• Title/Summary/Keyword: leakage power

Search Result 1,421, Processing Time 0.033 seconds

Analysis of Leakage Inductance for Toroidal Type Flyback Transformer (토로이달 타입 플라이백 변압기의 누설 인덕턴스 해석)

  • Park, Chang-Soo;Kang, Byeong-Geuk;Shin, Kyoung-Gu;Chung, Se-Kyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.164-172
    • /
    • 2014
  • This paper presents an analysis of a leakage inductance for a toroidal type flyback transformer. The equation to calculate the leakage inductance is derived using the MMF diagram of the transformer. The analysis for the different types of the cores and winding structures is also provided using the FEM simulation. The winding structures minimizing the leakage inductance are finally discussed from the simulation and experimental results.

In-Process Diagnosis of Servovalve Wear using Leakage Flow Measurement (누설 유량 계측에 의한 서보밸브 마멸의 인-프로세스 진단)

  • Kim K.H.;Han G.S.;Lee J.C.;Ham Y.B.;Kim S.D.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.2
    • /
    • pp.1-7
    • /
    • 2004
  • In-process diagnosis is essential to achieve predictive maintenance in industrial plants. An in- process diagnosis method was proposed for hydraulic servo systems, which was based upon leakage flow measurement. Leakage due to servovalve wear was analysed and modeled mathematically far computer simulation work. The key idea of diagnosis algorithm is that when monitoring signals, such as servovalve input and load displacement are in steady states, the return-line flow of hydraulic servo systems can be regarded as null-leakage of servovalve. Virtual experiments were performed to ensure effectiveness of the proposed diagnosis method.

  • PDF

Sub-1.2-V 1-Gb Mobile DRAM with Ultra-low Leakage Current (극저 누설전류를 가지는 1.2V 모바일 DRAM)

  • Park, Sang-Kyun;Seo, Dong-Il;Jun, Young-Hyun;Kong, Bai-Sun
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.433-434
    • /
    • 2007
  • This paper describes a low-voltage dynamic random-access memory (DRAM) focusing on subthreshold leakage reduction during self-refresh (sleep) mode. By sharing a power switch, multiple iterative circuits such as row and column decoders have a significantly reduced subthreshold leakage current. To reduce the leakage current of complex logic gates, dual channel length scheme and input vector control method are used. Because all node voltages during the standby mode are deterministic, zigzag super-cutoff CMOS is used, allowing to Preserve internal data. MTCMOS technique Is also used in the circuits having no need to preserve internal data. Sub-1.2-V 1-Gb mobile DDR DRAM employing all these low-power techniques was designed in a 60 nm CMOS technology and achieved over 77% reduction of overall leakage current during the self-refresh mode.

  • PDF

Electrical Properties of Wet Bars in Water-cooled Generator Stator Windings (흡습된 수냉각 발전기 고정자 권선의 전기적 특성)

  • Kim, Byeong-Rae;Kim, Hee-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.10
    • /
    • pp.817-823
    • /
    • 2012
  • Insulation breakdown of water-cooled generator stator windings occurs frequently due to leakage of cooling water and absorption into the insulation material. Leakage and absorption problems of water-cooled stator windings are often found during regular preventive maintenance. To evaluate cooling water leakage and absorption, diagnostic tests were performed on two water-cooled turbine generators, which have been in service for 13 and 17 years, respectively. The test results of the measured electrical properties such as dissipation factor($tan{\delta}$), capacitance and AC leakage current for water-cooled generator stator windings with wet bars are reported in this paper.

Leakage Monitoring of Control Valves for Nuclear Power Plants Using Multi-measuring (Multi-measuring기법을 이용한 원전 제어밸브의 누설진단)

  • Kim, Sung-Young;Kim, Young-Bum;Kim, Bong-Ho;Lee, Sang-Guk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3458-3463
    • /
    • 2007
  • Leakage would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leakage at present are analysis of ${\Delta}$T, AE(Acoustic Emission) analysis, and thermal image. The result for test of AC (Main steam) system in YNG 2 Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leakage is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So I think that using the Multi-Measuring method is more sound judgment than Single-Measuring method.

  • PDF

Study on the Correlation of Leakage by the Variation of Inlet Pressure and Clearance in Hydrostatic Bearing (정압베어링에서 입구압력 및 틈새간격 변화에 따른 누설량의 상관관계에 관한 연구)

  • Yun, Chung-Kug;Bae, Kang-Youl;Jeoun, Jin-Seong
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.34-39
    • /
    • 2016
  • This paper is the numerical study on the correlation of leakage by the variation of inlet pressure and clearance in hydrostatic bearing. The main goal of this study is to apply to the design of hydro system the results that the pocket pressure and the leakage rate according to the inlet pressure and the clearance between piston and cylinder tube. Because the hydrostatic bearing in hydraulic cylinder has the narrow rectangular channel between piston and cylinder tube, so to verify the numerical scheme, it has been compared with the experimental results of Brackbill and Kandlikar. The pressure data of numerical results inside narrow rectangular channel correlate was showed a good agreement with experimental results, thereby the numerical scheme was applied to the real model that is a hydraulic cylinder with the hydrostatic bearing. In conclusion, the pressure differences between inlet and pocket were shown within 3%. Leakage rates were showed rapidly increased pattern between about 4.5 and 6.7 times because the section area to calculate the leakage rates were proportioned to a square of diameter. The correlation equation was calculated among the inlet pressure, the clearance and the leakage rate by using the linear regression.

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

Deterioration Characteristics of ZnO Surge Arrester Blocks for Power Distribution Systems Due to Impulse Currents (임펄스전류에 의한 배전용 ZnO 피뢰기 소자의 열화특성)

  • Lee, Bok-Hee;Cho, Sung-Chul;Yang, Soon-Man
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.79-86
    • /
    • 2013
  • In order to analyze the electrical performance of ZnO surge arresters stressed by the combined DC and AC voltages that are generated in DC/AC converter systems, the leakage current properties of ZnO surge arrester blocks deteriorated by impulse currents were investigated. The test specimens were deteriorated by the 8/$20{\mu}s$ impulse current of 2.5kA and the leakage currents flowing into the deteriorated zinc oxide(ZnO) arrester blocks subjected to the combined DC and power frequency AC voltages are measured. As a result, the leakage currents flowing through deteriorated ZnO surge arrester blocks were higher than those flowing through the fine ZnO surge arrester blocks and the larger the injection number of 8/$20{\mu}s$ impulse current of 2.5kA is, the greater the leakage current is. The leakage current-voltage curves(I-V curves) of the fine and deteriorated ZnO surge arrester blocks stressed by the combined DC and AC voltages show significant difference in the low conduction region. Also the cross-over phenomenon is observed at the voltage close to the knee of conduction on plots of I-V curves.

Machine-Learning Based Optimal Design of A Large-leakage High-frequency Transformer for DAB Converters (누설 인덕턴스를 포함한 DAB 컨버터용 고주파 변압기의 머신러닝 활용한 최적 설계)

  • Eunchong, Noh;Kildong, Kim;Seung-Hwan, Lee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.6
    • /
    • pp.507-514
    • /
    • 2022
  • This study proposes an optimal design process for a high-frequency transformer that has a large leakage inductance for dual-active-bridge converters. Notably, conventional design processes have large errors in designing leakage transformers because mathematically modeling the leakage inductance of such transformers is difficult. In this work, the geometric parameters of a shell-type transformer are identified, and finite element analysis(FEA) simulation is performed to determine the magnetization inductance, leakage inductance, and copper loss of various shapes of shell-type transformers. Regression models for magnetization and leakage inductances and copper loss are established using the simulation results and the machine learning technique. In addition, to improve the regression models' performance, the regression models are tuned by adding featured parameters that consider the physical characteristics of the transformer. With the regression models, optimal high-frequency transformer designs and the Pareto front (in terms of volume and loss) are determined using NSGA-II. In the Pareto front, a desirable optimal design is selected and verified by FEA simulation and experimentation. The simulated and measured leakage inductances of the selected design match well, and this result shows the validity of the proposed design process.

Experimental Estimation on Magnetic Friction of Superconductor Flywheel Energy Storage System

  • Lee, Jeong-Phil;Han, Sang-Chul;Park, Byeong-Choel
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.124-128
    • /
    • 2011
  • This study estimated experimentally the loss distribution caused by magnetic friction in magnetic parts of a superconductor flywheel energy storage system (SFES) to obtain information for the design of high efficiency SFES. Through the spin down experiment using the manufactured vertical shaft type SFES with a journal type superconductor magnetic bearing (SMB), the coefficients of friction by the SMB, the stator core of permanent magnet synchronous motor/generator (PMSM/G), and the leakage flux of the metal parts were calculated. The coefficients of friction by the stator core of PMSM/G in case of using Si-steel and an amorphous core were calculated. The energy loss by magnetic friction in the stator core of PMSM/G was much larger than that in the other parts. The level of friction loss could be reduced dramatically using an amorphous core. Energy loss by the leakage magnetic field was small. On the other hand, the energy loss could be increased under other conditions according to the type of metal nearby the leakage magnetic fields. In manufactured SFES, the rotational loss by the amorphous core was approximately 2 times the loss of the superconductor and leakage. Moreover, the rotational loss by the Si-steel core is approximately 3~3.5 times the loss of superconductor and leakage.