• Title/Summary/Keyword: lateral stress

Search Result 807, Processing Time 0.027 seconds

Microscopic Analysis of Prefinitely Strained Cement Paste

  • Song, Ha-Won;Kim, Jang-Ho;Choi, Jae-Hyeok;Byun, Keun-Joo
    • KCI Concrete Journal
    • /
    • v.11 no.3
    • /
    • pp.127-140
    • /
    • 1999
  • In this paper, a microscopic analysis of prefinitelv strained cement paste specimen was carried out. The microscopic behavior of concrete under triaxial stress must be fully understood in order to explain the additional ductilitv that comes from lateral confinement and to get microstructural information in large deformed and large strained concrete. The so-called "tube-squash" test was applied to achieve enormously high shear and deviatoric strain of concrete under extremly high pressure without fracture. Then, microscopic analyses by focusing on hydration and microstructure of Prefinitely strained cement paste were carried out on cored-out deformed and virgin (undeformed) cement paste specimens : the first specimen being 40 days old, the second one being one year old. The microscopic analysis bv Field Emission Scanning Electronic Microscope (FESEM) was carried out for comparison between the specimens after 40 days and those arter one year. For one year old specimens, X-Ray Diffractometer (XRD) analysis, Energy Dispersive x-rav Spectrometer (EDS) analysis, and Differential Thermal Analysis/Thermo-Gravitv (DTA/TG) analysis were also carried out to study the hydration and the microstructures of prefinitely strained cement paste specimen by focusing on the methodologies of their microscopic analyses. analyses.

  • PDF

Economics on Structural Floor Systems of Super Tall Buildings

  • Shin Sung-Woo;Ahn Jong-Moon;Choi Myung-Shin;Seo Dae-Won;Kim Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.609-613
    • /
    • 2004
  • An economic analysis is one of the most dominant factors to determine the project feasibility of super tall building. In economic considerations, it is very important toadopt optimum structural floor systems because these are dependent on both the cost and the duration of construction. The economics affected by structural floor systems are more distinct athigher story. As the story increases, the construction cost of floor system. is accumulated linearly, while the cost of lateral resisting system is increased geometrically. The purpose of this study is to investigate the economical effects of super tall buildings through application of optimum structural floor systems. Three types of structural systems(RC beam-column frame, RC flat plate frame, and Steel frame) of super tall buildings having 50-stories are considered in this study and compared to RC flat plate slab with other systems. Analytical result shows that RC flat plate slab using lightweight concrete ismost effective in both the cost and the duration of construction.

  • PDF

A Study on the Thermal Deformation of Current Collectors by Burning Heat Pellets in Thermal Batteries (열전지의 열원 연소에 따른 전류집전체 열변형에 관한 연구)

  • Ji, Hyun-Jin;Kim, Jong-Myong;Kim, Young-Chul;Cho, Sung-Baek
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.527-534
    • /
    • 2012
  • Thermal batteries are primary batteries that use molten salts as an electrolyte and employ an internal pyrotechnic source to heat the battery stack to operating temperatures, typically between 450 and $550^{\circ}C$. The unit cell of thermal batteries consists of an anode, an electrolyte, a cathode, a heat pellet and a current collector. The heat source for such batteries is typically heat pellets based on $Fe/KClO_4$. The elevated temperature by combustion of heat pellet is supposed to cause a flatness non-uniformity, buckling, with a lateral extension diameter of current collector. This paper mainly focused on the combustion and buckling model of current collector to simulate the effect of heat source. Mechanical stresses in the current collector caused by thermal stress is a critical design consideration of thermal batteries because the internal short circuit could be occurred.

Nonlinear Analysis of Cyclic Lateral Forced RC Shear Wall (반복 횡하중을 받는 철근콘크리트 전단벽의 비선형 해석)

  • Kim, Geon-Woo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.5
    • /
    • pp.161-168
    • /
    • 2010
  • Practicing engineers and researchers need computational tools that estimate accurately the cyclic response of RC walls, and in particular, force and deformation capacities and their materials strains. So this paper describes a nonlinear truss modeling approach for reinforced concrete walls, or in general, for plane stress reinforced concrete elements subjected to cyclic reversals. Nonlinear vertical, horizontal, and diagonal truss elements are used to represent concrete and steel reinforcement. The wall having aspect ratio of 1.2 was chosen to be compared with the experimental results. Here, four types of main diagonal member models and three types of diagonal members models were applied to find out more accurate results of analysis.

Investigation on Inelastic Behavior of Tall Buildings Based on Efficient Analysis Algorithm (효용적인 알고리즘에 의한 초고층건물의 비탄성 해석 연구)

  • Ju, Young Kyu;Hong, Won Kee;Kim, Sang Dae;Park, Chil Lim
    • Journal of Korean Society of Steel Construction
    • /
    • v.10 no.1 s.34
    • /
    • pp.115-123
    • /
    • 1998
  • In design of tall buildings, the flows of stress and ultimate strength of structures cannot be obtained by the elastic analysis alone. The current inelastic analysis are very impractical for practical engineer due to the amount of work involved in engineering calculation. In this paper the PC-based inelastic analysis by the residual strength ratio concepts is introduced. The efficiency of inelastic analysis is evaluated by comparing the results of inelastic analysis with those of elastic analysis for the existing tall buidling located in Seoul. Some modification in terms of lateral resisting structural system is proposed to improve the system ductility.

  • PDF

A Study on the Structural Safety Analysis for Vinyl House at Wind Load (비닐하우스의 풍하중 구조안전성 검토에 관한 연구)

  • Paik, Shinwon
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.72-77
    • /
    • 2019
  • Vinyl house consists of main rafter, lateral member, clamps and polyethylene film. Many vinyl houses are used to grow fruits, flowers and vegetables in the countryside. Due to climate change, vinyl houses are often destroyed by strong winds or typhoons in summer. Many farmers suffer great economic damage from the collapse of vinyl houses. So it is very important to build a safe vinyl house and find a method to withstand this heavy wind load. In this study, a structural analysis was performed on four types of vinyl houses(10-single-4, 10-single-6, 10-single-7, 10-single-10). In addition, axial force and flexural moment are obtained from the structural analysis of four types of vinyl house. For these four types of vinyl house, structural safety was reviewed by obtaining the combined stress ratio by the strength design method. This structural review showed that the specifications for the vinyl house proposed in the design are not safe. Especially, the result of structural analysis for four types of vinyl house showed that the vinyl house structure constructed as a standard was a very dangerous structure. Therefore, it is necessary to devise diverse methods in order to make vinyl houses structurally safe for heavy wind load in the future. Also a variety of manual development is needed to prevent the collapse of vinyl houses at heavy wind load.

Low strength concrete members externally confined with FRP sheets

  • Ilki, Alper;Kumbasar, Nahit;Koc, Volkan
    • Structural Engineering and Mechanics
    • /
    • v.18 no.2
    • /
    • pp.167-194
    • /
    • 2004
  • In this paper axial loading tests on low strength concrete members, which were confined with various thickness of carbon fiber reinforced polymer (CFRP) composite sheets are described. Totally 46 specimens with circular, square and rectangular cross-sections with unconfined concrete compressive strengths between 6 and 10 MPa were included in the test program. During the tests, a photogrammetrical deformation measurement technique was also used, as well as conventional measurement techniques. The contribution of external confinement with CFRP composite sheets to the compressive behavior of the specimens with low strength concrete is evaluated quantitatively, in terms of strength, longitudinal and lateral deformability and energy dissipation. The effects of width/depth ratios and the corner radius of the specimens with rectangular cross-section on the axial behavior were also examined. It was seen that the effectiveness of the external confinement with CFRP composite sheets is much more pronounced, when the unconfined concrete compressive strength is relatively lower. It was also found that the available analytical expressions proposed for normal or high strength concrete confined by CFRP sheets could not predict the strength and deformability of CFRP confined low strength concrete accurately. New expressions are proposed for the compressive strength and the ultimate axial strain of CFRP confined low strength concrete.

Improvement of the cyclic response of RC columns with inadequate lap splices-Experimental and analytical investigation

  • Kalogeropoulos, George I.;Tsonos, Alexander-Dimitrios G.
    • Earthquakes and Structures
    • /
    • v.16 no.3
    • /
    • pp.279-293
    • /
    • 2019
  • The overall seismic performance of existing pre 1960-70s reinforced concrete (RC) structures is significantly affected by the inadequate length of columns' lap-spliced reinforcement. Due to this crucial structural deficiency, the cyclic response is dominated by premature bond - slip failure, strength and stiffness degradation, poor energy dissipation capacity and low ductility. Recent earthquakes worldwide highlighted the importance of improving the load transfer mechanism between lap-spliced bars, while it was clearly demonstrated that the failure of lap splices may result in a devastating effect on structural integrity. Extensive experimental and analytical research was carried out herein, to evaluate the effectiveness and reliability of strengthening techniques applied to RC columns with lap-spliced reinforcement and also accurately predict the columns' response during an earthquake. Ten large scale cantilever column subassemblages, representative of columns found in existing pre 1970s RC structures, were constructed and strengthened by steel or RC jacketing. The enhanced specimens were imposed to earthquake-type loading and their lateral response was evaluated with respect to the hysteresis of two original and two control subassemblages. The main variables examined were the lap splice length, the steel jacket width and the amount of additional confinement offered by the jackets. Moreover, an analytical formulation proposed by Tsonos (2007a, 2019) was modified appropriately and applied to the lap splice region, to calculate shear stress developed in the concrete and predict if yielding of reinforcement is achieved. The accuracy of the analytical method was checked against experimental results from both the literature and the experimental work included herein.

Consideration of locked-in stresses during backfill preparation

  • Gezgin, Ahmet Talha;Cinicioglu, Ozer
    • Geomechanics and Engineering
    • /
    • v.18 no.3
    • /
    • pp.247-258
    • /
    • 2019
  • Soil strength and failure surface geometry directly influence magnitudes of passive earth thrust acting on geotechnical retaining structures. Accordingly, it is expected that as long as the shape of the failure surface geometry and strength parameters of the backfill are known, magnitudes of computed passive earth thrusts should be highly accurate. Building on this premise, this study adopts conventional method of slices for calculating passive earth thrust and combines it with equations for estimating failure surface geometries based on in-situ stress state and density. Accuracy of the proposed method is checked using the results obtained from small-scale physical retaining wall model tests. In these model tests, backfill was prepared using either air pluviation or compaction and different backfill relative densities were used in each test. When the calculated passive earth thrust magnitudes were compared with the measured values, it was noticed that the results were highly compatible for the tests with pluviated backfills. On the other hand, calculated thrust magnitudes significantly underestimated the measured thrust magnitudes for those tests with compacted backfills. Based on this observation, a new approach for the calculation of passive earth pressures is developed. The proposed approach calculates the magnitude and considers the influence of locked-in stresses that are the by-products of the backfill preparation method in the computation of lateral earth forces. Finally, recommendations are given for any geotechnical application involving the compaction of granular bodies that are equally applicable to physical modelling studies and field construction problems.

Application of self-centering wall panel with replaceable energy dissipation devices in steel frames

  • Chao, Sisi;Wu, Hanheng;Zhou, Tianhua;Guo, Tao;Wang, Chenglong
    • Steel and Composite Structures
    • /
    • v.32 no.2
    • /
    • pp.265-279
    • /
    • 2019
  • The self-centering capacity and energy dissipation performance have been recognized critically for increasing the seismic performance of structures. This paper presents an innovative steel moment frame with self-centering steel reinforced concrete (SRC) wall panel incorporating replaceable energy dissipation devices (SF-SCWD). The self-centering mechanism and energy dissipation mechanism of the structure were validated by cyclic tests. The earthquake resilience of wall panel has the ability to limit structural damage and residual drift, while the energy dissipation devices located at wall toes are used to dissipate energy and reduce the seismic response. The oriented post-tensioned strands provide additional overturning force resistance and help to reduce residual drift. The main parameters were studied by numerical analysis to understand the complex structural behavior of this new system, such as initial stress of post-tensioning strands, yield strength of damper plates and height-width ratio of the wall panel. The static push-over analysis was conducted to investigate the failure process of the SF-SCWD. Moreover, nonlinear time history analysis of the 6-story frame was carried out, which confirmed the availability of the proposed structures in permanent drift mitigation.