• 제목/요약/키워드: lead absorption

검색결과 374건 처리시간 0.021초

pH Effect on Lead Transport into astrocytes by Divalent Metal Transporter 1 (DMT1/Nramp2)

  • Cheong, Jae-Hoon;Desmond I. Bannon;Josep P. Bressler
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2001년도 추계학술대회 및 정기총회
    • /
    • pp.91-91
    • /
    • 2001
  • Nramp2, also known as DMT1 and DCT1, is a 12-transmembrane domain protein responsible for dietary iron uptake as well as metal ions such as lead, manganese, zinc, copper, nickel, cadmium, and cobalt. High expression of DMT1 increase lead uptake, and DMT1-dependent lead transport was H -dependent and inhibited by iron ions. The molecular mechanism of lead transport in CNS is as yet unknown. although interactions between iron and lead at the level of absorption have been known for some time. The process of lead uptake into astrocytes was not known yet. Nramp2 may mediate transport of heavy metal into astrocytes. We investigated whether Nramp2 mediate transport of lead into astrocytes. And we do whether Nramp2 was expressed highly by deprivation of iron in Astrocytes, and lead uptake into astrocytes was influenced by expression of Nramp2. Immortalized human fetal astrocyte(SV-FHA) cells were cultured in medium containing Dulbecco's modified Eagle's medium and treated with Deferoxamine. Northern blot analysis was done for determining mRNA level of DMT1 and lead uptake assay was done in incubation condition of pH 5.5 and 7.4.

  • PDF

Effect of Carbonization Temperature on Hygric Performance of Carbonized Fiberboards

  • Lee, Min;Park, Sang-Bum;Lee, Sang-Min
    • Journal of the Korean Wood Science and Technology
    • /
    • 제42권5호
    • /
    • pp.615-623
    • /
    • 2014
  • Increases of public attention on healthy environment lead to the regulation of indoor air quality such as Clean Healthy House Construction Standard. This standard covers emission of total volatile organic compounds (TVOCs) (e.g., formaldehyde, benzene, and toluene), ventilation, and use of environmentally-friendly products or functional products. Moisture absorption and desorption abilities are a recommended functionality for improving indoor air quality. In this study, moisture absorption and desorption capacities of carbonized board from wood-based panels and other materials were determined by using UNT-HEAT-01 according to ISO 24358:2008. Pine had higher moisture absorption and desorption capacities ($49.0g/m^2$ and $35.3g/m^2$, respectively) than hinoki cypress, cement board, gypsum board, oriented strand board, and medium density fiberboard (MDF). The moisture absorption and desorption capacities differed considerably according to the wood species. After carbonization process at $400^{\circ}C$, the absorption and desorption ability of MDF increased to 38% and 60%, respectively. However, moisture absorption and desorption capacities decreased with increasing carbonization temperature, but they were still higher than original MDF. Therefore, it is suggested that carbonization below $600^{\circ}C$ can improve moisture absorption/desorption capacities.

Indirect Determination of Nitrite by Flame Atomic Absorption Spectrometry Using a Lead(IV) Dioxide Oxidant Microcolumn

  • Noroozifar, Meissam;Khorasani Motlagh, Mozhgan;Taheri, Aboozar;Homayoonfard, Marjan
    • Bulletin of the Korean Chemical Society
    • /
    • 제27권6호
    • /
    • pp.875-880
    • /
    • 2006
  • A new, simple and fast flow injection analysis (FIA) method has been developed for the indirect determination of nitrite. The proposed indirect automatic method is based on the oxidation of nitrite to nitrate using a lead(IV) dioxide oxidant microcolumn where the flow of the sample through the microcolumn reduces the $PbO_2$ solid phase reagent to Pb(II), which is measured by flame atomic absorption spectrometry. The absorbance of Pb(II) are proportional to the concentration of nitrite in the samples. The calibration curve was linear up to 30 mg $L ^{-1}$, with a detection limit of 0.11 mg $L ^{-1}$ for a 400 mL injected sample volume and a sampling rate of about 80 $h ^{-1}$. The results exhibit no interference from the presence of large amounts of ions. The developed procedure was found to be suitable for the determination of nitrite in foodstuffs and wastewaters. A relative standard deviation better than 0.9% was obtained in a repeatability study. The reliability of the method was established by parallel determination against the standard method.

식물에 의한 납, 카드뮴 흡수 기작에 미치는 자유이온 및 유기산-중금속 복합체의 영향 (Effects of free metal ions and organo-metal complexes on the absorption of lead and cadmium by plants)

  • 이미나;서병환;김권래
    • Journal of Applied Biological Chemistry
    • /
    • 제64권2호
    • /
    • pp.159-164
    • /
    • 2021
  • 토양 중 중금속은 자유이온, 유기산-중금속 복합체를 포함한 다양한 화학종으로 존재한다. 이 중 중금속 자유이온 비율은 식물체의 중금속 흡수와 밀접한 관련이 있는 것으로 알려져 있다. 본 연구는 중금속 자유이온과 유기산-중금속 복합체 존재 비율이 식물의 납, 카드뮴 흡수에 어떤 영향을 미치는지 알아보기 위하여 수행되었다. 이를 위해 순환식 양액재배 장치에서 28일간 키운 상추를 48시간 동안 납과 카드뮴 용액에 침지시키는 실험을 진행하였다. 침지 전 시트르산, 옥살산, 아세트산, 휴믹산을 이용해 납과 카드뮴 용액의 중금속 자유이온과 유기산-중금속 복합체의 비율이 100:0, 90:10, 70:30, 60:40이 되도록 조절하였다. 침지 후 상추 뿌리와 잎의 납, 카드뮴 농도를 분석한 결과, 용액 중 중금속 자유이온의 비율과 식물이 흡수한 납, 카드뮴 농도는 상관관계를 보이지 않았다. 반면에 처리한 유기산의 종류와 중금속 종류에 따른 차이가 더 큰 것으로 나타났다. 시트르산은 납 흡수는 증가시켰지만 카드뮴 흡수는 감소시켰다. 시트르산은 다른 유기산보다 상추의 납 흡수율을 높였는데 이는 시트르산이 분자량이 크기 때문에 중금속 이온과 복합체를 형성할 수 있는 용량이 더 크기 때문인 것으로 보인다. 그러므로 본 연구 결과는 식물에 의한 중금속 흡수가 단순히 자유이온의 양에 따라 달라지기 보다는 존재하는 유기산의 분자량에 의한 결합용량 차이가 중금속 종류에 따라 달리 작용하여 결정된다는 것을 보여준다.

Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자에너지 플루언스와 질량에너지흡수계수 유도 (Derivation of Photon Energy Fluence and Mass Energy Absorption Coefficient for 1 Gy Absorbed Dose of Water in Brachytherapy using Ir192 Source)

  • 김종언;안일훈
    • 한국방사선학회논문지
    • /
    • 제16권1호
    • /
    • pp.61-66
    • /
    • 2022
  • 이 연구의 목적은 Ir192 선원을 이용한 근접치료에서 물 흡수선량 1 Gy에 대한 광자 에너지플루언스와 질량에너지흡수계수를 유도하는데 있다. Khan이 저술한 방사선치료물리학으로부터 Ir192 선원의 감마선 선속에 대한 납의 반가층을 얻었다. 얻어진 납의 반가층으로부터 선감쇠계수와 질량감쇠계수를 산출하였다. 산출된 납의 질량감쇠계수를 NIST의 납의 질량감쇠계수 자료에 대응시켜 일치하는 질량감쇠계수의 광자에너지를 유효에너지로 결정하였다. 결정된 유효에너지를 NIST의 물의 질량에너지흡수계수 자료의 광자에너지에 대응시켜서, 물의 질량에너지흡수계수는 0.03273 cm2/g(32.73 cm2/kg)으로 얻었다. 얻어진 물의 질량에너지흡수계수(32.73 cm2/kg)를 물 흡수선량 1 Gy에 나누어 광자에너지플루언스는 0.03055 J/cm2으로 산출하였다.

Polyethylene Film을 利用한 赤外線分光分析用 Cell (A Yew Technique for Infrared Spectroscopy using Polyethylene Film Cell)

  • 성좌경;노익삼
    • 대한화학회지
    • /
    • 제7권1호
    • /
    • pp.58-64
    • /
    • 1963
  • Authors propose a new technique using polyethylene film instead of sodium chloride window as a cell material. Nujol mulls, liquids and aqueous solutions are sandwitched between two pieces of polyethylene film which are held between cardboards. Ordinary lead or stainless steel spacers could be used if exact cell thickness is desired. A more elaborate cell can be assembled by injecting samples between two pieces of polyethylene film which are placed between sodium chloride windows of ordinary demountable liquid cell. The absorption bands due to polyethylene and Nujol are compensated by placing the polyethylene film of suitable thickness in the reference beam. The absorption bands due to solvents such as water can also be compensated by the polyethylene film cell sandwitched solvent of suitable thickness in the reference beam. This method would be a simple new technique. Especially this technique may offer a new helpful way for the investigation of the state of substances in aqueous system. Using this technique, authors have observed the appearance of an absorption bands at 3.2 micron, in the spectrum of phenol in aqueous solution, that is absent in the spectrum of phenol in benzene solution. The same absorption band also has been observed in the spectra of aqueous formaldehyde solution and aqueous polyvinyl alcohol solution, where the absorption bands due to polyethylene and water are compensated. Although it may be regarded that this absorption band is related to the intermolecular interaction between water and the solute having OH group, that is hydrogen bonding. The exact assignment of this absorption band is out of this work.

  • PDF

혈중 연 및 아연 분석의 정도에 관한 연구 (Study on the Precision in Determinations of Lead and Zinc in the Whole Blood)

  • 박정덕
    • Journal of Preventive Medicine and Public Health
    • /
    • 제19권1호
    • /
    • pp.76-84
    • /
    • 1986
  • Analyses of lead and zinc were made by means of standard addition method using atomic absorption spectrophotometer(Baird Ltd., Model A5100) with flameless method for lead and flame method for zinc. The blood samples used were merely diluted with triton x-100, because it was simple, rapid and minimal risk of contamination. Mean recovery rate for lead added to the blood ranged from 97.7 to 101.3% with coefficient of variation ranging from 1.9 to 10.7%, and that for the added zinc ranged from 99.0 to 102.2% with coefficient of variation ranging from 2.1 to 9.1%. In repeated measurements of zinc in the blood, good reproducibility and interindividual variation were proved(p<0.01). In comparison of the lead and zinc concentrations in the blood determined by the standard addition method and standard method, there were good correlations between 2 sets of data (r=0.9731 for lead and r=0.9785 for zinc), although lead levels were estimated higher by the former method(p<0.01) and zinc levels by the latter method(p<0.01). It can be concluded that lead and zinc levels in blood standard addition method is reliable for determination of lead and zinc in the blood with good accuracy and reproducibility.

  • PDF

흑연로 원자 흡광 광도법과 유도 결합 플라즈마 질량 분석법을 이용한 혈중 납 농도 비교 (Comparison of Blood Lead Concentration Using Graphite Furnace Atomic Absorption Spectrometry (GF-AAs) and Inductively Coupled Plasma-mass Spectrometry (ICP-MS))

  • 강민경;권정연;김병권;임현주;서정욱;김유미;홍영습
    • 한국환경보건학회지
    • /
    • 제45권3호
    • /
    • pp.258-266
    • /
    • 2019
  • Objectives: In this study, blood lead was analyzed using graphite furnace atomic absorption spectrometry (GF-AAs) and inductively coupled plasma mass spectrometry (ICP-MS). We tried to examine the difference and consistency of the analytical values and the applicability of the analytical method. Methods: We selected 57 people who agreed to participate in this study. After confirming the linearity of the calibration standard curves in GF-AAs and ICP-MS, the concentrations of lead in quality control material and samples were measured, and the degree of agreement was compared. Results: The detection limit of the ICP-MS was lower than that of GF-AAs. The coefficient of variation of reference materials was shown to be stable in the ICP-MS and GF-AAs. When the correspondence between the two equipments was verified by bias of the analysis values, a concordance was shown, and approximately 98% of the ideal reference lines were present within ${\pm}40%$ of the deflection. Conclusion: GF-AAs showed high sensitivity to single heavy metal analysis, but it took much time and showed higher detection limit than ICP-MS. Therefore, it would be considered necessary to switch to ICP-MS analysis method, considering that the level of lead exposure is gradually decreasing.

Corrosion resistant self-compacting concrete using micro and nano silica admixtures

  • Jalal, Mostafa
    • Structural Engineering and Mechanics
    • /
    • 제51권3호
    • /
    • pp.403-412
    • /
    • 2014
  • In this paper, enhancement of corrosion and chloride resistance of high performance self compacting concrete (SCC) through incorporating nanosilica into the binder has been investigated. For this purpose, different mixtures were designed with different amounts of silica fume and nano silica admixtures. Different binder contents were also investigated to observe the binder content effect on the concrete properties. Corrosion behavior was evaluated by chloride penetration and resitivity tests. Water absorption and capillary absorption were also measured as other durability-related properties. The results showed that water absorption, capillary absorption and Cl ion percentage decreased rather significantly in the mixtures containing admixtures especially blend of silica fume and nano silica. By addition of the admixtures, resistivity of the SCC mixtures increased which can lead to reduction of corrosion probability.

Experimental investigation on thermal behavior, sound absorption, and flammability of natural fibre polymer composites

  • Ravi Kumar, B.;Hariharan, S.S.
    • Structural Engineering and Mechanics
    • /
    • 제76권5호
    • /
    • pp.613-618
    • /
    • 2020
  • Exhausting oil resources and increasing pollution around the world are forcing researchers to look for new, renewable, biodegradable materials to lead sustainable development. The use of fiber reinforced composites based on natural fibres has increasingly begun as prospective materials for various engineering applications in the automotive, rail, construction and aerospace industries. The natural fiber chosen to make the composite material is plant-based fibre, e.g. jute fibre, and hemp fibre. Thermosetting polymer based Epoxy (LY556) was utilized as matrix material and The composites were produced using hand lay-up technique. The fabricated composites were tested for acoustic testing, thermo-gravimetric analysis (TGA) and flammability testing to asses sound absorption, thermal decomposition and fire resistivity of the structures. Hemp fibre composites have shown improved thermal stability over Jute fibre composites. However, the fire resistance characteristics of jute fibre composites are better as compared to hemp fibre composites. The sound absorption coefficient of composites was found to enhance with the increase of frequency.