• Title/Summary/Keyword: lifting class.

Search Result 17, Processing Time 0.022 seconds

The Development Trend of a VTOL MAV with a Ducted Propellant (덕티드 추진체를 사용한 수직 이·착륙 초소형 무인 항공기 개발 동향)

  • Kim, JinWan
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.1
    • /
    • pp.68-73
    • /
    • 2020
  • This purpose of this paper was to review the development trend of the VTOL MAVs with a ducted propellant that can fly like the VTOL at intermediate and high speeds, hovering, landing, and lifting off vertically over urban areas, warships, bridges, and mountainous terrains. The MAV differs in flight characteristics from helicopters and fixed wings in many respects. In addition to enhancing thrust, the duct protects personnel from accidental contact with the spinning rotor. The purpose of the U.S. Army FCS and DARPA's OAV program is spurring development of a the VTOL ducted MAV. Today's MAVs are equipped with video/infrared cameras to hover-and-stare at enemies hidden behind forests and hills for approximately one hour surveillance and reconnaissance. Class-I is a VTOL ducted MAV developed in size and weight that individual soldiers can store in their backpacks. Class-II is the development of an organic VTOL ducted fan MAV with twice the operating time and a wider range of flight than Class-I. MAVs will need to develop to perch-and-stare technology for lengthy operation on the current hover-and-stare. The near future OAV's concept is to expand its mission capability and efficiency with a joint operation that automatically lifts-off, lands, refuels, and recharges on the vehicle's landing pad while the manned-unmanned ground vehicle is in operation. A ducted MAV needs the development of highly accurate relative position technology using low cost and small GPS for automatic lift-off and landing on the landing pad. There is also a need to develop a common command and control architecture that enables the cooperative operation of organisms between a VTOL ducted MAV and a manned-unmanned ground vehicle.

A Data Burst Assembly Algorithm in Optical Burst Switching Networks

  • Oh, Se-Yoon;Hong, Hyun-Ha;Kang, Min-Ho
    • ETRI Journal
    • /
    • v.24 no.4
    • /
    • pp.311-322
    • /
    • 2002
  • Presently, optical burst switching (OBS) technology is under study as a promising solution for the backbone of the optical Internet in the near future because OBS eliminates the optical buffer problem at the switching node with the help of no optical/electro/optical conversion and guarantees class of service without any buffering. To implement the OBS network, there are a lot of challenging issues to be solved. The edge router, burst offset time management, and burst assembly mechanism are critical issues. In addition, the core router needs data burst and control header packet scheduling, a protection and restoration mechanism, and a contention resolution scheme. In this paper, we focus on the burst assembly mechanism. We present a novel data burst generation algorithm that uses hysteresis characteristics in the queueing model for the ingress edge node in optical burst switching networks. Simulation with Poisson and self-similar traffic models shows that this algorithm adaptively changes the data burst size according to the offered load and offers high average data burst utilization with a lower timer operation. It also reduces the possibility of a continuous blocking problem in the bandwidth reservation request, limits the maximum queueing delay, and minimizes the required burst size by lifting up data burst utilization for bursty input IP traffic.

  • PDF

Studies on Electroacupuncture Anesthesia of Experimental Animal (실험동물의 전침마취에 관한 연구)

  • 이성호;이성옥;권건오;김인봉;김덕환;조성환;김무강;김명철;유명조
    • Journal of Veterinary Clinics
    • /
    • v.16 no.2
    • /
    • pp.417-421
    • /
    • 1999
  • To establish the electroacupuncture anesthesia for experimental animal, 5 adult rabbits (Newzealand-white species) and 6 rats (Spraque-dawley) were examined. The acupoints used for electroacupuncture anesthesia were Tian-ping and Bai-hui. After perpendicular insertion of needle to the acupoints, positive electrode was connected at Tian-ping and negative electrode was connected at Bai-hui using veterinary electroacupuncture anesthesia apparatus, respectively. Electric conditions were 2~3 V and 30 Hz in rabbits, and 1.5~2 V and 30 Hz in rats, respectively. To examine the effect of electroacupuncture anesthesia, laparotomy (2 heads), castration (2 heads) and ovariohysterectomy (1 head) were applied in rabbits, and laparotomy (5 heads) and castration (1 head) were peformed in rats, respectively. The induction time of electroacupuncture anesthesia was very rapid and approximately 1 minute, and pain of body surface including the extremities was not detected in rabbits and rats. As for the reactions with electroacupuncture anesthesia, consciousness was vivid, blepharoreaction was not observed and the tail was up at early stage but was down afterwards in rabbits. The same findings except cotinuous lifting of the tail were observed in rats. The pain was not observed during incision and suture, bleeding was comparatively small volume and the class of anesthesia effect was excellent.

  • PDF

SCANNING ELECTRON MICROSCOPIC STUDY OF LINK PLUS PIN IN DENTIN (상아질에 장착된 Link plus pin의 주사전자현미경적 연구)

  • Um, Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.205-210
    • /
    • 1989
  • The purpose of this study was to observe the minim pins of Link plus (which has buttress thread and shoulder stop design) inserted into dentin and the dentin surrounding pin. The gingival walls of class II cavity were prepared with high speed handpiece in molar teeth not elapsed time after teeth were extracted, and pinhole of 2mm in depth was positioned about 1 mm to the dentinoenamel junction and minim pin was inserted with wrench. After initial examination of the specimens, the specimens were sectioned longitudinally and horizontally to the pins with carborundum disc and low speed diamond saw (Isomet Buehler Ltd) All specimens were coated Au of 250-300${\AA}$ in thickness with Ion Sputter JFC 100 and observed under Scanning Electron Microscope (JSM-35) The following results were obtained. 1. The shoulder stop was seated on the enterance of pinhole in gingival wall, and there were the irregular space between the pin and dentin at the enterance to the pin hole and flakes of dentin lifting from the dentin floor. 2. In case of section to pin horizontally or longitudinally, the dentin debris were observed in gap between pin and dentin, and small cracks were often seen in the dentin surrounding minim pins.

  • PDF

Full Mouth Rehabilitation of a Patient with Bite Collapse in the Molar Area Using Removable Partial Denture and Dental Implant Prosthetics

  • Hong, Jun-Won;Seo, Jae-Min;Seong, Dong-Hwan;Song, Gwang-Yeop;Park, Ju-Mi;Ahn, Seung-Geun
    • Journal of Korean Dental Science
    • /
    • v.3 no.2
    • /
    • pp.40-49
    • /
    • 2010
  • Dental clinicians often encounter cases wherein the patient's lost molar area was neglected and left untreated for an extended period of time, thereby causing the extrusion of opposite molars and occlusal disharmony as well as occlusion in the anterior teeth and consequently resulting in anterior displacement in the area. Clinicians normally carry out prosthetic treatment via occlusal plane lifting when such becomes absolutely necessary due to the lack of sufficient space needed for prosthetic therapy aimed at proper anterior and lateral induction. In this case report, we examined occlusal disharmony and VDO loss in a patient who had lost his molars and had not received prosthetic treatment for an extended period of time. We treated the maxillary area with dental implant prosthetics and Kennedy Class I RPD and the mandibular area with residual natural tooth-based implant placement and dental implant prosthetics. The patient reported treatment outcomes that were deemed satisfactory both functionally and aesthetically.

  • PDF

Reliability and Validity of the Neck Disability Index in Neck Pain Patients (경통 환자 평가를 위한 Neck Disability Index의 신뢰도와 타당도)

  • Lee, Eun-Woo;Shin, Won-Seob;Jung, Kyoung-Sim;Chung, Yi-Jung
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.97-106
    • /
    • 2007
  • The purpose of this study was to determine reliability and validity of the Neck Disability Index (NDI) now in use for the first time in neck pain patients of Korea. Fifty subjects (26 males and24 female) with neck pain enrolled in the study. They completed a standardized self-administered questionnaire that include pain intensity, personal care, lifting, reading, headaches, concentration, work, driving, sleeping and recreation. Reliability was determined by intra-class correlation coefficient (ICC) and Cronbach's alpha by internal consistency. Validity was examined by correlating the NDI scores to the Visual Analog Scale (VAS) score. The Test-retest reliability of the translated versions of the NDI was good ICC (2,1) = .90 (95%CI .85 .95). Cronbach's alpha value for NDI was found to be .95 and this was statistically significant (p<.05). The criterion-related validity coefficients was .72 (p<.01). We conclude that the Korean version of NDI has shown to be a reliable and valid instrument for the assessment of neck pain.

  • PDF

Frequency of different maxillary sinus septal patterns found on cone-beam computed tomography and predicting the associated risk of sinus membrane perforation during sinus lifting

  • Sigaroudi, Ali Khalighi;Kajan, Zahra Dalili;Rastgar, Shabnam;Asli, Hamid Neshandar
    • Imaging Science in Dentistry
    • /
    • v.47 no.4
    • /
    • pp.261-267
    • /
    • 2017
  • Purpose: Analyzing different patterns of maxillary sinus septa in cone-beam computed tomography (CBCT) images and predicting maxillary sinus membrane perforations. Materials and Methods: In this cross-sectional study, CBCT images of 222 patients ranging from 20 to 81 years old were evaluated. One hundred fifty-two patients (93 females and 59 males) who had maxillary sinus septa in axial views were included in this study. Cross-sectional images were used to determine classifications of sinus septa and the risk of membrane perforation using a method modified from Al-Faraje et al. Variables of sex, age, and dental status were considered. Chi-squared and Kruskal-Wallis tests were used for data analysis(P<.05). Results: In this study, 265 maxillary sinus septal patterns were found. The mean age of the patients was $44.1{\pm}14.7$ years old. The Class I and VII-div II patterns had the greatest and least prevalence, respectively. Furthermore, there was a significant relationship between the location of septa and the frequency of membrane perforation risk (P<.05). In this study, the relationship of different patterns of septa with dental status did not differ significantly (P>0.05). Conclusion: A higher prevalence of moderate risk of membrane perforation in the molar region relative to the premolar region was observed. Furthermore, maxillary sinus septa occur most frequently in the molar region, demonstrating the importance of paying attention to this region during sinus lift surgery. This study did not show any relationship between tooth loss and the presence of septa.