• Title/Summary/Keyword: lead iodide

Search Result 31, Processing Time 0.026 seconds

Study of Inorganic CsPbI2Br Perovskite Solar Cell Using Hot-air Process (Hot-air 공정을 이용한 무기 CsPbl2Br 페로브스카이트 태양전진 제작 연구)

  • RINA, KIM;Dong-Gun, Lee;Dong-Won, Kang;Eundo, Kim;Jeha, Kim
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.101-106
    • /
    • 2022
  • We prepared a CsPbI2Br solution using Cesium iodide (CsI), Lead (II) bromide (PbBr2) and Lead (II) iodide (PbI2) materials into a polar solvent mixture of N,N-dimethylformamide (DMF) and Dimethyl sulfoxide (DMSO). A simple spin coating technique was used for the fabrication of CsPbI2Br absorber layer in the solution process. In order to prepare uniform coating of absorber film we adopted a hot-air process in assocation with the spin coating. It was confirmed that the thin film manufactured by the hot-air process had a higher absorption rate than that without it, and the optical band gap was measured 1.93 eV. The thin film of absorber was uniformly prepared and revealed the Black α-Cubic crystal phase as proved through X-ray diffraction analysis. Finally, a perovskite solar cell having an n-i-p structure was manufactured with a CsPbI2Br perovskite absorption layer. From the solar cell, we obtained a power conversion efficiency (PCE) of 5.97% in a forward measurement.

Radiological Accident and Acute Radiation Syndrome (방사선 사고와 급성 방사선 증후군)

  • Roh, Hyung-Keun
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.9 no.2
    • /
    • pp.39-48
    • /
    • 2011
  • In mass casualty situation due to radiological accidents, it is important to start aggressive management with rapid triage decisions. External contamination needs immediate decontamination and internal contamination should be treated with special expertise and equipment to prevent the rapid uptake of radionuclides by target organs. Acute radiation syndrome shows a sequence of events that varies with the severity of the exposure. More severe exposures generally lead to more rapid onset of symptoms and severe clinical findings. After the massive exposure, various systems of the body reflect their severe damages that can lead to death within hours or up to several months. The disease progression has classically been divided into four stages: prodromal, latent, manifest illness, and recovery or death. Three characteristic clusters of symptoms including the hematopoietic syndrome, the gastrointestinal syndrome and the cerebrovascular syndrome are all associated with the acute radiation syndrome. The standard medical management of the patients with a potentially survivable radiation exposure includes good medical, surgical and supportive measures. Specific treatment with cytokines and bone marrow transplantation should be considered. The management of internal contamination is much the same as the treatment of poisoning. The standard decontamination should be applied to reduce uptake, and the chelating agents can be administered to enhance the clearance of radioisotopes. Radioactive iodine ($^{131}I$) as one of the nuclear fission products can increase the incidence of thyroid cancer in children. Potential benefit of potassium iodide prophylaxis is greater especially in neonates, infants and small children.

  • PDF

Structural, morphological, optical, and photosensing properties of Cs2TeI6 thin film synthesized by two-step dry process

  • Hoat, Phung Dinh;Van Khoe, Vo;Bae, Sung-Hoon;Lim, Hyo-Jun;Hung, Pham Tien;Heo, Young-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.5
    • /
    • pp.279-285
    • /
    • 2021
  • Recently, cesium tellurium iodine (Cs2TeI6) has emerged as an inorganic halide perovskite material with potential application in optoelectronic devices due to its high absorption coefficient, suitable bandgap and because it consists of nontoxic and earth-abundant elements. However, studies on its fabrication process as well as photoresponse characteristics are limited. In this study, a simple and effective method is introduced for the synthesis of Cs2TeI6 thin films by a two-step dry process. A Cs2TeI6-based lateral photosensor was fabricated, and its photoresponse characteristics were explored under laser illuminations of four different wavelengths in the visible range: 405, 450, 520, and 655 nm. The initial photosensing results suggest potential application and can lead to more promising studies of Cs2TeI6 film in optoelectronics.

Color Enhancement by Oxygen Torch in Blue Sapphires (블루사파이어와 루비의 고온산소 화염처리에 의한 색향상)

  • Song Oh Sung;Kim Sang Yeob
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.2
    • /
    • pp.83-87
    • /
    • 2005
  • We enhanced the color of blue sapphires and rubies successfully by using a oxygen-propane torch flame annealing, which had not been employed so far. We confirmed that about 1 mm-thick de-coloring of the corundum samples were available with 60 minutes flame annealing through eye evaluation, color coordination characterization, and methylene iodide immersion observation. We also suggest that the color centers such as $[Fe_{Al}^{\cdot}]$ may transform into transparent $[Fe_{Al}^{x}],\;[Cr_{A1}^{x}]$ sites with $[V_o^']$ generation at the elevated temperature in oxygen-rich atmosphere by diffusion mechanism. Our results implied that the longer diffusion time and the higher oxygen partial pressure might lead to the better de-coloring enhancement in corundum gem stones.

Gold Nanoparticles-embedded MAPbI3 Perovskite Thin Films

  • Kim, Hyojung;Byun, Hye Ryung;Kim, Bora;Jeong, Mun Seok
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1725-1728
    • /
    • 2018
  • We synthesized the gold nanoparticles (Au NPs)-embedded methylammonium lead iodide ($MAPbI_3$) film for the first time. The effects of metal nanoparticles on $MAPbI_3$ perovskite were systematically studied using UV-Vis absorption and photoluminescence (PL) measurements. As a result, the 20-nm-sized Au NPs-embedded $MAPbI_3$ film exhibited a 4.15% higher absorbance than the bare $MAPbI_3$ film. Moreover, the average PL intensity of the Au NPs-embedded $MAPbI_3$ film increased by about 75.25% over the bare $MAPbI_3$ film. Therefore, we have confirmed that addition of the Au NPs has a positive effect on the optical properties of $MAPbI_3$, and we believe that this study will provide a basic insight into the metal nanoparticles-embedded perovskite thin films for the future optoelectronic applications.

Synthesis and Crystal Structure of Lead Iodide in the Sodalite Cavities of Zeolite A (LTA)

  • Kim, Seok-Han;Lim, Woo-Taik;Kim, Ghyung-Hwa;Lee, Heung-Soo;Heo, Nam-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.5
    • /
    • pp.679-686
    • /
    • 2006
  • The positions of $PbI _2$ molecule synthesized into the molecular-dimensioned cavities of $\mid K_6 (Pb _4I_2)(PbI_2) _{0.67}-(H_2O)_2\mid [Si _{12}Al _{12}O _{48}]$-LTA have been determined. A single crystal of $\mid Pb _6\mid [Si _{12}Al _{12}O _{48}]$-LTA, prepared by the dynamic ion-exchange of $\mid Na _{12}\mid [Si _{12}Al _{12}O _{48}]$-LTA with aqueous 0.05 M $Pb _(NO _3)_2$ and washed with deionized water, was placed in a stream of flowing aqueous 0.05 M KI at 294 K for three days. The resulting crystal structure of the product $( \mid K_6 (Pb _4I_2)(PbI_2) _{0.67}(H_2O)_2\mid [Si _{12}Al _{12}O _{48}]$-LTA, a = 12.353(1) $\AA$) was determined at 294 K by single-crystal X-ray diffraction in the space group Pm3 m. It was refined with all measured reflections to the final error index $R_1$ = 0.062 for 623 reflections which $F_o$ > 4$\sigma$($F_o$). 4.67 $Pb ^{2+}$ and six $K^+$ ions per unit cell are found at three crystallographically distinct positions: 3.67 $Pb ^{2+}$ and three $K^+$ ions on the 3-fold axes opposite six-rings in the large cavity, three $K^+$ ions off the plane of the eight-rings, and the remaining one $Pb ^{2+}$ ion lies opposite four-ring in the large cavity. 0.67 $Pb ^{2+}$ ions and 1.34 $I^-$ ions per unit cell are found in the sodalite units, indicating the formation of a $PbI _2$ molecule in 67% of the sodalite units. Each $PbI _2$ (Pb-I = 3.392(7) $\AA$) is held in place by the coordination of its one $Pb ^{2+}$ ion to the zeolite framework (a $Pb ^{2+}$ cation is 0.74 $\AA$ from a six-ring oxygens) and by the coordination of its two $I^-$ ions to $K^+$ ions through six-rings (I-K = 3.63(4) $\AA$). Two additional $I^-$ ions per unit cell are found opposite a four-ring in the large cavity and form $Pb _2K_2I^{5+}$ and $Pb _2K_2I^{3+}$ moieties, respectively, and two water molecules per unit cell are also found on the 3-fold axes in the large cavity.

Feasibility Study of Phosphor Particle Blended Hybrid Dosimeter for Quality Assurance in Radiation Therapy (Phosphor Particle 혼합형 Hybrid 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Shin, Yohan;Han, Moojae;Jung, Jaehoon;Cho, Heunglae;Park, Sungkwang
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.333-338
    • /
    • 2019
  • In the field of radiotherapy, the Quality Assurance(QA) procedure to verify the safety of treatment is considered to be very important. However, due to various problems of the conventional dosimeters used for the QA, researches on these dosimeters have been actively carried out to replace them. In this study, to maximize the sensitivity by visible light(VL) emitted from phosphors, blended hybrid sensors were fabricated by blending various weight percent(wt%) of $Gd_2O_2S:Tb$ which is a phosphor with excellent fluorescence efficiency into $PbI_2$. Then, the electrical properties to high energy radiation from the blended sensors and the pure $PbI_2$ sensor were compared and evaluated. As a result of the sensitivity evaluation, the sensor of 3wt% showed the highest value with more than 40% difference from the other sensors, and gradual decreasing in sensitivity was observed with increasing wt% except for the sensor of 3wt%. Also, in the reproducibility evaluation, the pure $PbI_2$ sensor exhibited a large variation in coefficient of variation(CV)>0.015, while all the blended sensors showed CV<0.015.

Flexible quantum dot solar cells with PbS-MIx/PbS-BuDT bilayers

  • Choe, Geun-Pyo;Yang, Yeong-U;Yun, Ha-Jin;Im, Sang-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.347.2-347.2
    • /
    • 2016
  • Recently, in order to improve the performance of the colloidal quantum dot solar cells (CQDSCs), various efforts such as the modification of the cell architecture and surface treatment for quantum dot (QD) passivation have been made. Especially, the incorporation of halides into the QD matrix was reported to improve the performances significantly via passivating QD trap states that lower the life-time of the minority-carrier. In this work, we fabricated a lead sulfide (PbS) QD bilayer treated with different ligands and utilized it as a photoactive layer of the CQDSCs. The bottom and top PbS layer was treated using metal iodide ($MI_x$ and butanedithiol (BuDT), respectively. All the depositions and ligand treatments were carried out in air using layer-by-layer spin-coating process. The fabrication of the active layers as well as the n-type zinc oxide (ZnO) layer was successfully carried out on the bendable indium-tin-oxide (ITO)-coated polyethylene terephthalate (PET) substrate, which implies that this technique can be applied to the fabrication of flexible and/or wearable solar cells. The power conversion efficiency (PCE) of the CQDSCs with the architecture of $PET/ITO/ZnO/PbS-MI_x/PbS-BuDT/MoO_x/Ag$ reached 4.2 %, which is significantly larger than that of the cells with single QD (PbS-BuDT) layer.

  • PDF

Synthesis of a New Hexadendates Schiff's Base and Its Application in the Fabrication of a Highly Selective Mercury(II) Sensor

  • Ganjali, M.R.;Norouzi, P.;Alizadeh, T.;Salavati-Niasari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.1
    • /
    • pp.68-72
    • /
    • 2007
  • A new PVC membrane potentiometric sensor that is highly selective to Hg2+ ions was prepared, using bis(2-hydroxybenzophenone) butane-2,3-dihydrazone (HBBD) as an excellent hexadendates neutral carrier. The sensor works satisfactorily in the concentration range of 1.0 × 10-6 to 1.0 × 10-1 mol L-1 (detection limit 4 × 10-7 mol L-1) with a Nernstian slope of 29.7 mV per decade. This electrode showed a fast response time (~8 s) and was used for at least 12 weeks without any divergence. The sensor exhibits good Hg2+ selectivity for a broad range of common alkali, alkaline earth, transition and heavy metal ions (lithium, sodium, potassium, magnesium, calcium, copper, nickel, cobalt, zinc, cadmium, lead and lanthanum). The electrode response is pH independent in the range of 1.5-4.0. Furthermore, the developed sensor was successfully used as an indicator electrode in the potentiometric titration of mercury ions with potassium iodide and the direct determination of mercury in some binary and ternary mixtures.

The Evaluation and Fabrication of Photoconductor Sensor for Quality Assurance of Radiation Therapy Devices (방사선치료기기 정도관리를 위한 광도전체 센서 제작 및 평가)

  • Kang, Sang Sik;Noh, Sung Jin;Jung, Bong Jae;Noh, Ci Chul;Park, Ji Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.565-569
    • /
    • 2016
  • Recently, a use of linear accelerator with a multi-leaf collimator(MLC) for radiation therapy is increasing. The importance of quality assurance (QA) for the linear accelerator is emphasized as the side effects of the inaccurate delivery of the radiation beam has been increased according to the high dose irradiation technique. In this study, The $HgI_2$ and $PbI_2$ photoconductor layer samples of $400{\mu}m$ thickness were fabricated using sedimentation method among particle-in-binder technology. From the fabricated samples, the electrical properties(dark current, output current, response properties and linearity) were investigated. From the experimental results, $HgI_2$ has good charge signal generation and linearity. Finally, from the signal response results about various thickness of $HgI_2$ sensor, the signal creation efficiency of $400{\mu}m$ thickness of $HgI_2$ sensor has the highest value and the excellent reproducibility below ${\pm}2.5%$.