• 제목/요약/키워드: leakage power

검색결과 1,421건 처리시간 0.025초

원전 격납건물 누설시험용 무선데이터전송을 적용한 시험장치 개발 (Leakage Rates Measurement System Development of NPP Primary Containment using Wireless Data Communication Method)

  • 류재규;손창호;황희정;김건수;최경식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.916-919
    • /
    • 2003
  • In this paper, we deal with a development of measurement system to apply the leakage rates test of primary containment in nuclear power plant. The measurement test about leakage rates in primary containment is one sort of test to prove safety of nuclear power plant. The parameters which are measured to calculate leakage rates are drybulb temperature, dew point temperature(or relative humidity), absolute pressure and flow. Overall, the measurement system consists of sensor module for data acquisition of the parameters, transfer module for wireless data communication and control module to control system and to calculate leakage rates. Because existing measurement systems are difficult to set in field, we pursued convenience of use, we applied wireless data communication and individual form module using battery. We also changed for the better in confidence. Recently, we are developing a drybulb temperature and a dew point temperature sensor module. We describe about function of developed measurement system, its standard and an plan for verification of measurement system.

  • PDF

부하종류에 따른 회로의 누설전류 및 절연저항 특성 연구 (Study on Characteristics of Leakage Current and Insulation Resistance for a Circuit According to Load Types)

  • 한경철;최용성
    • 전기전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.364-369
    • /
    • 2019
  • 본 논문에서는 전기재해를 일으킬 수 있는 요소를 미리 제거하기 위해 전등부하, 전열부하, 동력부하를 대상으로 누설전류와 절연저항을 측정하여 분포비율과 누적비율을 비교하고 분석하여 보다 효과적이고 신뢰성 있는 누설전류 검출방법을 찾고자 하였다. 누설전류와 절연저항의 적합 비율 차이는 전열부하 32.5%, 전등부하 22.8%, 동력부하 2.2%의 순으로 나타났으며, 누설전류계가 낮은 적합 비율을 나타내었으며, 누설전류계는 측정방법에 따른 오차와 용량성 누설전류 및 영상전류가 포함되어 있기 때문으로 생각되었다.

Effects of Carrier Leakage on Photoluminescence Properties of GaN-based Light-emitting Diodes at Room Temperature

  • Kim, Jongseok;Kim, Seungtaek;Kim, HyungTae;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • 제3권2호
    • /
    • pp.164-171
    • /
    • 2019
  • Photoluminescence (PL) properties of GaN-based light-emitting diodes (LEDs) were analyzed to study the effects of carrier leakage on the luminescence properties at room temperature. The electrical leakage and PL properties were compared for LEDs showing leakages at forward bias and an LED with an intentional leakage path formed by connecting a parallel resistance of various values. The leakages at the forward bias, which could be observed from the current-voltage characteristics, resulted in an increase in the excitation laser power density for the maximum PL efficiency (ratio of PL intensity to excitation power) as well as a reduction in the PL intensity. The effect of carrier leakages on PL properties was similar to the change in PL properties owing to a reduction of the photovoltage by a reverse current since the direction of the carrier movement under photoexcitation is identical to that of the reverse current. Valid relations between PL properties and electrical properties were observed as the PL properties deteriorated with an increase in the carrier leakage. The results imply that the PL properties of LED chips can be an indicator of the electrical properties of LEDs.

Dependence of Na+ leakage on intrinsic properties of cation exchange resin in simulated secondary environment for nuclear power plants

  • Hyun Kyoung Ahn;Chi Hyun An;Byung Gi Park;In Hyoung Rhee
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.640-647
    • /
    • 2023
  • Material corrosion in nuclear power plant (NPP) is not controlled only by amine injection but also by ion exchange (IX) which is the best option to remove trace Na+. This study was conducted to understand the Na+ leakage characteristics of IX beds packed with ethanolamine-form (ETAH-form) and hydrogen-form (H-form) resins in the simulated water-steam cycle in terms of intrinsic behaviors of four kinds of cation-exchange resins through ASTM test and Vanselow mass action modeling. Na+ was inappreciably escaped throughout the channel created in resin layer. Na+ leakage from IX bed was non-linearly raised because of its decreasing selectivity with increasing Na+ capture and with increasing the fraction of ETAH-form resin. Na+ did not reach the breakthrough earlier than ETAH+ and NH4+ due to the increased selectivity of Na+ to the cation-exchange resin (H+ < ETAH+ < NH4+ ≪ Na+) at the feed composition. Na+ leakage from the resin bed filled with small particles was decreased due to the enhanced dynamic IX processes, regardless of its low selectivity. Thus, the particle size is a predominant factor among intrinsic properties of IX resin to reduce Na+ leakage from the condensate polishing plant (CPP) in NPPs.

PWM 인버어터로 구동되는 유도 전동기의 고주파 누설전류 모델링 및 억제에 관한 연구 (A Study on Modeling and Damping of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor)

  • 이재호;전진휘;홍정표;강필순;박성준;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 연구회 합동 학술발표회 논문집
    • /
    • pp.18-22
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high frequency leakage current that flows through stray capacitor between stator windings and a motor frame to ground. This paper presents an equivalent circuit for high frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit. A conventional common mode ckoke or reactor in series between the ac terminals of a PWM inverter and those of an ac motor is not effective to reduce the rms and average values of the leakage current, but effective to reduce the peak value. Furthermore, this paper proposes a leakage current damper which is different in damping principle from the conventional common mode choke. It is shown theoretically and experimentally that the leakage current damper is able to reduce the rms value of the leakage current to 25%, where the core used in the leakage current damper is smaller than that of the conventional common-mode choke

  • PDF

해밍 웨이트 누출 기반 ARIA 키 확장 SPA (A Simple Power Analysis Attack on ARIA Key Expansion Based on Hamming Weight Leakage)

  • 박애선;한동국;최준
    • 정보보호학회논문지
    • /
    • 제25권6호
    • /
    • pp.1319-1326
    • /
    • 2015
  • AES, ARIA와 같은 대칭키 암호 알고리즘은 각 라운드 마다 사용되는 라운드 키를 키 확장 메커니즘을 통해 생성한다. 이러한 키 확장 메커니즘이 실행 될 때 소비되는 전력은, 비밀키에 대한 정보를 보유하고 있다는 점에 기인하여, 소수의 전력 파형을 이용한 단순전력분석으로 비밀키의 후보를 현저하게 감소시킬 수 있는 취약점이 존재한다. 그러므로, 이러한 공격에 대한 연구 분석을 통해, 정보 누출을 막을 수 있는 대응방법의 연구가 시급한 실정이다. 국제 표준 암호인 AES의 키 확장 SPA에 대한 연구는 2002년 이후 현재까지 진행되고 있으나, 국내에서 많은 분야에 응용되고 있는 국내 표준 암호 알고리즘 ARIA에 대한 키 확장 SPA 연구의 진행은 미흡하다. 이에 본 논문에서는, 마스킹이 적용되어 있지 않은 ARIA-128 버전 8비트 구현시 키 확장 SPA 공격 시나리오를 제안하고, 실험을 통해 ARIA가 해밍 웨이트 누출 기반 키 확장 SPA 공격에 취약함을 보인다.

MTCMOS Post-Mask Performance Enhancement

  • Kim, Kyo-Sun;Won, Hyo-Sig;Jeong, Kwang-Ok
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제4권4호
    • /
    • pp.263-268
    • /
    • 2004
  • In this paper, we motivate the post-mask performance enhancement technique combined with the Multi-Threshold Voltage CMOS (MTCMOS) leakage current suppression technology, and integrate the new design issues related to the MTCMOS technology into the ASIC design methodology. The issues include short-circuit current and sneak leakage current prevention. Towards validating the proposed techniques, a Personal Digital Assistant (PDA) processor has been implemented using the methodology, and a 0.18um process. The fabricated PDA processor operates at 333MHz which has been improved about 23% at no additional cost of redesign and masks, and consumes about 2uW of standby mode leakage power which could have been three orders of magnitude larger if the MTCMOS technology was not applied.

ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석 (Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

Novel Dual DC-DC Flyback Converter with Leakage-Energy Recycling

  • Yang, Lung-Sheng
    • Journal of Power Electronics
    • /
    • 제18권4호
    • /
    • pp.1007-1014
    • /
    • 2018
  • A novel dual DC-DC flyback converter with leakage-energy recycling is presented in this paper. Only an active switch is used for this converter. A pulse-width-modulation strategy is adopeted to control this switch. Two transformers are employed for the proposed converter. During the switch ON-period, the primary windings of the two transformers store energies. At the switch OFF-period, the energies stored in the primary windings of the two transformers are released to the output via the secondary windings of the two transformers. Meanwhile, the leakage energies of the two transformers can be recycled. The operating principles and steady-state analyses of the proposed converter are described in detail. A prototype circuit of the proposed converter is implemented for verifying the performances.

광파이버 누수센싱 시스템 개발에 관한 연구 (A Study on the Development of Optical-Fiber Water Leakage Sensing System)

  • 김영복
    • 동력기계공학회지
    • /
    • 제16권6호
    • /
    • pp.86-91
    • /
    • 2012
  • A multi purpose environmental monitoring system has been developed as a commercially available standard using the techniques which are FBG(Fiber Bragg Grating), Hetero-core spliced fiber optic sensor and etc, for the purposes of monitoring large scaled structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition in view of the full scaled operation at actual sites to be monitored. Additionally, the developed systems in the previous works conveniently provided us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. In this paper, we extend the previous results to a water leakage detection problem and develop a sensing system as a result. By the experimental study, it is verified that multi-point leakage detection is possible using single line optical fiber.