• Title/Summary/Keyword: leakage checking

Search Result 47, Processing Time 0.032 seconds

A Study on Dry and Wet Wipe Test for Radioisotope Leakage Checking (방사성동위원소 누설 점검을 위한 건식 및 습식 문지름 시험법 연구)

  • Park, SangMin;Yoo, SeungHee;Choi, KyuSeok;Lee, HwaHyung;Hong, Sayong
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.305-312
    • /
    • 2018
  • A dry and wet wipe test for radioisotope leakage checking was conducted by fixing the radioisotope $^{14}C$ to the glass surface and used for observing the transfer factor and surface shape of the test paper through wipe test. The dry wipe test showed that transfer factor in the tissue paper was twice as high as in the paper filter, and the wet wipe test showed that transfer factor in the paper filter paper was three times higher than the tissue paper. Although paper filters are general choice for leakage checking, it has been shown that tissue paper can be an alternative in the dry wipe test.

Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter (스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발)

  • Jung-Hoon Kim;Jung-Suk Oh;Jin-Han Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.2
    • /
    • pp.57-64
    • /
    • 2023
  • As the meter reading method of gas meters develops, smart gas meters capable of remote meter reading (leak checking meters and multi-function safety meters) are being used. These meters have a function to judge leakage by utilizing the flow rate and pressure data collected as an additional function. Leakage judgment function using flow rate data has valid cases in the actual field, but the pressure data-based leakage judgment standard is based on not only the pressure value change due to leakage but also various factors (pressure regulator pressure, connection with adjacent meters, usage of adjacent houses, location of meters, etc.). There is a problem with pressure magnitude changes (levels). In this paper, as a technique that can judge leaks by using pressure data collected from smart gas meters, it was developed through preprocessing of pressure data, criteria for pressure value ranges related to leaks, leak judgment techniques, and application case verification.

Experimental Investigation of Thermal Stress Cracks in Mechanical Face Seals (기계평면시일의 열응력 크랙에 관한 실험적 연구)

  • 김청균
    • Tribology and Lubricants
    • /
    • v.12 no.3
    • /
    • pp.79-84
    • /
    • 1996
  • One of the greatest dangers in mechanical face seals is the formation of heat checking and thermal stress cracks on the sliding surfaces. These thermal distortions due to non-uniform heating lead to increase the leakage of the sealed fluids and wear, and with balance of the seal can cause the seal faces to part. In this study heat checking and thermal stress cracks are investigated experimentally. These thermal distortions are explained using the thermal models of the conatct geometries between the seal ring and the seal seat. To overcome these thermal problems, the thermohydrodynamic seal is presented. The newly developed mechanical seal may substantially reduce the friction torque, frictional heating which causes heat checking and thermal stress cracks, and wear.

A Study on the characteristics of degradation sensor for insulation oil (절연유(絶緣油) 열화(劣化)센서 특성(特性) 연구(硏究))

  • Chon, Y.K.;Sun, J.H.;Kang, D.S.;Joo, B.S.;Yoon, J.Y.;Chung, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1371-1374
    • /
    • 1995
  • It is well known that the degradation of transformer oil conseqently lead to the failure of transformer. This paper discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor is composed of base ring, electrodes and porous ceramic, passed through the transformer oil and checks the transformer oil condition through sensor's leakage current. So it is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts the characteristics of V-T-I and DC 2 KV and other examinations were performed. It is verified that ionized transformer oil caused by the expansion of temperature increases in the leakage current of porous ceramic sensor. It is certification that the leakage current of other parts of porous ceramic is very small(about 2%) compared with the porous ceramic body and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences (위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Jeong, Yong Wook
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

A study on the characteristics of degradation sensor for transformer insulation oil (변압기(變壓器) 절연유(絶緣油) 열화(劣化)센서의 특성연구(特性硏究))

  • Chon, Y.K.;Sun, J.H.;Kang, D.S.;Kim, M.D.;Kweon, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1765-1768
    • /
    • 1996
  • It is well known that the degradation transformer oil is mainly effected to the failure of transformer. In this paper it is discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor composed with base ring, electrodes and porous ceramic passed through the transformer oil and checked the transformer oil condition with sensor's leakage current. It is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts it is examined the characteristics of V-T-I and DC 2 KV and other examinations. It is verified that ionized transformer caused by the expansion of oil temperature increase in the leakage current of porous ceramic sensor. It is certificated that the leakage current of other parts of porous ceramic is very small (about 2 %) than the porous ceramic and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF

Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles (은나노입자에 대한 방진마스크 포집효율 및 총누설율)

  • Kim, Jong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

The Evaluation of Hydrogen Leakage Safety for the High Pressure Hydrogen System of Fuel Cell Vehicle (연료전지자동차의 고압수소저장시스템 수소 누출 안전성 평가)

  • Kim, Hyun-Ki;Choi, Young-Min;Kim, Sang-Hyun;Shim, Ji-Hyun;Hwang, In-Chul
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.316-322
    • /
    • 2012
  • A fuel cell vehicle has the hydrogen detection sensors for checking the hydrogen leakage because it use hydrogen for its fuel and can't use a odorant to protect the fuel cell stack. To verify the hydrogen safety of leakage we select the high possible leak points of fittings in hydrogen storage system and test the leaking behavior at them. The hydrogen leakage flow rate is 10, 40, 118 NL/min and the criterion for maximum hydrogen leakage is based on allowing an equivalent release of combustion energy as permitted by gasoline vehicles in FMVSS301. There are total 18EA hydrogen leakage detection sensors installed in test system. we acquire the hydrogen leakage detection time and determine the ranking. Hydrogen leakage detection time decrease when hydrogen leakage flow rate increase. The minimum hydrogen leakage detection time is about 3 seconds when the flow rate is 118NL/min. In this study, we optimize hydrogen sensor position in fuel cell vehicle and verify the hydrogen leakage safety because there is no inflow inside the vehicle.

A Study on the Evaluation Method of Water Leakage Repair in Polyacrylic Resin (폴리 아크릴 레진의 누수 보수 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.223-224
    • /
    • 2017
  • In this study, various materials such as epoxy material, urethane material, cement material, and acrylic material are used to solve the water leakage occurring in underground structures. However, in the reality that the durability is insufficient and the effect is insufficient, it is aimed to improve the repairing effect by using cement and acrylics in combination. As a first study, we tried to verify the performance of improve the performance by checking the product properties according to the composition ratio of polyacrylic resin. Polyacrylic resin is evaluated in three different composition ratios. When the material is selected for polyacrylic resin, it is applied to the field to understand the maintenance effect and durability.

  • PDF

A Blocking Distribution Channels to Prevent Illegal Leakage in Supply Chain using Digital Forensic

  • HWANG, Jin-Hee
    • Journal of Distribution Science
    • /
    • v.20 no.7
    • /
    • pp.107-117
    • /
    • 2022
  • Purpose: The scope of forensic investigations serves to identify malicious activities, including leakage of crucial corporate information. The investigations also identify security lapses in available networks. The purpose of the present study is to explore how to block distribution channels to protect illegal leakage in supply chain through digital forensic method. Research design, data and methodology: The present study conducted the qualitative textual analysis and its data collection process entails five steps: identifying and collecting data, determining coding categories, coding the content, checking validity and reliability, and analyzing and presenting the results. This methodology is a significant research method due to its high quality of previous resources. Results: Applying previous literature analysis to the results of this study, the author figured out that there are four solutions as an evidences to block distribution channels, preventing illegal leakage regarding company information. The following subtitles show clear solutions: (1) Communicate with Stakeholders, (2) Preventing and addressing illegal leakage, (3) Victims of Data Breach, (4) Focusing Solely on Technical Teams. Conclusion: There are difficult scenarios that continue to introduce difficult questions surrounding engagement with digital evidence. Consequently, it is important to enhance data handling to provide answers for organizations that suffer due to illegal leakages of sensitive information.