• 제목/요약/키워드: lead measurement

Search Result 705, Processing Time 0.026 seconds

Evaluation of lead concentration on the surface of children's playing equipments using a field portable x-ray fluorescence (FPXRF) (FPXRF를 이용한 어린이 놀이시설의 페인트 표면 납 농도 평가)

  • Kim, Nam-Soo;Choi, Seung-Hyun;Cho, Kwang-Sung;Kim, Jin-Ho;Ham, Jung-O;Ahn, Kyu-Dong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.18 no.2
    • /
    • pp.133-140
    • /
    • 2008
  • In order to evaluate the possible environmental lead hazard in children's playground and to test the practicability of field portable x-ray fluorescence(FPXRF) for environmental lead measurement, authors investigated lead concentration of lead-based paint on the surface of children's playing equipments in the playground of 13 apartments using FPXRF at the site in city A, Choongnam province. 93 spots were determined surface lead concentrations 3 times each using a FPXRF. Out of 93 spots, 83 spots (92%) were revealed to have lead in paint and mean concentration was $1.12{\pm}1.76mg/cm^2$. The mean concentration of lead on the surface of playing equipments at the apartments near the main street was $1.20mg/cm^2$ and higher than those at the apartments far away from the main street($0.81mg/cm^2$)(p<0.05). The mean concentration of lead on the surface of playing equipments painted with yellow color was $3.23mg/cm^2$ and the highest among all colors, whereas equipment painted white color was non-detectable. PVC and etc materials for construction of playing equipment showed higher surface lead concentration than other materials. The result suggests that it is necessary to be taken caution of the lead exposure in the playground of apartment and it should be taken any kind of confirmative action to prevent unwanted lead exposure from surface lead source of playing equipment. Authors found that FPXRF was very reliable and useful for field measurement to detect lead on the painted surface.

System Design and H/W Development of the Residual Stress Measurement for Ferromagnetic thin Sheet (강자성 박판소재의 잔류응력 측정 시스템의 설계 및 제작)

  • 김상원;양충진
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.2
    • /
    • pp.50-57
    • /
    • 2001
  • Magnetic inductive probe was designed and assembled for sensing the residual stress developed in the ferromagnetic thin sheet. The residual stress measurement system with this probe could resolve the residual stresses developed in the sheet in terms of principal stress orientation, and magnitude of the principal stress. It was consumed that the obtained probe output voltage from the qualified ferromagnetic Fe-42Ni lead frame sheet and quality-rejected sheet is effectively determined using the developed device. The lead frame sheet which has accumulated a high level of residual stress always showed a distinctive stress distribution and magnitude compared with those of qualified lead frame sheet. Those differences were well resolved as functions of input current or used frequency.

  • PDF

Numerical analysis of the venturi flowmeter in the liquid lead-bismuth eutectic circuit after long-term operation

  • Zhichao Zhang;Rafael Macian-Juan;Xiang Wang
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.1081-1090
    • /
    • 2024
  • The liquid Lead-bismuth eutectic is used as the coolant for Gen-IV reactor concepts. However, due to its strong corrosive and high operating temperature, it is difficult to accurately measure the flow rate in long-term operating conditions. Venturi flowmeter is a simple structured flowmeter, which plays a very important role in the flow measurement of high-temperature liquid metals, especially since the existing flowmeters are difficult to be competent. It has the advantages of easy maintenance and stable operation. Therefore, it is necessary to study the operating conditions of the venturi flowmeter under high-temperature conditions. This work performs a series of simulations of the fluid-solid interaction between the flow liquid metal and venturi flowmeter with COMSOL software, including the dimensional sensitivity analysis of the venturi flowmeter to explore the most suitable structure and parameters for liquid heavy metal, the sensitivity analysis of the geometric parameters of the venturi tube on the varying conditions. It shows that when the contraction angle of the venturi flowmeter is 33°, the diffusion angle is 13°, the diameter of the throat is 8 mm, and the temperature of the lead-bismuth eutectic is 733.15 K, it is most suitable for the measurement in the lead-bismuth circuit.

Implementation of Wearable 2-lead ECG Measurement System for Healthcare Monitoring during Daily Life (일상생활 중 모니터링이 가능한 착용형 2-Lead 심전도 계측 시스템의 구현)

  • Kim, Byung-Joo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.358-359
    • /
    • 2012
  • 본 연구에서는 범용적인 건강 모니터링에 활용할 수 있는 생체신호인 심전도를 일반 가정 내에서 뿐만 아니라 일상생활 중에서도 실시간으로 편리하게 측정할 수 있도록 초소형 저전력의 착용형 심전도 계측시스템을 구현하였다. 이를 위하여 표준 12-lead법이 아닌 모바일 또는 휴대용 장치에 적합한 2-lead법을 사용하여 심전도 계측부를 구현하였고, 심전도 계측부를 베이스 노드로 하여 심전도 신호를 가정 내 또는 실외에서도 무선으로 전송 할 수 있도록 구현하였다. 먼저 가정 내에서는 저 전력 무선센서노드를 이용하여 심전도 신호를 실시간으로 PC에 전송하여 모니터링이 가능하도록 구현 하였고, 실외에서는 저전력 통신 방식인 Bluetooth 2.0을 사용하여 스마트폰으로 심전도 신호를 실시간으로 전송해 모니터링 할 수 있도록 구현하였다.

  • PDF

Lead Exposure Status of Smelt Process Workers in Steelmaking using Scrap Iron (제강공장 고철 용해공정 근로자의 납 노출실태)

  • Gu, Dongchul;Lee, Jaehwan;Han, Areum;Kim, Hyunju;Lee, Suyeon;Yun, Soonyoung;Lee, Chae Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.164-168
    • /
    • 2013
  • Objectives: This study was aimed at the examination of the lead exposure status of smelting process workers in steelmaking using scrap iron. Methods: The study was conducted from July to September 2012 by means of measurements taken during the smelting process, with 45 minutes set for a one-time smelting work cycle when it comes to personal air sample and area air sample. As such, daily work hours were classified into 360 minutes for measurement. The analysis of lead concentration was conducted using AAs based on the NIOSH 7300 method. Results: In the case of the personal specimens that were subjected to periodical measurement 45 minutes per one session during the smelting process, 40 out of 42 specimens measured were found to contain lead, with an average concentration level of $0.028mg/m^3$ (Max: $0.182mg/m^3$, Min: $0.005mg/m^3$, TWA-more than 50%: 4 out of 6 units). In the case of regional specimens, lead was detected in 45 out of 48 specimens measured, with an average concentration level of $0.037mg/m^3$ (Max: $0.220mg/m^3$, Min: $0.007mg/m^3$ ). In the case of regional specimens subjected to measurement using a day as the work cycle, lead was detected in 15 out of 15 specimens measured, with an average concentration level of $0.049mg/m^3$ (Max: $0.478mg/m^3$, Min: $0.005mg/m^3$ ). Conclusions: It concluded that smelting process workers in steelmaking are exposed to lead because scrap iron is used as a raw material. It is thus necessary to introduce legal management to prevent occupation-related disease in smelting process workers in steelmaking.

Measurement of Energy Dependent Neutron Capture Cross Sections of $^{197}Au$ in Energy Region from 0.1 eV to 10 keV using a Lead Slowing-down Spectrometer

  • Yoon, Jung-Ran
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.29-32
    • /
    • 2010
  • The neutron capture cross section of $^{197}Au$ has been measured relative to the $^{10}B(n,{\gamma})$ standard cross section by the neutron time-of-flight(TOF) method using a 46-MeV electron linear accelerator(linac) at the Research Reactor Institute, Kyoto University(KURRI). In order to experimentally prove the result obtained, the supplementary cross section measurement has been made from 0.1 eV to 10 keV using the Kyoto University Lead slowing-down spectrometer (KULS) coupling to the linac. The relative measurement by the TOF method has been normalized to the reference value(24.5 b) at 1 eV. The evaluated capture cross sections in JENDL/D-99 Dosimetry have been compared with the current measurements by the KULS experiments.

Developing the Bullwhip Effect Measure in a Supply Chain Considering Seasonal Demand and Stochastic Lead Time (공급사슬에서 계절적 수요와 추계적 조달기간을 고려한 채찍효과 측도의 개발)

  • Cho, Dong-Won;Lee, Young-Hae
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.34 no.4
    • /
    • pp.91-112
    • /
    • 2009
  • The bullwhip effect means the phenomenon of increasing demand variation as moving UP to the upstream in the supply chain. Therefore, it is recognized that the bullwhip effect is problematic for effective supply chain operations. In this paper, we exactly quantifies the bullwhip effect for the case of stochastic lead time and seasonal demand in two-echelon supply chain where retailer employs a base-stock policy considering SARMA demand processes and stochastic lead time. We also investigate the behavior of the proposed measurement for the bullwhip effect with autoregressive and moving average coefficient, stochastic lead time, and seasonal factor.

A Study on the Characteristics of the Precision Blanking of Lead Frame (1): Influences of Blanking Process Variables (리드 프레임 타발공정의 전단특성에 관한 연구(1) -전단 공정 인자의 영향)

  • 임상헌;서의권;심현보
    • Transactions of Materials Processing
    • /
    • v.10 no.5
    • /
    • pp.425-432
    • /
    • 2001
  • In order to investigate the influences of process parameters on the shape of lead frame, experimental study has been carried out. In the experiment, dimensional accuracy of the die sets, measurement accuracy has been managed carefully enough to simulate actual lead frame blanking process. With the blanking of square-shaped specimen, the effects of clearance, strip holding pressure and bridge width on the shape of blanked profile have been investigated. Experimental results show that the burnish ratio is increased as the clearance decreases. the strip holding pressure increases, and bridge width increases. Although the results seems to be similar to the ordinary blanking, the lead frame blanking shows a subtle different characteristics to the ordinary blanking due to the narrow bridge width.

  • PDF

A Pilot Establishment of the Job-Exposure Matrix of Lead Using the Standard Process Code of Nationwide Exposure Databases in Korea

  • Ju-Hyun Park;Sangjun Choi;Dong-Hee Koh;Dae Sung Lim;Hwan-Cheol Kim;Sang-Gil Lee;Jihye Lee;Ji Seon Lim;Yeji Sung;Kyoung Yoon Ko;Donguk Park
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.493-499
    • /
    • 2022
  • Background: The purpose of this study is to construct a job-exposure matrix for lead that accounts for industry and work processes within industries using a nationwide exposure database. Methods: We used the work environment measurement data (WEMD) of lead monitored nationwide from 2015 to 2016. Industrial hygienists standardized the work process codes in the database to 37 standard process and extracted key index words for each process. A total of 37 standardized process codes were allocated to each measurement based on an automated key word search based on the degree of agreement between the measurement information and the standard process index. Summary statistics, including the arithmetic mean, geometric mean, and 95th percentile level (X95), was calculated according to industry, process, and industry process. Using statistical parameters of contrast and precision, we compared the similarity of exposure groups by industry, process, and industry process. Results: The exposure intensity of lead was estimated for 583 exposure groups combined with 128 industry and 35 process. The X95 value of the "casting" process of the "manufacture of basic precious and non-ferrous metals" industry was 53.29 ㎍/m3, exceeding the occupational exposure limit of 50 ㎍/m3. Regardless of the limitation of the minimum number of samples in the exposure group, higher contrast was observed when the exposure groups were by industry process than by industry or process. Conclusion: We evaluated the exposure intensities of lead by combination of industry and process. The results will be helpful in determining more accurate information regarding exposure in lead-related epidemiological studies.