• 제목/요약/키워드: leakage problems

검색결과 551건 처리시간 0.025초

건물의 유효누출면적 및 박스모델을 이용한 염소 실내 누출의 위험지역 완화에 관한 연구 (A Study on the Mitigation of Threat Zones for Indoor Chlorine Release using Effective Leakage Areas of Building and Box Model)

  • 곽솔림;이은별;최영보
    • 한국안전학회지
    • /
    • 제33권5호
    • /
    • pp.51-59
    • /
    • 2018
  • It is difficult to determine the outdoor toxic level of hazardous chemicals that are leaked in the building, since there are no efficient ways to calculate how much percentage of the leaked chemicals is released into the outdoor atmosphere. In address to these problems, we propose a reasonable box model that can quantitatively evaluate the mass rate of the indoor chlorine leakage into the outside of the building. The proposed method assumes that the indoor chlorine leakage is fully mixed with the indoor air, and then the mixture of the chlorine and indoor air is exfiltrated into the outside of the building through effective leakage areas of the building. It is found that the exfiltration rate of the mixture of the chlorine and indoor air is strongly dependent on the temperature difference between inside and outside the building than the atmospheric wind speed. As compared with a conventional method that uses a vague mitigation factor, our method is more effective to evaluate the outdoor toxic threat zone of the chlorine that are leaked in the building, because it can consider the degree of airtight of the building in the evaluation of the threat zone.

A COUPLED CFD-FEM ANALYSIS ON THE SAFETY INJECTION PIPING SUBJECTED TO THERMAL STRATIFICATION

  • Kim, Sun-Hye;Choi, Jae-Boong;Park, Jung-Soon;Choi, Young-Hwan;Lee, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제45권2호
    • /
    • pp.237-248
    • /
    • 2013
  • Thermal stratification has continuously caused several piping failures in nuclear power plants since the early 1980s. However, this critical thermal effect was not considered when the old nuclear power plants were designed. Therefore, it is urgent to evaluate this unexpected thermal effect on the structural integrity of piping systems. In this paper, the thermal effects of stratified flow in two different safety injection piping systems were investigated by using a coupled CFD-FE method. Since stratified flow is generally generated by turbulent penetration and/or valve leakage, thermal stress analyses as well as CFD analyses were carried out considering these two primary causes. Numerical results show that the most critical factor governing thermal stratification is valve leakage and that temperature distribution significantly changes according to the leakage path. In particular, in-leakage has a high possibility of causing considerable structural problems in RCS piping.

국내 공동주택 지하주차장의 누수 실태 및 주요 누수 부위 조사 (Leakage Situation and Main Leakage Areas of Domestic Residential Building Underground Parking Lots)

  • 이정훈;송제영;오상근
    • 한국건설순환자원학회논문집
    • /
    • 제4권4호
    • /
    • pp.496-503
    • /
    • 2016
  • 본 연구에서는 현재 국내 공동주택 지하주차장의 누수실태를 파악하고, 실제 누수가 가장 빈빈하게 발생되고 있는 주요 누수부위를 파악하여 향후 공동주택 지하부위 누수 예방을 위한 기초자료로 기여하고자 하였다. 18개 단지를 대상으로 누수실태 조사를 진행한 결과 외방수를 적용한 전체 80% 단지에서 누수가 발생되지 않았으나, 내방수를 적용한 단지에서는 전부 누수가 발생되고 있었다. 방수와 관련된 건설분야에 종사하는 전문가를 대상으로 진행한 설문조사 결과, 현재 공동주택 지하주차장의 누수 문제는 심각한 수준으로써, 누수에 대한 대책이 요구되며, 무엇보다 정책적 기준 마련이 중요하다고 판단하고 있다. 누수 실태조사 결과와 설문조사 결과를 비교, 분석한 결과 누수가 빈번한 주요 구조부위는 외벽과 최하층 바닥 슬래브이며, 누수 취약부위는 벽체 시공 이음부와 바닥 신축줄눈으로 판단할 수 있었다. 향후 해당부위의 누수 예방을 위한 방수 설계지침 및 시공시방 등에 대한 후속적인 연구가 필요하겠다.

16비트 신호처리 프로세서 기반 유효성분 누설전류 감지 알고리즘 구현 (The Implementation of Active Leakage Current Detecting Algorithm based on 16 bit Signal Processor)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제11권6호
    • /
    • pp.605-610
    • /
    • 2016
  • 누전차단기는 전기재해로 인한 사고를 미연에 방지하기 위해 사용되는 유일한 방법이다. 그러나 기존의 누전차단기는 15mA~30mA의 차단범위에서 합성 누설전류를 검출하여 동작하기 때문에 저항성 누설전류에 의해 발생하는 화재 및 인체감전으로 인한 인명 및 재산피해를 미연에 방지하는데 한계가 있다. 또한 용량성 누설전류에 의한 오동작으로 인한 생산성 감소 및 신뢰성 등의 문제를 가지고 있다. 본 연구에서는 기존 누전차단기의 문제를 해결하기 위해 위상차를 측정을 통하여 유효성분(저항성) 누설전류를 감지할 수 있는 알고리즘을 개발하였고, 감지된 누설전류를 기술표준규격에서 규정하는 0.03초 이내에 차단을 할 수 있도록 16 bit 신호처리 프로세서인 MSP430 프로세서를 사용하여 유효성분 누설전류 감지 알고리즘을 구현하였다.

유경성 대망이식편을 이용한 술후 식도천공 치험1례 (Surgical Treatment of Postoperative Leakage with Pedicled Omental Flap)

  • 임창영;김요한;유회성
    • Journal of Chest Surgery
    • /
    • 제26권4호
    • /
    • pp.325-328
    • /
    • 1993
  • The pedicled omental flap has been used for treatment of various kind of complications in thoraxcic surgery. Its property of promoting neovascularization , immunilogic properties that limiting the spread of infection, providing soft tissue coverage are very effective in treatment esophageal fistulas. Also, congenital broncho-esophageal fistula [ BEF ] is a rare disease entity which was reported about 100 cases around the world. We experienced 27 years old female patient with Braimbridge type I congenital BEF. We performed division of BEF using stapler and pericardial patch coverage of esophageal side with concomittent left lower lobectomy. This patient was complicated with postoperative esophageal leakage with empyema thoracis. We have successfully managed these problems with re-thoracotomy and re-closure of esophageal fistula using Right Gastroepiploic Artery based pedicled omental flap wrapping around the esophageal anastomosis site. It is felt that pedicled omental flap is a very effective method to manage esophageal complication such as postoperative esophageal leakage.

  • PDF

석탄화력 탈황설비 Non-leakage Type Gas-Gas Heater(GGH) 운영 및 개선사례 (Operation and Improvement Cases of FGD Non-leakage Type Gas-Gas Heater(GGH) for Coal Fired Power Plants)

  • 성기종;이창식
    • 한국연소학회지
    • /
    • 제22권4호
    • /
    • pp.35-42
    • /
    • 2017
  • This case covers the issues related to the operation problem, cause analysis and improvement cases of the FGD that employed the non-leakage type GGH in coal-fired power plant for the first time in Korea. In the Cooler, there was a main problem that the tube is damaged by the ash cutting due to the high velocity of flue gas in the duct and by the weak wear resistance of material. In the Reheater, there was a main problem that the tube was corroded due to chlorine and sulfur in the circumstance of the low temperature. In order to solve those problems, we have improved the Reheater tube and tube fins by coating enamel to reduce corrosion rate.

액셜 피스톤 펌프 . 모터의 피스톤 구면부 정압 윤활특성 (Hydrostatic Bearing Characteristics of Slipper in Piston Pump . Motor)

  • 박경민;김종기;오석형;송규근;정재연
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제34회 추계학술대회 개최
    • /
    • pp.186-193
    • /
    • 2001
  • In the high pressure state, the leakage flow rate of hydraulics is one of serious problems and the great reason to decrease the volume efficiency. In this paper, I tried to clarify tribology characteristics for the slipper hydrostatic bearing in swash plate type axial piston pumps and motors by means of experiment . I measured the leakage flow rate between swash plate and piston shoe with change the supply pressure and oil temperature at a swash plate angle of 0。 . And I also investigated the slipper pocket pressure and calculated oil film thickness for theoretical method. So. 1 have analyzed the tribology characteristics of hydrostatic bearing for leakage flow rate and oil film thickness with oil temperature and supply pressure.

  • PDF

미세소자에서 누설전류의 분석과 열화 (Analysis and Degradation of leakage Current in submicron Device)

  • 배지철;이용재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 추계학술대회 논문집
    • /
    • pp.113-116
    • /
    • 1996
  • The drain current of the MOSFET in the off state(i.e., Id when Vgs=0V) is undesired but nevertheless important leakage current device parameter in many digital CMOS IC applications (including DRAMs, SRAMs, dynamic logic circuits, and portable systems). The standby power consumed by devices in the off state have added to the total power consumed by the IC, increasing heat dissipation problems in the chip. In this paper, hot-carrier-induced degra- dation and gate-induced-drain-leakage curr- ent under worse case in P-MOSFET\`s have been studied. First of all, the degradation of gate-induced- drain-leakage current due to electron/hole trapping and surface electric field in off state MOSFET\`s which has appeared as an additional constraint in scaling down p-MOSFET\`s. The GIDL current in p-MOSFET\`s was decreased by hot-electron stressing, because the trapped charge were decreased surface-electric-field. But the GIDL current in n-MOS77T\`s under worse case was increased.

  • PDF

PNP 게이트를 가지는 폴리 실리콘 박막 트랜지스터의 전기적 특성 (Electrical characteristics of polysilicon thin film transistors with PNP gate)

  • 민병혁;박철민;한민구
    • 전자공학회논문지A
    • /
    • 제33A권3호
    • /
    • pp.96-106
    • /
    • 1996
  • One of the major problems for poly-Si TFTs is the large off state leakage current. LDD (lightly doped drain) and offset gated structures have been employed in order to reduce the leakage current. However, these structures also redcue the oN current significantly due to the extra series resistance caussed by the LDD or offset region. It is desirable to have a device which would have the properties of the offset gated structure in the OFF state, while behaving like a fully gated device in the oN state. Therefore, we propose a new thin film transistor with pnp junction gate which reduce the leakage curretn during the OFF state without sacrificing the ON current during the ON state.

  • PDF

공사 중 환기덕트 누풍 최소화를 위한 접속부 개발 및 성능평가 연구 (A study on the development and performance evaluation of duct coupling for the minimized leakage of temporary ventilation duct)

  • 조형제;전규명;민대기;김종원;백종훈
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.145-160
    • /
    • 2018
  • 초장대 해저터널은 환기를 위한 연직갱 또는 경사갱 설치에 공간적으로 많은 제한을 받게 되므로 일부 인공섬을 건설하여 환기를 수행할 필요가 있다. 그러나 인공섬 설치는 건설의 어려움뿐만 아니라 건설비용이 증가하게 되므로 인공섬 설치를 최소화할 필요가 있다. 이에 따라 환기거리가 증가하여 누풍에 의한 공급 풍량이 커지게 되면, 공사 중 환기를 위한 덕트 설치가 불가능해지거나 팬 정압 및 동력이 상당히 증가하게 된다. 따라서 초장대 해저터널을 건설하기 위해서는 이러한 현실적인 문제를 극복하고 시공 중 터널 내 환경을 쾌적한 상태로 유지할 수 있는 기술력이 필요하다. 선행 연구에서 우리는 누풍이 이 문제들을 해결하는 핵심 인자이며 실험 결과 새로운 접속방식의 누풍율은 대략 $1.46mm^2/m^2$임을 밝혔다(Jo et al., 2017). 본 연구에서는 새로운 접속방식이 적용된 시제품의 누풍율 측정 결과를 제시하고 기존 접속방식의 누풍 성능 개선을 위해 덕트 내부에 연질막 적용시의 누풍 성능 개선을 실험적으로 분석하였다.