• Title/Summary/Keyword: lead metal

Search Result 1,166, Processing Time 0.028 seconds

A Study on Metal Expressed in Contemporary Fashion -Focusing on Women's Fashion in 1990s- (현대패션에 나타난 금속에 관한연구 -1990년대 여성복을 중심으로-)

  • 금기숙
    • Journal of the Korean Society of Costume
    • /
    • v.45
    • /
    • pp.161-178
    • /
    • 1999
  • In contemporary fashion metal have used which is as the material with a sufficient potentiality of expression which is displayed by an unique characteristic involved only in metal. In this paper metal expressed in contemporary fashion is researched. The first thing the formative characteristic of metal is researched under the consideration of type technique and color of metal used in contemporary fashion. Metals such as gold silver bronze aluminum thin lead and iron are usually used in fashion and those metals are used in various types such a thread fabric board leaf a and cable. Those types of metal as above are applied to the clothing by the techniques of weaving embroidering metal leaf printing or moulding which gives the formative characteristic to the clothing. In color metal has an effect on the colors of surroundings by its smooth and unique luster and its effect of reflection and produces the visual formative characteristic through the effects of contrast. The esthetic will of metal expressed in modern fashion is researched in this study under the facts studied as above. first metal expresses the future oriented esthetic Second metal has the characteristic of attracting the attention Third metal is used as valid techniques to express the artistic formation for clothing escaping from the idea that the clothing is only for wearing. Finally metal is used as an anti-cultural tool of fighting against the existing order or spirit.

  • PDF

Preparation of L-cysteine Salicylaldehyde Schiff-base Modified Macroporous Polystyrene Resin and Its Application to Determination of Trace Cadmium and Lead in Environmental Water Samples

  • Xie, Fazhi;Zhang, Fengjun;Xuan, Han;Ge, Yejun;Wang, Yin;Li, Guolian;Zhu, Lei;Oh, Won-Chun
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.5
    • /
    • pp.472-476
    • /
    • 2014
  • In this work, a new method that utilizes L-cysteine salicylaldehyde Schiff-base modified macroporous polystyrene resin (PS-CSC) as an effective sorbent has been developed for preconcentration of trace cadmium and lead in environmental water samples. The effect of pH, the contact time, the elution conditions, the flow rate, the initial concentration of target metal ions, and the effects of interfering ions on the preconcentration of the analytes were investigated. The maximum adsorption capacity of PS-CSC under optimum conditions for cadmium and lead were found to be 6.03 - 18.17 mg/g and 12.58 - 36.13 mg/g when the initial concentration of metal ions between 5.0 - 90 mg/L. The limits of detection for cadmium and lead were 2.46 ng/L and $0.52{\mu}g/L$, with a preconcentration factor of 200. The developed method has been validated by analyzing certified reference material and successfully applied for the enrichment and determination of trace cadmium and lead from environmental water samples.

Organobentonite as a dual sorbent for Chlombenzene and Lead (클로로벤젠과 납의 동시 제거를 위한 흡착제로서의 유기 벤토나이트에 관한 연구)

  • 이정주;박재우;김일규
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.41-50
    • /
    • 2001
  • The use of clay has been the favored method of reducing or eliminating hazardous contaminants in the leachate from landfills. But, neither natural clays nor organoclays modified with surfactants are able to effectively sorb both heavy metals and organic contaminants. Therefore, the objective of this study is to determine the optimal amount of surfactant added on the clay mineral to effectively remove both of them. For this purpose, Na-Bentonite as the natural clay, and hexadecyltrimethylammonium (HDTMA) as the cationic surfactant were used, Chlorobenzene and lead ($Pb^{2-}$) were selected as representative contaminants. Experimental result showed that chlorobenzene sorption increased with increasing HDTMA to bentonite, ratios. On the contrary, the removal rate of lead decreased as the amount of HDTMA increased. The removal of chlorobenzene was influenced by the amount of HDTMA added to the bentonites rather than initial concentration of chlorobenzene, but the removal of lead was much more influenced by the initial concentration of lead. The adsorption of lead was not affected by chlorobenzene, and vice versa. The competitive sorption between the heavy metal and the organic contaminant was not present.

  • PDF

A Study on Trace Metal Levels in Hair (모발중 미량 금속 함량에 관한 조사 연구)

  • Son, Busoon;Hong, Eunju;Kim, Yoonshin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.2
    • /
    • pp.233-244
    • /
    • 1997
  • In order to investigate the concentration of trace metals in human hairs from residents living in urban area and rural area, the 120 hair samples of adults were taken from urban areas(industrial area, bus terminal, downtown area) and rural area(Kasan-ri, Yeoju-up, Yeoju-goon) during July - September 1995. Mean concentrations of trace metals including lead and cadmium in human hair were compared by region, sex, presence of smoker, type of water, period of residence. The results were as follows; 1. The average concentrations of lead and cadmium in hairs of urban area are $0.92{\mu}g/g$ ($1.01{\mu}g/g$ industrial area, $1.01{\mu}g/g$ bus terminal, $0.74{\mu}g/g$ downtown area), $0.38{\mu}g/g$ ($0.54{\mu}g/g$ industrial area, $0.49{\mu}g/g$ bus terminal, $0.12{\mu}g/g$ downtown area). The mean concentrations of lead and cadmium in urban area are higher than the corresponding levels in the rural area. 2. Lead concentration for male in the urban and rural area is 0.94 and $0.62{\mu}g/g$, 0.90 and $0.60{\mu}g/g$ for female. But, It does not have any statistical significance. Cadmium concentration for male in the urban and rural area is 0.38 and $0.12{\mu}g/g$, 0.38 and $0.11{\mu}g/g$ for female. But It does not have any statistical significance. 3. Mean concentrations of lead and cadmium in smokers shows higher than non-smokers. It showed that the longer period of residence in urban area, the higher concentrations of three metals.

  • PDF

An Examination of the Characteristics and Manufacturing Techniques of Joseon-era Metal Bullets (조선시대 금속제 탄환의 특징과 제작기법 검토)

  • Choi, Bo Bae;Lee, Hye Jin;Kim, Myung Hoon;Jeong, Hyeon Jin
    • Conservation Science in Museum
    • /
    • v.28
    • /
    • pp.65-88
    • /
    • 2022
  • The characteristics and behavior of bullets are important because they are directly related to the firearm performance. However, research related to bullets have been small. In this paper, scientific analysis was conducted to find out the materials and manufacturing process of metal bullets during the Joseon Dynasty, owned by Korea Army Museum, and the types of firearms available were classified and organized according to the bullet diameter. As a result, bullets were classified into iron bullets, lead bullets, and lead-coated iron bullets. Most of the iron bullets and lead bullets were made from casting. Some iron bullets were made from forging. And the lead-coated iron bullet was made by pouring molten lead after putting the iron bullet into the mold. Finally, the bullets could be used for Hand Cannon, Matchlock Musket, Frankish Cannon, Hyeon-ja Cannon, Dae-Wiwon Cannon, Small Cannon, and Hong-Yi Cannon.

Characteristics of Heavy Metal Biosorption by Pseudomonas cepacia KH410 (Pseudomonas cepacia KH410의 중금속 흡착특성)

  • 박지원;김영희
    • Korean Journal of Microbiology
    • /
    • v.37 no.3
    • /
    • pp.197-203
    • /
    • 2001
  • An ubiquitous bacterium, Pseudomonar cepacia KH410 was isolated from fresh water plant root and identified. Adsorption of heavy metals of lead, cadmium and copper by this strain was investigated. Optimal conditions foradsorption was 1.0 dry g-biomass, at pH 4.0 and temperature of $40^{\circ}C$. Adsorption equilibrium reached max-imum after 120 min in 1000 mg/l metal solutions. The adsorption capacity (K) of lead was 5.6 times higher thancadmium and 4.0 times higher than that of copper. Adsorption of lead was applicable for Langmuir modelwhereas Freundlich model for cadmium and copper, respectively. Adsorption strength (1/n) of heavy metal ionswere in the order of lead>copper>cadmium. Uptake capacity of lead, cadmium and copper by dried cell was83.2,42.0,65.2 mg/g-biomass, respectively. Effective desorption was induced 0.1 M HCI for lead and 0.1 $HNO_3$ for cadmium and copper. Pretreatment to increase ion strength was the most effective with 0.1 M KOH.Uptake by immobilized cell was 77.8,58.5,71.2 mg/g-biomass for lead, cadmium and copper, respectively. Theimmobilized cell was more effective than ion exchange resin on removal of heavy metals in solution containinglight metals.

  • PDF

Numerical Analysis for Thermal-deformation Improvement in TSOP(Thin Small Outline Package) by Anti-deflection Adhesives (TSOP(Thin Small Outline Package) 열변형 개선을 위한 전산모사 분석)

  • Kim, Sang-Woo;Lee, Hai-Joong;Lee, Hyo-Soo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.20 no.3
    • /
    • pp.31-35
    • /
    • 2013
  • TSOP(Thin Small Outline Package) is the IC package using lead frame, which is the type of low cost package for white electronics, auto mobile, desktop PC, and so on. Its performance is not excellent compared to BGA or flip-chip CSP, but it has been used mostly because of low price of TSOP package. However, it has been issued in TSOP package that thermal deflection of lead frame occurs frequently during molding process and Au wire between semiconductor die and pad is debonded. It has been required to solve this problem through substituting materials with low CTE and improving structure of lead frame. We focused on developing the lead frame structure having thermal stability, which was carried out by numerical analysis in this study. Thermal deflection of lead frame in TSOP package was simulated with positions of anti-deflection adhesives, which was ranging 198 um~366 um from semiconductor die. It was definitely understood that thermal deflection of TSOP package with anti-deflection adhesives was improved as 30.738 um in the case of inside(198 um), which was compared to that of the conventional TSOP package. This result is caused by that the anti-deflection adhesives is contributed to restrict thermal expansion of lead frame. Therefore, it is expected that the anti-deflection adhesives can be applied to lead frame packages and enhance their thermal deflection without any change of substitutive materials with low CTE.

Metal Concentrations in Lungs of Coal Workers' Pneumoconiosis Patients (탄광부 진폐증자의 폐조직내 금속농도)

  • Choi, Ho Chun;Chung, Ho Keun;Kim, Hae Jeong;Chun, Hyang Sook;Yi, Gwan Hyeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.1 no.1
    • /
    • pp.89-99
    • /
    • 1991
  • The metal concentrations in lungs from 12 coal workers' pneumoconiosis(CWP) patients and 6 controls, who were not exposed occupationally to coal mine dust and metals during their life time, were analyzed by atomic absorption spectrophotometry. 1. Copper, lead, nickel, magnesium, manganese, zinc and iron concentrations in lungs of CWP patients were $1.10{\pm}0.088$, $1.12{\pm}0.068$, $0.22{\pm}0.020$, $113.7{\pm}1.31$, $0.19{\pm}0.012$, $10.2{\pm}1.54$, $426.7{\pm}2.63{\mu}g/g$ wet weight. 2. Copper, lead, nickel, magnesium, manganese, zinc and iron concentrations in lungs of controls were $1.10{\pm}0.013$, $0.85{\pm}0.007$, $0.10{\pm}0.008$, $87.6{\pm}1.29$, $0.18{\pm}0.005$, $10.6{\pm}1.44$, $164.9{\pm}3.29{\mu}g/g$ wet weight. 3. The ratios of concentrations for copper, lead, nickel, magnesium, manganese, zinc, and iron in lungs for CWP patients and controls were 1 : 1, 1.32 : 1, 2.20 : 1, 1.30 : 1, 1.06 : 1, 0.92 : 1, 2.58 : 1, respectively. There were significant differences in concentrations of lead, nickel, magnesium, iron by group(p<0.05). 4. There was no significant difference in metal concentrations of right upper lobe, right lower lobe, left upper lobe and left lower lobe for both CWP patients and controls (p>0.05, p>0.05). 5. In CWP patients lead was well correlated with nickel showing a rank correlation coefficient of 0.533, and zinc was correlated with copper showing a rank correlation coefficient of 0.476. 6. The concentrations of copper, nickel, maganese, and zinc in Korean CWP patients were lower than those in foreign CWP patients.

  • PDF

인산염을 이용한 납오염 토양 고정화 반응의 가속화

  • 이의상;이상봉;이인원
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.201-204
    • /
    • 2004
  • Immobilization is seen as a promising technology for lead remediation. In a laboratory experiment, immobilization of lead with soluble P was tested as a function of reaction time and P concentration. The P treated with an acidic solution to enhance heavy metal immobilization was worked into the soil, and within 7 days, lead was stabilized. Different molar ratios of soluble phosphates (super-phosphate and KH$_2$PO$_4$) would be considerably effective to accelerate the formation of highly insoluble minerals due to the lack of leachable Pb in the contaminated soil. Although it was demonstrated that the addition of soluble phosphates with an acidic solution significantly reduced available lead in soil up to over 95%, remaining phosphorus in soil matrix might cause a possible groundwater eutrophication in the near future.

  • PDF

Conceptual design of current lead for large scale high temperature superconducting rotating machine

  • Le, T.D.;Kim, J.H.;Park, S.I.;Kim, H.M.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.54-58
    • /
    • 2014
  • High-temperature superconducting (HTS) rotating machines always require an electric current of from several hundreds to several thousand amperes to be led from outside into cold region of the field coil. Heat losses through the current leads then assume tremendous importance. Consequently, it is necessary to acquire optimal design for the leads which would achieve minimum heat loss during operation of machines for a given electrical current. In this paper, conduction cooled current lead type of 10 MW-Class HTS rotating machine will be chosen, a conceptual design will be discussed and performed relied on the least heat lost estimation between conventional metal lead and partially HTS lead. In addition, steady-state thermal characteristic of each one also is considered and illustrated.