• Title/Summary/Keyword: lateral process

Search Result 771, Processing Time 0.033 seconds

Stiffness-based Optimal Design of Shear Wall-Frame Structure System using Sensitivity Analysis (민감도 해석을 이용한 전단벽-골조 구조시스템의 강성최적설계)

  • Lee Han-Joo;Kim Ho-Soo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.63-71
    • /
    • 2006
  • This study presents the effective stiffness-based optimal technique to control Quantitatively lateral drift for shear wall-frame structure system using sensitivity analysis. To this end, the element stiffness matrices are constituted to solve the compatibility problem of displacement degree of freedom between the frame and shear wall. Also, lateral drift constraint to introduce the approximation concept that can preserve the generality of the mathematical programming and can effectively solve the large scaled problems is established. And, the section property relationships for shear wall and frame members are considered in order to reduce the number of design variables and differentiate easily the stiffness matrices. Specifically, constant-shape assumption which is uniformly varying in size during optimal process is applied in frame structure. The thickness or length of shear wall can be changed depending on user's intent. Two types of 20 story shear wall-frame structure system are presented to illustrate the features of the stiffness-based optimal design technique.

Experimental Study of Strength and Ductility on Masonry Wall Frame and Shear Wall Frame Subjected to Cyclic Lateral Loading (반복-횡력을 받는 조적벽 골조와 전단벽 골조의 내력 및 연성에 관한 실험적 연구)

  • Lee, Ho;Byeon, Sang-Min;Jung, Hwan-Mok;Lee, Taick-Oun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.2
    • /
    • pp.83-91
    • /
    • 2013
  • The core aim of this dissertation is to empirically scrutinize a strength characteristic of beam-column frame subjected to the cyclic lateral load, a beam-column frame of un-reinforced masonry wall, and a shear wall frame. First and foremost, I embark upon making three prototypes vis-$\grave{a}$-vis this research. By conducting this process, I touch on an analysis of cyclic behavior and a damage characteristic of the beam-column frame, the beam-column frame of un-reinforced masonry wall, and the shear wall frame. What is more, through the previous procedure, the next part delves into the exact stress transfer path and the destructive mechanism to examine how much and how strong the beam-column frame of un-reinforced Masonry Wall does have a resistance capacity against earthquake in all the architecture constructed by the above-mentioned frame, as well as school buildings. In addition to the three prototypes, two more experimental models, a beam-column frame and shear wall frame, are used to compare with the beam-column frame of un-reinforced masonry wall. Lastly, the dissertation will suggest some solutions to improve the resistance capacity against earthquake regarding all constructions built with non bearing wall following having examining precisely all the analysis with regard to not only behavior properties and the damage mechanism of the beam-column frame and the beam-column frame of un-reinforced Masonry Wall but also the resistance capacity against earthquake of non bearing wall and school buildings.

Stable lateral-shearing interferometer for in-line inspection of aspheric pick-up lenses (생산 라인에서의 광 Pick-up용 비구면 대물 렌즈 측정을 위한 안정된 층밀리기 간섭계)

  • 조우종;김병창;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.3
    • /
    • pp.189-193
    • /
    • 1997
  • Aspheric pick-up lenses are increasingly used in consumer products such as computer and multimedia, as their mass production has become possible owing to the injection molding process. However still much work needs to be done for more effective manufacture of aspheric lenses, one area of which is the in-line inspection of produced lenses. In this paper, we present a lateral-shearing interferometer that has specially been designed to have a high immunity to external vibration and atmospheric disturbance. The interferometer comprises four prisms. They are directly attached to each other using an immersion oil so that relative sliding motions between the prisms are allowed. Their relative displacement can readily generate necessary lateral-shearing and phase-shifting to determine the wavefront of the beam collimated by the lens under inspection. A special phase-measuring algorithm of arbitrary-bucket is adopted to compensate the phase-shifting error caused by the thickness reduction in the immersion oil. Zernike polynomial fitting has done for determinating quantitative aberration of aspheric pick-up lenses. The interferometer built in this work is robust to external mechanical vibration and atmospheric disturbance so that experimental results show that it has a repeatability of less than λ/100.

  • PDF

The Change of Flow Characteristics in Lateral Aneurysm Models for Different Coil Locations (코일 위치에 따른 측방 동맥류 내부 혈류 유동의 변화)

  • 이계한;송계웅;변홍식
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.5
    • /
    • pp.375-383
    • /
    • 2002
  • Aneurysm embolisation method using coils have been widely used. Micro coils are introduced via a small catheter, and are packed inside of aneurysm sac, which induces intraaneurysmal flow stagnation and thrombus formation. When partial blocking of an aneurysm is inevitable, the location of coils is important since it changes the flow patterns inside the aneurysm, which affect the embolisation process. We measured the flow field inside the partially blocked lateral aneurysm models in vitro, and tried to suggest the effective locations of coils for aneurysm embolisation. Velocity fields are measured using a particle image velocitimeter for different coil locations- proximal neck, distal neck, proximal dome and distal dome. Flow into the aneurysm sac was significantly reduced in the distally blocked models, and coils at distal neck blocked inflow more effectively comparing to those at distal dome. This study suggests that distal neck should be the most effective location for aneurysm embolisation.

Task-oriented Approach using Percussion Instruments in Chronic Stroke Patients Effect on Upper Limb Function: a Randomized Controlled Trial (타악기를 활용한 과제지향운동이 만성 뇌졸중 환자의 상지 기능에 미치는 영향)

  • Kim, Ju-Hak;Kim, Myoung-Kwon
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.16 no.4
    • /
    • pp.103-116
    • /
    • 2021
  • PURPOSE: This study examined the effects on the upper extremity function, muscle strength, and hand function of a task-oriented training approach using a percussion instrument for patients with chronic stroke. METHODS: Twenty-four chronic stroke patients accompanied with upper extremity hemiplegia were selected for research and were classified randomly into 12 experimental groups and 12 control groups. The experimental group performed a task-oriented approach, and the control group performed upper extremity occupational therapy. Stroke upper extremity test, Jebsen-Taylor Hand Function test, upper extremity muscle strength test, and hand muscle strength test were measured before and after training in the evaluation process. RESULTS: In the upper extremity test and Jebsen-Taylor test, there were no significant differences between the groups. In the upper extremity muscle strength test, there were significant differences in shoulder flexion, internal rotation, and elbow flexion in the experimental group. In the hand muscle strength test, there were significant differences in the grip, tip Pinch, lateral Pinch, and 3-jaw chuck in the experimental group and significant differences in only grip, tip pinch, and lateral pinch in the control group. In addition, there were significant differences in the lateral pinch compared to the amount of change. CONCLUSION: Task-oriented approach using percussion instruments for upper extremity rehabilitation in stroke patients is effective in the upper extremity function and strength, hand function, and strength.

Experimental and finite element analyses of eccentric compression of basalt-fiber reinforced recycled aggregate concrete-filled circular steel tubular stub column

  • Zhang, Xianggang;Zhang, Songpeng;Yang, Junna;Chen, Xu;Zhou, Gaoqiang
    • Steel and Composite Structures
    • /
    • v.42 no.5
    • /
    • pp.617-631
    • /
    • 2022
  • To study the eccentric compressive performance of the basalt-fiber reinforced recycled aggregate concrete (BFRRAC)-filled circular steel tubular stub column, 8 specimens with different replacement ratios of recycled coarse aggregate (RCA), basalt fiber (BF) dosage, strength grade of recycled aggregate concrete (RAC) and eccentricity were tested under eccentric static loading. The failure mode of the specimens was observed, and the relationship curves during the entire loading process were obtained. Further, the load-lateral displacement curve was simulated and verified. The influence of the different parameters on the peak bearing capacity of the specimens was analyzed, and the finite element analysis model was established under eccentric compression. Further, the design-calculation method of the eccentric bearing capacity for the specimens was suggested. It was observed that the strength failure is the ultimate point during the eccentric compression of the BFRRAC-filled circular steel tubular stub column. The shape of the load-lateral deflection curves of all specimens was similar. After the peak load was reached, the lateral deflection in the column was rapidly increased. The peak bearing capacity decreased on enhancing the replacement ratio or eccentric distance, while the core RAC strength exhibited the opposite behavior. The ultimate bearing capacity of the BFRRAC-filled circular steel tubular stub column under eccentric compression calculated based on the limit analysis theory was in good agreement with the experimental values. Further, the finite element model of the eccentric compression of the BFRRAC-filled circular steel tubular stub column could effectively analyze the eccentric mechanical properties.

Microdevice for Separation of Circulating Tumor Cells Using Embedded Magnetophoresis with V-shaped Ni-Co Nanowires and Immuno-nanomagnetic Beads

  • Park, Jeong Won;Lee, Nae-Rym;Cho, Sung Mok;Jung, Moon Youn;Ihm, Chunhwa;Lee, Dae-Sik
    • ETRI Journal
    • /
    • v.37 no.2
    • /
    • pp.233-240
    • /
    • 2015
  • The novelty of this study resides in a 6"-wafer-level microfabrication protocol for a microdevice with a fluidic control system for the separation of circulating tumor cells (CTCs) from human whole blood cells. The microdevice utilizes a lateral magnetophoresis method based on immunomagnetic nanobeads with anti-epithelial cell adhesive molecule antibodies that selectively bind to epithelial cancer cells. The device consists of a top polydimethylsiloxane substrate for microfluidic control and a bottom substrate for lateral magnetophoretic force generation with embedded v-shaped soft magnetic microwires. The microdevice can isolate about 93% of the spiked cancer cells (MCF-7, a breast cancer cell line) at a flow rate of 40/100 mL/min with respect to a whole human blood/buffer solution. For all isolation, it takes only 10 min to process 400 mL of whole human blood. The fabrication method is sufficiently simple and easy, allowing the microdevice to be a mass-producible clinical tool for cancer diagnosis, prognosis, and personalized medicine.

A Study on the Fabrication and Electrical Characteristics of High-Voltage BCD Devices (고내압 BCD 소자의 제작 및 전기적 특성에 관한 연구)

  • Kim, Kwang-Soo;Koo, Yong-Seo
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.37-42
    • /
    • 2011
  • In this paper, the high-voltage novel devices have been fabricated by 0.35 um BCD (Bipolar-CMOS-DMOS) process. Electrical characteristics of 20 V level BJT device, 30/60 V HV-CMOS, and 40/60 V LDMOS are analyzed. Also, the vertical/lateral BJT with the high-current gain and LIGBT with the high-voltage are proposed. In the experimental results, vertical/lateral BJT has breakdown voltage of 15 V and current gain of 100. The proposed LIGBT with the high-voltage has breakdown voltage of 195 V, threshold voltage of 1.5 V, and Vce, sat of 1.65 V.

Ultra low temperature polycrystalline silicon thin film transistor using sequential lateral solidification and atomic layer deposition techniques

  • Lee, J.H.;Kim, Y.H.;Sohn, C.Y.;Lim, J.W.;Chung, C.H.;Park, D.J.;Kim, D.W.;Song, Y.H.;Yun, S.J.;Kang, K.Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.305-308
    • /
    • 2004
  • We present a novel process for the ultra low temperature (<150$^{\circ}C$) polycrystalline silicon (ULTPS) TFT for the flexible display applications on the plastic substrate. The sequential lateral solidification (SLS) was used for the crystallization of the amorphous silicon film deposited by rf magnetron sputtering, resulting in high mobility polycrystalline silicon (poly-Si) film. The gate dielectric was composed of thin $SiO_2$ formed by plasma oxidation and $Al_2O_3$ deposited by plasma enhanced atomic layer deposition. The breakdown field of gate dielectric on poly-Si film showed above 6.3 MV/cm. Laser activation reduced the source/drain resistance below 200 ${\Omega}$/ㅁ for n layer and 400 ${\Omega}$/ㅁ for p layer. The fabricated ULTPS TFT shows excellent performance with mobilities of 114 $cm^2$/Vs (nMOS) and 42 $cm^2$/Vs (pMOS), on/off current ratios of 4.20${\times}10^6$ (nMOS) and 5.7${\times}10^5$ (PMOS).

  • PDF

Verification of Vibration Test System for Geostationary Satellite (정지궤도위성 진동시험을 위한 가진 시스템 검증)

  • Im, Jong-Min;Moon, Sang-Moo;Eun, Hee-Kwang;Moon, Nam-Jin;Lee, Dong-Woo;Moon, Guee-Won
    • Aerospace Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.143-152
    • /
    • 2010
  • Development and verification of whole vibration test system was requested for developing a geostationary satellite. This satellite is enlarged significantly compared with fore-satellite in KARI. For vertical vibration test, new vertical vibration system was developed. For lateral vibration test, thermal equilibrium test was performed because of difference of thermal characteristics between test adapter and slip table. And lateral vibration system performance for overturning moment was verified by analysis and test. As the number of acquisition channels was increased, new shaker control and data acquisition system was installed. In this paper, verification process and techniques to improve test stability are introduced for the whole vibration test system.