• Title/Summary/Keyword: leaking gas

Search Result 58, Processing Time 0.018 seconds

A Study on the Establishment of Process Safety Management (PSM) System for Small and Medium Size Chemical Plants (중소화학공장의 공정안전관리(PSM)시스템 구축에 관한 연구)

  • Baek Jong-Bae;Ko Jae-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.1
    • /
    • pp.8-13
    • /
    • 1999
  • The article 49-2 of Industrial Safety Law requires that all the owners of industrial plants which contains dangerous facilities perform the process safety management. That is, this law requires the owners of industrial plants to take necessary measures to prevent fire, harmful gas leaking, explosion, and other serious accidents that could cause demage and injuries to the employees. So far, domestic chemical plants have tried to invest money and time in safety management. But, such efforts have been made only in chemical plants that were subsidiaries of large business groups. Moreover, since the economic crisis of Korea which is symbolized by the IMF bailout, small and medium size companies could not afford to invest in safety management. Their major concern is to increase productivity and thereby, survive in this crisis. The goal of this research is to develop the process safety management system that can help small and medium size companies to positively secure the process safety management. So, in developing the process safety management system, the financial and practical difficulties of such companies are fully taken into consideration.

  • PDF

A Study on the New Method by EMPLUX for Soil-Remediation(1) (토양오염 복원을 위한 EMPLUX를 사용한 새로운 방법에 대한 연구)

  • Kim, Jung-Sung
    • Journal of Environmental Science International
    • /
    • v.16 no.12
    • /
    • pp.1325-1335
    • /
    • 2007
  • The utility of soil-gas surveys is directly proportional to their accuracy in reflecting and representing changes in the subsurface concentrations of source compounds. Passive soil-gas vapor-phase is merely a fractional trace of the source, so, as a matter of convenience, the units used in reporting detection values from EMFLUX surveys are smaller than those employed for source-compound concentrations. According to the Leaking Underground Storage Tank(LUST) Program Annual Report, approximately 16 U.S. million dollars were spent for environmental site investigations at over 1,600 Underground Storage Tank(UST) sites and approximately over 1,000 acres of land was characterized and remediated in the State of Illinois in the year of 2003 alone. The main purpose of this study is to propose an idea to significantly reduce the site investigation cost by utilizing a passive soil-gas survey and conventional intrusive drilling method and to fully define the three dimensional characteristics of subsurface contamination from two industrial drycleaning facilities.

DetGas: A Carbon Monoxide Gas Leakage Detector Mobile Application

  • Kamaruddin, Farhan Fikri Mohd;Hadiana, Ana;Lokman, Anitawati Mohd
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.59-66
    • /
    • 2021
  • Many incidents of Carbon Monoxide (CO) poisoning have occurred because of people being unaware of its presence. There are currently available systems on the market, but they are limited to measuring CO in a certain area and lack vital functions. Additionally, little to no evidence-based information on their quality was available. Thus, a mobile application for detecting CO gas leakage in a vehicle and critical features to assist victims was developed. A usability and functionality test were conducted to determine the product's quality utilizing nine usability and six functionality task scenarios (n=5). Then, a System Usability Scale test was performed to obtain system satisfaction, usability, and learnability (n=50). The usability and functionality test shows that all the tasks given for both tests were 100% successful. The overall score obtained for SUS was 71.4, which indicates good acceptance and usability. Around 20% of respondents claimed that they would need the support of a technical person to be able to use the application and that they needed to learn a lot of things before they could use the application, which indicates the overall high learnability of the application. The result provides empirical evidence that the CO gas leakage detection mobile application is successful and receives good usability, functionality, acceptability, learnability, and satisfaction assessments. DetGas could benefit automobile owners and other stakeholders by mitigating the risk and harm associated with gas leaking that exceeds the safe limit.

A Study on the Diffusion Behavior of Leak Gas from Underground Gas Pipeline (지하매설 가스배관의 가스 누출시 지하 확산거동에 관한 연구)

  • Choi S.C.;Jo Y.D.;Kim K.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.43-52
    • /
    • 1999
  • An experimental chamber was fabricated to observe the gas diffusion behavior of leak gas from underground city-gas pipeline. It was made of acryl so that feeding of gas and the measuring points of the gas could be varied in each experiment. The MOS sensors were used to measure the concentrations of leak gas. The soil media such as the Jumunjin standard sand and the granite weathered soil were used to measure the gas diffusion and the change of leak gas concentrations was measured with time for various gas flow rate. As the distance between the leak point of gas and the measuring point of MOS sensor decreases, or the leak rate increases, the detection time of gas at a measuring points decreases and the gas concentration increases quickly and the concentration of the gas at steady state also increases. As the density of granite weathered soil is higher than that of Jumunjin standard sand for compaction, the detection time of leak gas in the granite weathered soil was longer than that in the Jumunjin standard soil. The leak gas concentrations in the granite weathered soil were lower than those in the Jumunjin standard sand at the beginning of gas leaking from a pipe, but inverse phenomenon was occured at steady state.

  • PDF

A study on the Internal Flow Analysis of Gas Cylinder Cabinet for Specialty Gas of Semiconductor (반도체용 특수가스 공급을 위한 가스캐비닛 내부 유동해석에 관한 연구)

  • Kim, Jung-Duck;Han, Seung-A;Yang, Won-Baek;Rhim, Jong-Guk
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.5
    • /
    • pp.74-81
    • /
    • 2020
  • In general, when manufacturing a semiconductor, a number of hazardous and dangerous substances such as flammability, toxic, and corrosiveness are used. In particular, semiconductors are manufactured using specialty gas in processes such as CVD and etching. The specialty gas is filled in a container in the state of compressed or liquefied gas, and a gas cylinder cabinet is used as a facility for supplying this specialty gas to the semiconductor manufacturing process. When a accident occurs in the gas supply system, gas is released through a pressure release device installed in the gas cylinder to secure the safety of the supply system. In this case, the gas released inside the gas cabinet, there is a risk of leaking to the outside. After that, by analyzing the gas flow in the gas cabinet, it is intended to identify the risk associated with leak and to provide measures to prevent accidents.

A Study on the Improvement of Risk Assessment Items and Index for Sunken Ship (침몰선박 위해도 평가항목 및 평가지수 개선에 관한 연구)

  • Lee, Seung-Hyun;Choi, Hyuek-Jin;Suh, Jae-Joon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.704-711
    • /
    • 2015
  • In this study, we have conducted a survey of AHP technique through the ocean experts to derive new items and revise assessment items and indices for risk of sunken ships based on the survey results. As a result of the survey, two new items such as accident cause and tidal current are derived. And it shows that existing items such as toxic liquid substance, remaining oil and explosive gas which were evaluated as one group are desirable to be evaluated respectively. Accordingly, we analyze the indices of the new eleven assessment items adjusted from the existing seven assessment items. As a result, the indices are ordered by toxic liquid substance, possibility of leaking, explosive gas, carrying capacity of fuel oil, sensitivity of sea environment, marine traffic environment, cause of accident, tidal current, keel clearance, ship type, and ship size. Especially, as compared with the indices of existing assessment items, the indices of sensitivity of sea environment and possibility of leaking are higher and the index of keel clearance is lower.

A Study on the Improvement of Leak Alarm Reliability of Gas Meter for Leak Inspection according to Boiler Usage Pattern (보일러 사용 패턴에 따른 누출점검용 가스계량기 누출 알람 신뢰도 개선 연구)

  • Jin-Du Yang;Seung-Won Lee;Eun-Il Choi;Sung-Hyeon Lim
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.72-76
    • /
    • 2023
  • Among urban gas-using facilities, more and more cases are using gas meters for leakage inspection instead of inspection ports for concealment pipes. Leak alarm alarms were continuously generated according to the boiler's special usage pattern in an environment where there was no actual gas leakage among some households where this meter was installed. It does not perform its original function of detecting actual gas leakage. Based on these problems, this study analyzed the conditions under which the gas meter for leakage inspection generates leakage alarms according to the boiler's special gas use pattern, and sought a set value that can generate an alarm only in the case of actual gas leakage. Through this, it is intended to relieve citizens' anxiety about gas use due to malfunction of the alarm and at the same time perform the original function of the meter that can detect leaking gas.

Mobile Sensor Velocity Optimization for Chemical Detection and Response in Chemical Plant Fence Monitoring (사업장의 경계면에서 화학물질 감지 및 대응을 위한 이동식 센서 배치 최적화)

  • Park, Myeongnam;Kim, Hyunseung;Cho, Jaehoon;Lulu, Addis;Shin, Dongil
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.2
    • /
    • pp.41-49
    • /
    • 2017
  • Recently, as the number of facilities using chemicals is increasing, the amount of handling is rapidly increasing. However, chemical spills are occurring steadily, and if large quantities of chemicals are leaked in time, they are likely to cause major damage. These industrial complexes use information obtained from a number of sensors to detect and monitor leaking areas, and are used in industrial fields by applying existing fixed sensors to robots and drones. Therefore, it is necessary to propose a sensor placement method at the interface for rapid detection and response based on various leaking scenarios reflecting leaking conditions and environmental conditions of the chemical handling process. In this study, COMSOL was used to analyze the actual accident scenarios by applying the medium parameter to the case of chemical leaks. Based on the accident scenarios, the objective function is selected so that the velocity of each robot is calculated by attaching importance to each item of sensor detection probability, sensing time and sensing scenario number. We also confirmed the feasibility of this method of reliability analysis for unexpected leak accidents. Based on the above results, it is expected that it will be helpful to trace back the leakage source based on the concentration data of the portable sensor to be applied later.

HONEYCOMB LABYRINTH SEAL LEAKAGE CHARACTERISTIC ANALYSIS WITH ACTUAL OPERATING CONDITIONS ON THE COMPRESSOR OF GAS TURBINE (가스터빈 압축기용 허니컴 래버린스 실의 실제 운전조건에 따른 누설량 특성 분석)

  • Lim, S.B.;Kim, M.K.;Kang, Y.H.;Park, W.G.
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.102-108
    • /
    • 2015
  • Recently, There are many studies in progress in order to improve the efficiency of the gas turbine. Leakage in losses of the gas turbine account for the largest proportion. Seal is a sealing device to reduce the flow from leaking by the pressure difference inside the turbine. Compressor has another value according to the shape and pressure conditions in each stage. Thus, it is necessary to seal design for boundary conditions in order to minimize leakage. At the actual operating conditions of the compressor, numerical analysis of honeycomb labyrinth seal was performed in accordance with pressure, temperature, rotor speed for CFD. As a result, when the temperature increases, the leakage is decreased. Also, when the pressure increases linearly with increased leakage, and there was no effect of the rotation speed.

Feasibility Study on the Utilization of EMAT Technology for In-line Inspection of Gas Pipeline

  • Cho, Sung-Ho;Yoo, Hui-Ryong;Rho, Yong-Woo;Kim, Hak-Joon;Kim, Dae-Kwang;Song, Sung-Jin;Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2011
  • If gas is leaking out of gas pipelines, it could cause a huge explosion. Accordingly, it is important to ensure the integrity of gas pipelines. Traditionally, over the years, gas-operating companies have used the ILI system, which is based on axial magnetic flux leakage (MFL), to inspect the gas pipelines. Relatively, there is a low probability of detection (POD) for the axial defects with the axial MFL-based ILI. To prevent the buried pipeline from corrosion, it requires a protective coating. In addition to the potential damage to the coating by environmental factors and external forces, there could be defects on the damaged coating area. Thus, it is essential that nondestructive evaluation methods for detecting axial defects (axial cracks, axial groove) and damaged coating be developed. In this study, an electromagnetic acoustic transducer (EMAT) sensor was designed and fabricated for detecting axial defects and coating disbondment. In order to validate the performances of the developed EMAT sensor, experiments were performed with specimens from axial cracks, axial grooves, and coating disbondment. The experimental results showed that the developed EMAT sensor could detect not only the axial cracks (minimum 5% depth of wall thickness) and axial grooves (minimum 10% depth of wall thickness), but also the coating disbondment.