• Title/Summary/Keyword: leakage inductance of transformer

Search Result 158, Processing Time 0.02 seconds

An Analysis on the Characteristics of the Contact-less Power Supply (무접점 전원장치의 특성분석)

  • Lee, Hyun-Kwan;Lee, Gi-Sik;Chung, Bong-Geun;Kang, Sung-In;Kong, Young-Su;Kim, Eun-Soo;Kim, Yoon-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.919-922
    • /
    • 2006
  • Comparing with the conventional transformer without the air gap, a contact-less transformer with the large air-gap (4.8cm) between the long primary winding and the secondary winding has the increased leakage inductance and the reduced magnetizing inductance. By the increased leakage inductance and the reduced magnetizing inductance on the primary of the contact-less transformer, a good deal of the primary current circulates through magnetizing inductance, which results in a massive loss in contact-less power supply (CPS). In this paper, the efficiency characteristics of the contact-less power supply using a series resonant converter is analyzed and simulated. The results are verified on the simulation based on the theoretical analysis and the 1.8kW experimental prototype.

  • PDF

A utilization of PCB capacitor to reduce the output voltage ripple in Flyback SMPS (PCB 캐패시터를 이용한 플라이백 SMPS 출력 리플 저감 대책)

  • Kim T.G.;Chung G.B.;Lee W.Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.102-105
    • /
    • 2003
  • The leakage inductance of the High frequency Transformer(HFT) in the flyback topology can be used an inductor of the Low Pass Filter(LPF) to reduce ripple and ripple noise in the output voltage. But, the values of leakage inductance and magnetizing inductance in the HFT are within $\pm20[{\%}]$). And the operating temperature of the HFT increased by the leakage inductance. Therefore, the leakage inductance of the HFT in the flyback topology has minimum and the LPF has non-polarity ceramic capacitor in the output stage. In this paper, the LPF in the flyback topoBogy takes PCB capacitor using double layer of PCB without non-polarity ceramic capacitor. Its experimental results show the reduced ripple noise and the reduced ripple in the output stage.

  • PDF

Enhanced Switching Pattern to Improve Energy Transfer Efficiency of Active Cell Balancing Circuits Using Multi-winding Transformer (다중권선 변압기를 이용한 능동형 셀 밸런싱 회로의 에너지 전달 효율을 높이기 위한 향상된 스위칭 패턴)

  • Lee, Sang-Jung;Kim, Myoungho;Baek, Ju-Won;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.4
    • /
    • pp.279-285
    • /
    • 2019
  • This study proposes an enhanced switching pattern that can improve energy transfer efficiency in an active cell-balancing circuit using a multiwinding transformer. This balancing circuit performs cell balancing by transferring energy stored in a specific cell with high energy to another cell containing low energy through a multiwinding transformer. The circuit operates in flyback and buck-boost modes in accordance with the energy transfer path. In the conventional flyback mode, the leakage inductance of the transformer and the stray inductance component of winding can transfer energy to an undesired path during the balancing operation. This case results in cell imbalance during the cell-balancing process, which reduces the energy transfer efficiency. An enhanced switching pattern that can effectively perform cell balancing by minimizing the amount of energy transferred to the nontarget cells due to the leakage inductance components in the flyback mode is proposed. Energy transfer efficiency and balancing speed can be significantly improved using the proposed switching pattern compared with that using the conventional switching pattern. The performance improvements are verified by experiments using a 1 W prototype cell-balancing circuit.

An Improved High Efficiency Resonant Converter for the Contactless Power Supply with a Low Coupling Transformer (낮은 커플링 변압기를 갖는 비접촉 전원의 개선된 고효율 공진 컨버터)

  • Kong Young-Su;Kim Eun-Soo;Lee Hyun-Kwan
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.1
    • /
    • pp.33-39
    • /
    • 2005
  • Comparing with the conventional transformer without the air gap, a contactless transformer with the large air gap between the long primary winding and the secondary winding has increased leakage inductance and reduced magnetizing inductance. For transferring the primary power to the secondary one, the high frequency series resonant converter has been widely used for the contactless power supply system with the large air gap and the increased leakage inductance of the contactless transformer However, the high frequency series resonant converter has the disadvantages of the low efficiency and high voltage gain characteristics in the overall load range due to the large air gap and the circulating magnetizing current. In this paper, the characteristics of the high efficiency and unit voltage gain are revealed in the proposed three-level series-parallel resonant converter. The results are verified on the simulation based on the theoretical analysis and the 5kW experimental prototype.

A Study on the Magnetic Field Analysis and Leakage Inductance in Current Transformers by 3D Integral Methods (3차원 적분법을 이용한 변류기의 자계해석과 누설 인덕턴스에 대한 연구)

  • 이희갑;박용필
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.768-772
    • /
    • 2001
  • This paper presents leakage magnetic field and leakage inductance calculations in current transformer by means of 3-D Integral methods. From the distribution diagram of leakage magnetic flux to be analyzed using program called TRACAL 3, ti confirms a parallel to the winding axis direction of the leakage flux lines in the air gap between the windings. The leakage inductances L$\sub$r1/ and L$\sub$r2/ of the primary and secondary winding were calculated, their values are 4.23 MH and 0.49 mH, respectively. They are also similar to the measured values of he leakage inductances of the experimental verification, 4.06 mH and 0.47 mH.

  • PDF

A Study on the Soft-Switching Forward-Flyback Converter Using Auxiliary Inductor and Auxiliary Diode (보조 인덕터와 보조 다이오드를 적용한 소프트-스위칭이 가능한 포워드-플라이백 컨버터에 관한 연구)

  • Lee, A-Ra;Park, Jun-Woo;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.2
    • /
    • pp.140-149
    • /
    • 2017
  • This study proposes a new type of active-clamp forward-flyback converter with two transformers that operate in forward and flyback modes during on and off times, respectively, instead of not using an output inductor. The main switch can be turned on with zero-voltage switching (ZVS) using the leakage inductance of the transformer and the output capacitor of the main switch. The leakage inductance should be increased to ZVS. However, the ringing between the leakage inductance of the transformer and the parasitic output capacitance of the secondary side rectifier switches results in a serious voltage spike. A forward-flyback converter employing auxiliary inductor and auxiliary diode is proposed to overcome the problem. The operational principles are analyzed in detail and validated through experiments with a 385 V-to-53 V/37 A prototype.

A Contactless Energy Transfer Circuit Using Coreless Low-profile PCB Transformer (코어없는 초박형 PCB 변압기를 이용한 무접점 전력변환 회로)

  • 최병조
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.505-508
    • /
    • 2000
  • A coreless printed circuit board(PCB) transformer is employed in a contactless energy transfer circuit that achieves an efficient power conversion at the presence of a considerable airgap between the source and the load side. A half-bridge series resonant converter is selected as the contactless energy transfer circuit in order to minimize the detrimental effects of large leakage inductance small magnetizing inductance and poor coupling coefficient of the coreless PCB transformer. The operation and performance of the proposed contactless power converter are verified on a 7 W experimental circuit that provides an 18V/0.4A output from a 210-370 V input source.

  • PDF

Simple High Efficiency Full-Bridge DC-DC Converter using a Series Resonant Capacitor

  • Jeong, Gang-Youl;Kwon, Su-Han;Park, Geun-Yong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.100-108
    • /
    • 2016
  • This paper presents a simple high efficiency full-bridge DC-DC converter using a series resonant capacitor. The proposed converter achieves the zero voltage switching of the primary switches under a wide range of load conditions and reduces the high circulating current in the freewheeling mode using the leakage resonant inductance and the series resonant capacitor. Thus, the proposed converter overcomes the drawbacks of the conventional full-bridge DC-DC converter and improves its overall system efficiency. Its structure is simplified by using the leakage inductance of the transformer as the resonant inductance and omitting the DC output filter inductance. Also it can operate over a wide range of input voltages. In this paper, the operational principle, analysis and design example are described in detail. Finally, the experimental results from a 650W (24V/27A) prototype are demonstrated to confirm the operation, validity and features of the proposed converter.

Phase Shift Full Bridge Converter for Sever Power using a New Separated Leakage Inductor Winding (SLW) Method

  • Cho, Kyu-Min;Kim, Young-Do;Cho, In-Ho;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.517-519
    • /
    • 2008
  • A new transformer winding method is proposed in this paper. Generally, PWM ZVS topologies use a leakage inductor to achieve ZVS operation. However, the leakage inductance of the transformer is not often enough to meet ZVS condition. Therefore, an additional leakage inductor is necessary, which causes large core loss because high input voltage is applied to the additional leakage inductor during a short commutation period. In this paper, a new separated leakage inductor winding (SLW) method is proposed. With the proposed winding method, a leakage inductor and a transformer can be combined in one ferrite core. Therefore, size and core loss of the additional leakage inductor can be reduced. Experimental results demonstrate that the proposed winding method can achieve a significant efficiency improvement in a 1210.8W (12V, 100.9A) prototype converter.

  • PDF

Analysis and Design of Quadruple-Active-Bridge Converter Employing Passive Power Decoupling Capability (수동 전력 비동조화가 가능한 QAB 컨버터의 분석과 설계에 관한 연구)

  • Yun, Chang-Woo;Lee, Jun-Young;Baek, Ju-Won;Jung, Jee-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.2
    • /
    • pp.157-164
    • /
    • 2022
  • This study proposes an enhanced quadruple-Active-Bridge (QAB) converter that can solve power coupling problems. By adopting a multiple winding transformer, the equivalent circuit of a conventional QAB converter has power couplings between arbitrary output ports. This coupling is an unintended power relationship that complicates the regulation of output voltage of the multiple ports. The proposed converter can carry out power decoupling by changing the arrangement of the coupling inductor. Power transfer equations for the proposed converter and its operating principles are analyzed in detail. The power coupling caused by the transformer's leakage inductance is verified by using a proposed coupling factor that presents the relationship between inductance ratio and coupling power. In addition, the decoupling power control performance of the proposed converter is verified by simulation and a 3 kW prototype converter.