• Title/Summary/Keyword: lateral force distribution

Search Result 127, Processing Time 0.029 seconds

Comparison of the Contact Area, Maximum Pressure, Maximum Average Pressure and Maximum Force between Functional Insoles and General Insoles (기능성 인솔과 일반 인솔의 발에 대한 접촉 면적, 최대 압력, 최대 평균압력 및 최대 힘 비교)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.431-441
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the changes in the contact area, maximum pressure, maximum mean pressure, and maximum force of functional insoles and general insoles when walking. Methods: Foot pressure was measured by the ignition of functional insoles and general insoles on Company N shoes. The foot pressure was measured using a precision pressure distribution meter (Pedar - X mobile system, Novel, Germany). Each insole sensor contained 99 independent cells and was inserted between the foot and the shoe. A wireless Bluetooth-type program was used to measure the pressure detected by the measuring insoles. In order to eliminate adaptation and fatigue caused by wearing the guide during the experiment, sufficient rest was taken between each experiment, and the wearing order was randomly selected. Results: Functional insole significantly increased the forefoot and midfoot (medial, lateral) (p<0.05), while total foot, forefoot, and rearfoot peak pressure significantly decreased (p < 0.05) compared to the general insole. Conclusion: In the functional insole, a high contact area was measured inside, even in the middle of the foot, leading to a proper change in foot pressure. It was confirmed that the contact area was reduced and dispersion occurred well. In addition, it was found that the maximum pressure in the front and back of the entire foot was reduced, so the weight pressure dispersion in the functional insole was evenly distributed, and the maximum average pressure change was similar.

A Study on the Rock Pressure Wedge Failure During Ground Excavation (대규모 지하굴착시 쐐기파괴로 인하여 발생하는 토압에 관한 연구)

  • 이승호
    • The Journal of Engineering Geology
    • /
    • v.11 no.1
    • /
    • pp.1-11
    • /
    • 2001
  • The geological characteristics of Korea are that we can encounter the rock layer only after 10m of excavation, methods to presume the rock pressure distribution of the rock layer is urgently needed. When using the existing empiric science of Terzaghi-Peck, Tschebotarioff to measure the rock pressure of the rock layer, underestimate the real strength because of the cohesion is ignored. Therefore calculating the horizontal sliding force of wedge block, which includes the dips and shear strength of discontinuities and surcharge load etc., think to be to getting a closer rock stress of the real rock pressure acting upon the earth structure in rock mass. This research use Coulomb soil pressure theory assuming that the backfill soil will yield wedge failure when it has cohesion, applying Prakash-Saran(l963), and then it uses equilibrium of force and shear strength $\tau$=c+$\sigma$tan $\Phi$ of the cliscontinuities. Analyzing shear strength and dips of cliscontinuities using calculated theory according to the status of discontinuities aperture, we were able to find out that because the cohesion and friction angle of the rock layer itself is large enough, how the dip directions and dips facing the excavation face is the only factor deciding whether or not the rock stress is applied. The evaluated theory of this research should be strictly estimated, so that the many parameters such as c, $\Phi$value, types and structures of rock class, excessive lateral pressure, dynamic load, earthquake, needed later when calculating shear strength of discontinuities and especially the ground water effect acting on rock layer should be coumpted with many measuring data achieve at the insite to study the application.

  • PDF

Seismic behavior of K-type eccentrically braced frames with high strength steel based on PBSD method

  • Li, Shen;Wang, Chao-yu;Li, Xiao-lei;Jian, Zheng;Tian, Jian-bo
    • Earthquakes and Structures
    • /
    • v.15 no.6
    • /
    • pp.667-685
    • /
    • 2018
  • In eccentrically braced steel frames (EBFs), the links are fuse members which enter inelastic phase before other structure members and dissipate the seismic energy. Based on the force-based seismic design method, damages and plastic deformations are limited to the links, and the main structure members are required tremendous sizes to ensure elastic with limited or no damage. Force-based seismic design method is very common and is found in most design codes, it is unable to determine the inelastic response of the structure and the damages of the members. Nowadays, methods of seismic design are emphasizing more on performance-based seismic design concept to have a more realistic assessment of the inelastic response of the structure. Links use ordinary steel Q345 (the nominal yielding strength $f_y{\geq}345MPa$) while other members use high strength steel (Q460 $f_y{\geq}460MPa$ or Q690 $f_y{\geq}690MPa$) in eccentrically braced frames with high strength steel combination (HSS-EBFs). The application of high strength steels brings out many advantages, including higher safety ensured by higher strength in elastic state, better economy which results from the smaller member size and structural weight as well as the corresponding welding work, and most importantly, the application of high strength steel in seismic fortification zone, which is helpful to popularize the extensive use of high strength steel. In order to comparison seismic behavior between HSS-EBFs and ordinary EBFs, on the basis of experimental study, four structures with 5, 10, 15 and 20 stories were designed by PBSD method for HSS-EBFs and ordinary EBFs. Nonlinear static and dynamic analysis is applied to all designs. The loading capacity, lateral stiffness, ductility and story drifts and failure mode under rare earthquake of the designs are compared. Analyses results indicated that HSS-EBFs have similar loading capacity with ordinary EBFs while the lateral stiffness and ductility of HSS-EBFs is lower than that of EBFs. HSS-EBFs and ordinary EBFs designed by PBSD method have the similar failure mode and story drift distribution under rare earthquake, the steel weight of HSS-EBFs is 10%-15% lower than ordinary EBFs resulting in good economic efficiency.

Behavior of Floating Top-Base Foundation on Soft Soils by Laboratory Model Tests (실내모형실험을 통한 연약지반에서 부양형 팽이기초의 거동)

  • Chung, Jin-Hyuck;Chung, Hye-Kwun;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.5-15
    • /
    • 2011
  • This research performed the laboratory model tests for Top-Base Foundation developed in Japan and Floating Top-Base Foundation developed in Korea on the typical clayey soft soils, namely, clay, clayey silt and clayey sand. The performances of the two types of top-base foundation were compared with each other and evaluated by measuring load-settlement, heaving of foundation side, ground stress distribution in this model tests. The change of settlement caused by the increase of top base width was also analyzed. As a result of the model tests, Floating Top-Base Foundation showed better performance in bearing capacity improvement, settlement decrease, stress dispersion effect and lateral confinement force. And settlement caused by the increase of top base width converged to a regular value from $5{\times}5$ layout of the width.

A Finite Element Analysis of Stress Distribution in the Temporomandibular Joints Following the Teeth Loss (치아결손이 측두하악관절의 응력분포에 미치는 영향에 관한 유한요소법적 분석)

  • Woo-Cheon Kee;Jae-Kap Choi;Jae-Hyun Sung
    • Journal of Oral Medicine and Pain
    • /
    • v.16 no.1
    • /
    • pp.33-72
    • /
    • 1991
  • The purpose of this study was to investigate the stress distribution and the displacement in the temporomandibular joints following the teeth loss patterns. The three dimensional finite element method was used for a mathematical model. The finite element model was composed of 1,632 elements and 2,411 nodes in the mandible with articular disc and mandibular fossa of the temporal bone. The masseter, the temporal and the internal pterygoid muscle forces were applied at each insertion site, bisecting point of gonion and antegonion, tip of the coronoid process, and gonion at the ration of 2:2:1 respectively. The directions of muscles force were obtained from frontal and lateral cephalometric tracings using bony landmarks of the skull. The results were as follows : 1. In control model, the minimum principal stresses were concentrated on the region of anterosuperior part of the condyle head and articular disc, and maximum principal stresses on the anterior part of the condyle head and posterolateral part of the articular disc. 2. In case of unilateral teeth loss, the greater principal stress appeared at the teeth loss side and the principal stresses increased at the teeth loss side as the number of the posterior teeth loss went up. 3. In case of bilateral teeth loss, the principal stresses were greater than those of the control model and as the number of the posterior teeth loss increased, the grater principal stresses on the temporomandibular joints appeared at the both side. 4. When the posterior teeth existed bilateral, the principal stress patterns were similar to those of the control model. 5. The displacement ws directed mainly upward and backward in the upper part of the temporomandibular joints and upward and forward in the largest part of the condyle head. The displacement increased as the number of the posterior teeth loss went up.

  • PDF

A PHOTOELASTIC STUDY OF THE STRESS DISTRIBUTION ON THE MULTILOOP EDGEWISE ARCH WIRE (Multiloop Edgewise Arch Wire의 응력분포에 대한 광탄성학적 연구)

  • Lee, Sheung-Ho;Kim, Jeong-Gee
    • The korean journal of orthodontics
    • /
    • v.24 no.4 s.47
    • /
    • pp.969-982
    • /
    • 1994
  • This study was designed to investigate the stress distribution, intensity and force mechanism derived from the MEAW by photoelastic stress analysis of the artificial teeth and surrounding bone composed of photoelastic material(PL-3) The findings of this study were as follows, 1. In case of no elastic on the MEAW with tip back, the moderate stress was observed on the molar and canine area, and the light stress was observed on the other area. 2. In case of the vertical elastic on the plain A.W, and the MEAW without tip back, the great stress was observed on the lateral incisor area, but on the MEAW with tip back, the moderate stress was observed on the anterior area and molar area. 3. In case of the C III elastic on plain A.W., the stress was concentrated on the anterior area hanged by elastic but on the MEAW without tip back, the stress was transmitted equally from the anterior area to the posterior teeth area. On the MEAW with tip back, the great stress was observed on the anterior and molar area. 4. In case of the C III elastic on the plain A.W., the stress was concentrated on the posterior area hanged by elastic but on the MEAW without tip back, the stress was transmitted equally from the posterior area to the anterior area. On the MEAW with tip back, the great stress was observed on the posterior area and the moderate stress was observed on the anterior area.

  • PDF

Effect of soil in controlling the seismic response of three-dimensional PBPD high-rise concrete structures

  • Mortezaie, Hamid;Rezaie, Freydoon
    • Structural Engineering and Mechanics
    • /
    • v.66 no.2
    • /
    • pp.217-227
    • /
    • 2018
  • In the last decades, valuable results have been reported regarding conventional passive, active, semi-active, and hybrid structural control systems on two-dimensional and a few three-dimensional shear buildings. In this research, using a three-dimensional finite element model of high-rise concrete structures, designed by performance based plastic design method, it was attempted to construct a relatively close to reality model of concrete structures equipped with Tuned Mass Damper (TMD) by considering the effect of soil-structure interaction (SSI), torsion effect, hysteresis behavior and cracking effect of concrete. In contrast to previous studies which have focused mainly on linearly designed structures, in this study, using performance-based plastic design (PBPD) design approach, nonlinear behavior of the structures was considered from the beginning of the design stage. Inelastic time history analysis on a detailed model of twenty-story concrete structure was performed under a far-field ground motion record set. The seismic responses of the structure by considering SSI effect are studied by eight main objective functions that are related to the performance of the structure, containing: lateral displacement, acceleration, inter-story drift, plastic energy dissipation, shear force, number of plastic hinges, local plastic energy and rotation of plastic hinges. The tuning problem of TMD based on tuned mass spectra is set by considering five of the eight previously described functions. Results reveal that the structural damage distribution range is retracted and inter-story drift distribution in height of the structure is more uniform. It is strongly suggested to consider the effect of SSI in structural design and analysis.

A Three-dimensional Photoelastic Analysis of Stress Distributions Around Osseointegrated Implants and Abutment Teeth According to Bridge Connecting Type (골유착성(骨癒着性) 임플란트와 치아간(齒牙間)의 보철물(補綴物) 연결(連結) 형태(形態)에 따른 주위(周圍) 골조직(骨組織)의 응력분산(應力分散)에 관한 3차원적(次元的) 광탄성(光彈成) 분석(分析))

  • Lee, Moo-Geon;Cho, Sung-Am
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.1
    • /
    • pp.120-147
    • /
    • 1994
  • This study was performed for the purpose of evaluating the stress distribution around threaded type implants, cylindrical type implants and teeth connected with rigid or non-rigid connector. The stress distribution around the surrounding bone was analyzed by three-dimensional photoelastic method. Twelve mandibular photoelastic epoxy resin models and a circular polariscope were used to record the isochromatic fringes. After the stress distribution around the implant and tooth was observed, the results were as follows ; 1. In threaded type implants, stress concentrated patterns were observed at the neck either vertical or 25 degree lateral force. 2. The stress concentrated patterns were observed at the tooth apical portion and neck portions of the implant and tooth when a threaded implant was connected with the tooth by either a rigid or non-rigid connector. More force was generated at the tooth neck portion by a rigid connector and more force at the implant neck portion by a non-rigid connector. 3. The stress concentrated patterns were observed at the apical portion of the implant and tooth when a cylindrical type ,implant was connected with the tooth either by a rigid or non-rigid connector. More force was generated at the tooth apical portion by a rigid connector and more force at the neck portion of the tooth and implant by a non-rigid connector. 4. The stress around the tooth was more equally distributed in a threaded type implant than in a cylindrical implant when the tooth was connected with either a rigid or non-rigid connector. 5. The stress around a threaded type implant was progressively more equally distributed in the following order : 1) when used a single implant, 2) a non-rigid connection with the implant and tooth, 3) a rigid connection with the implant and tooth, 4) a rigid connection with two implant fixtures.

  • PDF

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS (골내 임플랜트의 종류에 따른 광탄성 응력 분석)

  • Chung Chae-Heon;Chang Doo-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF THE UPPER ANTERIOR TEETH WHEN INTRUSIVE FORCE APPLIED (BY UTILITY ARCHWIRE, BURSTONE INTRUSION ARCHWIRE, and 'J' HOOK HEADGEAR) (상악 전치부 INTRUSION시 초기 응력 분포에 관한 광탄성학적 분석(Utility archwire Burstone intrusion archwire, 'J'hook headgear에 의한))

  • Baik, Hye-Jong;Baik, Hyoung-Seon
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.401-409
    • /
    • 1997
  • The purpose of this study was to analize the initial stress distribution around apex and the alveolar bone of the upper anterior teeth when applying intrusive force by the use of utility arthwire, Burstono 3-piece infusion archwire, and 'J' hook headgear which is usually used in clinital practice. By the use of the polarization plate, initial stresses were analized when 80g and 150g forte applied. The results were as follows. 1. With the utility archwire, moderate levels of stress were evenly distributed on the apical areas of the anterior teeth and concentrated on the apical areas of the first molars. 2. With the Burstone's 3-piece intrusion archwire, moderate levels of stress were evenly distributed on the apical areas of the anterior and posterior teeth. 3. With the 'J' hook headgear, severe levels oi stress were widely distributed on the alveolar bone and apical areas of the upper anterior teeth, and concentrated on the apical area between the central and the lateral incisors. Especially, weak levels of stress appeared along the periodontal ligament space of all teeth.

  • PDF