of Dental Medicine, Dankook University was used. Subjected teeth had attachment loss more than 6 mm in bucca-lingual surface and sufficient calculus of a band type in cervical area. The strokes of curet were executed 3, 5, 7, 9, 11, 13 times on scaling stroke and 10, 15, 20, 25, 30, 35 times on root planing stroke. A resident has periodontal experience over 3 years carried out the clinical examinations those tactile sensitivity examination and refraction light-white line test 5 times. The case there being tactile sensitivity certenly is 2, the case being felt tactile sensitivity is 1, and the case there not being tactile sensitivity is 0. The visual examination was recorded as following. The case that refracted white line is not recognised is 2, the case that uncerten is 1, and the case that acknowledged is 0. The results were obtained as follows. 1. After scaling strokes, the tactile sensitivity was reduced after 11 strokes and disappeared in 13 strokes. 2. In tactile sensitivity after root planing procedures, sensitivity was reduced after 25 strokes and disappeared in 35 strokes. 3. In case of visual examination, the detection of refracted white line was increased after 9 strokes of scaling procedures and the accuracy of wear wasn't showed after root planing procedures. 4. In SEM, metal projection was observed on new periodontal curet cutting edge and it was disappeared after scaling procedures. 5. In SEM, the cutting edge was showed changing linear into an aspect of the surface after 5 strokes of scaling procedures and 10 strokes of root planing procedures and showed beveled edge in 11 strokes of scaling procedures, 25 strokes of root planing procedures. The results of 3-type examination indicated that the sharpening of curet should be performed after 11 strokes of scaling procedures and 25 strokes of root planing procedures.

  • PDF

Improving light collection efficiency using partitioned light guide on pixelated scintillator-based γ-ray imager

  • Hyeon, Suyeon;Hammig, Mark;Jeong, Manhee
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1760-1768
    • /
    • 2022
  • When gamma-camera sensor modules, which are key components of radiation imagers, are derived from the coupling between scintillators and photosensors, the light collection efficiency is an important factor in determining the effectiveness with which the instrument can identify nuclides via their derived gamma-ray spectra. If the pixel area of the scintillator is larger than the pixel area of the photosensor, light loss and cross-talk between pixels of the photosensor can result in information loss, thereby degrading the precision of the energy estimate and the accuracy of the position-of-interaction determination derived from each active pixel in a coded-aperture based gamma camera. Here we present two methods to overcome the information loss associated with the loss of photons created by scintillation pixels that are coupled to an associated silicon photomultiplier pixel. Specifically, we detail the use of either: (1) light guides, or (2) scintillation pixel areas that match the area of the SiPM pixel. Compared with scintillator/SiPM couplings that have slightly mismatched intercept areas, the experimental results show that both methods substantially improve both the energy and spatial resolution by increasing light collection efficiency, but in terms of the image sensitivity and image quality, only slight improvements are accrued.

A Study on the Optimum Structural Components of the Rural House Using the Light Gage Cold-Formed Steel Frame (경량형강을 이용한 농촌주택의 최적 구조요소 선정에 관한 연구)

  • 정남수;이정재
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.167-170
    • /
    • 1998
  • In this study, the optimum structural components of the rural house using the light gage cold-formed steel frame is proposed. The model for selecting the optimum structural components, determines the range of load by the region and size of house, calculates the weight of the component by structural design process and optimizes a kind of the component by sensitivity analysis of the component to the total weight.

  • PDF

Study on Photochromism for Transition Metal Compounds by Using the Optieal Waveguide (광 도파관을 이용한 전이금속 화합물의 광색성연구)

  • SeeWooLee
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.10 no.1
    • /
    • pp.1-13
    • /
    • 1992
  • The recent results concerning the synthesis and application of spiroxazine dyes have been summerized., The absorption bands of usual spiroxazine dyes are changed from colorless to colored from by irradiation of ultraviolet ray. This mechanism is derived from the cleavage of oxazine ring. Such properties are dependent on its chemical structure and surrounded matrix of spiroxazine dyes. the chemical structure of this dye is similar to the well known spriopyran. But spiroxazine dyes have noticed recently, because of excellent high light-sensitivity and superior fatigue-resistant property. This dye are already applied as photochromic lens, cloths and UV light checker.

  • PDF

Studies on Photosensitive Polymers (X). Studies on Photosensitivity and Spectral Sensitivity of Naphthoquinone-1,2-diazide-5-sulfonyl Esters (感光性 樹脂에 關한 硏究 (第10報). Naphthoquinone-1,2-diazide-5-sulfonyl Esters의 感光性과 分光感度)

  • Shim Jyong Sup;Kang Doo Whan
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.4
    • /
    • pp.269-279
    • /
    • 1975
  • Photosensitive properties of naphthoquinone-1,2-diazide-5-sulfonyl esters (PGND, BEND and PVAND) of polyglyceryl phthalate(PG), bisphenol A-epichlorohydrin condensate(BE) and polyvinyl alcohol(PVA) were investigated by the change of solubility before and after exposing to light. Various samples coated on glass or quartz plates were exposed to light under various conditions and steeped in aqueous alkali solution, and then the yield of residual film(W/W0) was determined. The yield of residual film, which was closely related to the sensitivity of the film, was affected by the degree of polymerization of the backbone resin, sensitizers and their concentration. In polymer homologs, the sensitivity was dependent on the degree of polymerization(the higher, the better). And also, it was most effective when 5 % of sensitizers to esters was used. The minimum exposed time was 0.6 min. for PGND-1, 1.0 min. for BEND-1, and 3.0 min. for PVAND-1. Most effective sensitizers for PGND, BEND and PVAND among those used here were benzanthrone, 5-nitroacenaphthene and picramide, respectively. The spectral sensitivities of PGND, BEND and PVAND were examined by comparing their spectrograms with UV-spectra in a solid state. Also, the sensitization and spectral sensitivity of the above polymers were studied. All the polymers containing the sensitizers showed optical sensitization. From the fact that in either case of sensitized or unsensitized sample, the ranges of absorption-maximum wave length were almost consistent with sensitivity maximum wave length, it was proved that the light absorbed by a sample served efficiently for photochemical reactions. Benzanthrone was found to be an excellent sensitizer for PGND.

  • PDF

A Study on Electron Emission Characteristics of Photocathode Formed Under Condition in N2 Atmosphere (상압에서 제조한 포토캐소드의 전자방출 특성에 관한 연구)

  • Jeong, Hyo-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.5
    • /
    • pp.312-316
    • /
    • 2014
  • Photoemission is a process in which photons are converted into free electrons. Photocathodes are the typical materials for the process. They emit electrons when a light is irradiated upon. The traditional method of manufacturing photocathodes is complicated, requires specialized equipment, and is limited very small sized samples. $Cs_3Sb$ photocathode was formed on a substrate in $N_2$ atmospheric conditions. The photocathode formation was a gas phase reaction with the substrate. Vacuum devices were made to test electron emission characteristics of the formed photocathode. Visible light of wavelength 475 nm was used for the primary light source. The results showed high current density and long term stability of the photoelectron emission.

A study on characteristics of artificial lighting as a method for space image production - with emphasis on visual mass media - (공간이미지연출 기법으로서의 인공광의 특성에 관한 연구 - 대중영상매체를 중심으로 -)

  • 조은아;신홍경
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.183-186
    • /
    • 2003
  • Light is important as to say that it completes space and form. Space that is made by light is not only functional but it can be seen as a place where space and people communicate to each other. Recently mass media is embossed as communication method. Light is the most instant and affluent factor among what consists of the image of space to express sensitivity. Especially the artificial lighting plays an important role in the presentation of space in the mass media with the progress of technology. Therefore this study's purposes are to search how the artificial light present the image of space in the mass media and to suggest alternative methods to present the image with artificial lighting.

  • PDF

Development of NDIR CO2 Gas Detector Using Thermopile Sensor (써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발)

  • Cho, Si-Hyung;Park, Chan-Won
    • Journal of Industrial Technology
    • /
    • v.32 no.A
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

RSOA-Based Wavelength-Reuse Gigabit WDM-PON

  • Kim, Byoung-Whi
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.337-345
    • /
    • 2008
  • This article presents the RSOA-based re-modulation schemes for practical application to the WDM-PON link. Emphasis is put on the three methods for reducing the residual downstream signal in the upstream transmission; the simplest one is to use the RSOA gain-saturation property, the second uses selective filtering of the adiabatic-chirped DFB-LD output spectrum, and the last uses a dynamic RSOA gain control by varying its driving current according to the incident binary signal. The reflection sensitivity in the proposed re-modulation link is also qualitatively presented in the cases of using two different types of seed light: coherent light from DFB-LD array and spectrum-sliced incoherent ASE light. We show experimental results of an error-free bidirectional gigabit transmission over 20 km at -30 dB reflection with the spectrum-sliced ASE seed light.