• 제목/요약/키워드: laser stimulation

검색결과 97건 처리시간 0.029초

TENS와 He-Ne Laser를 이용한 외이자극이 지연성근육통에 미치는 영향 (Effects of TENS and He-Ne Laser at Auricular Point on Delayed Onset Muscle Soreness)

  • 박장성;김문수
    • 대한임상전기생리학회지
    • /
    • 제4권1호
    • /
    • pp.85-93
    • /
    • 2006
  • The purpose of this study was to determine the effect of transcutaneous electrical nerve stimulation(TENS) and He-Ne laser at auricular point on delayed onset muscle soreness(DOMS). Twenty healthy adult males and females performed eccentric exercise of the elbow flexor. DOMS was induced in a standardised fashion in the nondominant elbow flexor of all subject by repeated eccentric exercise. Subject were assigned randomly to one of trees groups. Group 1 received TENS to the appropriate auricular point for biceps pain, Group 2 received laser to the appropriate auricular point for wrist pain, Group 3 received no treatment and served as controls. After exercise, treatments were applied at 24 hours and at 48 hours and at 72 hours after. Group 1 showed stastically significant increase(p<0.05) in pain threshold after treatment whereas the Group 2 and 3 did not. Group 1 showed a significant increase in pain threshold than Group 2. These results suggest that TENS has the capability to higher pain threshold but laser does not.

  • PDF

Laser Speckle Contrast Imaging for Measuring Cerebral Blood Flow Changes Caused by Electrical Sensory Stimulation

  • Cho, Ahra;Yeon, Chanmi;Kim, Donghyeon;Chung, Euiheon
    • Journal of the Optical Society of Korea
    • /
    • 제20권1호
    • /
    • pp.88-93
    • /
    • 2016
  • Recently laser speckle contrast (LSC) imaging has become a widely used optical method for in vivo assessment of blood flow in the animal brain. LSC imaging is useful for monitoring brain hemodynamics with relatively high spatio-temporal resolution. A speckle contrast imaging system has been implemented with electrical sensory stimulation apparatus. LSC imaging is combined with optical intrinsic signal imaging in order to measure changes in cerebral blood flow as well as neural activity in response to electrical sensory stimulation applied to the hindlimb region of the mouse brain. We found that blood flow and oxygen consumption are correlated and both sides of hindlimb activation regions are symmetrically located. This apparatus could be used to monitor spatial or temporal responses of cerebral blood flow in animal disease models such as ischemic stroke or cortical spreading depression.

Human Spatial Cognition Using Visual and Auditory Stimulation

  • Yu, Mi;Piao, Yong-Jun;Kim, Yong-Yook;Kwon, Tae-Kyu;Hong, Chul-Un;Kim, Nam-Gyun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권2호
    • /
    • pp.41-45
    • /
    • 2006
  • This paper deals with human spatial cognition using visual and auditory stimulation. More specially, this investigation is to observe the relationship between the head and the eye motor system for the localization of visual target direction in space and to try to describe what is the role of right-side versus left-side pinna. In the experiment of visual stimulation, nineteen red LEDs (Luminescent Diodes, Brightness: $210\;cd/^2$) arrayed in the horizontal plane of the surrounding panel are used. Here the LEDs are located 10 degrees apart from each other. Physiological parameters such as EOG (Electro-Oculography), head movement, and their synergic control are measured by BIOPAC system and 3SPACE FASTRAK. In the experiment of auditory stimulation, one side of the pinna function was distorted intentionally by inserting a short tube in the ear canal. The localization error caused by right and left side pinna distortion was investigated as well. Since a laser pointer showed much less error (0.5%) in localizing target position than FASTRAK (30%) that has been generally used, a laser pointer was used for the pointing task. It was found that harmonic components were not essential for auditory target localization. However, non-harmonic nearby frequency components was found to be more important in localizing the target direction of sound. We have found that the right pinna carries out one of the most important functions in localizing target direction and pure tone with only one frequency component is confusing to be localized. It was also found that the latency time is shorter in self moved tracking (SMT) than eye alone tracking (EAT) and eye hand tracking (EHT). These results can be used in further study on the characterization of human spatial cognition.

635nm 레이저다이오드의 피부 결손 치유 효과 (Healing Effect of 635 nm Laser Diode in Skin Injury)

  • 천민우
    • 한국전기전자재료학회논문지
    • /
    • 제21권7호
    • /
    • pp.674-678
    • /
    • 2008
  • Low level laser therapy has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 635 nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. In this study, the designed device was used to find out how 635 nm laser diode affected the skin injury of SD-Rat(Sprague-Dawley Rat). We divided the participants into two groups; irradiation group which was irradiated 10 minutes a day for 9 consecutive days, and none irradiation group. The results showed that the study group had lower incidence of inflammation and faster recovery, compared with the control group.

다파장 레이저치료기의 개발 (Development of Multi-wavelength Laser Medical Therapy Apparatus)

  • 천민우;김성환;박용필;이호식;김태곤
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.736-741
    • /
    • 2007
  • Low level laser therapy has various therapy effects, This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm, 785nm and 850nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. In result, the $1{\sim}10\;Hz$ irradiation frequency could be controlled stably.

구강작열감 증후군 환자에서 Nd-YAG 레이저 조사에 대한 구강점막 부위의 통증 인지도와 점막세포 각화도와의 관계 (The Relationship between Pain Perception Scale and Keratinization Rate of Oral Mucosa to Nd-YAG Laser Stimulation in Burning Mouth Syndrome Patients)

  • 김지연;김병국;정성수
    • Journal of Oral Medicine and Pain
    • /
    • 제26권2호
    • /
    • pp.161-171
    • /
    • 2001
  • In order to determine how oral mucosal change relates to inducing factors of burning mouth syndrome, the difference in pain perception scale and keratinization rate between burning mouth syndrome patients and normal subjects were investigated. Twenty patients (13 female, 7 male, mean age: 59 years), presenting in the Department of Oral Medicine, Chonnam National University Hospital were participated in this study. All subjects had been complaining of constant oral burning pain for more than a year, none took any strong analgesics, and none had oral mucosal lesions. Twenty volunteers (11 females, 9 males, mean age: 25 years) were also participated in this study as a control group. The control subjects had never had any symptoms of oral burning pain. A thermal stimulation using a Nd-YAG laser and cytological smear were carried out to anterodorsal part of tongue, tip of tongue, the left buccal mucosa, the lower lip mucosa and the chief complaint site. Stimulation of the dorsum of left hand was also carried out to contrast the mucosal area of burning mouth syndrome subjects and the control subjects. The laser output power could be adjusted from 0.75W to 4W. The pain perception scale of the burning mouth syndrome subjects were lower than in control subjects in the chief complaint area, the anterodorsal part of tongue and the buccal mucosa(p<0.01). The keratinization rate of burning mouth syndrome subjects, however, was higher keratinization rate than in normal subjects in the same area and lower lip mucosa(p<0.001). From above results, the anterodorsal part of tongue is the most appropriate site to use diagnostic laser stimulation. The higher level of keratinization and the lower level of thermal pain perception of the burning mouth syndrome subjects are explained as a protective mechanism against xerostomia and burning sensations. The application of Nd-YAG laser stimuli and cytological smear to oral mucosal surface could therefore be usefully employed as appropriate and standardized diagnostic tools for chronic orofacial pain subjects.

  • PDF

혈류 개선용 레이저다이오드 치료기 개발 (Development of Laser Diode Medical Therapy Apparatus for Blood Stream Improvement)

  • 천민우;김성환;박용필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser therapy has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 7850m Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 785nm wavelength.

  • PDF

저출력 레이저 치료기의 광 출력 특성 (Characteristics of Optical Power of Low Level Laser Apparatus)

  • 천민우;김성환;박용필;유성미;박노봉;이희갑
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.496-496
    • /
    • 2007
  • Low level laser has various therapy effects. This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm Laser diode for blood stream improvement and was designed for a pulse width modulation type to increase stimulation effects. In result, we could get the light power of 660nm wavelength and the 1~10Hz irradiation frequency could be controlled stably.

  • PDF

Physiological and Psychological Effects of Vibroacoustic Stimulation to Scapular and Sacrum of Supine Position

  • Lim, Seung Yeop;Heo, Hyun;Kim, Sang Ho;Won, Byeong Hee
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.345-353
    • /
    • 2013
  • Objective: This research measured physiological and psychological effects of Vibroacoustic stimulation(VA) to scapular and sacrum of supine position on the mattress. Background: When vibroacoustic stimulation applies to human body, it has a positive influence on physiological and psychological effects by stimulating the organs, tissues and cells of whole body. Method: This experiment was conducted to 10 normal males in two conditions: no stimulation and vibroacoustic stimulation. No stimulation experiment was executed as a supine position for 30 minutes without any vibrational stimulus, while vibroacoustic stimulation was transmitted by the vibrational speaker, which uses 40Hz frequency. Subjects had a laser Doppler flowmeter probe in scapular, sacrum, and also had 8 channel electroencephalogram(EEG) measurement sensor in the scalp. Blood pressure and skin temperature were measured in two conditions with an underlying posture for 30 minutes. Additionally, blood flow rate and EEG were measured before and after for two minutes on two conditions. Results: According to the vibroacoustic stimulation, blood flow rate and skin temperature were increased, while blood pressure was decreased. When using vibroacoustic stimulation compared to no stimulation, blood flow rate went approximately two times higher, and skin temperature also higher 3~4 times. Furthermore, the relative alpha power of brain wave was significantly increased when we applied to vibroacoustic stimulation. Conclusion: This experiment tested the VAT embedded in mattress in two conditions. According to this experiment, VAT decreases blood pressure, improves not only a physiological effect on blood flow rate as well as skin temperature, but also psychological functions by increasing relative alpha power. Application: The results of the publishing trend analysis might help physiological and psychological effects of vibroacoustic stimulation.

저출력 레이저조사가 동통반응에 미치는 영향 (EFFECT OF LOW - POWER LASER IRRADIATION ON PAIN RESPONSE)

  • 김성교;윤수한;이종흔
    • Restorative Dentistry and Endodontics
    • /
    • 제16권2호
    • /
    • pp.85-98
    • /
    • 1991
  • The aim of this study was to investigate the effect of low - power laser used in the medical field for various purposes to suppress pain responses evoked by noxious electrical or mechanical stimuli. After both inferior alveolar nerves and the left anterior digastric muscle of cats under general anesthesia were exposed, a recording electrode for the jaw opening reflex was inserted into the anterior digastric muscle. The right inferior alveolar nerve was dissected under a surgical microscope until the response of the functional single nerve could be evoked by the electrical stimulation of the dental pulp or oral mucosa. The electrical stimulus was applied with a rectangular pulse of 10 ms duration for measuring the threshold intensity of a single nerve fiber in the inferior alveolar nerve which responds to stimulation of dental pulp and oral mucosa. Then a pulse of 1 ms duration was applied for determination of conduction velocity. A noxious mechanical stimulus to the oral mucosa was applied by clamping the receptive field with an arterial clamp. The Ga-As diodide laser(wave length, 904 nm ; frequency, 1,000 Hz) was irradiated to the prepared tooth cavity, inferior alveolar nerve and oral mucosa as a pulse wave of 2 mW for 6 minutes. This was followed by a continuous wave of 15 mW for 3 minutes. The action potential of the nerve and EMG of the digastric muscle evoked by the noxious electrical stimulus and nerve response to noxious mechanical stimulus were compared at intervals of before, immediately after, and at 5, 10, 20, 40, 60 minutes after laser irradiation. The results were as follows: The conduction velocity of the intrapulpal $A{\delta}$- nerve fiber recorded from the inferior alveolar nerve before irradiation had a mean value of $6.68{\pm}2.07m/sec$. The laser irradiation did not affect the conduction velocity of the AS - nerve fiber and did not change the threshold intensity or amplitude of the action potential either. The EMG of the digastric muscle evoked by noxious electrical stimulation to the tooth was not changed by the laser irradiation, whether in latency, threshold intensity or amplitude. The laser irradiated to the receptive field of the oral mucosa which was subjected to noxious stimuli did not affect the amplitude of the action potential or the frequency either.

  • PDF