• Title/Summary/Keyword: laser stimulation

Search Result 96, Processing Time 0.025 seconds

Studies on the Knee Joint Pain (무릎관절의 통증에 관한 연구)

  • Choe, Joon-Rieb;Lee, Hee-Jeon;Choe, Wook-Yoen;Han, Sang-Yoen
    • The Korean Journal of Pain
    • /
    • v.5 no.2
    • /
    • pp.249-257
    • /
    • 1992
  • It is general knowledge that knee joint pain can be attributed to trauma and degenerative change around the knee joint. However most patients who have suffered from pain or limited range of motion of the knee joint show no definite pathology on X-ray or laboratory examination. We examined 242 patients with knee joint pain and found compression or entrapment of the articular nerve fiber by the tissue around the knee joint resulted in pain in almost all cases. Conclusion: by relieving the compression of the articular nerve fiber with just physical therapy and LASER stimulation on the identified trigger points, in conjunction with NSAIDs, muscle relaxants, were found to be very effective in the treatment of knee joint pain.

  • PDF

Development of Laser Induced Real Time Photoacoustic Tomography Imaging System and Phantom Evaluation (레이저 유도방식의 실시간 광음향 단층영상 기술 개발과 팬텀이미지 평가)

  • Ryu, Sang-Hun;Shin, Dong-Ho;Song, Chul-Gyu
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.879-884
    • /
    • 2012
  • Photoacoustic Tomography (PAT) is a promising medical imaging modality by reason of its particularity. It combines optical imaging contrast of optical imaging with the spatial resolution of ultrasound imaging and can demonstrate change of biological feature in an image. For that reason, many studies are in progress to apply this technic for diagnosis. But, real-time PAT system is necessary to confirm a biological reaction induced by external stimulation immediately. Thus, we developed a real-time PAT system using linear array transducer and self-developed Data acquisition board (DAQ) resources, To evaluate the feasibility and performance of our proposed system, two type of phantom test were also performed. As a result of those experiments, the proposed system shows enough performance and confirm its usefulness.

The Pain of the Shoulder Joint and Posterolateral Area of Upper Arm (어깨관절과 상박부 통증에 대한 견해)

  • Kang, Yeong-Seon;Song, Chan-Woo
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.105-108
    • /
    • 1996
  • Localized or radiating pain in the arm and shoulder joint may result after faulty alignment causing compression or tension on nerves, blood vessels, or supporting soft tissues. The critical site of faulty alignment is the quadrangular space in the axilla bounded by the teres major, teres minor, long head of triceps, and humerus. The axillary nerve emerges through this space to supply the deltoid and teres minor. The activity of the trigger point on teres minor compressing the axillary nerve causes pain to develop through the area of sensory distribution of cutaneous branch of the axillary nerve. Relieving compression on the axillary nerve and suprascapular nerve is the key point to relieving the pain. Spasm of the supraspinatus and infraspinatus compressing the suprascapular nerve caused pain to develop in the shoulder joint and scapular area. We treated those patients experiencing such pain with local anesthetic infiltration or I-R laser stimulation on the identified trigger points.

  • PDF

Effects of Low-power Laser and TDP on the Cutaneous Wound Healing (피부상처 치유에 대한 저에너지레이저와 특정전자파의 효과)

  • Ahn So-Youn;Park Sang-Ock
    • The Journal of Korean Physical Therapy
    • /
    • v.9 no.1
    • /
    • pp.1-18
    • /
    • 1997
  • The purpose of this study is to investigate the effects of the low power Helium Neon-Infra Red(HeNe-IR) laser and the special electromagnetic therapeutic apparatus stimulation, which is usually designated as TDP by using the initial of Tending Diancibo Pu which is the Chinese inscribed with English, on wound healing in rat. The seventy-five Sprague-Dawley adult female and male rats were assigned to the experimental and control groups. Each rat was anesthetized with pentobarbital sodium, and three full-thickness incisions with 12mm length wert made on the back of the half cf the rats and three deep second degree burns were made on the back of the remainder of the rats. From 34 hours after being injured, the rats of the experimental laser group were irradiated with the 157mW electric power HeNe-IR laser for 2 minutes every day and the rats of the experimental TDP group were stimulated with TDP irradiation with the 4km spot distance for 20 minutes every day during the 17 days. The rats were sacrificed and the wound parts of its were incised on the first day, 4th day, 7th day, 10th day and 17th day respectively after the beginning of wound treatment with laser and TDP irradiation. The incised wound parts were processed appropriately for the light microscopic and electron microscopic examination. The length of incised wound was measured with microcaliper before the wound part was incised. There was a significant decrease in the length of the incised wound of the experimental laser and TDP group, compared with that of control group at 4th day, 7th day and 10th day(p<0.01) after surgery. Through the histological examination of the wound site, the more rapid epithelialization and collagen formation in experimental groups were showed, compared with control group. The histological results were analyzed and summarized as the follows; The epidermis begins to be regenerated and the granulation tissue begins to be changed to the mature pattern in the H-E stained incised skin of the laser and TDP treatment group on the 4th day. The epidermis shows the complete regeneration and the granulation tissue in the dermis in mostly to be matured in the laser and TDP treatment group on the 7th day, compared with control group. The chronic inflammatory cells are oberved and the necrosis of the collagen fibers are partially observed in control group on the 10th day. The dermis of the laser and TOP treatment group reveals relatively compactly arranged collgen bundles with the mature collagen fibers on the 10th day. The epidermis and dennis of the laser and TDP group are repaired normally and the hair follicles are well regenerated on the 17th day. The mild edema and the granulation tissue is observed in the dermis of the control groups and the delayed treatment process is observed on the 17th day. The Most of proliferated collagen fibrils are found to be compact and regular in electron micrograph of burn skin of the laser treatment group on the 10th day hut the interstitial eadema and some inflammatory cells are found in the control group. The above results suggest that through the visual and histological examination the epithelized epithelium and the proliferation of the collagen liters in the dermis occur very effectively with the low power laser treatment and the TDP treatment in the incised wound healing and the burn wound healing.

  • PDF

MEASUREMENT OF PULPAL BLOOD FLOW USING A LASER DOPPLER FLOWMETER (Laser Doppler flowmeter를 이용한 치수혈류 측정)

  • Ban, Tae-Whan;Lee, Jae-Sang;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.4
    • /
    • pp.560-569
    • /
    • 1999
  • Blood supply rather than nerve supply implies pulp vitality. To evaluate pulp vitality clinically, electric pulp test and thermal test which are based on sensory nerve response have been used in addition to many auxiliary data such as past dental history, visual inspection, radiographic examination, percussion, palpation and transillumination test. However, reactivity of the nerves to the stimulation is not synonymous with normalcy. Therefore measurement of pulpal blood flow using a laser Doppler flowmeter became a new trial to test the pulp vitality. The purpose of the present study was to evaluate normal pulpal blood flow level of maxillary teeth in adult to provide a guideline in determining the vitality of dental pulp. Pulpal blood flow was measured in maxillary central and lateral incisors, canines, first and second premolars and first molars of seventy nine adults of 22 - 30 years old using a laser Doppler flowmeter (PeriFlux 4001, Perimed Co., Stockholm, Sweden, 780 nm infrared laser, 1mW). For directly-made splints, silicone rubber impressions were taken directly from the mouth. For indirectly-made splints, alginate impressions were taken from the mouth and stone cast were made. After making depressions on the buccal surfaces of the cast teeth to indicate the hole positions, second impressions with vinyl polysyloxane putty were taken from the cast. Holes for the laser probes were made at the putty impressions 4mm above the gingival level. Laser probe (PF416 dental probe, 1.5mm) was inserted in the prepared hole and the splint was set in the mouth. After 10 minutes of patient relaxing, pulpal blood flow was recorded for 5 minutes on each tooth. The recorded flow was saved in the computer and calculated with a software 'Perisoft' version 5.1. Pulpal blood flow was also recorded in six teeth of five individuals with no response to electric pulp test and cold test, with periapical radiolucency, or with history of root canal treatment to compare with nonvital teeth. The difference between the mean flow values of each group of teeth were analyzed using one-way ANOVA and Duncan's Multiple Range test. The results were as follows: 1. The average pulpal blood flow values of all the tested teeth of each location were between 9 - 16 Perfusion Unit. Pulpal blood flow value was highest in maxillary lateral incisors, followed by first premolars, second premolars, canines, central incisors, and then first molars (p<0.01). 2. In six anterior teeth, indirectly-made splint group showed higher pulpal blood flow values than directly-made splint group (p<0.01). In posterior teeth, however, there was no significant flow value difference between directly-made splint group and indirectly-made splint one (p>0.05). 3. Teeth with vital pulps showed higher signal values than teeth with nonvital pulps (p<0.01), and the flow photographs showed heartbeat-synchronous fluctuations and vasomotions, while those were absent in non vital tooth.

  • PDF

PULSE OXIMETER AS A DIAGNOSTIC TEST OF PULP VITALITY (Pulse Oximeter를 이용한 치수생활력측정)

  • Koo, Bon-Kyung;Lee, Jae-Ho;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2000
  • Traditionally, EPT and thermal tests were used as diagnostic methods for pulp vitality test. The thermal and electrical stimulation tests are the methods to determine the vitality of a tooth based on its neuronal response. These have certain limitations, one of them is the difficulty of approaching the correct result in case of treatment of children. The reason is management problem caused by the unpleasant stimulation. Also, the response from patients are not objective, and false positive or false negative could be happened. Recently, laser doppler flowmetry and pulse oximeter which evaluate vascular integrity are introduced in an effort of overcoming to limitation of traditional methods. The principle of pulse oximeter is to and out level of oxygen saturation by ratio of the two pulses between emitted light and detected light penetrating them to the termination of body, such as ears or fingers. From this point of view, it can be applied to a tooth to determine its vitality. The objective of this study lies mainly on varifying pulse oximeter as a method of determining tooth vitality and providing basic data of its clinical implementation. The result of the research showed that level of oxygen saturation in vital teeth was average of 96.3% and 0.0% in pulpless teeth. As a comprehensive result, pulse oximeter could be an useful diagnostic equipment in determining of tooth vitality.

  • PDF

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

Deletion of adipose triglyceride lipase abolishes blood flow increase after β3-adrenergic stimulation in visceral adipose tissue of mice

  • Lee, Hye-Jin;Jin, Bo-Yeong;Park, Mi-Rae;Seo, Kwan Sik;Jeong, Yong Taek;Choi, Sang-Hyun;Kim, Dong-Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.25 no.4
    • /
    • pp.355-363
    • /
    • 2021
  • Dynamic changes in adipose tissue blood flow (ATBF) with nutritional status play a role in the regulation of metabolic and endocrine functions. Activation of the sympathetic nervous system via β-adrenergic receptors (β-AR) contributes to the control of postprandial enhancement of ATBF. Herein, we sought to identify the role of each β-AR subtype in the regulation of ATBF in mice. We monitored the changes in visceral epididymal ATBF (VAT BF), induced by local infusion of dobutamine, salbutamol, and CL316,243 (a selective β1-, β2-, and β3-AR agonist, respectively) into VAT of lean CD-1 mice and global adipose triglyceride lipase (ATGL) knockout (KO) mice, using laser Doppler flowmetry. Administration of CL316,243, known to promote lipolysis in adipocytes, significantly increased VAT BF of CD-1 mice to a greater extent compared to that of the vehicle, whereas administration of dobutamine or salbutamol did not produce significant differences in VAT BF. The increase in VAT BF induced by β3-AR stimulation disappeared in ATGL KO mice as opposed to their wild-type (WT) littermates, implying a role of ATGL-mediated lipolysis in the regulation of VAT BF. Different vascular reactivities occurred despite no significant differences in vessel density and adiposity between the groups. Additionally, the expression levels of the angiogenesis-related genes were significantly higher in VAT of ATGL KO mice than in that of WT, implicating an association of ATBF responsiveness with angiogenic activity in VAT. Our findings suggest a potential role of β3-AR signaling in the regulation of VAT BF via ATGL-mediated lipolysis in mice.

Fabrication of Biomimetic MEMS Acoustic Sensor and Analysis of Its Frequency Characteristics (MEMS 기반 생체모사 음향센서 제작 및 주파수 특성 분석)

  • Hur, Shin;Jung, Young-Do;Lee, Young-Hwa;Song, Won-Joon;Kim, Wan-Doo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.522-528
    • /
    • 2011
  • Artificial basilar membranes made of PVDF(polyvinylidene fluoride) are manufactured using microfabrication processes. The mechanical behavior of PVDF artificial basilar membrane was measured to evaluate its performance as a mechanical frequency analyzer using scanning LDV(laser Doppler vibrometer). The experimental setup consists of the microfabricated artificial basilar membrane, a loud speaker connected to an amplifier for generating acoustic pressure of specific spectral pattern, and a scanning LDV with controlling unit for measuring the displacement of the membrane on the incoming acoustic stimulation. The microfabricated artificial basilar membrane was attached tightly upon a package containing a chamber which can be filled with silicone oil before placed on the experimental setup stage. The experiment results showed that the microfabricated artificial basilar membrane has a property as a mechanical frequency analyzer.

In Vitro Development of Porcine Oocytes Following Intracytoplasmic Injection of Round Spermatid (원형정자 미세주입에 의한 돼지 난자의 체외 배 발달)

  • Shin J. S.;Kim, C.;S. J. Uhm;Kim, N. H.;Lee, H. T.;K. S. Chung
    • Korean Journal of Animal Reproduction
    • /
    • v.22 no.4
    • /
    • pp.395-403
    • /
    • 1998
  • In this study we determined fertilization processes and developmental ability of porcine oocytes following injection of round spermatid in the presence and absence of artificial activation. Electrical stimulation at 2 h before spermatid injection significantly increased the incidence of normal fertilization as compared to those following injection without stimulation or with stimulation immediately after injection. The incidences of two pronuclear formation and apposition were not different in oocytes between following intracytoplasmic spermatid and spermatid nucleus injection. Indirect immunocyto chemistry and laser scanning confocal microscopy study revealed that microtubuels were organized from the oocyte cortex following round spermatid injection, and this seemed to move both male and female pronuclei into the oocyte center. At 6 days following injection blastocoele formation was seen in the eggs following round spermatid (25%) and round spermatid nucleus injection (27%). However, none of oocytes developed to the blastocyst stage at 6 days following sham injection. The average cell numbers of blastocysts at 8 days following injection of spermatid and spermatid nucleus were 87 to 99. These results suggested that either round spermatid or it's nudeus can be used to produce viable embryos by injection into unfertilized oocytes in the pig.

  • PDF