• Title/Summary/Keyword: leakage power

Search Result 1,421, Processing Time 0.026 seconds

원전용 안전등급 밸브의 용접부 누설 클램핑 현장보수 기술 검토 (Preliminary Review of On-Site Clamping Repair Technology for Welding Part Leakage of Safety Related Valve in the Nuclear Power Plant)

  • 김기홍;김기수;정환석;장무경
    • 한국압력기기공학회 논문집
    • /
    • 제19권1호
    • /
    • pp.52-59
    • /
    • 2023
  • The welding part of the valve needs immediate action when leakage occurs due to cracks or damage. In order to repair leakage of the welding part, the valve must be separated from the pipe or replaced with a new valve. However, it is difficult to remove the valve while operating the power plant. This study presents a method to remove leakage by precisely processing the gap between the clamp and the incision part within 0.1mm while installed in the pipe system. If the external leakage is removed using a clamp on the welding part without removing the valve during operation, the time and cost required for maintenance can be reduced.

LLC 공진형 컨버터의 설계 (Design Consideration of LLC resonant converter)

  • 최항석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.50-52
    • /
    • 2006
  • This paper presents design consideration for LLC resonant converter utilizing the leakage inductance and magnetizing inductance of transformer as resonant components. The leakage inductance in the transformer secondary side is also considered in the gain equation. The design procedure is verified through experimental results.

  • PDF

A Study on Salt Damage Pollution Forecasting by Measuring Leakage Current

  • Lee, Dae-Dong;Hyun, Dong-Seok;Kim, Young-Dal
    • 조명전기설비학회논문지
    • /
    • 제24권7호
    • /
    • pp.47-56
    • /
    • 2010
  • Faults due to salt damage prevent the provision of stable power supply because they affect large areas and require much time and man power for recovery. Korea, three sides of which are surrounded by sea, is especially exposed to the impact of sea winds and typhoons. Therefore, salt damage to power facilities is one of the greatest problems of Korea's power system. To prevent salt damage pollution of insulators, the salt damage deposit on the insulators is regularly measured, and the insulators are washed when their salt damage deposits are expected to reach a critical level. When salt is detected on the insulators, however, errors are likely to occur according to different workers and environments. Therefore, a leakage current measurement method was proposed in this study to check the salt damage pollution level and reduce these errors.

잡음영향의 저감을 위한 두 디지털 필터들의 사용에 의한 DFT 기반의 계통주파수 추정 (DFT-based Power System Frequency Estimation using Two Digital Filters for Noise Effect Reduction)

  • 황진권
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.891-897
    • /
    • 2013
  • The power system frequency plays an important role in monitoring and controlling the power system. The frequency can be measured through discrete Fourier transform (DFT) coefficients of its positive fundamental frequency. The accuracy of the frequency estimate is severely affected by noise in the power system signal and the leakage effect of the negative fundamental frequency in DFT. This paper proposes a DFT-based frequency estimation algorithm to cope with the noise as well as the leakage effect. In this algorithm, two suitable digital filters are introduced to reduce efficiently frequency estimate error due to the noise. These filters are designed to use a digital bandpass filter and a second-degree integrator. The effectiveness of the proposed algorithm in reduction of frequency estimate error is verified through simulations on noise, harmonics and frequency deviation.

경년에 따른 배전용 피뢰기의 열화특성 (Characteristics analysis of field aged distribution surge arresters)

  • 조성수;김주용;김찬영;송일근;박중신
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2323-2325
    • /
    • 1999
  • This paper presents characteristics of the aged and new 18kV surge arresters. In order to investigate aging characteristics, we measured total leakage current and resistive leakage current using specially made leakage current measurement system and also investigated $tan{\delta}$ of the arresters and microstructure of the elements. Through the investigation we found that all of the arresters does not aged for 2 years field operation.

  • PDF

모바일기기의 동작모드와 대기모드를 모두 고려한 저전력 3차원 그래픽 가속기 (A Low Power 3D Graphics Accelerator Considering Both Active and Standby Modes for Mobile Devices)

  • 김영식
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제34권2호
    • /
    • pp.57-64
    • /
    • 2007
  • 본 논문에서는 모바일 3D 그래픽 가속기의 저전력 텍스쳐 캐쉬 구조를 제안하였다. 모바일 3D 그래픽 가속기는 동작모드에서 대규모 메모리 접근이 필요한 텍스쳐 매핑의 메모리 지연시간을 감소하고 대기모드에서 누설 전력소비를 줄이는 것이 매우 중요하다. 제안하는 텍스쳐 캐쉬 구조는 응용 프로그램의 텍스쳐 필터링 알고리즘에 따라서 가변적인 전력 모드 전환 기준으로 동작하여 누설전력을 줄이고 동작시간의 이득을 얻는다. 제안한 구조의 성능 검증을 위하여 트레이스 기반 텍스쳐 캐쉬 시뮬레이션을 수행하여 누설전력과 수행시간을 모두 고려한 성능 척도에서 이전 연구인 MSA 캐쉬보다 최대 7%의 성능 이득을 얻었다.

DAB 컨버터용 전력 변압기의 누설 인덕턴스를 포함한 내부 전력 손실 분석에 관한 연구 (A Study on the Analysis of Internal Power Loss Including Leakage Inductance of Power Transformer for DAB Converter)

  • 유정상;안태영;길용만
    • 반도체디스플레이기술학회지
    • /
    • 제21권2호
    • /
    • pp.95-100
    • /
    • 2022
  • In this paper, a power loss analysis technique of a high-frequency transformer of a bidirectional DAB (Dual Active Bridge) converter is reported. To miniaturize the transformer of the dual active bridge converter, a resonant inductor was designed with an air gap included low-coupled rate state core to combine leakage inductor with the resonant inductor which is required for soft-switching. In this paper, leakage inductance and magnetizing inductance, core material, type of winding and winding method are included in the dual active bridge transformer loss analysis process to enable optimal design at the initial design stage. Transformer loss analysis for dual active bridge with a switching frequency of 200 kHz and maximum output of 5 kW was executed, and elements necessary for design based on the number of turns on the primary side were graphed while maintaining the transformer turns ratio and window area. In particular, it was possible to determine the optimal number of turns and thickness of the transformer, and ultimately, the total loss of the transformer could be estimated.

시퀀셜 회로를 위한 리키지 최소화 입력 검색방법 (Low Leakage Input Vector Searching Techniques for Sequential Circuits)

  • 이성철;신현철;김경호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.655-658
    • /
    • 2005
  • Due to reduced device sizes and threshold voltages, leakage current becomes an important issue in CMOS design. In a CMOS combinational logic circuit, the leakage current in the standby state depends on the state of the inputs and thus can be minimized by applying an optimal input when the circuit is idling. In this paper, we present a New Input Vector Control algorithm, called Leakage Minimization by Input vector Control (LMIC) for minimal leakage power. This algorithm finds the minimal leakage vector and reduces leakage current up to 22.% on the average, for TSMC 0.18um process parameters. Minimal leakage vectors are very useful in reducing leakage currents in standby mode of operation.

  • PDF

용해성물질과 비용해성물질로 인공 오손된 송전용 애자의 누설전류 특성 (Characteristics of Leakage Current on Transmission Insulators Contaminated Artificially with Soluble and Nonsoluble Materials)

  • 최인혁;최장현;이동일;김찬영
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권9호
    • /
    • pp.464-469
    • /
    • 2004
  • The leakage current of transmission insulators contaminated with salt, clay, and kaolin was examined in the Gochang's Long Periods Testing Center. The Insulators were artificially contaminated and estimated with the method of equivalent salt deposit density(ESDD). The artificially contaminated insulators were installed with the same condition as in the real transmission power line and applied with 154 (kV). The leakage current of the artificially contaminated insulators was measured with environment conditions, such as temperature and humidity by the a automatic leakage current detecting system. The leakage current of heavily contaminated insulator was abruptly increased above 72[%] of humidity, even though the leakage current was similar between the contaminated and non-contaminated insulators below 72[%] of humidity. Also, it was found that the humidity was much more important than the temperature in the leakage current of transmission insulators. The leakage current of contaminated insulator was decreased when it was plenty of rainfall, resulting from natural washing.

축사 규모별 누전성분 특성 분석 (Analysis of Characteristic for Electric Leakage Component at Stable Size)

  • 김성철;김두현
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.54-58
    • /
    • 2012
  • This paper is purposed to analyze electric leakage component which can prevent electrical fires on breaker capacity expansion and power failure by operation of ELB(Earth leakage breaker) for stable sizes. In order to analysis for electric leakage component for stable sizes, this paper studied field state investigation which are at stable companies( 10 companies) in cheong-won location to deduce the problems of electric leakage component is analyzed. The field state experiment method is measured with electric leakage component which load part of ELB detected by electric loads(electrical fan, lighting, auto waterer, feeder and halogen lighting) and stable sizes. Results show that electric leakage component suggested in this paper are valuable and usable to electrical fire in leakage current based on environment factor, which will prevent severe damage to human beings and properties and reduce the electrical fires in stable.