• 제목/요약/키워드: leak location detection system

검색결과 26건 처리시간 0.017초

가속도계를 이용한 상수도 배관의 누수위치 식별연구 (Pinpointing of Leakage Location of Water Pipelines using Accelerometers)

  • 이영섭;윤동진;정중채
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.821-826
    • /
    • 2003
  • Leaks in underground pipelines can cause social, environmental and economical problems. One of a good contermeasures of leaks Is to find and repair of leak points of pipes. Leak noise is a good source to identify the location of leak points of pipelines. Although there have been several methods to detect the leak location with leak noise, such as listening rods, hydrophones or ground microphones, they were not so efficient tools beca. In this paper, two accelermeters are used to detect leak locations which could provide an easier and efficient method. The filtering, signal processing and algorithm is described for the detection of leak location. A 120m-long pipeline system for experiment is installed and the results with the system show that the algorithm with the two accelerometers gives very accurate pinpointing of leaks. Theoretical analysis of sound wave propagation speed in underground pipes is also described.

  • PDF

음향방출기법을 이용한 열교환기 누설검출시스템 개발 (Development of Leak Detection System of Heat Exchanger using Acoustic Emission Technique)

  • 이민래;이준현
    • 대한기계학회논문집A
    • /
    • 제26권5호
    • /
    • pp.864-871
    • /
    • 2002
  • Acoustic emission(AE) technique has been applied to not only mechanical property testing but also on-line monitoring of the entire structure or a limit zone only. Although several AE devices have already been developed for on-line monitoring, the price of these systems is very high and it is difficult for the field to apply yet. In this study, we developed a specially designed PC-based leak detection system using A/D board. In this paper, AE technique has been applied to detect leak for heat exchanger by analyzing the characteristics of signal obtained from leak. It was confirmed that the characteristics of the signal generated by the turbulence of gas in the heat exchanger is narrow band signal having between 130-250kHz. Generally, the amplitude of leak signal is increased as the leak size increasing, but showed no significant change at frequency characteristic. Leak source location can be found by determining for the paint of highest signal amplitude by comparing with several fixed sensors. In this paper, AE results are compared with the PC-based leak detection system using A/D board.

매설배관 내의 압축성 유체 누설 위치 검출에 관한 연구 (A Study on the Compressible Fluid Leak Position Detection of Buried Pipelines)

  • 이정한;김형진;윤두병;박진호
    • 한국가스학회지
    • /
    • 제20권5호
    • /
    • pp.40-49
    • /
    • 2016
  • 지하 매설배관을 이용한 유체 수송 중 임의의 배관 위치에서 누설이 발생할 경우 육안 식별의 어려움으로 진동 센서 등을 이용하여 누설 위치를 탐지한다. 이러한 누설 위치 검출 시스템은 물과 같은 비 압축성 유체를 대상으로 센서 간의 신호 도달 시간차와 음파의 전파속도를 이용하여 검출하고 있다. 본 논문에서는 가스와 같은 압축성 유체의 누설 검출을 위한 시스템을 개발하고자 기존 검출 방법을 검토하고, 온도와 압력을 고려한 압축성 유체의 전파속도 식을 개선하고 압축 공기를 이용한 실험 장치를 구축하여 실험 수행을 통해 검증하였다. 검증 결과 매설배관 내 압축성 유체의 누설 위치 검출이 가능함을 확인하였으며, 가스 수송용 매설배관 내 누설 위치 검출 시스템 개발에 적용 가능함을 확인하였다.

A leak detection and 3D source localization method on a plant piping system by using multiple cameras

  • Kim, Se-Oh;Park, Jae-Seok;Park, Jong Won
    • Nuclear Engineering and Technology
    • /
    • 제51권1호
    • /
    • pp.155-162
    • /
    • 2019
  • To reduce the secondary damage caused by leakage accidents in plant piping systems, a constant surveillance system is necessary. To ensure leaks are promptly addressed, the surveillance system should be able to detect not only the leak itself, but also the location of the leak. Recently, research to develop new methods has been conducted using cameras to detect leakage and to estimate the location of leakage. However, existing methods solely estimate whether a leak exists or not, or only provide two-dimensional coordinates of the leakage location. In this paper, a method using multiple cameras to detect leakage and estimate the three-dimensional coordinates of the leakage location is presented. Leakage is detected by each camera using MADI(Moving Average Differential Image) and histogram analysis. The two-dimensional leakage location is estimated using the detected leakage area. The three-dimensional leakage location is subsequently estimated based on the two-dimensional leakage location. To achieve this, the coordinates (x, z) for the leakage are calculated for a horizontal section (XZ plane) in the monitoring area. Then, the y-coordinate of leakage is calculated using a vertical section from each camera. The method proposed in this paper could accurately estimate the three-dimensional location of a leak using multiple cameras.

An improved cross-correlation method based on wavelet transform and energy feature extraction for pipeline leak detection

  • Li, Suzhen;Wang, Xinxin;Zhao, Ming
    • Smart Structures and Systems
    • /
    • 제16권1호
    • /
    • pp.213-222
    • /
    • 2015
  • Early detection and precise location of leakage is of great importance for life-cycle maintenance and management of municipal pipeline system. In the past few years, acoustic emission (AE) techniques have demonstrated to be an excellent tool for on-line leakage detection. Regarding the multi-mode and frequency dispersion characteristics of AE signals propagating along a pipeline, the direct cross-correlation technique that assumes the constant AE propagation velocity does not perform well in practice for acoustic leak location. This paper presents an improved cross-correlation method based on wavelet transform, with due consideration of the frequency dispersion characteristics of AE wave and the contribution of different mode. Laboratory experiments conducted to simulate pipeline gas leakage and investigate the frequency spectrum signatures of AE leak signals. By comparing with the other methods for leak location identification, the feasibility and superiority of the proposed method are verified.

주파수 대역 변화를 이용한 배관의 누수지점 추정 개선 연구 (Improved Estimation of Leak Location of Pipelines Using Frequency Band Variation)

  • 이영섭;윤동진
    • 비파괴검사학회지
    • /
    • 제34권1호
    • /
    • pp.44-52
    • /
    • 2014
  • 스마트워터그리드 시스템의 지하 상수도 배관 관리에 있어서 누수는 중요한 요소인데, 특히 그 배관이 낡았고 인구가 많은 도시의 포장도로나 다양한 건축물의 아래에 매설된 경우이다. 이러한 누수지점의 정확한 탐지는 이들 배관의 효율적인 운용을 위해 필수적이기 때문에, 주파수 대역 변화, 창 필터 그리고 확률에 바탕한 새로운 누수지점 탐지 방법론을 본 논문을 통해 제안한다. 정확한 누수지점의 추정은 누수음에 의한 센서 신호간의 시간 지연 추정의 정확성에 따라 결정된다는 것이 알려져 있기 때문에 중요한 주파수에 가중치를 부여하는 몇 가지의 창 함수들이 개선된 상호상관함수를 계산하기 위해 적용되었다. 실제 주철로 제작된 길이 253.9 m의 지하매설 상수도 배관에 대해 새로운 방법론을 적용한 실험결과는 향상된 누수지점 탐지 성능을 보여 주었다.

누설영역 분석을 이용한 배관 증기누설 위치 추정 방법 (Location Estimation Method of Steam Leak in Pipelines Using Leakage Area Analysis)

  • 김세오;전형섭;손기성;박종원
    • 비파괴검사학회지
    • /
    • 제36권5호
    • /
    • pp.384-390
    • /
    • 2016
  • 플랜트 배관의 누설감시 시스템은 누설 유무 판단뿐만 아니라 누설의 위치를 신속히 파악하는 것 또한 매우 중요하다. 플랜트 배관의 누설 검출 방법에는 주로 AE(acoustic emission)센서, 마이크로폰어레이 그리고 카메라 영상을 이용한 방법들이 있다. 최근 광역감시 및 원거리감시의 이점이 있는 카메라 영상을 이용한 방법에 대한 연구가 진행되어 왔다. 하지만 기존 카메라 영상을 이용한 방법들은 누설 유무와 대략적인 누설의 위치를 판단하고 있으나 누설이 시작되는 정확한 위치 추정에 대한 연구는 아직 미흡한 상태이다. 따라서 본 논문에서는 카메라를 이용한 누설 검출 방법을 이용해 누설영역을 산출하고 누설 검출 결과를 분석하여 누설 위치를 추정하는 방법을 제안하였으며 실험을 통하여 성능을 평가하였다.

음향방출기법을 이용한 열교환기 누설 검출 시스템 개발 (Development of Leak Detection System of Heat Exchanger using Acoustic Emission Technique)

  • 이민래;이준현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.65-71
    • /
    • 2001
  • In this paper, acoustic omission technique(AE) has been applied to detect leak for heat exchanger by analyzing the characteristics of signal obtained from leak. It was confirmed that the characteristics of the signal generated by the turbulence of gas in the heat exchanger is narrow band signal having between 130-250KHz. Generally, the amplitude of leak signal is increased as the leak size increasing, but showed no significant change at frequency characteristic. Leak source location can be found by searching for the point of highest signal amplitude by comparing wi th several fired sensors.

  • PDF

상수도 배관에서 두 지점의 동시 누수에 따른 신호특징 분석 (Analysis on Signal Properties due to Concurrent Leaks at Two Points in Water Supply Pipelines)

  • 이영섭
    • 비파괴검사학회지
    • /
    • 제35권1호
    • /
    • pp.31-38
    • /
    • 2015
  • 스마트 워터 그리드와 같은 지하매설 상수도 배관망을 구성할 때 누수 지점에 대한 지능적 탐지는 중요한 요소이다. 이런 지능형 배관망의 구성에는 많은 수의 누수탐지센서를 일정한 간격으로 설치하는 것이 필요하며 이들 센서에서 계측되는 신호를 분석해서 누수 유무 및 누수발생시 그 지점의 추정을 신속히 할 수 있어야 한다. 그래서 본 연구에서는 특히 두 지점에서 동시에 누수가 발생하는 경우에 대해 그 센서가 측정한 신호가 가지는 특성 및 두 누수지점 동시 추정 가능성을 심도있게 분석하였다. 즉, 센서간 거리가 315.6 m 인 100A 사이즈의 주철관 상수도 배관에 대해 두 지점 동시 누수시 각각의 개별 센서신호를 계측하였으며, 그 신호를 기반으로 주파수 특성 및 상호상관함수 등의 분석을 통해 두 지점의 누수탐지에 대해 기술하였다.

주입 압력파의 웨이블릿 일관성 분석을 사용한 저수조-관로-밸브 시스템에서의 누수탐지모형 연구 (A scheme of leak detection model in a reservoir pipeline valve system using wavelet coherence analysis of injected pressure wave)

  • 고동원;이정섭;김진원;김상현
    • 상하수도학회지
    • /
    • 제35권1호
    • /
    • pp.15-25
    • /
    • 2021
  • In this study, a method of leakage detection was proposed to locate leak position for a reservoir pipeline valve system using wavelet coherence analysis for an injected pressure wave. An unsteady flow analyzer handled nonlinear valve maneuver and corresponding experimental result were compared. Time series of pressure head were analyzed through wavelet coherence analysis both for no leak and leak conditions. The leak information can be obtained through either time domain reflectometry or the difference in wavelet coherence level, which provide predictions in terms of leak location. The reconstructed pressure signal facilitates the identification of leak presence comparing with existing wavelet coherence analysis.