• Title/Summary/Keyword: leaching of copper

Search Result 109, Processing Time 0.027 seconds

Chemical Leaching of Co, Cu, Ni, Al, Fe by Organic acid from Cobalt Concentrate (코발트 정광(精鑛)으로부터 유기산(有機酸)을 이용(利用)한 Co, Cu, Ni, Al, Fe의 화학적(化學的) 침출(浸出))

  • Ahn, Jae-Woo;Ahn, Hyo-Jin;Kim, Meong-Woon
    • Resources Recycling
    • /
    • v.20 no.6
    • /
    • pp.63-70
    • /
    • 2011
  • Enviromental friendly leaching process for the recovery of cobalt and copper from the cobalt concentrate was investigated by organic acids as a leaching reagent. The experimental parameters, such as organic acid type, concentrations of leachant, time and temperature of the reaction as well as the solid to liquid ratio were tested to obtain the optinum conditions for the leaching of cobalt and copper. The results showed that citric acid was the most effective leaching reagent among the organic acids used in this experiment. About 99% of cobalt, 95% of copper and 70% of nickel was dissolved by 2.0 M of citric acid. Addition of 3.0 vol.% of hydrogen perioxide was effective to enhance the leaching efficiency and the optinum temperature was found to be about $70^{\circ}C$.

Studies on Utilization of Chitosan for Fixation of Copper Compound in Wood Preservative Treatment (목재방부리(木材防腐理)에 있어서 구리화합물(化合物) 정착제(定着濟)로서 키토산 이용(利用)에 관한 연구(硏究))

  • Lee, Jong-Shin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.92-98
    • /
    • 1997
  • To make good use of chitosan forming complex with heavy metals in wood preservative treatment, woods impregnated with chitosan and copper sulfate were prepared. Amounts of leached copper, decay resistance, anti-mold efficacy, iron corrosion rates, moisture regain rates and degradation pattern in chitosan pre-treated and untreated wood were compared. After leaching test, amounts of leached copper from chitosan pre-treated wood had a much smaller than chitosan untreated wood, and good decay resistance was retained even after leaching test. From these results, it was proved that chitosan-copper complex formed in wood played and important role for decay durability. In chitosan pre-treated wood, damage values by test molds became remarkably smaller, but the growth of test molds was not perfectly inhibited. Distinct differences in iron corrosion rates between chitosan pre-treated and untreated woods was not recognized but chitosan pre-treated wood showed the lower moisture regain rates than chitosan untreated wood because of water insoluble chitosan membrane formed in wood. After leaching test, the tracheid walls in the wood treated with 2.0% copper sulfate only were eroded by the fungal attacks, but those in the wood pre-treated with chitosan remained almost intact.

  • PDF

Leaching of copper and silver from ground mobile phone printed circuit boards using nitric acid (핸드폰 기판(基板)으로부터 구리와 은의 질산(窒酸) 침출(浸出) 연구(硏究))

  • Le, Long Hoang;Yoo, Kyong-Keun;Jeong, Jin-Ki;Lee, Jae-Chun
    • Resources Recycling
    • /
    • v.17 no.3
    • /
    • pp.48-55
    • /
    • 2008
  • Leaching of copper and silver from mobile phone PCBs(printed circuit boards) with nitric acid was performed to investigate the effects of nitric acid concentrations, leaching temperatures, agitation speeds, and pulp densities on the leaching behaviors of Cu and Ag. The leaching rate considerably increased with increasing acid concentration and temperature. The leaching ratios of Cu and Ag were found to be 96.4% and 96.5%, respectively, under the optimum condition; at $80^{\circ}C$ with 2mol/L $HNO_3$ and 120g/L in pulp density within 39minutes. The kinetic parameters were determined based on the shrinking core model with reaction control corresponding to small particles. The activation energies for the leaching of copper and silver were found to be 45.5kJ/mol and 60.5kJ/mol at $35{\sim}80^{\circ}C$ with 2mol/L $HNO_3$, respectively.

Leaching of Copper and Other Metal Impurities from a Si-Sludge Using Waste Copper Nitrate Solution (실리콘 슬러지로부터 폐질산구리용액을 이용한 구리 및 금속불순물의 침출)

  • Jun, Minji;Srivastava, Rajiv Ranjan;Lee, Jae-chun;Jeong, Jinki
    • Resources Recycling
    • /
    • v.25 no.3
    • /
    • pp.11-19
    • /
    • 2016
  • A fundamental study to recycle a Si-Sludge and waste copper nitrate solution acid solution generated by domestic electronic industries was carried out. The waste copper nitrate solution was used as the lixiviant to leach the metals like Cu, Ca, Fe, etc. from the sludge leaving Si in the residues. The effect of reaction temperature, time and pup density on the metals leaching from the sludge was investigated. To enhance the extractability of Fe, the effect of HCl, $HNO_3$ and $H_2O_2$ introduced additionally during the leaching was also examined. Considering the leaching efficiency of Fe along with Cu, the leaching conditions comprising of 200 ~ 225 g/L pulp density and $90^{\circ}C$ temperature for 30 min were optimized. Under this condition, 98.27 ~ 99.17% Cu could be dissolved in the leach liquor with the obtained purity of Si in the residues as 98.69 ~ 98.86 %. The study revealed that the leaching of Cu contained in the Si-Sludge with the waste copper nitrate solution is a plausible approach by which the obtained leach liquor can further be treated suitably to recover Cu as the high pure value-added products.

A study on Bacterical Leaching of Low-Grade Copper Mineral(III) (저품위 동광석의 세균침출에 관한 연구 3)

  • 이강순;민봉희;장정순
    • Korean Journal of Microbiology
    • /
    • v.11 no.2
    • /
    • pp.69-78
    • /
    • 1973
  • In order to investigate the distribution of an iron-oxidizing bacterium, Ferrobacillus ferrooxidans in Korea, the authors had carried out the chemical and microbiological analysis of mine water. The results obtained were as follows : 1. Ferrobacillus ferrooxidans concerned to leaching was isolated from 10 copper mine water out of 46 sites in Korea. 2. As the results of bacterial oxidation, the contents of sulfuric acid, ferric sulphate and copper in the bacteria-bearing solutions were higher than those in bacteria-free solutions.

  • PDF

Effects of Additives (Hydrogen Peroxide and Ethylene Glycol) and Temperature on the Leaching of Copper from Chalcopyrite by Sulfuric Acid Solution (황산용액에 의한 황동광으로부터 구리 침출 시 첨가제(과산화수소와 에틸렌글리콜) 및 온도의 영향)

  • Kim, So-Hyun;Ahn, Jong-Gwan;Shin, Shun-Myung;Chung, Kyeong-Woo
    • Resources Recycling
    • /
    • v.25 no.5
    • /
    • pp.36-43
    • /
    • 2016
  • The leaching behaviors of copper from chalcopyrite were investigated by sulfuric acid. The leaching of copper was examined according to concentration of sulfuric acid, leaching temperature and addition of hydrogen peroxide and ethylene glycol. The concentrations sulfuric acid and hydrogen peroxide in the leaching solution were increased, the leaching efficiencies of Cu were increased. At $30 -60^{\circ}C$, the leaching efficiency of Cu was increased but it was decreased at $70 - 80^{\circ}C$. The results were due to the increasing of hydrogen peroxide decomposition in the solution above $70^{\circ}C$. In the case of ethylene glycol added at $80^{\circ}C$, the decomposition of hydrogen peroxide was decreased and the leaching efficiency was increased. As a result of SEM analysis of leaching residue after leaching, the residue was found to porous form in the case of the ethylene glycol added and then the leaching efficiency of Cu was increased by the increase of surface area under $60^{\circ}C$ with ethylene glycol.

Fixation and Leaching Characteristics of CCA- and CCFZ- Treated Domestic Softwood Species

  • Kim, Jae-Jin;Kim, Hyung-Jun;Ra, Jong-Bum;Chun, Su Kyoung;Kim, Gyu-Hyeok
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.55-59
    • /
    • 2003
  • The fixation and leaching characteristics of chromated copper arsenate (CCA Type C) and chromium- copper-fluoride-zinc (CCFZ) in domestic softwood (Japanese red pine, Korean pine, and Japanese larch) sapwood were investigated using the expressate method to follow chromium fixation and the American Wood-Preservers' Association (AWPA) leaching procedure to determine leaching properties after fixation. The rates of fixation were affected by preservative types; CCA was fixed much faster than CCFZ for all species evaluated. There were definite differences in the fixation rates of different species, with Korean pine requiring shorter to fix than the other species evaluated. Chromium fixation was greatly enhanced by elevated temperatures, and fixation time can be estimated according to fixation temperatures applied. The percentage of arsenic and zinc leached from domestic softwoods was relatively high compared to chromium and copper, indicating that there is still a relatively high unfixed arsenic and zinc components after complete chromium fixation in CCA-and CCFZ-treated samples, respectively.

A Study on Leaching and Solvent Extraction for the Recovery of Copper Ore for Small-Scale Mining in Tanzania (탄자니아의 소규모 광산에서 구리광석 정제를 위한 침출 및 용매 추출에 관한 연구)

  • Soh, Soon-Young;Chun, Yong-Jin;Itika, Ambrose J.M.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.438-445
    • /
    • 2017
  • Tanzania has abundant copper deposits, but copper-metal extraction remains low there, owing to the lack of suitable copper recovery processes and insufficient funds for developing mining technologies. Accordingly, leaching and solvent extraction methods for the extraction of copper from copper ore were studied with a particular emphasis on developing a simple processing method for small-scale copper mining. Chrysocolla ore was used as the copper-bearing mineral and sulfuric acid was used as the leaching reagent. A maximum copper recovery of 95.1% was obtained when the particles in the sample were smaller than $53{\mu}m$, the concentration of 98%(w/w) sulfuric acid in the leaching solution was 5.0 g/L and the stirring rate was between 60 and 80 rpm. The highest selectivity of $Cu^2+$ in the solvent extraction was obtained using 15% LIX-70 in kerosene. In the pH range from 0.5 to 3.0, the efficiency of $Cu^2+$ extraction increased with increasing pH. However, at pH values higher than 3.0, other metal ions were extracted into the organic phase more readily than $Cu^2+$. The highest solvent extraction rate obtained was 96.5% at pH values of 2.0 and 3.0 using 15% LIX-70.

Leaching behavior of copper using electro-generated chlorine in hydrochloric acid solution (전해생성(電解生成)된 염소(鹽素)에 의한 구리의 침출(浸出) 거동(擧動))

  • Kim, Eun-Young;Kim, Min-Seuk;Lee, Jae-Chun;Jung, Jin-Ki
    • Resources Recycling
    • /
    • v.15 no.6 s.74
    • /
    • pp.33-40
    • /
    • 2006
  • Leaching behavior of copper using electro-generated chlorine was investigated in hydrochloric acid solutions. When leached copper concentration was lower than 3.6g/L, the utilization efficiency of the electro-generated chlorine was close to 100% at $10mA/cm^2,\;25^{\circ}C$, 400 rpm in 1M HCl solutions. The concentration ot the leached copper over 3.6g/L caused the electrode potential to drop quietly, leading to a change or leaching mechanism. The leaching rate oi copper began to decrease at the concentration of copper 5.2g/L. This is probably due to the formation of a layer of CuCl on Cu metal in 1M HCl solutions. The leaching rate, however, was not retarded in a solution ot high chloride concentration. The high solubility of CuCl in the solution may prevent the formation of CuCl on Cu metal.

The Characteristic Dissolution of Valuable Metals from Mine-Waste Rock by Heap Bioleaching, and the Recovery of Metallic Copper Powder with Fe Removal and Electrowinning (더미 미생물용출에 의한 폐-광석으로부터 유용금속 용해 특성과 Fe 제거와 전기분해를 이용한 금속구리분말 회수)

  • Kim, Bong-JuK;Cho, Kang-Hee;Choi, Nag-Choul;Park, Cheon-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.207-222
    • /
    • 2014
  • In order to recover the metallic copper powder from the mine-waste rock, heap bioleaching, Fe removal and electrowinning experiments were carried out. The results of heap leaching with the mine-waste rock sample containing 0.034% Cu showed that, the leaching rate of Cu were 61% and 62% in the bacteria leaching and sulfuric acid leaching solution, respectively. Sodium hydroxide (NaOH), hydrogen peroxide ($H_2O_2$) and calcium hydroxide ($Ca(OH)_2$) were applied to effectively remov Fe from the heap leaching solution, and then $H_2O_2$ was selected for the most effective removing Fe agent. In order to prepare the electrolytic solution, $H_2O_2$ were again treated in the heap leaching, and Fe removal rates were 99% and 60%, whereas Cu removal rates were 5% and 7% in the bacteria and sulfuric acid leaching solutions, respectively. After electrowinning was examined in these leaching solution, the recovery rates of Cu were obtained 98% in bacteria and obtained 76% in the sulfuric leaching solution. The dendritic form of metallic copper powder was recovered in both leaching solutions.