• Title/Summary/Keyword: leakage detector

Search Result 105, Processing Time 0.025 seconds

X-ray Response Characteristic of Zn in the Polycrystalline Cd1-xZnxTe Detector for Digital Radiography

  • Kang, Sang-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.2
    • /
    • pp.28-31
    • /
    • 2002
  • The Cdl-xZnxTe film was fabricated by thermal evaporation for the flat-panel X-ray detector. The stoichimetric ratio and the crystal structure of a polycrystalline Cd$_{1-x}$ Zn$_{x}$Te were investigated by EPMA and XRD, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in the polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$_{0.7}$Zn$_{0.3}$Te thin film were measured to 0.37 nA/cm$^2$ and 260 pc/cm$^2$ at an applied voltage of 2.5 V/${\mu}{\textrm}{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$_{1-x}$ Zn$_{x}$Te detectors reduced the leakage current and improved the signal to noise ratio significantly.

A Polycrystalline CdZnTe Film and Its X-ray Response Characteristics for Digital Radiography

  • Kim, Jae-Hyung;Park, Chang-Hee;Kang, Sang-Sik;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.5
    • /
    • pp.15-18
    • /
    • 2003
  • The Cd$\_$1-x/Zn$\_$x/Te film was produced by thermal evaporation for the flat-panel X-ray detector. The crystal structure and the surface morphology of poly crystalline Cd$\_$1-x/Zn$\_$x/Te film were examined using XRD and SEM, respectively. The leakage current and X-ray sensitivity of the fabricated films were measured to analyze the X-ray response characteristic of Zn in a polycrystalline CdZnTe thin film. The leakage current and the output charge density of Cd$\_$0.7/Zn$\_$0.3/Te thin film were measured to 0.3 1nA/$\textrm{cm}^2$ and 260 pC/$\textrm{cm}^2$ at an applied voltage of 2.5 V/$\mu\textrm{m}$, respectively. Experimental results showed that the increase of Zn doping rates in Cd$\_$1-x/Zn$\_$x/Te detectors reduced the leakage current and improved the X-ray sensitivity significantly. The leakage current was drastically diminished by the formation of thin parylene layer in the Cd$\_$0.7/Zn$\_$0.3/Te detector.

A Study on the Wedge shape Detector of Very High Resolution Positron Emission computer Tomography (초고해상도 양전자 방출 CT의 쐐기형 검출기에 관한 연구)

  • 이행세;이태원
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.2
    • /
    • pp.44-54
    • /
    • 1985
  • The high resolution of positron emission tomography, in particular, requires the use of detector crystals of narrow width but still with sufficiently high detection efficiency. If the crystal width is reduced to several millimeters, degradation of detection efficiency and leakage coefficient becomes significant, particularly in case of obliquely incident photons. Alleviation of such a problem can be made possible by modification of the detector shape from the conventional rectangular type to a wed농e type. The Proposed wedge shape makes the absorption length longer for obliquely incident photons, thus increasing the detection efficiency and suppressing leakage coefficient. For the BGO detectors of 4-8mm width, the computer simulation result of the system using wedge detectors reveals resolution improvement to the system using conventional detectors. For the system composed of 200 BGO detectors of 8mm width with 2 point sampling motion, the simulation resolution system using conventional detectors. For the very high resolution system of 3-7mm FWHM, the characteristics of the detector shape and size is studied by computer simulation.

  • PDF

The characteristic study of hybrid X-ray detector using ZnS:Ag phosphor (ZnS:Ag phosphor를 이용한 hybrid 형 X-ray detector 특성 연구)

  • Park, Ji-Koon;Gang, Sang-Sik;Lee, Dong-Gil;Cha, Byeong-Yeol;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.27-30
    • /
    • 2002
  • Photoconductor for direct detection flat-panel imager present a great materials challenge, since their requirements include high X -ray absorption, ionization and charge collection, low leakage current and large area deposition. Selenium is practical material. But it needs high thickness and high voltage in selenium for high ionization rate. We report comparative studies of detector sensitivity. One is an a-Se with $70{\mu}m$ thickness on glass. The other has hybrid layer of depositting ZnS phosphor with $100{\mu}m$ on a-Se. The leakage current of hybrid is similar to it of a-Se, but photocurrent is lager than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF

Development of Multi Channel Gas Leakage Detector for Large Facility (대규모 시설을 위한 다채널 가스 누설 경보기 개발)

  • Jeong, Kyu-Won
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.1-7
    • /
    • 2008
  • As a clean fuel, LNG or LPG is widely used in large restaurants or plants instead of coal. These fuels are easy to use and cheap. However, they are inflammable very much and easily exploded at the worst. So there are many laws and regulations legislated for the handling and usage of the gas facilities. Nevertheless, very harsh explosions occurred in several domestic or foreign places. In this paper a gas detection and alarm system was developed for large facilities. A new concept for connecting many gas detectors was proposed and based upon that a system including hardware and software have been developed and tested. Although up to 16 gas detectors apart 1 km from main controller can be connected currently, this system can be easily expanded for more detectors because each gas detector receiver communicates with main controller using industrial standard RS-485 multi drop technique. Furthermore several additive functions was included for the installation and maintenance convenience.

The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Amorphous Selenium (비정질 셀레늄의 누설전류 저감을 위한 다층구조 제작 및 특성 평가)

  • Park, J.K.;Kang, S.S.;Suk, D.W.;Lee, H.W.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.849-852
    • /
    • 2002
  • Recently, amorphous selenium is used as x-ray conversion material for flat-panel x-ray detector. In this paper, we investigated the effect of breakdown under high voltage and leakage current in PN-type multi-layer structure based on p-type a-Se and n-type conductive thin film. Experimental results show that the multi-layer based detector reduced leakage current because n-type CeO2 conductive layer prevent from hole injection into a-Se layer from collection electrode, Also, the breakdown voltage was improved by dielectric layer between a-Se and top electrode.

  • PDF

Development of Wireless Real-Time Gas Detector System for Chemical Protection Performance Test of Personal Protective Equipment (화생방 보호의 성능평가를 위한 무선 실시간 가스 검출기 개발)

  • Kah, Dong-Ha
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.294-301
    • /
    • 2020
  • Man-In-Simulant Test(MIST) provides a test method to evaluate chemical protective equipments such as protective garments, gloves, footwear and gas mask. The MIST chamber is built to control concentration of chemical vapor that has a activity space for two persons. Non-toxic methyl-salicylate(MeS) is used to simulate chemical agent vapor. We carried out to measure inward leakage MeS vapors by using passive adsorbent dosimeter(PAD) which are placed on the skin at specific locations of the body while man is activity according to the standard procedure in MIST chamber. But more time is required for PADs and there is concern of contamination in PADs by recovering after experiment. Therefore detector for measuring in real time is necessary. In order to analyze in real time the contamination of the personal protective equipment inside the chemical environment, we have developed a wireless real-time gas detector. The detector consists of 8 gas-sensors and 1 control-board. The control-board includes a CPU for processing a signal, a power supply unit for biasing the sensor and Bluetooth-chipset for transmission of signals to external PC. All signals from gas-sensors are converted into digital signals simultaneously in the control-board. These digital signals are stored in external PC via Bluetooth wireless communication. The experiment is performed by using protective equipment worn on manikin. The detector is mounted inside protective equipment which is capable of providing a real-time monitoring inward leakage MeS vapor. Developed detector is demonstrated the feasibility as real-time detector for MIST.

Fabrication and Characterization of Array Type of Single Photon Counting Digital X-ray Detector (Array Type의 Single Photon Counting Digital X-ray Detector의 제작 및 특성 평가)

  • Seo, Jung-Ho;Lim, Hyun-Woo;Park, Jin-Goo;Huh, Young;Jeon, Sung-Chea;Kim, Bong-Hui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.32-32
    • /
    • 2008
  • X-ray detector는 의료용, 산업용 등 다양한 분야에서 사용되어지고 있으며 기존의 Analog X-ray 방식의 환경오염, 저장공간 부족, 실시간 분석의 어려움 등의 문제점들을 해결하기 위하여 Digital X-ray로의 전환과 연구가 활발하며 이에 따른 관심도 높아지고 있는 살점이다. Digital X-ray detector는 p-영역과 n-영역 사이에 아무런 불순물을 도핑하지 않은 진성반도체(intrinsic semiconductor) 층을 접합시킨 이종접합 PIN 구조의 photodiode 이다. 이 소자는 역바이어스를 가해주면 p영역과 n영역 사이에서 캐리어 (carrier)가 존재하지 않는 공핍 영역이 발생하게 된다. 이런 공핍 영역에서 광흡수가 일어나면, 전자-정공 쌍이 발생한다. 그리고, 발생한 전자-정공 쌍에 전압이 역방향으로 인가되는 경우, 전자는 양의 전극으로 이동하고, 정공은 음의 전극으로 이동한다. 이와 같이, 발생한 캐리어들을 검출하여 전기적인 신호로 변환 시킨다. 고해상도의 Digital X-ray detector를 만들기 위해서는 누설전류에 의한 noise 감소와 소자의 높은 안정성과 내구성을 위한 높은 breakdown voltage를 가져야 한다. 본 연구에서는 Digital X-ray detector의 leakage current 감소와 breakdown voltage를 높이기 위하여 guradring과 gettering technology를 사용하여 전기적 특성을 분석하였다. 기판으로는 $10k\Omega{\cdot}cm$ resistivity를 갖으며, n-type <111>인 1mm 두께의 4인치 Si wafer를 사용하였다. 그리고 pixel pitch는 $100{\mu}m$이며 active area는 $80{\mu}m{\times}80{\mu}m$$32\times32$ array를 형성하여 X-ray를 조사하여 소자의 특성을 평가 하였다.

  • PDF

DetGas: A Carbon Monoxide Gas Leakage Detector Mobile Application

  • Kamaruddin, Farhan Fikri Mohd;Hadiana, Ana;Lokman, Anitawati Mohd
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.11
    • /
    • pp.59-66
    • /
    • 2021
  • Many incidents of Carbon Monoxide (CO) poisoning have occurred because of people being unaware of its presence. There are currently available systems on the market, but they are limited to measuring CO in a certain area and lack vital functions. Additionally, little to no evidence-based information on their quality was available. Thus, a mobile application for detecting CO gas leakage in a vehicle and critical features to assist victims was developed. A usability and functionality test were conducted to determine the product's quality utilizing nine usability and six functionality task scenarios (n=5). Then, a System Usability Scale test was performed to obtain system satisfaction, usability, and learnability (n=50). The usability and functionality test shows that all the tasks given for both tests were 100% successful. The overall score obtained for SUS was 71.4, which indicates good acceptance and usability. Around 20% of respondents claimed that they would need the support of a technical person to be able to use the application and that they needed to learn a lot of things before they could use the application, which indicates the overall high learnability of the application. The result provides empirical evidence that the CO gas leakage detection mobile application is successful and receives good usability, functionality, acceptability, learnability, and satisfaction assessments. DetGas could benefit automobile owners and other stakeholders by mitigating the risk and harm associated with gas leaking that exceeds the safe limit.

The High Voltage Research of X-ray Detector Based on Amorphous Selenium (a-Se 기반의 X선 검출기에서의 고전장 간섭 연구)

  • Cha, Byung-Youl;Kang, Sang-Sik;Cho, Sung-Ho;Lee, Gyu-Hong;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.853-856
    • /
    • 2002
  • Present. direct method x-ray conversion detector is studied by abroad medical instrument and country with amorphous Selenium. And we search the method for large area x-ray detector. Amorphous-Selenium based photoreceptor is widely used on the X-ray conversion materials. But amorphous-selenium based x-ray conversion detector is broken by high voltage and leakage defect point. In this paper, We investigated top-electrode distance rate to improve defect point and high voltage broken. The result to appoint to made large area x-ray conversion detector with base data.

  • PDF