• 제목/요약/키워드: leakage power

검색결과 1,421건 처리시간 0.027초

온도에 따른 ZnO 피뢰기 소자의 누설전류의 온도의존성 (Temperature dependent characteristics of leakage currents of ZnO blocks)

  • 이복희;이수봉;이봉;김동성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1572-1573
    • /
    • 2006
  • This paper presents electrical properties of Zinc Oxide(ZnO) surge arrester blocks under the power frequency AC voltages and various temperatures. The leakage current, $I_{R}-V$ curios and power dissipation for the fine and aged ZnO surge arrester blocks were measured as a function of the temperatures and applied voltages. When the temperature is increased from $50\;[^{\circ}C]$ to $150\;[^{\circ}C]$, the total leakage current significantly increased at the sane applied voltage level. Also, the resistive leakage currents and power dissipation were increased with increasing temperature. The leakage current and power dissipation of the aged ZnO arrester blocks were higher than the fine ZnO arrester blocks.

  • PDF

음향 영상화기법을 이용한 발전용 밸브 유체누설평가 연구 (A Study on the Fluid Leakage Evaluation for Power Plant Valve Using Acoustic Imaging Technique)

  • 이상국;이선기;김대웅
    • 동력기계공학회지
    • /
    • 제15권1호
    • /
    • pp.18-23
    • /
    • 2011
  • Image processing has provided powerful techniques to extract from the acoustic signals the desired information on evaluation for leakage existence, leakage rate, and searching for leakage location, etc. The imagery NDE data available can add additional and significant dimension in nondestructive evaluation(NDE) information and thus for exploiting in applications. To extract such information the use of advanced image processing techniques is much needed. In recent years, there has been much increased use of acoustic signal image processing techniques in acoustic NDE. This approach will increase the efficiency of inspection procedures and reduce inspection time. In this paper we are concerned only with This paper is concerned mainly with the use of advanced image processing techniques in valve leakage detection and advanced image restoration and enhancement methods, which attempt to evaluate promptly by a visualization method the acoustic sources while detecting the valve leakage.

Client Collaboration for Power and Interference Reduction in Wireless Cellular Communication

  • Nam, Hyungju;Jung, Minchae;Hwang, Kyuho;Choi, Sooyong
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제1권2호
    • /
    • pp.117-124
    • /
    • 2012
  • A client collaboration (CC) system is proposed for a user relay system. The proposed scheme focuses on the management of transmit power and leakage interference. In the proposed CC system, edge users transmit signals to the masters considered as user relays. The masters relay the signals of the edge users to the base station using the resource blocks (RBs) that are assigned to the edge users. The leakage interference and power consumption were analyzed in the CC system. In addition, an optimal master location problem was formulated based on the signal-to-leakage-plus-noise ratio (SLNR). Because the optimal master location problem is quite complex, a sub-optimal master location problem was proposed and a closed-form sub-optimal master location was obtained. The edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC. The numerical results showed that the edge users generate smaller leakage interference and power consumption in the proposed CC system compared to the system without the CC, and the average throughput increases.

  • PDF

누설전류 파고분석에 의한 전력설비의 열화진단 기술 (Deterioration Diagnostic Techniques for Power Facilities by Analyzing Pulse-Height of leakage current)

  • 한주섭;김명진;손원진;길경석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 추계종합학술대회
    • /
    • pp.367-370
    • /
    • 2001
  • 본 논문에서는 누설전류 파고분석을 이용한 전력선비의 새로운 열화 진단법을 제안하였다. 현재까지 여러가지 열화 진단법이 제안되었으며, 평가요소로 누설전류의 크기만을 이용하는 것이 일반적이었다. 본 연구에서는 피뢰기, 케이블 등의 전력설비들이 열화가 진전됨에 따라 누설전류의 파고분포도 크게 달라짐을 알 수 있었다. 따라서 전력설비의 열화진단에 누설전류의 파고분포를 이용하면 기존의 누설전류의 크기만을 이용하는 방법보다 더 정확한 평가가 가능하다. 피뢰기, 케이블을 이용한 여러 가지 적용실험으로부터 제안한 열화 진단법은 충분한 성능이 있음을 확인하였다.

  • PDF

3레벨 태양광 PCS에서의 누설전류 저감기법 개발 (Development of Leakage Current Reduction Method in 3-Level Photovoltaic PCS)

  • 한성은;조종민;안현성;차한주
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.56-61
    • /
    • 2019
  • In this study, a reduction method of leakage current in a three-level photovoltaic power-conditioning system (PCS) is proposed and verified by simulation and experiment. Leakage current generation is analyzed through an equivalent model of the common mode voltage considering a significant parasitic capacitance existing between the photovoltaic array and ground. A leakage current reduction method using pulse-width modulation (PWM) method is also proposed, and a 10-kW three-level photovoltaic PCS simulation and experiment is performed with a $1{\mu}F$ parasitic capacitor based on 100 nF/kW. The proposed method using the PWM method is verified to reduce the leakage current by 73% compared with the conventional PWM method.

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

누설전류측정에 의한 피뢰기 열화진단에 있어 전원고조파의 영향 (Influence of Harmonics in Power System Voltage on Arrester Deterioration Diagnostics by Leakage Current Measurement)

  • 길경석;한주섭;주문노
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.42-46
    • /
    • 2003
  • Arresters are deteriorated by overvoltages or impulse currents, and the resistive leakage current of arresters increases as the deterioration of the arrester progresses, showing an increase in the 3$^{rd}$ harmonic component of the leakage current. In this reason, arrester diagnostic techniques based on the 3$^{rd}$ harmonic leakage current as a reference parameter of deterioration are widely used. The technique, however, includes an error due to the harmonics of power system voltage. Therefore, the influence of the harmonics on arrester diagnostics should be considered. In this paper, we designed a PSpice ZnO arrester model to simulate the influence of the voltage harmonics described above. A pure sinusoidal voltage and its the 3r harmonic voltage were applied to the model, and the leakage current components were analyzed. From the simulation results, it is confirmed that the peak value of resistive leakage current depends not only on the phase of the 3$^{rd}$ harmonic voltage but also on the magnitude of it. Consequently, the errors caused 1)y the harmonic voltage could be minimized by correcting the magnitude of leakage current upon analyzing the harmonics.cs.

Relative humidity prediction of a leakage area for small RCS leakage quantification by applying the Bi-LSTM neural networks

  • Sang Hyun Lee;Hye Seon Jo;Man Gyun Na
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1725-1732
    • /
    • 2024
  • In nuclear power plants, reactor coolant leakage can occur due to various reasons. Early detection of leaks is crucial for maintaining the safety of nuclear power plants. Currently, a detection system is being developed in Korea to identify reactor coolant system (RCS) leakage of less than 0.5 gpm. Typically, RCS leaks are detected by monitoring temperature, humidity, and radioactivity in the containment, and a water level in the sump. However, detecting small leaks proves challenging because the resulting changes in the containment humidity and temperature, and the sump water level are minimal. To address these issues and improve leak detection speed, it is necessary to quantify the leaks and develop an artificial intelligence-based leak detection system. In this study, we employed bidirectional long short-term memory, which are types of neural networks used in artificial intelligence, to predict the relative humidity in the leakage area for leak quantification. Additionally, an optimization technique was implemented to reduce learning time and enhance prediction performance. Through evaluation of the developed artificial intelligence model's prediction accuracy, we expect it to be valuable for future leak detection systems by accurately predicting the relative humidity in a leakage area.

콘센트용 누전감지 모듈 개발 (Development of the Leakage Current Detection Module for a Concent)

  • 한영오
    • 한국전자통신학회논문지
    • /
    • 제8권3호
    • /
    • pp.447-452
    • /
    • 2013
  • 본 연구에서는 콘센트용 누설전류 감지 및 자동차단 모듈을 개발하였다. 제안된 누설전류 검출 모듈은 저항성 누설전류 검출 칩을 사용한 콘센트용 누설전류 검출 모듈과는 차별화된, 전력 프로세서인 MSP430 MCU(Micro Controller Unit)를 이용하여 합성 누설전류에서 저항성 누설전류를 프로그램으로 분리 검출한다. 제안된 방법으로 구현된 모듈은 저항성 누설전류 5mA 이상에서 조기 검출 및 자동차단 기능이 있을 뿐만 아니라, 저항성 누설전류 검출 기능이 프로그램으로 구현되어 있어 저항성 누설전류 5mA 이하 또는 이상으로도 쉽게 조정이 가능한 장점이 있다.

누설전류로 인한 전기화재 및 감전사고 예방기법 (Prevention Techniques of Electrical Fire and Electrical Shock Caused by Leakage Current)

  • 김동우;임용배;이상익;김재현;강대철
    • 조명전기설비학회논문지
    • /
    • 제27권6호
    • /
    • pp.82-87
    • /
    • 2013
  • Electrical leakage happens when faults in electrical apparatus or power lines occur. It causes electrical fires and electric shocks. In order to reduce accidents caused by electrical leakage current, it is important to detect faults effectively and shut off the power. In this paper, firstly we analyzed statistics of electrical fires and electric shocks caused by electrical leakage current. Secondly, standards of allowable leakage current and body impedance models were analyzed. Lastly, effective application methods for breaking electrical leakage current were suggested. The results will provide useful preventive measures of electrical fires and electric shocks caused by electrical leakage.