• Title/Summary/Keyword: lateral branch

Search Result 209, Processing Time 0.154 seconds

Nerve Conduction Study of Lateral Dorsal Cutaneous Branch of Sural Nerve (비복신경 외측분지의 신경전도검사)

  • Kim, Sung-Je;Lee, Dong-Kuck
    • Annals of Clinical Neurophysiology
    • /
    • v.5 no.2
    • /
    • pp.192-196
    • /
    • 2003
  • The Lateral dorsal cutaneous branch of sural nerve (LDCB) is a terminal sensory branch of lower extremities. It can be injured frequently in peripheral nerves. However, the normal data of each component of nerve conduction study (NCS) of were not studied at this time. The Nerve Conduction Study of LDCB adults were assessed for amplitude, area, duration and nerve conduction velocity (NCV) in normal fifty. We also evaluated how age, sex and dexterity affect the various components of NCS. The Mean amplitude of LDCB was $9.45{\pm}1.93{\mu}V$, area was $4.05{\pm}0.55{\mu}V/s$, duration was $1.50{\pm}0.13s$, and NCV was $37.9{\pm}3.09m/s$, respectively. The amplitude of right was $10.1{\mu}V$ in men, $8.65{\mu}V$ in women. The area of right was $3.83{\mu}V/s$ in less than 40 years and $4.24{\mu}V/s$ in older than 40 years. The areas of left was $3.86{\mu}V/s$ in less than 40 years and $4.30{\mu}V/s$ in older than 40 years. The NCV was 39.0 m/s in less than 40 years and 36.7 m/s in older than 40 years. All of above differences were statistically significant. There were no statistically significant differences between right and left NCS. Normal data of LDCB could be applicable in peripheral neuropathy or nerve injury.

  • PDF

Reliability analysis of the switch installation in the main feeder and in the radial/loop lateral feeders in distribution system (간선 및 분기선의 개폐기 설치 효과 분석(II))

  • Cho, Nam-Hun;O, Jae-Hyeong;Lee, Heung-Ho;Ha, Bok-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.83-86
    • /
    • 2002
  • In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

  • PDF

The relationship between time-varying eccentricity of load with the corner lateral displacement response of steel structure during an earthquake

  • Takin, Kambiz;Hashemi, Behrokh H.;Nekooei, Masoud
    • Steel and Composite Structures
    • /
    • v.20 no.4
    • /
    • pp.801-812
    • /
    • 2016
  • In an actual design, none of the structures with shear behaviors will be designed for torsional moments. Any failure or damages to roofs, infills, shear walls, and braces caused by an earthquake, will inevitably result in relocation of center of mass and rigidity of the structure. With these changes, the dynamic characteristics of structure could be changed during an earthquake at any moment. The main objective of this paper is to obtain the relationship between time-varying eccentricity of load and corner lateral displacement. In this study, various methods have been used to determine the structural response for time-varying lateral corner displacement. As will be seen below, some of the structural calculation methods result in a significant deviation from the actual results, although these methods include the interaction effects of modes. Controlling the lateral displacement of structure can be performed in different ways such as, passive dampers, friction dampers, semi-active systems including the MR damper and active Systems. Selecting and locating these control systems is very important to bring the maximum safety with minimum cost into the structure. According to this study will be show the relation between the corner lateral displacements of structure and time-varying eccentricity by different kind of methods during an earthquake. This study will show that the response of the structure at the corners due to an earthquake can be very destructive and because of changing the eccentricity of load, calculating the maximum possible response of system can be carried out by this method. Finally, some kind of systems must be used for controlling these displacements. The results shows that, the CQC, DSC and exact methods is comply each other but the results of Vanmark method is not comfortable for these kind of buildings.

A new equation based on PGA to provide sufficient separation distance between two irregular buildings in plan

  • Loghmani, Adel;Mortezaei, Alireza;Hemmati, Ali
    • Earthquakes and Structures
    • /
    • v.18 no.5
    • /
    • pp.543-553
    • /
    • 2020
  • Past earthquakes experience shows that serious damage or collapse of buildings have dramatically accrued when sufficient separation distance has not been provided between two adjacent structures. The majority of past studies related to the pounding topic indicate that obtaining the gap size between two buildings is able to prevent collision and impact hazards during seismic excitations. Considering minimization of building collisions, some relationships have been suggested to determine the separation distance between adjacent buildings. Commonly, peak lateral displacement, fundamental period and natural damping as well as structural height of two adjacent buildings are numerically considered to determine the critical distance. Hence, the aim of present study is to focus on all mentioned parameters and also utilizing the main characteristic of earthquake record i.e. PGA to examine the lateral displacement of irregular structures close to each other and also estimate the sufficient separation distance between them. Increasing and decreasing the separation distance is inherently caused economical problems due to the land ownership from a legal perspective and pounding hazard as well. Therefore, a new equation is proposed to determine the optimum critical distance. The accuracy of the proposed formula is validated by different models and various earthquake records.

Evaluation of cyclic behavior of lateral load resisting system with eccentric brace and steel plate

  • Reza Khalili Sarbangoli;Ahmad Maleki;Ramin K. Badri
    • Structural Engineering and Mechanics
    • /
    • v.89 no.3
    • /
    • pp.239-252
    • /
    • 2024
  • Steel plate shear walls (SPSWs) are classified as lateral load-resisting systems. The feasibility of openings in the steel plate is a characteristic of SPSWs. The use of openings in SPSWs can lower the load capacity, stiffness, and energy dissipation. This study proposes a novel form of SPSWs that provides convenient access through openings by combining steel plates and eccentrically braced frames (EBFs). The proposed system also avoids a substantial reduction in the strength and stiffness. Hence, various geometric forms were analyzed through two different structural approaches. Groups 1, 2, and 3 included a steel EBF with a steel plate between the column and EBF in order to improve system performance. In Group 4, the proposed system was evaluated within an SPSW with openings and an EBF on the opening edge. To evaluate the performance of the proposed systems, the nonlinear finite element method (NL-FEM) was employed under cyclic loading. The hysteresis (load-drift) curve, stress contour, stiffness, and damping were evaluated as the structural outputs. The numerical models indicated that local buckling within the middle plate-EBF connection prevented a diagonal tension field. Moreover, in group 4, the EBF and stiffeners on the opening edge enhanced the structural response by approximately 7.5% in comparison with the base SPSW system.

A parametric investigation on the hysteretic behaviour of CFT column to steel beam connections

  • Esfandyary, R.;Razzaghi, M.S.;Eslami, A.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.1
    • /
    • pp.205-228
    • /
    • 2015
  • The results of a numerical investigation pertaining to the hysteretic behaviour of concrete filled steel tubular (CFT) column to I-beam connections are discussed in detail. Following the verification of the numerical results against the available experimental tests, the nonlinear finite element (FE) analysis was implemented to evaluate the effects of different parameters including the column axial load, beam lateral support, shape and arrangement of stiffeners, stiffness of T-stiffeners, and the number of shear stiffeners. Pursuing this objective, an external CFT column to beam connection, tested previously, was selected as the case-study. The lateral forces on the structure were simulated, albeit approximately, using an incremental cyclic loading reversal applied at the beam tip. The results were compared in terms of hysteretic load-displacement curves, stress distributions in connection, strength, rotation, and energy dissipation capacity. It was shown that external T-stiffeners combined with internal shear stiffeners play an important role in the hysteretic performance of CFT columns to I-beam connections.

Controlling the lateral displacement of building with external lever by using of MR damper

  • Takin, Kambiz;Hashemi, Behrokh Hosseini;Nekooei, Masoud
    • Earthquakes and Structures
    • /
    • v.13 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • This article is all about using the MR damper with an external lever system for mitigation torsional and transitional lateral displacements by using of PID control algorithm. The torsional modes are so destructive and can be varied during an earthquake therefore, using a semi-active control system mostly recommended for them. In this paper the corner lateral displacement of each floor obtains and then it equivalents in a solid member and it connects to an MR damper, which relies to a rigid structure to reduce the response. An MR damper is a semi-active control system, which can absorb a lot of energy by injecting current to it. This amount of current is very low and needs low power supply, but it increases the amount of damper force, rather than inactive systems like viscous dampers. This paper will show the appropriate algorithm for current injection into MR damper when the eccentricity of the load is changed by using of Bouc-Wen and Bingham's methods and illustrates the coincidence of them.

Anatomy of the Sural Nerve in the Foot and Ankle and Its Surgical Implications (족부 및 족관절 부위에서 비복 신경의 해부학 및 수술시의 의미)

  • Lee, Woo-Chun;Park, Hyun-Soo;Han, Young-Kil;Chang, Byeong-Chun;Rim, Jang-Woon;Rha, Jong-Deuk
    • Journal of Korean Foot and Ankle Society
    • /
    • v.2 no.2
    • /
    • pp.88-92
    • /
    • 1998
  • The course of the sural nerve in the calf has been well documented, but there is a general lack of information concerning the distal course of the nerve. The purpose of this study was to describe the distal course of the sural nerve and its surgical implications. Seven fresh amputated specimens were dissected to show the anatomy of the sural nerve in the foot and ankle. At the level of about 10cm proximal to the plantar surface, the sural nerve coursed anteriorly and inferiorly away from the Achilles tendon. 2 to 4 lateral calcaneal branches arose. The first branch of the lateral calcaneal branches coursed along the lateral border of the Achilles tendon, and it arose at 8cm proximal to the plantar surface in 2 specimens, 12cm proximal to the plantar surface in 4 specimens, and at 12cm proximal to the plantar surface in one specimen. The main nerve trunk continued distally plantar to the peroneal tendons and divided into two terminal branches and crossed peroneus longus tendon at the level of the inferior border of the calcaneo-cuboid joint, at about 3cm(range, $2.5\sim3.0$)cm from the plantar surface. In conclusion, a longitudinal incision lateral to the Achilles tendon would cross the path of the sural nerve at about 10cm proximal to the plantar surface. When the first branch of them arise more than 10cm above the plantar surface, a logitudinal incision lateral to the Achilles tendon may be made without damage. The other lateral calcaneal branches will be cut when we make transverse incision paralled to the plantar surface. The terminal branch also may be in danger by the same transverse incision.

  • PDF

Temperature and Light Responses in Growth of Gracilaria verrucosa (Rhodophyta) and Its Potential for Mariculture in Korea

  • Kim Young Sik;Choi Han Gil;Kim Hyung Geun;Nam Ki Wan;Sohn Chul Hyun
    • Fisheries and Aquatic Sciences
    • /
    • v.5 no.2
    • /
    • pp.108-113
    • /
    • 2002
  • Apical and subapical fragments of Gracilaria verrucosa (Hudson) Papenfuss (Rhodophyta) were cultured on a temperature-light gradient table with four temperature $(15,\;20,\;25\;and\;30^{\circ}C)$ and five light intensity $(20,\;40,\;60,\;80\; and\;100{\mu}mol\;photons\;m^{-2}s^{-l})$ regimes to examine growth responses. Their growth was measured weekly. Plant weight and lateral branch formation were affected by temperature and light intensity. As compared with other reports, relative growth rate (RGR) in both fragments was more or less high with 6.27 to $11.95\%$ $day^{-1}$. It was lowest at $15^{\circ}C$ with $20\mu mol$ photons $m^{-2}s^{-l}$, whereas, the highest value was recorded at $25^{\circ}C$ with $100\mu mol$ photons $m^{-2}s^{-l}$ During the experimental period, the growth pattern in G. verrucosa was significantly different between apical and subapical fragments, even though RGR based on weight was similar. Growth in apical fragments depended on elongation by apical growth. By contrast, subapical fragments mainly increased their weights by proliferation of lateral branch. This suggests that intercalary activity (e.g. lateral branch formation) is also an important means for growth of the thallus in Korean G. verrucosa. In conclusion, the relatively high growth potential with the intercalary activity in G. verrucosa will be helpful for mariculture in Korea.

Vascular Variations in the Anterolateral Thigh Flap (전외측 대퇴부 피판의 혈관 변이)

  • Hwang, So Min;Kim, Min Wook;Lim, Kwang Ryeol;Jung, Yong Hui;Kim, Hyung Do;Kim, Hong Il
    • Archives of Reconstructive Microsurgery
    • /
    • v.22 no.1
    • /
    • pp.13-17
    • /
    • 2013
  • Purpose: Although a fasciocutaneous perforator artery as a vascular pedicle has previously been shown to be predominant in the anterolateral thigh (ALT) flap, recent studies have shown that a myocutaneous perforator artery is predominant. We have attempted to attain a clinical understanding of the vascular variations in the ALT flap. Materials and Methods: We confirmed the origin of a perforator artery in 11 cases of ALT flap. We then reviewed the variations of the descending branch of the lateral femoral circumflex artery, known as the major origin of the flap, and the overall variations associated with an ALT flap. Results: In a total of 11 cases, there were 18 perforator arteries of the ALT flaps. In addition, there were 9 fasciocutaneous perforator arteries and another 9 myocutaneous ones. However, depending on the origin, there was great variability in the perforator artery. That is, there were unique variants in the descending branches of the lateral femoral circumflex artery, the major origin of the perforator artery, in 3 of the total 11 cases. Conclusion: Our results showed that (1) a perforator artery accounts for the high proportion of fasciocutaneous ones, (2) a perforator artery might not originate from the descending branch of the lateral femoral circumflex artery and (3) there might be unique variants in the descending branch. If considering this, surgeons would successfully elevate an ALT flap.

  • PDF