• Title/Summary/Keyword: ligament fixation device

Search Result 10, Processing Time 0.027 seconds

A Study on the Fixation Characteristics of a Self-expansion Type ACL Fixation Device (자가 확장형 전방십자인대 고정장치의 고정 특성에 대한 연구)

  • Kim, Jong-Dae;Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.3
    • /
    • pp.321-327
    • /
    • 2009
  • This paper studied the influences of the main design parameter-the expansion angle and the material properties of the self-expansion anterior cruciate ligament fixation device on the contact condition with the bone and the initial stability of the device. Using finite element analysis, the stress distributions of the ring part of the device and the wall of the bone tunnel were calculated. And the micro-migration of the device by the pull-out force was calculated. From the analysis results, it was found that when designing the self-expansion type anterior cruciate ligament fixation device, it is desirable to use the material having higher Young's modulus and to design the fixation device that all wedges uniformly maintain contact with bone to obtain initial stability after operation.

  • PDF

The Posterior Cruciate Ligament (PCL) Reconstruction by the Transtibial Tunnel Method using Cadaveric Achilles Tendon Grafts - Evaluation of the Initial Lengthening and the Slippage Ratio due to the Interference Screw Fixation and Double Cross-Pin Fixation - (사체 아킬레스건을 이용한 경골관통터널방식의 후방십자인대 재건술 - 간섭나사 및 이중고정핀 방식에 따른 초기연신 및 활주율 평가 -)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Oh, Dong-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.430-439
    • /
    • 2009
  • Posterior Cruciate Ligament (PCL) plays an important role in knee extension. Rotational instability due to injured PCL can be restored by various PCL reconstruction methods. In this study, the initial lengthening affected by fixation device and location was demonstrated, and furthermore, the slippage and the relationship between lengthening ratio and slippage ratio in the calcaneus and soft tissue fixation methods was newly suggested. Eight specimens of proximal tibia and Achilles tendon grafts were harvested from four cadavers and divided into four groups in regard to the four different types of transtibial fixation techniques. The cyclic load ranged from 50 N to 250 N applied to each graft fixed to proximal tibia in 55 degrees. The initial lengthening ratio to the total elongation has been approximately constant regardless of the fixation methods. The soft tissue fixation method with an interference screw showed about 56.4% slippage ratio to the total elongation and the same method with a double cross-pin presented about 45.4% slippage ratio. The soft tissue fixation method with an interference screw demonstrated approximately 2 mm less total elongation and about 13% more slippage than lengthening because of poor fixation compared to the same method with a double cross-pin.

Slippage Behavior Due to the Calcaneus Fixation and Achilles Tendon Soft Tissue in Posterior Cruciate Ligament (PCL) Reconstruction (PCL 재건술용 아킬레스 이식건의 종골편 고정법과 연부조직 고정법에 따른 활주거동)

  • Kim, Cheol-Woong;Lee, Ho-Sang;Bae, Ji-Hoon;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1527-1532
    • /
    • 2008
  • 45% of the sports accidents is the knee damage and the representative case is the damage of an Anterior Cruciate Ligament (ACL) and the Posterior Cruciate Ligament(PCL). Although the past different views of ACL reconstruction comes to an agreement, the disputes of PCL is remained yet. The most important engineering approach for these various surgery techniques is accurately to understand and to evaluate the fatigue behavior depending on the stress flow and the stress distribution under the allotted load and the cyclic load, which are caused by the graft fixing device, the proximal tibia of the PCL reconstructing structure. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The relationships between the slippage, the extension ratio, and the slippage ratio by the heel bone fixing method and the soft tissue fixing method of the Achilles tendon were also defined. This research will be the essential data to help the resonable operating techniques for the next PCL reconstruction.

  • PDF

Initial Lengthening Behavior of Cadaveric Achilles Tendon Graft After Posterior Cruciate Ligament Reconstruction (후방십자인대 재건술 후 사체 아킬레스 이식건의 초기연신거동)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Lee, Ho-Sang;Wang, Joon-Ho;Park, Jong-Woong;Oh, Dong-Joon
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1461-1466
    • /
    • 2008
  • In the case of Posterior Cruciate Ligament (PCL), the most frequent mechanism is the dashboard injury, which is directly pressurized to the anterior of the proximal tibia in the state of the knee hyperflexion. The PCL associated ligament damage happens when the posterior injury, the varus, the valgus, the hyperextension and the severe vagus torque are out of the critical value of PCL. After the successful operation cases of Anterior Cruciate Ligament (ACL) reconstruction using the allograft were informed from 1986, a number of results kept over the maximum 10 years were reported. Unfortunately, PCL reconstruction are crowded the surgery techniques such as the graft, the tibia fixing method, the fixation device, the location of the femoral tunnel, the number of the graft bundles and PCL reconstruction to access to the stability of the normal joint is being developed. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The initial extension of the Achilles tendon by the fixing device and its location under the cyclic loading, were observed.

  • PDF

Does Second-Generation Suspensory Implant Negate Tunnel Widening of First-Generation Implant Following Anterior Cruciate Ligament Reconstruction?

  • Sundararajan, Silvampatti Ramasamy;Sambandam, Balaji;Singh, Ajay;Rajagopalakrishnan, Ramakanth;Rajasekaran, Shanmuganathan
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.341-347
    • /
    • 2018
  • Purpose: Tunnel widening following anterior cruciate ligament (ACL) reconstruction is commonly observed. Graft micromotion is an important contributing factor. Unlike fixed-loop devices that require a turning space, adjustable-loop devices fit the graft snugly in the tunnel. The purpose of this study is to compare tunnel widening between these devices. Our hypothesis is that the adjustable-loop device will create lesser tunnel widening. Materials and Methods: Ninety-eight patients underwent ACL reconstruction from January 2013 to December 2014. An adjustable-loop device was used in 54 patients (group 1) and a fixed-loop device was used in 44 patients (group 2). Maximum tunnel widening at 1 year was measured by the L'Insalata's method. Functional outcome was measured at 2-year follow-up. Results: The mean widening was 4.37 mm (standard deviation [SD], 2.01) in group 1 and 4.09 mm (SD, 1.98) in group 2 (p=0.511). The average International Knee Documentation Committee score was 78.40 (SD, 9.99) in group 1 and 77.11 (SD, 12.31) in group 2 (p=0.563). The average Tegner-Lysholm score was 87.25 (SD, 3.97) in group 1 and 87.29 in group 2 (SD, 4.36) (p=0.987). There was no significant difference in tunnel widening and functional outcome between the groups. Conclusions: The adjustable-loop device did not decrease the amount of tunnel widening when compared to the fixed-loop device. There was no significant difference in outcome between the two fixation devices. Level of Evidence: Level 3, Retrospective Cohort.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

Comparison of Anterior Cruciate Ligament Reconstructions Using Hamstring Tendon Autograft and Tibialis Tendon Allograft (자가 슬괵건 및 동종 경골건을 이용한 전방 십자 인대 재건술의 결과 비교)

  • Song, Eun-Kyoo;Seon, Jong-Keun;Bae, Bong-Hyun;Park, Sang-Jin;Kim, Jong-Seon;Lee, Dam-Seon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.141-147
    • /
    • 2006
  • Purpose: To compare the clinical and radiological results of anterior cruciate ligament(ACL) reconstruction using hamstring autograft and tibialis tendon allograft. Materials and Methods: Twenty four ACL reconstructions using hamstring autograft and 30 using tibialis anterior tendon altograft were followed up at least 1 year. We performed femoral tunnel fixation with Ligament Anchor(LA) screw and tibial tunnel fixation with biodegradable interference screw. Evaluations included Lysholm knee(LK) score, Tegner activity scale, Lachman test, Pivot-Shift test, Quardriceps atrophy, incision site numbness, anterior knee pain and instrumented anterior laxity with $Telos^{(R)}$ device. Results: Preoperativ mean LK score was $60.3(18{\sim}82)$ in autograft group and 61.2(25-80) in allograft group. Mean LK score improved to $91.6(68{\sim}100)\;and\;92.6(77{\sim}100)$ respectively. Activity level, using Tegner activity scale, slightly decreased compared with that of Preinjury state in both groups. Lachman test, pivot-shift test, Quadriceps atrophy, anterior knee pain, incision site numbness, and anterior drawer test using $Telos^{(R)}$ device showed no significant difference between two groups (p>0.05). Conclusion: In performing the ACL reconstruction, there was no statistically significant difference between hamstring autograft group and tibilis anterior allograft group in clinical or in radiological results.

  • PDF

Arthroscopic Stabilization for Displaced Lateral Clavicular Fractures: Can It Restore Anatomy?

  • Khan, Prince Shanavas;Yoo, Yon-Sik;Kim, Byung-Su;Lee, Seong-Jin;Ha, Jong Mun
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.3
    • /
    • pp.143-148
    • /
    • 2016
  • Background: The purpose of our study was to evaluate the accuracy of reduction based on postoperative computed tomography (CT) images after arthroscopic stabilization using tightrope system for unstable distal clavicle fracture. Methods: Twelve patients with distal clavicle fracture combined with coracoclavicular (CC) ligament injury (type II, V) who received arthroscopically assisted fixation using a flip button device were evaluated for accuracy of reduction using 3-dimensional postoperative CT scan by measuring the degree of distal clavicular angulation and clavicular shortening. Results: Immediate postoperative plain radiograph confirmed restoration of the CC distance (CCD) in 10 patients. At final follow-up, the CCD remained reduced anatomically on plain radiographs in these patients. All patients showed excessive posterior angulation and shortening compared to the opposite side. The average Constant score recovered to 94.8 at final follow-up. Conclusions: Indirect reduction and arthroscopic subacromial approach with flip button fixation of unstable distal clavicle fractures demonstrated favorable clinical results despite unavoidable posterior angulation of distal clavicle and shortening the total length of clavicle.

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF