• Title/Summary/Keyword: lgM

Search Result 558, Processing Time 0.028 seconds

Isolation of Marine Bacteria Killing Red Tide Microalgae -III. Algicidal Effects of Marine Bacterium, Micrococcus sp. LG-5 against the Harmful Dinoflagellate, Cochlodinium polykrikoides- (적조생물 살조세균 탐색 -III. 유해성 적조생물 Cochlodinium polykrikoides에 대한 Micrococcus sp. LG-5의 살조 효과-)

  • JEONG Seong-Youn;PARK Young-Tae;LEE Won-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.331-338
    • /
    • 2000
  • The algicidal effects of marine bacteria were investigated and a strain, which had the strongest algicidal activity against the harmful dinoflagellate, Cochiodinim polykrikoides was selected. The bacterium was isolated in seawater during the period of blooming of C. polykrikoides in Masan Bay. This algicidal bacterium was identified as Micrococcus sp. LG-5 by means of morphological and biochemical tests. The optimal culture conditions of Micrococcus sp, LG-5 were $25^{\circ}C,\;pH 7.0\;and\;3.0{\%}$ NaCl concentration. The algicidal activity of Micrococcus sp. LG-5 was significantly increased to maximum value in the late of logarithmic phase of cell cuture. In addition, the culture filtrate ($pore size,\;0.1{\mu}m$) of Microcoocus sp. LG-5 showed strong algicidal effects. The cell numbers of C. polykikoides were decreased from $1.2{\times}10^4 cells/ml\;to\;less\;than\;2{\times}10^3\;cells/ml$ within 3, 6, 30 hours at the concentrations of culture filtrate $10{\%},\;5{\%}\;and\;1{\%}$, respectively. These results indicated that the algicidal effect was mediated by certain substances released from Microooccus sp. LG-5.

  • PDF

Detection of a Moving Object by Multi-channel SQUID Magnetometer System (다중채널 고온초전도 양자간섭소자 자력계 시스템을 이용한 이동 물체 탐지)

  • Lee, H.J.;Lee, S.-M.;Lee, H.N.;Yun, J.H.;Moon, S.H.;Lim, S.H.;Kim, D.Y.;Oh, B.
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.56-59
    • /
    • 2001
  • We have constructed a multi-channel SQUID magnetometer system for localization and classification of magnetic targets. Ten SQUID magnetometers were arranged to measure 5 independent components of 3 $\times$ 3 magnetic field gradient tensor. To get gradient from the difference of magnetic field measurements, we carefully balanced magnetometers. SQUIDs with slotted washer were used for operation in an unshielded laboratory environment, and noise characteristic in the laboratory was measured. With the multi-channel SQUID magnetometer system, we have successfully traced the motion of a bar magnet moving around it at a distance of about 1 m. In the urban environment, the drift of uniform magnetic field due to the irregular motion of a large magnetic body at distance and earth field causes an error in the position calculation, and this results in the distortion of the calculated trajectory. In this paper, we present the architecture and the performance of the system.

  • PDF

2.8 inch QVGA System On Panel LCD Employing Advanced CMOS LTPS Technology

  • Yoon, Ji-Mo;Yoo, Juhn-S.;Yu, J.S.;Kim, E.;Son, C.Y.;Park, J.K.;Yoo, Y.S.;Lim, K.M.;Kim, C.D.;Chung, I.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.285-288
    • /
    • 2005
  • A 2.8 inch fully integrated SOP employing a high performance LTPS CMOS TFT technology has been developed for mobile display applications. The LCD module is directly interfaced with 3V 6-bit RGB source via timing control circuitry. The integrated data driver comprises a 6-bit hybrid type DAC with low power analog buffer.

  • PDF

New Cu Process and Short Channel TFT

  • Yang, J.Y.;Hong, G.S.;Kim, K.;Bang, J.H.;Ryu, W.S.;Kim, J.O.;Kang, Y.K.;Yang, M.S.;Kang, I.B.;Chung, I.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1189-1192
    • /
    • 2009
  • Short channel a-Si:H TFT devices with Cu electrodes have been investigated. Short channel TFTs are defined by new plasma etch process. When the channel length becomes shorter, the TFT characteristics (threshold voltage, off current, sub threshold voltage, etc.,) are degraded. These degraded characteristics can be improved through the hydrogen plasma treatment and new gate insulator structure. Using these processes, 15.0 inch XGA LCD panel was fabricated successfully where the channel length of the TFT devices was about 2.5 micrometers.

  • PDF

A Study on Channel Capacity when support Multimedia Service Using LMDS System (LMDS 시스템을 이용한 멀티미디어 서비스 제공시 채널용량에 관한 연구)

  • Kwak, O. M.;Kim, D. H.;Park, D. I.;Youm, J. W.;Choi, K. J.
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.193-196
    • /
    • 1998
  • 본 논문에서는 DAVIC 표준안에 근거하여 주파수 대역폭이 하향스트림 120MHz와 상향스트림 60MHz로 디지털 LMDS 서비스 망이 구축되었을 때, 하향스트림과 상향스트림 구조 및 프레임 관계에 대하여 기술하고, 이를 기반으로 하여 LMDS 상에서 멀티미디어 서비스 제공시 음성:전용회선:데이터를 10%:30%:60% 비율로 가정하고 서비스별 수용 가능한 가입자 채널 용량을 산출하였다.

  • PDF

PD Characteristics in C-GIS Using AE Sensor (AE Sensor를 적용한 C-GIS내의 PD 특성)

  • Lee, Yong-Hee;Shin, Yang-Sop;Jang, Su-Hyeong;Seo, Jung-Min;Lee, Yong-Hee;Lim, Ki-Joe
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1652-1654
    • /
    • 2002
  • The defects making partial discharge(PD) in a C-GIS(Cubicle Insulated Switchgear) initiate acoustic wave which can be detected using acoustic emission sensor placed outside or inside the C-GIS enclosure. In this paper, partial discharge property for 2 locations for AE sensor and 3 locations for defects in C-GIS are presented and PD waveforms were analyzed by PRPDA(Partial Resolved Partial Discharge Analysis). As a result, using post amplifier having gain of 10,000 and band pass filter having $20kHz{\sim}300kHz$, resolution of waveforms AE sensor signal by detected was good. Noise level was about 80 mV.

  • PDF

The Improvement of the Off-Current Characteristics in the Short Channel a-Si:H TFTs

  • Bang, J.H.;Ahn, Y.K.;Ryu, W.S.;Kim, J.O.;Kang, Y.K.;Yang, J.Y.;Yang, M.S.;Kang, I.B.;Chung, I.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.867-869
    • /
    • 2008
  • We have investigated the effects of hydrogen plasma treatment by PECVD (Plasma Enhanced Chemical Vapor Deposition) in the back channel region, the method for reducing the off state leakage current which increases with the short channel length of a-Si:H TFTs. To improve the off current characteristics, we analyzed the hydrogen plasma treatment with various RF power and plasma treatment times of PECVD. As the result of hydrogen plasma treatment in the back channel region it was remarkably reduced the off current level of 2um channel length TFT.

  • PDF

The development of 42' 2D/3D switchable display

  • Kang, H.;Jang, M.K.;Kim, K.J.;Ahn, B.C.;Yeo, S.D.;Park, T.S.;Jang, J.W.;Lee, K.I.;Kim, S.T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.1311-1313
    • /
    • 2006
  • Stereoscopic/autostereoscopic systems have been developed in order to express true 3D images, but have never had great success in the practical use. In order to apply 3D display to promising applications such as advertisements and games, we've developed a 42" 2D/3D switchable display. It has characteristics that don't require special glasses for 3D images, use multi-view technology for improving 3D viewing characteristics, and has a 2D/3D switching function to express dynamic 3D contents as well as conventional 2D contents.

  • PDF

Development of Link Mechanism for a 154kV Cross Linked Polyethylene Cable on Bridge (교량 첨가 전력 케이블 신축균등흡수장치 개발)

  • Oh, J.O.;Ro, K.J.;Heo, H.D.;Lee, S.H.;Kim, W.B.;Kim, C.M.;Lee, T.J.;Kim, C.S.;Baek, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2081-2082
    • /
    • 2000
  • 서강대교와 같은 장경간 교량에 초고압 전력케이블을 설치하는 경우에는 교량의 큰 신축을 흡수하기 위하여 케이블을 장대옵셋으로 설치하는 것이 불가피하게 되고, 장대옵셋 케이블이 균등하게 변형할 수 있도록 신축균등흡수장치를 실증시험을 통하여 국내에서 최초로 개발하고 154kV 중여T/L 구간중 서강대교에 총12기를 설치 완료하였다. 본 고에서는 그 개요를 소개하고자 한다.

  • PDF

Evaluation of accuracy for measurement of Dioxins (PCDDs/PCDFs) by using certified reference material (CRM) (인증표준물질(Certified reference materials, CRM)을 이용한 이옥신류(PCDDs/PCDFs) 측정의 정확도 평가)

  • Youn, Yeu Young;Park, Deok Hie;Lim, Young Hee;Cho, Hye Sung
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.376-385
    • /
    • 2009
  • In our study, the accuracy for measurement of seventeen 2,3,7,8-substituted PCDDs/PCDFs in certified reference material (CRM) which is the sample of homogeneous sediment matrix taken from an area known to have significant chemical contamination, particularly PCBs (polychlorinated biphenyls), was evaluated. Though the methodology in this study followed the official method of unintentionally produced persistent organic pollutants (UPOPs) announced by the Ministry of Environment of the Republic of Korea in 2007, there were slight changes using additional purification step by activated carbon column because the interferences of sample were not sufficiently removed when only multi-silica column and alumina column have been used for purification. The |En| number proposed by the Korea Research Institute of Standards and Science was used for a valuation basis of the accuracy. The |En| numbers of seventeen 2,3,7,8-substituted PCDDs/PCDFs have been indicated as 1 and below, they were decided "Pass" in this test, when DB-5MS column and SP-2331 column were used together. Because 1,2,3,7,8-PeCDD and #169-HxCB were not separated on DB-5MS column, the ions of 1,2,3,7,8-PeCDD were selected at M/M+2 instead of M+2/M+4 suggested by EPA 1613. It is possible to distinguish them in HRGC/HRMS analysis.