• Title/Summary/Keyword: lateral dose

Search Result 209, Processing Time 0.021 seconds

The Mentum Deformity of C. riparius Following Exposure to Bisphenol A and 4-nonylphenol (Bisphenol A와 4-nonylphenol에 노출된 C. riparius (Diptera: Chiromidae)의 하순기절 기형성)

  • Kwak, Inn-Sil;Lee, Won-Choel
    • Korean Journal of Environmental Biology
    • /
    • v.25 no.1
    • /
    • pp.66-71
    • /
    • 2007
  • The fourth instar larvae of C. riparius were treated with potential endocrine disruption chemicals (EDCs) such as bisphenol A (BPA) and 4-nonylphenol and the effects of morphological abnormalities were observed. The deformities of the mentum following exposure to EDCs showed the smooth tooth, the loss of tooth and deformed tooth. The incidence rates of the mentum deformity were associated with chemicals: BPA $31{\sim}90%$, and 4-nonlyphenol was $40{\sim}80%$. As the concentration of BPA increased, the incidence of deformed mentum was dose dependent. While the incidences of deformed mentum following exposure to 4-nonlyphenol was not associated with their concentrations. The deformed MLT observed smooth or round tooth and the deformity of LT showed loss of one or more than tooth. Also, the MIX type was usually smooth or loss tooth. The abundance of deformity type for the mentum showed MIX (MLT+LT) > LT (lateral teeth) > MLT (median lateral teeth).

A Study on Acute Delayed Neurotoxicity of KH-502, A Newly Synthesized Insecticide (새로운 합성 농약인 KH-502의 급성 지연성 신경독성 시험에 관한 연구)

  • 박재학;서광원;남기환;한상섭;이영순
    • Toxicological Research
    • /
    • v.13 no.4
    • /
    • pp.317-322
    • /
    • 1997
  • Acute delayed neurotoxicity of KH-502 [O.O-Diethyl O-(1-phenyyl-3-trifluoromethyl-5-pyrazoyl) thiophosphoric acid ester], an insecticide synthesized newly in Korea, was studied in White Leghorn hens. The doses were determined on the basis of preliminary $LD_{50}$ study. High, middle and low doses were determined to be 1123 mg/kg, 762 mg/kg and 518 mg/kg, respectively. The animals were pretreated with atropine (30 mg/kg) prior to administration of KH-502. The chemical was administrated at the first and 21st day of the study. As positive controls, animals were admlnistrated with triorthocresylphosphate (TOCP 1000 mg/kg and 500 mg/kg). Animals administrated with TOCP or KH-502 were sacrificed by perfusion-fixation at 21st and 42nd day of the study, respectively. The central and peripheral nerve tissues were routinely treated for microscopic observation. As results, eight, three, one, and one chickens died within 2 day after adminiatration with signs of cholinergic acute toxicity in high, middle low and TOCP dose-group (500 mg/kg), respectively. No abnormal clinical signs were observed in the survived chickens administrated with KH-502 in the duration of the study. The chickens in positive control groups showed ataxia and incoordination at the 14th day after administration of TOCP. From necropsy, macroscopic changes were not observed in all groups including positive control groups. Histopathologically, oxonal swelling with myelin loss, focal gliosis, distention around axonal space were observed in the spinal cords of the chickens administrated with TOCP 1000 mg/kg. The lesions were distinct in the dorsal and lateral funiculi of cervical spinal cord, in the lateral and ventral funiculi of thoracic spinal cord and in ventral funiculi of lumbosacral spinal cord. Axonal swelling and mlcrogliosis were infrequently observed in the chickens of other groups including negative control one. However, they were nonspecifically distributed in the spinal cords. In this study, we concluded that the new chemical, KH-502 did not have acute delayed neurotoxicity in White Leghorn hens.

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

A Study on the Optimization of Exposure condition at Lumbar projection Using Blind Test (블라인드 테스트를 통한 요추 검사 시 조사 조건의 최적화 연구)

  • Park, Jikoon;Kim, Kyotae;Yoon, Inchan;Choi, Ilhong;Jung, Hyungjin;Kang, Sangsik;Noh, Sicheul;Jung, Bongjae
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.389-395
    • /
    • 2013
  • This study intended to investigate the optimum conditions for lumbar test that has the highest level of irradiation conditions among general test sites. To to this, the most widely used irradiation conditions in terms of statistics were set as standards; test groups applied with DMF were selected; tests groups suitable for clinical trials were selected by using suggested patient dose. Blind tests were conducted by 10 specialists and radiologists. The results suggested that under the optimum conditions, the radiation dose reduction of 2.09 mGy, 4.42 mGy and 3.65 mGy can be achieved in forward-backward test, lateral test and 4-direction test, respectively. There is a need of further studies on the optimization of irradiation conditions in accordance with the conditions of patients.

AN EXPERIMENTAL STUDY OF THE EFFECT OF CO-60 IRRADIATION ON THE HEALING PROCESS OF EXTRACTION WOUNDS IN WHITE RATS (Co-60조사가 백서 발치창 치유과정에 미치는 영향에 관한 실험적 연구)

  • You Young Jun
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.12 no.1
    • /
    • pp.105-113
    • /
    • 1982
  • Because of the development of rampant caries, osteomyelitis and osteoradionecrosis that occur after radiation therapy of oral cancers, extraction of teeth at or near the malignant lesion has been done in the past. Few, however, have studied the radiation effect on the healing of extraction wounds. This study is concerned with the effect of Co-60 irradiation on the healing process of extraction wounds in rats. Fifty six, male, Spraque-Dawley rats are used. The right first molar of the mandible is extracted from all animals. They are divided into three experimental groups of 14 each and a control group of 14. Three experimental groups are irradiated respectively with 200 rad, 400 rad and 600 rad and a pair of rats in each group are killed on days 1, 3, 5, 7, 14, 21 and 28 after irradiation. Two animals from the control group are killed on the day when the experimental rats are killed. The irradiated hemimandibles are fixed in 10% neutral formalin, decalcified in 5% trichloroacetic acid, embedded in paraffin and sectioned. The sections are stained in hematoxylin and eosin, van Gieson, Masson's trichrome or silver nitrate. Results show that in general radiation effects on healing extraction wounds are dose dependent; i.e., the higher is the dose, the greater is the histologic changes observed: 1. Irradiation tends to retard blood clot organization and epithelial regeneration. 2. An increase in the number of giant cells and osteoclasts is noted after irradiation. 3. Formation of regenerating connective tissues around and within the extraction site is com- promised, and a clear reduction of primitive mesenchymal type connective cells is noted. 4. The healing process begins along the lateral aspect of the extraction socket in the control, while irregular histologic appearances of the brabecular pattern is present in the experimental rats.

  • PDF

The Influence of Air Cavity on Interface Doses for Photon Beams (X선치료 조사야 내 공동의 존재에 따른 선량분포의 측정)

  • Chung Se Young;Kim Young Bum;Kwon Young Ho;Kim You Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.69-77
    • /
    • 1998
  • When a high energy photon beam is used to treat lesions located in the upper respiratory air passages or in maxillary sinus, the beams often must traverse an air cavity before it reaches the lesion. Because of this traversal of air, it is not clear that the surface layers of the lesion forming the air-tumor tissue interface will be in a state of near electronic equilibrium; if they are not, underdosing of these layers could result. Although dose corrections at large distances beyond an air cavity are accountable by attenuation differences, perturbations at air-tissue interfaces are complex to measure or calculate. This problem has been investigated for 4MV and 10MV X-ray beams which are becoming widely available for radiotherapy with linear accelerator. Markus chamber was used for measurement with variouse air cavity geometries in X-ray beams. Underdosing effects occur at both the distal and proximal air cavity interface. The magnitude depended on geometry, energy, field sizes and distance from the air-tissue interfaces. As the cavity thickness increased, the central axis dose at the distal interface decreased. Increasing field size remedied the underdosing, as did the introduction of lateral walls. Fellowing a $20{\times}2{\times}2\;cm^3$\;air\;cavity,\;4{\times}4\;cm\;field\;there\;was\;an\;11.5\%\;and\;13\%\;underdose\;at\;the\;distal\;interface,\;while\;a\;20{\times}20{\times}2\;cm^3\;air\;cavity\;yielded\;a\;24\%\;and\;29\%$ loss for the 4MV and 10MV beams, respectively. The losses were slightly larger for the 10MV beams. The measurements reported here can be used to guide the development of new calculation models under non-equilibrium conditions. This situation is of clinical concern when lesions such as larynx and maxillary carcinoma beyond air cavities are irradiated.

  • PDF

26-Week Repeated Dose Oral Toxicity Study of KCHO-1 in Sprague-Dawley Rats

  • Yang, Muhack;Lee, Seongjin;Wang, Tingting;Cha, Eunhye;Jang, Jongwon;Kim, Dongwoung;Song, Bong-Keun;Son, Ilhong;Kim, Joonyup;Kang, Hyung Won;Kim, Sungchul
    • Journal of Pharmacopuncture
    • /
    • v.22 no.3
    • /
    • pp.192-199
    • /
    • 2019
  • Objectives: KCHO-1(Mecasin), also called Gamijakyakgamchobuja-tang originally, is a combination of some traditional herbal medicines in East Asia. This medicine has been used mainly for alleviating neuropathic pains for centuries in Korean traditional medicine. KCHO-1 was developed to treat pain, joint contracture and muscular weakness in patients with amyotrophic lateral sclerosis. This study was carried out to investigate the chronic toxicity of KCHO-1 oral administration in rats for 26 weeks. Methods: Sprague-Dawely rats were divided into four groups and 10 rats were placed in the control group and the high-dose group, respectively. Group 1 was the control group and the remaining groups were the experimental groups. In the oral toxicity study, 500 mg/kg, 1,000 mg/kg, and 2,000 mg/kg of KCHO-1 were administered to the experimental group, and 10 ml/kg of sterile distilled water was administered to the control group. Survival rate, body weight, feed intake, clinical signs, and visual findings were examined. Urinalysis, ophthalmologic examination, necropsy, organ weight, hematologic examination, blood chemical examination and histopathologic examination were performed. Results: Mortality and toxicological lesions associated with the administration of test substance were not observed in all groups. Conclusion: NOAEL(No observed adverse effect level) of KCHO-1 is higher than 2000 mg/kg/day. And, the above findings suggest that treatment with KCHO-1 is relatively safe.

Characteristics of radiographic images acquired with CdTe, CCD and CMOS detectors in skull radiography

  • Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Lopes, Sergio Lucio Pereira de Castro;Haiter-Neto, Francisco;Freitas, Deborah Queiroz
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.339-346
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the image quality, diagnostic efficacy, and radiation dose associated with the use of a cadmium telluride (CdTe) detector, compared to charge-coupled device (CCD) and complementary metal oxide semiconductor(CMOS) detectors. Materials and Methods: Lateral cephalographs of a phantom (type 1) composed of synthetic polymer filled with water and another phantom (type 2) composed of human skull macerated with polymer coating were obtained with CdTe, CCD, and CMOS detectors. Dosimeters placed on the type 2 phantom were used to measure radiation. Noise levels from each image were also measured. McNamara cephalometric analysis was conducted, the dentoskeletal configurations were assessed, and a subjective evaluation of image quality was conducted. Parametric data were compared via 1-way analysis of variance with the Tukey post-hoc test, with a significance level of 5%. Subjective image quality and dentoskeletal configuration were described qualitatively. Results: A statistically significant difference was found among the images obtained with the 3 detectors(P<0.05), with the lowest noise level observed among the images obtained with the CdTe detector and a higher subjective preference demonstrated for those images. For the cephalometric analyses, no significant difference (P>0.05) was observed, and perfect agreement was seen with regard to the classifications obtained from the images acquired using the 3 detectors. The radiation dose associated with the CMOS detector was higher than the doses associated with the CCD (P<0.05) and CdTe detectors(P<0.05). Conclusion: Considering the evaluated parameters, the CdTe detector is recommended for use in clinical practice.

Dose distribution at junctional area for head and neck radiotherapy (두경부 방사선치료시 접합 조사면의 선량분포)

  • 김정기;김기환;오영기;김진기;정동혁;신교철;양광모;조문준;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2001
  • For the head and neck radiotherapy, the technique of half beam using independent collimator is very useful to avoid overlapping of fields particularly when the lateral neck fields are placed adjacent to anterior supraclavicular field. Also abutting photon field with electron field is frequently used for the irradiation of posterior neck when tolerable dose on spinal cord has been reached. Using 6 MV X-ray and 9 MeV electron beams of Clinac1800(Varian, USA) linear accelerator, we performed film dosimetry by the X-OMAT V film of Kodak in solid water phantom and the dose distribution at beam center of 2 half beams further examined according to depths(0 cm, 1.5 cm, 3 cm, 5 cm) for single anterior half beam and anterior/posterior half beam. The dose distribution to the junction line between photon and electron fields was also measured. For the single anterior half beam, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 88%, 93% and 95% of open beam, respectively. In the anterior/posterior half beams, the absorption doses at 0.3 cm, 0.5 cm and 1 cm distances from beam center were 92%, 93% and 95% of open beam, respectively At the junction line between photon and electron fields, hot spot was developed on the side of the photon field and a cold spot was developed on that of the electron field. The hot spot in the photon side was developed at depth 1.5 cm with 7 mm width. The maximum dose of hot spot was increased to 6% of reference doses in the photon field. The cold spot in the electron side was developed at all measured depths(0.5 cm-3 cm) with 1-12.5 mm widths. The decreased dose in the cold spot was 4.5-30% of reference dose in the electron field. With above results, we concluded that when using electron beam or independent jaw for head and neck radiotherapy, the hot and cold dose area should be considered as critical point.

  • PDF

Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm (Pencil Beam 알고리즘 기반의 상용 치료계획 시스템을 이용한 전자선 회전 치료 계획의 구현 및 정확도 평가)

  • Kang, Sei-Kwon;Park, So-Ah;Hwang, Tae-Jin;Cheong, Kwang-Ho;Lee, Me-Yeon;Kim, Kyoung-Ju;Oh, Do-Hoon;Bae, Hoon-Sik
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.304-310
    • /
    • 2010
  • Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode, no commercial planning systems for the electron arc plan are available at this time. In this work, with the expectation that an easily accessible planning system could promote electron arc therapy, a commercial planning system was commissioned and evaluated for the electron arc plan. For the electron arc plan with use of a Varian 21-EX, Pinnacle3 (ver. 7.4f), with an electron pencil beam algorithm, was commissioned in which the arc consisted of multiple static fields with a fixed beam opening. Film dosimetry and point measurements were executed for the evaluation of the computation. Beam modeling was not satisfactory with the calculation of lateral profiles. Contrary to good agreement within 1% of the calculated and measured depth profiles, the calculated lateral profiles showed underestimation compared with measurements, such that the distance-to-agreement (DTA) was 5.1 mm at a 50% dose level for 6 MeV and 6.7 mm for 12 MeV with similar results for the measured depths. Point and film measurements for the humanoid phantom revealed that the delivered dose was more than the calculation by approximately 10%. The electron arc plan, based on the pencil beam algorithm, provides qualitative information for the dose distribution. Dose verification before the treatment should be mandatory.